首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   18篇
  免费   0篇
化学   18篇
  2022年   1篇
  2014年   1篇
  2010年   1篇
  2009年   6篇
  2008年   8篇
  2007年   1篇
排序方式: 共有18条查询结果,搜索用时 15 毫秒
1.
An isocratic reversed-phase liquid chromatographic method has been developed for quantitative determination of candesartan cilexetil, used to treat hypertension, in the bulk drug and in pharmaceutical dosage forms. The method is also applicable to analysis of related substances. Chromatographic separation was achieved on a 250 mm × 4.6 mm, 5 μm particle, CN column with a 50:50 (v/v) mixture of phosphate buffer, pH 3.0, and acetonitrile as mobile phase. The flow rate was 1.0 mL min−1 and the detection wavelength was 210 nm. Resolution of candesartan cilexetil and six potential impurities was greater than 2.0 for all pairs of compounds. The drug was subjected to hydrolytic, oxidative, photolytic, and thermal stress and substantial degradation occurred in alkaline and acidic media and under oxidative and hydrolytic stress conditions. The major product obtained as a result of basic hydrolysis was different from that produced by acid hydrolysis and aqueous hydrolysis. The stress samples were assayed against a reference standard and the mass balance was found to be close to 99.6%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   
2.

Esaxerenone is a new nonsteroidal mineralocorticoid receptor antagonist utilized to treat high blood pressure. Chemically, esaxerenone is a pyrrole derivative consisting of hindered rotation, which results in stereoisomers named atropisomers. Currently, no methods exist for the separation and quantification of these atropisomers. A new and accurate chiral liquid chromatographic technique was developed and validated to estimate the enantiomeric purity of esaxerenone. Polar organic chiral separation was carried out on an immobilized amylose-based chiral stationary phase (Chiralpak IG) with methanol:acetonitrile:diethylamine (9:1:0.1, v/v/v) mixture as a mobile phase. The total runtime was 15 min, and the resolution (Rs) between the atropisomers was more than 3.0. The detection and quantification thresholds for the R-atropisomer were found to be 0.03 and 0.1 µg mL?1, respectively, for a test concentration of esaxerenone (1000 µg mL?1). Over the range from the limit of quantification to 0.3 percent, the method's linearity for the R-atropisomer was excellent (R2?>?0.999). The R-atropisomer recovery varied from 95 to 102%, confirming the method’s good accuracy. For a 48-h research period, the chemical was shown to be stable.

  相似文献   
3.
A new and accurate chiral liquid chromatographic method has been developed for the separation and quantification of (S,R,S)-enantiomer (unwanted enantiomer) and (R,R,R)-isomer (key intermediate) of aprepitant in bulk drug and formulation samples of apprepitant. The elution time was approximately 20 min using an immobilized amylose-based chiral stationary phase (Chiralpak-IA). The mobile phase was n-hexane and ethanol (90:10, v/v) and was delivered at a flow rate of 1.0 mL min?1. Detection was carried out with a wavelength set to 220 nm. The resolution factor between enantiomers was found to be greater than five. Limit of detection for both (S,R,S) enantiomer and (R,R,R) isomer of aprepitant was 0.035 µg, and limit of quantification for both (S,R,S) enantiomer and (R,R,R) isomers of aprepitant was 0.1 µg, for a 10 µL injection. The developed method showed excellent linearity (r > 0.999) for both isomers. When the method was applied to bulk drug samples and in pharmaceutical formulations recoveries were obtained ranging from 97.2 to 103.1%. Aprepitant sample solutions were found to be stable when characterized over a period of 48 h.  相似文献   
4.
A novel, sensitive, stability-indicating gradient RP-LC method has been developed for quantitative analysis of balsalazide disodium and its related impurities both in the bulk drug and in pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with a simple mobile-phase gradient prepared from methanol and phosphate buffer (10 mm potassium dihydrogen orthophosphate monohydrate, adjusted to pH 2.5 by addition of orthophosphoric acid). The mobile-phase flow rate was 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 240 nm. Under these conditions resolution of balsalazide disodium from its three potential impurities was greater than 2.0. Regression analysis resulted in a correlation coefficient greater than 0.99 for balsalazide disodium and all three impurities. This method was capable of detecting the three impurities at 0.003% of the test concentration of 0.3 mg mL?1, using an injection volume of 10 μL. Inter-day and intra-day precision for all three impurities and for balsalazide disodium was within 2.0% RSD. Recovery of balsalazide disodium from the bulk drug (99.2–101.5%) and from pharmaceutical dosage forms (99.8–101.3%), and recovery of the three impurities (99.1–102.1%) was consistently good. The test solution was found to be stable in 70:30 (v/v) methanol–water for 48 h. When the drug was subjected to hydrolytic, oxidative, photolytic, and thermal stress, acidic and alkaline hydrolysis and oxidizing conditions led to substantial degradation. The RP-LC method was validated for linearity, accuracy, precision, and robustness.  相似文献   
5.
A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min?1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL?1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   
6.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2009,69(3-4):369-373

