排序方式: 共有32条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
7.
8.
Higgins AM Sferrazza M Jones RA Jukes PC Sharp JS Dryden LE Webster J 《The European physical journal. E, Soft matter》2002,8(2):137-143
We investigate the dynamics of spinodal dewetting in liquid-liquid polymer systems. Dewetting of poly(methyl-methacrylate)
(PMMA) thin films on polystyrene (PS) “substrates” is followed in situ using neutron reflectivity. By following the development of roughness at the PS/PMMA interface and the PMMA surface we extract
characteristic growth times for the dewetting process. These characteristic growth times are measured as a function of the
molecular weight of the two polymers. By also carrying out experiments in the regime where the dynamics are independent of
the PS molecular weight, we are able to use dewetting to probe the scaling of the PMMA thin film viscosity with temperature
and molecular weight. We find that this scaling reflects bulk behaviour. However, absolute values are low compared to bulk
viscosities, which we suggest may be due in part to slippage at the polymer/polymer interface.
Received 25 June 2001 and Received in final form 5 December 2001 相似文献
9.
Tompkins EM Farmer PB Lamb JH Jukes R Dingley K Ubick E Turteltaub KW Martin EA Brown K 《Rapid communications in mass spectrometry : RCM》2006,20(5):883-891
Accelerator mass spectrometry (AMS) is currently one of the most sensitive methods available for the trace detection of DNA adducts and is particularly valuable for measuring adducts in humans or animal models. However, the standard approach requires administration of a radiolabeled compound. As an alternative, we have developed a preliminary 14C-postlabeling assay for detection of the highly mutagenic O6-methyldeoxyguanosine (O6-MedG), by AMS. Procedures were developed for derivatising O6-MedG using unlabeled acetic anhydride. Using conventional liquid chromatography/mass spectrometry (LC/MS) analysis, the limit of detection (LOD) for the major product, triacetylated O6-MedG, was 10 fmol. On reaction of O6-MedG with 14C-acetic anhydride, using a specially designed enclosed system, the predominant product was 14C-di-acetyl O6-MedG. This change in reaction profile was due to a modification of the reaction procedure, introduced as a necessary safety precaution. The LOD for 14C-di-acetyl O6-MedG by AMS was determined as 79 amol, approximately 18,000-fold lower than that achievable by liquid scintillation counting (LSC). Although the assay has so far only been carried out with labeled standards, the degree of sensitivity obtained illustrates the potential of this assay for measuring O6-MedG levels in humans. 相似文献