首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   12篇
物理学   1篇
  2021年   1篇
  2015年   2篇
  2014年   1篇
  2013年   3篇
  2011年   3篇
  2009年   1篇
  2007年   2篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
A new circular dichroism sensor for detecting Ni2+ and Co2+ was proposed for the first time using chiral chelating quantum dots. The detection principle was based on changing of circular dichroism signals of the chiral quantum dots when forming a chiral complex with Ni2+ or Co2+. l-Cysteine capped cadmium sulfide quantum dots (l-Cyst-CdS QDs) were proposed as a chiral probe. The CD spectrum of l-Cyst-CdS QDs was significantly changed in the presence of Ni2+ and Co2+. On the other hand, other studied cations did not alter the original CD spectrum. Moreover, when increasing the concentration of Ni2+ or Co2+, the intensity of the CD spectrum linearly increased as a function of concentration and could be useful for the quantitative analysis. The proposed CD sensor showed linear working concentration ranges of 10–60 μM and 4–80 μM with low detection limits of 7.33 μМ and 1.13 μM for the detection of Ni2+ and Co2+, respectively. Parameters possibly affected the detection sensitivity such as solution pH and incubation time were studied and optimized. The proposed sensor was applied to detect Ni2+ and Co2+ in real water samples, and the results agreed well with the analysis using the standard ICP-OES.  相似文献   
2.
A new chemical sensor based on the measuring of circular dichroism signal (CD) was fabricated from cysteamine capped cadmium sulfide quantum dots (Cys-CdS QDs). The chiral-thiol molecules, d-penicillamine (DPA) and l-penicillamine (LPA), were used to evaluate potentials of this sensor. Basically, DPA and LPA provide very low CD signals. However, the CD signals of DPA and LPA can be enhanced in the presence of Cys-CdS QDs. The CD spectra of DPA and LPA exhibited a mirror image profile. Parameters affecting the determination of DPA and LPA were thoroughly investigated in details. Under the optimized condition, the CD signals of DPA and LPA displayed a linear relationship with the concentrations of both enantiomers, ranging from 1 to 35 μM. Detection limits of this sensor were 0.49 and 0.74 μM for DPA and LPA, respectively. To demonstrate a potential application of this sensor, the proposed sensor was used to determine DPA and LPA in real urine samples. It was confirmed that the proposed detection technique was reliable and could be utilized in a broad range of applications.  相似文献   
3.
A simple and automated method involving in-capillary derivatization and in-capillary preconcentration was developed for the simultaneous determination of metal ions by capillary zone electrophoresis. Fe(II), Zn(II), Cu(II) and Cd(II) were derivatized using 1,10-phenanthroline as the derivatizing agent. The in-capillary derivatization and in-capillary preconcentration via large volume injection were performed sequentially as follows: 60 mmol L?1 1,10-phenanthroline was first hydrodynamically injected (0.2 psi) for 2 s; metal ions were introduced by hydrodynamic injection (0.5 psi) for 60 s; 0.2 mol L?1 acetate pH 5.5 containing 20 % methanol was used as the running buffer. Four metal ions can be determined within 8 min using 16 kV. The resulting preconcentration factors were in the range 12–21. Good linearity was obtained for concentrations of 0.1–8.0 mg L?1 (r 2 > 0.990). The mean recoveries of the metal ions evaluated by fortification of wine samples were in the range 90–102 %. The limits of detection ranged from 0.05 to 0.2 mg L?1. The proposed method can be applied for directly determining metal ions in wine samples.  相似文献   
4.
