排序方式: 共有10条查询结果,搜索用时 190 毫秒
1
1.
2.
The x-ray diffraction intensities of Bragg reflections have been measured at room temperature for thulium selenide, samarium sulphide, samarium selenide and samarium telluride. On the basis of a common amplitude approximation, the Debye-Waller factor, the mean amplitude of vibration and the Debye temperature have been evaluated. The values of the Debye temperatures and mean amplitudes of vibration are 176±16°K, 0·185 ± 0·017 Å (TmSe), 155 ± 7°K, 0·244 ± 0·012 Å (SmS), 153 ± 14°K, 0·221 ± 0·020 Å (SmSe) and 151 ± 20°K, 0·204 ± 0·027 Å (SmTe). 相似文献
3.
4.
Wang SJ Wu ST Gokemeijer J Fura A Krishna M Morin P Chen G Price K Wang-Iverson D Olah T Weiner R Tymiak A Jemal M 《Analytical and bioanalytical chemistry》2012,402(3):1229-1239
High-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA) methods were developed for the quantification of a PEGylated scaffold protein drug in monkey plasma samples. The LC-MS/MS method was based on the extraction of the therapeutic protein with a water-miscible organic solvent and the subsequent trypsin digestion of the extract followed by the detection of a surrogate peptide. The assay was linear over a range of 10-3,000 ng/mL. The ELISA method utilized a therapeutic target-binding format in which the recombinant target antigen was used to capture the drug in the sample, followed by detection with an anti-PEG monoclonal antibody. The assay range was 30-2,000 ng/mL. A correlation study between the two methods was performed by measuring the drug concentrations in plasma samples from a single-dose pharmacokinetic (PK) study in cynomolgus monkeys following a 5-mg/kg subcutaneous administration (n = 4). In the early time points of the PK profile, the drug concentrations obtained by the LC-MS/MS method agreed very well with those obtained by the ELISA method. However, at later time points, the drug concentrations measured by the LC-MS/MS method were consistently higher than those measured by the ELISA method. The PK parameters calculated based on the concentration data showed that the two methods gave equivalent peak exposure (C(max)) at 24-48 h. However, the LC-MS/MS results exhibited about 1.53-fold higher total exposure (AUC(tot)) than the ELISA results. The discrepancy between the LC-MS/MS and ELISA results was investigated by conducting immunogenicity testing, anti-drug antibody (ADA) epitope mapping, and Western blot analysis of the drug concentrations coupled with Protein G separation. The results demonstrated the presence of ADA specific to the engineered antigen-binding region of the scaffold protein drug that interfered with the ability of the drug to bind to the target antigen used in the ELISA method. In the presence of the ADAs, the ELISA method measured only the active circulating drug (target-binding), while the LC-MS/MS method measured the total circulating drug. The work presented here indicates that the bioanalysis of protein drugs may be complicated owing to the presence of drug-binding endogenous components or ADAs in the post-dose (incurred) samples. The clear understanding of the behavior of different bioanalytical techniques vis-à-vis the potentially interfering components found in incurred samples is critical in selecting bioanalytical strategies for measuring protein drugs. 相似文献
5.
A rigorous investigation of the identification of a heterogeneousflexural rigidity coefficient in the Euler-Bernoulli steady-statebeam theory in the presence of a prescribed load is presented.Mathematically, this study is an extension to higher-order differentialequations of the coefficient identification problem analysedby Marcellini (1982) for the one-dimensional Poisson equation.In addition, various types of boundary conditions are discussed.Conditions for the well-posedness of these inverse problemsare established and, furthermore, numerical results obtainedusing a regularization algorithm are presented. 相似文献
6.
The sensitivity of all ion trap mass spectrometry (ITMS) methods is dependent on the trapping efficiency of the instrument. For ITMS instruments utilizing external ion sources, such as laser desorption, trapping efficiency is known to depend on the phase and amplitude of the radio frequency (RF) potential applied to the ring electrode at the time of ion introduction. It is remarkable that, in a considerable body of literature, no consensus exists regarding the effects of these parameters on the efficacy of trapping externally generated ions. In this paper, a summary of the literature is presented in order to highlight significant discrepancies. New laser desorption ion trap mass spectrometry (LD-ITMS) data are also presented, from which conclusions are drawn in our effort to clarify some of the confusion. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
7.
