首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   49篇
  免费   0篇
  国内免费   1篇
化学   31篇
晶体学   1篇
数学   9篇
物理学   9篇
  2021年   1篇
  2018年   1篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
  2007年   3篇
  2006年   1篇
  2003年   2篇
  2002年   5篇
  2001年   4篇
  2000年   2篇
  1999年   3篇
  1998年   6篇
  1997年   4篇
  1996年   5篇
  1994年   2篇
  1986年   2篇
  1984年   1篇
  1980年   1篇
  1972年   1篇
  1970年   1篇
排序方式: 共有50条查询结果,搜索用时 31 毫秒
1.
Journal of Thermal Analysis and Calorimetry - In recent decades, the growth of heat transfer using nanomaterials in the conventional base fluid has caught the attention of researchers...  相似文献   
2.
3.
In quasi-steady operation, convection currents in a Bridgmandevice, used for producing a semi-conductor crystal, createinhomogeneities that may make the crystal unusable. It has oftenbeen suggested that additional forces due to rotation or magnetismmight be efficacious in reducing the segregation of the elementsof the alloy. It has been found that, over a wide range of rotationrates, there is no improvement in performance due to rotationabout the vertical axis. However, numerical results that havebeen obtained previously (Lee & Pearlstein, J. Crys. Growth240, 2002) indicate that, when effects of centrifugal buoyancyare introduced, a substantial reduction in segregation is achieved.In the work reported here, by contrast, in which we extend previouslarge-Rayleigh-number asymptotic analysis to include centrifugalbuoyancy, we find no improvement in radial segregation, butrather increasing segregation with increasing rotation rate.  相似文献   
4.
In general, petrochemical products contain only a limited number of chemical classes of compounds (sample dimensionality). The enormous number of individual components within these classes, however, soon puts limitations upon a single chromatographic technique when it comes to adequate characterization of these products. Comprehensive two-dimensional gas chromatography (GC×GC) clearly opens the possibility of estimating the composition of hydrocarbon mixtures in a far more detailed fashion than hitherto possible. Although the emphasis of papers of GCxGC thus far almost exclusively applies to the unsurpassed peak-capacity, in the oil industry there is a need for characterization, rather than for analyzing all the individual compounds. In principle a GCxGC system can provide an almost perfect match between its intrinsic properties and the dimensionality of oil samples. To establish the applicability of GCxGC towards petrochemical analytical challenges, a commercially aavailable prototype instrument was subjected to an exhaustive characterization of a typical hydrocarbon precess stream and a fast characterization of a light gas oil. Although there are no fundamental limitations towards the quantitative aspects of a GCxGC system, this paper confines itself to qualitative results only. Quantitative aspects of GCxGC will be published in a forthcoming paper.  相似文献   
5.
Flat channel asymmetrical flow field-flow fractionation with multi-angle light scattering (MALS) detection was used to study the swelling behaviour of core-shell particles with either carboxylated or hydroxylated shells as a function of pH and ionic strength. The equilibration time of the most heavily carboxylated core-shells appeared to be of the order of several hours. At low ionic strength (5 mM), the carboxylated core-shells showed a definite swelling response to a change in pH in the range from 5 to 10, ranging from a hydrodynamic radius increase of 24 to 118%, depending on the degree of carboxylation. A much milder response was found for the change of the root mean square (r.m.s.) radius as measured with MALS, indicating that the scattering plane is moving inwards during the swelling process due to a decreasing density of the shell. The hydroxylated core-shells appeared to be inert to a change in pH. Also the response of two expanded (pH 10) carboxylated core-shells on increasing ionic strength was studied. Comparison of the results of these ionic strength experiments with theoretical predictions based on Donnan equilibrium led us to the conclusion that a significant amount of counter-ion condensation may take place in the shells.  相似文献   
6.