Industrially, after the removal of oil from perilla seeds (PS) by screw-type compression, the large quantities of residual perilla seed meal (PSM) becomes non-valuable waste. Therefore, to increase the health value and price of PS and PSM, we focused on the biological effects of perilla seed oil (PSO) and rosmarinic acid-rich fraction (RA-RF) extracted from PSM for their role in preventing oxidative stress and inflammation caused by TNF-α exposure in an A549 lung adenocarcinoma culture model. The A549 cells were pretreated with PSO or RA-RF and followed by TNF-α treatment. We found that PSO and RA-RF were not toxic to TNF-α-induced A549 cells. Both extracts significantly decreased the generation of reactive oxygen species (ROS) in this cell line. The mRNA expression levels of IL-1β, IL-6, IL-8, TNF-α, and COX-2 were significantly decreased by the treatment of PSO and RA-RF. The Western blot indicated that the expression of MnSOD, FOXO1, and NF-κB and phosphorylation of JNK were also significantly diminished by PSO and RA-RF treatment. The results demonstrated that PSO and RA-RF act as antioxidants to scavenge TNF-α induced ROS levels, resulting in decreased the expression of MnSOD, FOXO1, NF-κB and JNK signaling pathway in a human lung cell culture exposed to TNF-α.  相似文献   
5.
New fluoroionophores 4 and 5 derived from calix[4]arene triester monoacid chloride with 2-amino-4-(1,3-benzothiazol-2-yl)phenol and 4-aminoquinaldine, respectively, have been synthesized. A preliminary test showed that the fluorescence intensity of 5 was very low, so only 4 was subjected to cation recognition investigation. In methanol, the fluorescence intensity of 4 was quenched by Na+. The fluorescence intensity decreased linearly with increasing Na+ concentration with a stability constant of log K = 2.91 ± 0.08. No significant response was observed for other alkali metal ions under the same experimental conditions.  相似文献   
6.
Mixed cationic and anionic surfactants were adsorbed on cadmium sulfide quantum dots (CdS QDs) capped with mercaptoacetic acid. The CdS QDs can be extracted into acetonitrile with 98 % efficiency in a single step. Phase separation only occurs at a molar ratio of 1:1.5 between cationic and anionic surfactants. The surfactant-adsorbed QDs in acetonitrile solution display stronger and more stable photoluminescence than in water solution. The method was applied for determination of silver(I) ion based on its luminescence enhancement of the QDs. Under the optimum conditions, the relative fluorescence intensity is linearly proportional to the concentration of silver(I) ion in the range between 50 pmol L?1and 4 μmol L?1, with a 20 pmol L?1 detection limit. The relative standard deviation was 1.93 % for 9 replicate measurements of a 0.2 μmol L?1 solution of Ag(I).
Figure
?  相似文献   
7.
Lipophilic H+-selective fluorophores such as Nile Blue derivatives are widely used in ISE-based pH sensors and bulk optodes, and are commonly dissolved in a plasticized matrix such as PVC. Unfortunately, leaching of the active sensing ingredients and plasticizer from the matrix dictates the lifetime of the sensors and hampers their applications in vivo, especially with miniaturized particle based sensors. We find that classical copolymerization of Nile Blue derivatives containing an acrylic side group gives rise to multiple reaction products with different spectral and H+-binding properties, making this approach unsuitable for the development of reliable sensor materials. This limitation was overcome by grafting Nile Blue to a self-plasticized poly(n-butyl acrylate) matrix via an urea or amide linkage between the Nile Blue base structure and the polymer. Optode leaching experiments into methanol confirmed the successful covalent attachment of the two chromoionophores to the polymer matrix. Both polymerized Nile Blue derivatives have satisfactory pH response and appropriate optical properties that are suitable for use in ion-selective electrodes and optodes. Plasticizer-free Na+-selective microsphere sensors using the polymerized chromoionophores were fabricated under mild conditions with an in-house sonic microparticle generator for the measurement of sodium activities at physiological pH. The measuring range for sodium was found as 10−1-10−4 M and 1-10−3 M, for Nile Blue derivatives linked via urea and amide functionalities, respectively, at physiological pH. The observed ion-exchange constants of the plasticizer-free microsphere were log Kexch = −5.6 and log Kexch = −6.5 for the same two systems, respectively. Compared with earlier Na+-selective bulk optodes, the fabricated optical sensing microbeads reported here have agreeable selectivity patterns, reasonably fast response times, and more appropriate measuring ranges for determination of Na+ activity at physiological pH in undiluted blood samples.  相似文献   
8.
