首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   60篇
  免费   4篇
化学   47篇
数学   1篇
物理学   16篇
  2020年   2篇
  2019年   2篇
  2016年   1篇
  2015年   5篇
  2014年   2篇
  2013年   5篇
  2012年   5篇
  2011年   5篇
  2010年   2篇
  2009年   6篇
  2008年   6篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2004年   2篇
  2003年   1篇
  2002年   4篇
  2001年   2篇
  2000年   1篇
  1999年   5篇
  1993年   1篇
  1992年   1篇
  1991年   1篇
  1982年   1篇
排序方式: 共有64条查询结果,搜索用时 250 毫秒
1.
2.
Osmoregulants are the substances that help plants to tolerate environmental extremes such as salinity and drought. Proline and betaine are two of the most commonly studied osmoregulants. An indirect UV CE method has been developed for simultaneous determination of these osmoregulants. A variety of reported probes and compounds were examined as potential probes for the indirect detection of proline and betaine. Mobility and UV‐absorption properties highlighted sulfanilamide as a potential probe for indirect analysis of proline and betaine. Using 5 mM sulfanilamide at pH 2.2 with UV detection at 254 nm, proline and betaine were separated in less than 15 min. The LODs for proline and betaine were 11.6 and 28.3 μM, respectively. The developed method was successfully applied to quantification of these two osmoregulants in spinach and beetroot samples.  相似文献   
3.
Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre‐ or postcolumn oxidation for fluorescence detection (HPLC‐FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on‐site monitoring. In this study, CE methods were developed for C4D, FLD, UV absorption detection, and MS—making this first report of C4D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE‐UV and CZE‐C4D methods provide better resolution, selectivity, and separation efficiency compared to CZE‐MS and MEKC‐FLD. The sensitivity of the CZE‐C4D and MEKC‐FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE‐C4D and 60.9 to 104 ng/mL for MEKC‐FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE‐C4D and MEKC‐FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE‐C4D method suffered from significant interferences from the shellfish matrix, MEKC‐FLD was successfully used for PST screening of a periodate‐oxidized mussel sample, with results confirmed by HPLC‐FLD. This confirms the potential of MEKC‐FLD for screening of PSTs in shellfish samples.  相似文献   
4.
Catalytic activity of Os(VIII) in the oxidation of some twenty organic sulfides with sodium salt of N-chlorobenzenesulfonamide (CAB) has been investigated in alkaline (pH8.7) t-butanol–water (1:1 v/v) medium. Significant retarding influence of [OH] on the reactivity is exhibited. The catalysed reaction is strongly accelerated in the presence of Hg(II). Imperfections are observed in the linear Hammett relationship in the case of –NO2 substituents.  相似文献   
5.
Three strategies were investigated for the simultaneous separation and on-line preconcentration of charged and neutral hypolipidaemic drugs in micellar electrokinetic chromatography (MEKC). A background electrolyte (BGE) consisting of 20 mM ammonium bicarbonate buffer (pH 8.50) and 50 mM sodium dodecyl sulfate (SDS) was used for the separation and on-line preconcentration of the drugs. The efficiencies of sweeping, analyte focusing by micelle collapse (AFMC), and simultaneous field-amplified sample stacking (FASS) and sweeping, were compared for the preconcentration of eight hypolipidaemic drugs in different conductivity sample matrices. When compared with a hydrodynamic injection (5 s at 50 mbar, 0.51% of capillary volume to detection window) of drug mixture prepared in the separation BGE, improvements of detection sensitivity of 60-, 83-, and 80-fold were obtained with sweeping, AFMC and simultaneous FASS and sweeping, respectively, giving limits of detection (LODs) of 50, 36, and 38 μg/L, respectively. The studied techniques showed suitability for focusing different types of analytes having different values of retention factor (k). This is the first report for the separation of different types of hypolipidaemic drugs by capillary electrophoresis (CE). The three methods were validated then applied for the analysis of target analytes in wastewater samples from Hobart city.  相似文献   
6.
7.