In the present work, a controlled growth of ZnO nanostructures by manipulating Zn metal ion concentration by the chelating action of ethylene diaminetetra acetic acid in hydrothermal method is studied. EDTA produces metal–chelate complex by the formation of bidentate ligand with Zn2+ in the solution and diminishes the reactivity of Zn metal cations. Concentration of EDTA in the mother solution was varied in different ranges like 3, 5 and 10 mM while retaining the zinc metal salt and the NaOH concentration the same. Three different morphologies of wurtzite structured ZnO nanostructures such as nanorods-bunch, separate/discrete uniformly sized hexagonal nanorods and tapered flower petals like shapes are achieved by 3, 5 and 10 mM strengths of EDTA, respectively. The medium concentration 5 mM of EDTA is found to have moderate control over producing ZnO nanostructures of uniform diameter and a high aspect (length to diameter) ratio. An array of vertically aligned free standing ZnO nanorods with uniform spacing is successfully achieved by the addition of 5 mM of EDTA in the mother solution and the same is studied for its fluorescence property at an excitation of 325 nm and it has exhibited a characteristic UV emission of ZnO around 383 nm.  相似文献   
7.
8.
A modified sulfur chemiluniinescence detector (SCO) has been interfaced to a HPLC-HRGC hyphenated system. This combination enables the full characterization and quantitation of the sulfur containing compounds in (heavy) middle distillate oil fractions (boiling range 150–450°C). The system is suited to identify and determine the various groups of orgaiio-sulfur structures such as: thiols + sulfides + thiophencs, benzothiophenes, dibenzothiophenes and benzo-naphthothiophenes. Within these groups a separation according to boiling point is accomplished. Therefore it allows the separation, identification and quantitation of a number of individual species, especially those which are refractory to hydrodesulfu-rization (HDS), such as 3-methyl-benzothiophene, 4-methyl-dibenzothiophene and -J,6-dimethyl-dibenzothiophene. The analysis of these groups and specific compounds is the key in understanding the kinetics of the chemistry involved in HDS. The complete instrumental set-up is fully automated by computer control. To suppress possible interferences and quenching of the sulfur response of the SCL from (large amounts of) hydrocarbons, it is aligned above the adapted flame ionization detector (FID) of the GC. This renders a sensitivity of the SCO for sulfur of 2 pg. s?1, which corresponds to a minimum detectable level for individual sulfur species in oil fractions for the complete system of 1 ppm (mg. kg?1) sulfur. Its linear dynamic range exceeds 105, which means that also untreated, high sulfur containing feedstocks can be analyzed directly. The selectivity of sulfur to carbon of the modified SCO exceeds 106. A number of HDS feedstocks and desulfurized products of different desulfurization levels have been analyzed with the system. From the analysis results the behavior of the refractory compounds in HDS can now be followed closely.  相似文献   
9.
This paper shows the relationship between degeneracy degrees and multiple solutions in linear programming (LP) models. The usual definition of degeneracy is restricted to vertices of a polyhedron. We introduce degeneracy for nonempty subsets of polyhedra and show that for LP-models for which the feasible region contains at least one vertex it holds that the dimension of the optimal face is equal to the degeneracy degree of the optimal face of the corresponding dual model. This result is obtained by means of the so-called Balinski—Tucker (B—T) Simplex Tableaus. Furthermore, we give a strong polynomial algorithm for constructing such a B—T Simplex Tableau when a solution in the relative interior of the optimal face is known. © 1998 The Mathematical Programming Society, Inc. Published by Elsevier Science B.V.  相似文献   
10.
Summary Electrically driven size exclusion chromatography (ED-SEC) of polystyrenes in packed capillaries using dimethylformamide as solvent is demonstrated. The efficiency and retention behaviour of polystyrenes under pressure and electro drive were investigated. Under pressure drive the plate height (H) increases steadily with increasing linear velocity (u) whereas under electro drive the H-u curves largely coincide and are very flat. At higher velocities the plate heights are about 50% smaller with electro drive than with pressure drive. Calculations show that with increasing ionic strength, the flow through the particles may increase causing a clear diminishing of the elution window.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号