A new and accurate chiral liquid chromatographic method has been developed for the separation of palonosetron hydrochloride (PALO) and its (R,R)-enantiomer in bulk drug samples with an elution time of about 20 min. The chromatographic separation was carried out by normal phase chromatography using an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with a mobile phase composed of n-hexane:ethanol:1,4 dioxane:trifluoroacetic acid:diethylamine (65:30:5:0.3:0.3, v/v) pumped at a flow rate of 1.0 mL min−1. The resolution (R s ) between the enantiomers was found to be greater than 3.0 and interestingly the (R,R)-enantiomer was eluted prior to the (S,S)-enantiomer (PALO) in the developed method. Mobile phase additives, trifluoroacetic acid and diethylamine played a key role in achieving chromatographic resolution between the enantiomers and also in enhancing chromatographic efficiency. The limit of detection (LOD) and limit of quantification (LOQ) of the (R,R)-enantiomer were found to be 0.03 and 0.1 μg respectively for 10 μL injection volume. The developed method shows excellent linearity (r 2 > 0.999) over a range of LOQ to 0.3% for the (R,R)-enantiomer. The percentage recovery of the (R,R)-enantiomer in bulk drug samples ranged from 97.2 to 102.3 revealing good sensitivity of the developed method. Robustness studies were also carried out on the developed method.

  相似文献   
7.
A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of deferasirox, its related impurities in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at 245 nm. The mobile phase consisted of buffer, acetonitrile and methanol (50:45:5, v/v) delivered at a flow rate of 1.0 mL min?1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 3.0 by using orthophosphoric acid. In the developed LC method the resolution (R s ) between deferasirox and its four potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.999 for deferasirox and its four impurities. This method was capable to detect all four impurities of deferasirox at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all four impurities and for deferasirox was found to be within 2.0% RSD. The method showed good and consistent recoveries for deferasirox in bulk drugs (98.3–101.1%), pharmaceutical dosage forms (100.2–103.1%) and for its all the four impurities (99.7–102.1%). The test solution was found to be stable in methanol for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.95%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   
8.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2008,68(11):1059-1062

A new and accurate chiral liquid chromatographic method has been developed for the determination of enantiomeric purity of darifenacin [(S)-enantiomer] in bulk drugs and extended release tablets. Normal phase chromatographic separation was performed on an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with n-hexane:ethanol:diethylamine (50:50:0.3, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1. The elution time was ~15 min. The resolution (R s ) between the enantiomers was greater than four and interestingly the (R)-enantiomer was eluted prior to darifenacin in the developed method. The limit of detection (LOD) and limit of quantification (LOQ) for the (R)-enantiomer were 0.02 μg and 0.07 μg, respectively, for a 10 μL injection volume. The method was extensively validated in terms of linearity, precision and accuracy and satisfactory results were obtained. Robustness studies were also conducted. The sample solution stability of darifenacin was determined and the compound was found to be stable for a study period of 48 h.

  相似文献   
9.

A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of mitotane, its impurity in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved using a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at a wavelength of 230 nm. The mobile phase consisted of buffer and acetonitrile (25:75, v/v) delivered at a flow rate of 1.0 mL min−1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 2.5 by orthophosphoric acid. In the developed LC method the resolution (R s ) between mitotane and its impurity namely Imp-1 was found to be greater than 2.5. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for mitotane and its impurity. This method was capable to detect the impurity of mitotane at a level of 0.003% with respect to test a concentration of 0.2 mg mL−1 for a 10 μL injection volume. The inter- and intra-day precision values for mitotane and its impurity was found to be within 2.0% RSD. The method has shown good and consistent recoveries for mitotane in bulk drugs (99.2–101.5%), pharmaceutical dosage forms (98.2–103.1%) and for its impurity (99.7–102.1%). The test solution was found to be stable in diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in basic stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.97%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.

  相似文献   
10.
A stability-indicating HPLC assay method was developed for the quantitative determination of tadalafil in bulk samples and in pharmaceutical dosage forms in the presence of the degradation products. It involved a 250 mm × 4.6 mm, 5 μm C-18 column. The gradient LC method employs solution A and B as mobile phase. Solution A contains a mixture of buffer (phosphate buffer and tetra-n-butyl ammonium hydrogen sulfate) pH 2.5: acetonitrile (80:20, v/v) and solution B contains a mixture of water: acetonitrile (20:80, v/v). The flow rate was 1.0 mL min−1 and the detection wavelength was 220 nm. The retention time of tadalafil is about 17 min. Tadalafil was subjected to different ICH prescribed stress conditions. Degradation was found to occur in hydrolytic and to some extent in oxidative stress conditions, while the drug was stable to photolytic and thermal stress. The drug was particularly labile under alkaline hydrolytic conditions. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The assay of stress samples was calculated against a qualified reference standard and the mass balance was close to 99.5%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and ruggedness.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号