Unmodified cysteamine capped nanocrystalline cadmium sulfide quantum dots (Cys-CdS QDs) were demonstrated as a selective turn-on fluorescence sensor for sensing adenosine-5′-triphosphate (ATP) in aqueous solution for the first time. The fluorescence intensity of the Cys-CdS QDs was significantly enhanced in the presence of ATP. In addition, the fluorescence intensity of the Cys-CdS QDs increased when increasing ATP concentrations. On the other hand, other phosphate metabolites and other tested common anions did not significantly alter the fluorescence intensity of the Cys-CdS QDs. In addition, this sensor showed excellent discrimination of pyrophosphate (PPi) from ATP detection. The proposed sensor could efficiently be used for ATP sensing at very low concentration with LOD of 17 μM with the linear working concentration range of 20–80 μM. The feasibility of the proposed sensor for determining ATP in urine samples was also studied, and satisfactory results were obtained.  相似文献   
9.
Luminescent CdS quantum dots capped with thioglycolic acid (CdS-TGA QDs) were demonstrated to serve as a fluorescence probe for a model organic radical, 2,2-diphenyl-1-picrylhydrazyl radical (DPPH), employing the quenching of the CdS-TGA QDs emission signal by the radical. Under the optimum conditions, the quenching efficiency of DPPH on CdS-TGA QDs was proportional to the concentration of DPPH, following Stern-Volmer relationship. Different types of surfactants (cationic, anionic and neutral surfactants) were introduced to CdS-TGA QDs in order to increase the detection sensitivity. The fluorescence intensity of CdS-TGA QDs was greatly enhanced by cationic and neutral surfactants. Moreover, the quenching efficiency of DPPH on the QDs in the presence of micelles was remarkably ca. 13 times higher than that in the system without micelles. Effects of pH and concentration of surfactants on the fluorescence quenching of CdS-TGA QDs were investigated. Electron spin resonance (ESR) spectroscopy was also used to monitor the DPPH radical species in CdS-TGA QDs mixtures with and without micelles. Fluorescence quenching mechanisms of CdS-TGA QDs by DPPH in the presence and in the absence of CTAB were proposed.  相似文献   
10.
Fabrication of PVC membrane electrodes incorporating selective neutral carriers for Cd(2+) was reported. The ionophores were designed to have different topologies, donor atoms and lipophilicity by attaching tripodal amine (TPA) units to the lipophilic anthracene (ionophore I) and p-tert-butylcalix[4]arene (ionophores II, III and IV). The synthesized ionophores were incorporated to the plasticized PVC membranes to prepare Cd(II) ion selective electrodes (ISEs). The membrane electrodes were optimized by changing types and amounts of ionic sites and plasticizers. The selectivity of the membranes fabricated from the synthesized ionophores was evaluated, the relationship between structures of ionophores and membrane characteristics were explored. The ionophore IV which composed of two opposites TPA units on the calix[4]arene compartment showed the best selectivity toward Cd(2+). The best membrane electrode was fabricated from ionophore IV (10.2 mmol kg(-1)) with KTpClPB (50.1 mol% related to the ionophore) as an ion exchanger incorporated in the DOS plasticized PVC membrane (1:2; PVC:DOS). The Cd-ISE fabricated from ionophore IV exhibited good properties with a Nernstian response of 29.4±0.6 mV decade(-1) of activity for Cd(2+) ions and a working concentration range of 1.6×10(-6)-1.0×10(-2)M. The sensor has a fast response time of 10s and can be used for at least 1 week without any divergence in potential. The electrode can be used in the pH range of 6.0-9.0. The proposed electrodes using ionophores III and IV were employed as a probe for determining Cd(2+) from the oxidation of CdS QDs solution and the real treatment waste water sample with excellent results.  相似文献   
1 [2] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号