8.
D Wang-Iverson E Ivashkiv M Jemal A I Cohen 《Rapid communications in mass spectrometry : RCM》1989,3(5):132-134
The acid form of lovastatin, an HMG-CoA reductase inhibitor, was analyzed by gas chromatography/negative-ion chemical ionization mass spectrometry after derivatization with pentafluorobenzyl bromide and bis-(trimethylsilyl)trifluoroacetamide (BSTFA). Mass spectrometry of this derivative produced a dominant [M-181]- ion under chemical ionization conditions using ammonia as the reagent gas. The limit of detection was approximately 2 pg injected on column. 相似文献
9.
Wu ST Xing J Apedo A Wang-Iverson DB Olah TV Tymiak AA Zhao N 《Rapid communications in mass spectrometry : RCM》2004,18(21):2531-2536
An automated chiral chromatography/tandem mass spectrometry bioanalytical method for the determination of albuterol in dog plasma was developed. The method employed on-line sample extraction using turbulent flow chromatography coupled to a Chirobiotic T column for chiral separation using a polar organic mobile phase consisting of methanol, 0.02% formic acid, and 0.1% ammonium formate. The analytes were detected by a tandem mass spectrometer operated in positive ion mode. The (S)- and (R)-isomers were resolved chromatographically with retention times of 5.1 and 5.6 min, respectively. The analytical run time was 8 min. The enantiomers did not interconvert either in mobile phase or in dog plasma at room temperature over the course of at least 2 h. The assay has a linear dynamic range from 2.5-2500 nM for both enantiomers. The lower limit of quantitation (LLOQ) was 2.5 nM for both enantiomers using 50 microL of plasma. The accuracy and precision of intraday validation were determined at five concentration levels of six replicates. The accuracy of the method for the (R)-isomer ranged from 94-103% of nominal concentrations, and the precision (%CV) ranged from 3.6-12%. The accuracy of the method for the (S)-isomer ranged from 94.5-108% of nominal concentrations, and the precision ranged from 3.2-9.3%. Interday accuracy and precision were evaluated for three days at five concentrations for one replicate. The accuracy of the method for the (R)-isomer ranged from 98-110% of nominal concentrations, and the precision ranged from 1.5-10.6%. The accuracy of the method for the (S)-isomer ranged from 96-104% of nominal concentrations, and the precision ranged from 1.5-8.7%. The combination of turbulent flow on-line sample extraction with polar organic mode chiral chromatography provided a specific, rugged, and high-throughput method for the chiral analysis of albuterol in biological fluids. 相似文献
10.
Peiran Liu Brian W. O’Mara Bethanne M. Warrack Wei Wu Yunping Huang Yihong Zhang Rulin Zhao Mei Lin Michael S. Ackerman Peter K. Hocknell Guodong Chen Li Tao Siegfried Rieble Jack Wang David B. Wang-Iverson Adrienne A. Tymiak Michael J. Grace Reb J. Russell 《Journal of the American Society for Mass Spectrometry》2010,21(5):837-844
Introduced in the late 1980s as a reducing reagent, Tris (2-carboxyethyl) phosphine (TCEP) has now become one of the most widely used protein reductants. To date, only a few studies on its side reactions have been published. We report the observation of a side reaction that cleaves protein backbones under mild conditions by fracturing the cysteine residues, thus generating heterogeneous peptides containing different moieties from the fractured cysteine. The peptide products were analyzed by high performance liquid chromatography and tandem mass spectrometry (LC/MS/MS). Peptides with a primary amine and a carboxylic acid as termini were observed, and others were found to contain amidated or formamidated carboxy termini, or formylated or glyoxylic amino termini. Formamidation of the carboxy terminus and the formation of glyoxylic amino terminus were unexpected reactions since both involve breaking of carbon—carbon bonds in cysteine. 相似文献
1