Nano titanium dioxide (nTiO2), generally considered to be toxicologically inert, is manufactured in large quantities and extensively applied in consumer products. The small size and large surface area endow them with an active group or intrinsic toxicity. Advances in instrumentation are making Raman spectroscopy the tool of choice for an increasing number of (bio) chemical applications. One of the great advantages of this technique is its ability to provide information on the concentration, structure and interaction of biochemical molecules in their microenvironments within intact cells and tissues, non-destructively. Zebrafish (Danio rerio), one of the most important vertebrate model organisms used in developmental biology, are increasingly used in biomedical research, particularly as a model of human disease. In the present work, an attempt is made to study the effect of titanium dioxide, both nano and bulk, on the microenvironment of the liver tissues of Zebrafish using FT-Raman spectroscopy. The results of the present study suggest that TiO2 exposure demonstrate a marked influence on the microenvironments of the liver tissues of Zebrafish. A shift to a higher wavenumber and an increase in the intensity of the band at ∼1087 cm−1 in the TiO2 exposed tissues suggest that some of the conformational changes resulting from the alkali recovery process takes place due to TiO2 exposure. The decreased intensity ratio (I3220/I3400) observed in the titanium-exposed tissues suggests a decreased water domain size, which could be interpreted in terms of weaker hydrogen-bonded molecular species of water in the TiO2 exposed tissues. The observed shift of COO bands to higher frequencies shows the disruption of salt bridges as a result of a change in the oppositely charged partners and due to the enhanced random coil conformation. The variation in the intensity ratio of the tyrosyl doublet (I858/I825) indicates variation in the hydrogen bonding of the phenolic hydroxyl group due to TiO2 exposure. The results further suggest that the microenvironments are greatly altered due to titanium nano exposure when compared to titanium bulk. In conclusion, the results indicate that FT-Raman spectroscopy might be a useful tool for rapid assessment of nano particle biological interactions.  相似文献   
8.
Guijt RM  Breadmore MC 《Lab on a chip》2008,8(8):1402-1404
A UV light emitting diode (LED) with a maximum output of 372 nm was collimated using a pinhole and a small plastic tube and focused using a microscope objective onto a substrate for direct lithographic patterning of the photoresist. Movement of the substrate with a motorised linear stage (syringe pump) allowed lines in SU-8 to be pattered with a width down to 35 microm at a linear velocity of 80 microm s(-1), while in the dry film resist Ordyl SY 330, features as narrow as 17 microm were made at a linear velocity of 245 microm s(-1). At this linear velocity, a 75 mm long feature could be patterned in 5 min. Functional microfluidic devices were made by casting PDMS on a master made by LED lithography. The results show that UV LEDs are a suitable light source for direct writing lithography, offering a budget friendly, and high resolution alternative for rapid prototyping of features smaller than 20 microm.  相似文献   
9.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   
10.
Ionic electrophoretic mobilities determined by means of CE experiments are sometimes different when compared to generally accepted values based on limiting ionic conductance measurements. While the effect of ionic strength on electrophoretic mobility has been long understood, the increase in the mobility that results from Joule heating (the resistive heating that occurs when a current passes through an electrolyte) has been largely overlooked. In this work, a simple method for obtaining reliable and reproducible values of electrophoretic mobility is described. The electrophoretic mobility is measured over a range of driving powers and the extrapolation to zero power dissipation is employed to eliminate the effect of Joule heating. These extrapolated values of electrophoretic mobility can then be used to calculate limiting ionic mobilities by making a correction for ionic strength; this somewhat complicated calculation is conveniently performed by using the freeware program PeakMaster 5. These straightforward procedures improve the agreement between experimentally determined and literature values of limiting ionic mobility by at least one order of magnitude. Using Tris-chromate BGE with a value of conductivity 0.34 S/m and ionic strength 59 mM at a modest dissipated power per unit length of 2.0 W/m, values of mobility for inorganic anions were increased by an average of 12.6% relative to their values free from the effects of Joule heating. These increases were accompanied by a reduction in mobilities due to the ionic strength effect, which was 11% for univalent and 28% for divalent inorganic ions compared to their limiting ionic mobilities. Additionally, it was possible to determine the limiting ionic mobility for a number of aromatic anions by using PeakMaster 5 to perform an ionic strength correction. A major significance of this work is in being able to use CE to obtain reliable and accurate values of electrophoretic mobilities with all its benefits, including understanding and interpretation of physicochemical phenomena and the ability to model and simulate such phenomena accurately.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号