首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
化学   5篇
数学   1篇
物理学   10篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2005年   1篇
  2002年   2篇
  2000年   1篇
  1999年   3篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1988年   1篇
  1987年   1篇
排序方式: 共有16条查询结果,搜索用时 15 毫秒
1.
2.
This review presents the recent advances in the achievement of organized proteo-lipidic nanostructures based on Langmuir-Blodgett technology and their potential applications in the nanobioscience area. By using the self-assembled properties of amphiphilic biomolecules at the air-water interface, the Langmuir-Blodgett (LB) technique offers the possibility to prepare ultrathin layers suitable for biomolecule immobilization at the molecular level. This review will provide a general overview of the enzyme association with preformed Langmuir-Blodgett films in connection with their potential applications in biosensing device developments, and then introduce the design of a new functionalised biomimetic nanostructure with oriented recognition site. The potential applications of such an organized proteo-lipidic nanostructure for biocatalysis investigations of an immobilised enzyme in a biomimetic situation and for the development of bioelectronic devices are finally discussed.  相似文献   
3.
We report the fabrication of a thin silicon membrane with an array of micrometer and submicrometer pores that acts as a scaffold for suspending a lipid bilayer. We successfully deposited a lipid bilayer by the Langmuir-Blodgett method on a synthetic silicon membrane bearing arrays of pores with sizes of 1000, 650, and 300 nm. Topographic images obtained by AFM showed a suspended lipid film spanning the pores, whatever the pore size. Higher stability of bilayers supported on smaller pores was shown by AFM characterization. These results represent an important first step to creating a biomimetic environment to study cell membrane dynamics and/or in developing a biosensor.  相似文献   
4.
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
5.
The photocatalytic properties of commercialized self-cleaning glasses have been evaluated by the degradation of stearic acid C17H35COOH (SA), selected as a model molecule representative of fatty dirt. The relative amount of SA has been determined by measuring the FTIR peak area in the range 2752 and 2992 cm−1 corresponding to the C–H stretching bands. In order to estimate the thickness of one layer, the deposit of SA has been performed using the Langmuir–Blodgett (LB) method, which allows obtaining organized monomolecular layers of amphiphilic organics on a substrate. The thickness of one SA layer, obtained by Langmuir–Blodgett deposition, has been correlated to the FTIR signal. The photocatalytic degradation of a SA layer of a controlled thickness was carried out in a double jacket Pyrex reactor equipped with a UV Philips HPK 125 lamp. The photocatalytic degradation rate of the SA layer with different thicknesses was determined. The SA degradation rate was investigated under UV-A and UV-B irradiations to determine the influence of the photon wavelength range on efficiency.  相似文献   
6.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
7.
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported.  相似文献   
8.
AP Balachandran 《Pramana》2002,59(2):359-368
We review certain emergent notions on the nature of space-time from noncommutative geometry and their radical implications. These ideas of space-time are suggested from developments in fuzzy physics, string theory, and deformation quantization. The review focuses on the ideas coming from fuzzy physics. We find models of quantum space-time like fuzzy S 4 on which states cannot be localized, but which fluctuate into other manifolds like CP3. New uncertainty principles concerning such lack of localizability on quantum space-times are formulated. Such investigations show the possibility of formulating and answering questions like the probability of finding a point of a quantum manifold in a state localized on another one. Additional striking possibilities indicated by these developments is the (generic) failure of CPT theorem and the conventional spin-statistics connection. They even suggest that Planck’s ‘constant’ may not be a constant, but an operator which does not commute with all observables. All these novel possibilities arise within the rules of conventional quantum physics, and with no serious input from gravity physics.  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号