Vigliano  Marco  Bianchera  Annalisa  Bettini  Ruggero  Elviri  Lisa 《Chromatographia》2013,76(23):1761-1766

Two simple and fast C18 and HILIC liquid chromatography–electrospray mass spectrometry methods for the determination of hyaluronic acid (HA) in a mucoadhesive chitosan-based formulation were developed and validated. The performances of both methods were compared in terms of validation parameters and matrix effect. A simple sample preparation method based on sulphuric acid-based degradation was optimized for the detection of HA fragments (i.e. m/z 380 2-mer, m/z 759 4-mer, m/z 1,138 8-mer and m/z 1,518 16-mer). By operating under selected ion-monitoring mode, excellent selectivity towards chitosan fragments was obtained. For validation, good linearity, detection limits (<4 μg mL−1) and precision (RSD % < 16 %) were generally obtained on matrix with both columns. However, HILIC column exhibited improved performances in terms of HA fragment separation and selectivity. By analyzing on the C18 column the chitosan-based formulation and sample extracts from pig mucosa treated with the formulation, matrix effects exhibited a dependence of signal suppression degree (ranging from 37 to 83 %) as a function of the HA fragment dimension. The HILIC column afforded instead a significantly reduced suppression degree (ranging from 1 to 16 %) and a better separation. These findings demonstrated the improved performances of the HILIC column with respect to conventional C18 mechanism for the analysis of HA fragments in complex matrices.

  相似文献   
2.
Two simple and fast C18 and HILIC liquid chromatography–electrospray mass spectrometry methods for the determination of hyaluronic acid (HA) in a mucoadhesive chitosan-based formulation were developed and validated. The performances of both methods were compared in terms of validation parameters and matrix effect. A simple sample preparation method based on sulphuric acid-based degradation was optimized for the detection of HA fragments (i.e. m/z 380 2-mer, m/z 759 4-mer, m/z 1,138 8-mer and m/z 1,518 16-mer). By operating under selected ion-monitoring mode, excellent selectivity towards chitosan fragments was obtained. For validation, good linearity, detection limits (<4 μg mL?1) and precision (RSD % < 16 %) were generally obtained on matrix with both columns. However, HILIC column exhibited improved performances in terms of HA fragment separation and selectivity. By analyzing on the C18 column the chitosan-based formulation and sample extracts from pig mucosa treated with the formulation, matrix effects exhibited a dependence of signal suppression degree (ranging from 37 to 83 %) as a function of the HA fragment dimension. The HILIC column afforded instead a significantly reduced suppression degree (ranging from 1 to 16 %) and a better separation. These findings demonstrated the improved performances of the HILIC column with respect to conventional C18 mechanism for the analysis of HA fragments in complex matrices.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号