首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   76篇
  免费   1篇
  国内免费   3篇
化学   76篇
数学   2篇
物理学   2篇
  2022年   3篇
  2019年   2篇
  2017年   1篇
  2015年   1篇
  2014年   1篇
  2013年   3篇
  2012年   3篇
  2011年   5篇
  2010年   4篇
  2009年   8篇
  2008年   7篇
  2007年   9篇
  2006年   7篇
  2005年   7篇
  2004年   7篇
  2003年   7篇
  2002年   3篇
  2001年   1篇
  1987年   1篇
排序方式: 共有80条查询结果,搜索用时 296 毫秒
1.
A single-polarization filter comprising a gold-coated photonic crystal fiber based on surface plasmon resonance is designed and investigated. The pattern matching and coupled polarization characteristics analyzed by the full-vector finite element method (FEM) and losses at 1,540 nm are achieved to 1,016.01739 dB/cm (x-pol core mode) and 33.81917 dB/cm (y-pol core mode). The crosstalk (CT) value of the 1,540 nm band is ?853.12653 dB for fiber length L=1,000μm and the bandwidth is 850 nm. The working wavelength of the filter ranges from 1,280 nm to 1,540 nm by varying the diameter of outer air holes (d1), the diameter of inner air holes (d4), the metal film thickness (t), as well as the liquid refractive index (n).  相似文献   
2.
The chiral separation of simendan enantiomers using capillary electrophoresis was studied with beta-cyclodextrin (beta-CD) as chiral selector. The influences of the concentration and pH of borate buffer solution, beta-CD concentration and methanol content in the background electrolyte were investigated. These factors were compared with those in an HPLC with beta-CD as chiral mobile phase additive (CMPA-HPLC). The quantification properties of the developed CE method were examined. A baseline separation of simendan enantiomers was achieved in the background electrolyte of 20 mmol/L borate buffer (pH 11.0) containing 12 mmol/L beta-CD-methanol (50:50 in volume ratio). The CE method is comparable with CMPA-HPLC in chiral resolution, although the optimal pH in CE (11.0) is much higher than that (6.0) in CMPA-HPLC. This chiral CE method is applicable to the quantitative ananlysis and enantiomeric excess value determination of L-simendan.  相似文献   
3.
高效液相色谱法测定大鼠血浆中的原儿茶酸   总被引:3,自引:0,他引:3  
《色谱》2007,25(2):207-210
建立了大鼠血浆中原儿茶酸含量测定的高效液相色谱方法。采用的色谱柱为DiamondsilTM C18 柱(150 mm×4.6 mm,5 μm);流动相为乙腈-水(体积比为9∶91,用H3PO4 调pH至2.5);流速1.2 mL/min;检测波长260 nm;内标为对羟基苯甲酸。原儿茶酸的线性范围为0.050~3.20 mg/L,线性相关系数为0.9978,最低定量限为0.050 mg/L,日内和日间测定的精密度(以相对标准偏差表示)均低于7.0%,准确度(以相对误差表示)为-1.4%~2.6%;在0.050,0.40,3.20 mg/L低、中、高3个添加浓度水平下,血浆样品的提取回收率分别为83.4%,87.3%,91.1%。该方法简便,灵敏,准确,适用于大鼠体内原儿茶酸的药物动力学研究。  相似文献   
4.
High-performance frontal analysis coupled with chemiluminescence detection (HPFA-CL) was developed for the determination of unbound oxacillin concentration in human serum albumin solution. The HPFA system consisted of an ISRP column and a mobile phase of 67 mM potassium phosphate buffer of pH 7.4 and ionic strength of 0.17. The luminol-H2O2-Co2+ system was used in the chemiluminescence detection. An enhancement of luminol chemiluminescence by oxacillin was investigated and employed for determining the concentration of oxacillin in the HPFA eluate. Sample solutions were directly injected onto the column; the drug was eluted as a zonal peak with a plateau region. The unbound drug concentrations were determined by using the height of the plateau. The results agreed with those obtained with conventional ultrafiltration-HPLC method. Good reproducibility was confirmed by the within run and between run RSD < or = 7.4%. HPFA-CL provided a selective method for determination of unbound drug concentration in protein binding equilibrium.  相似文献   
5.
A sensitive, rapid and selective ultra‐performance liquid chromatography–tandem mass spectrometric (UPLC‐MS/MS) method was developed for the determination and pharmacokinetic study of domperidone in human plasma. Diphenhydramine was used as the internal standard. Plasma sample pretreatment involved a one‐step liquid–liquid extraction with a mixture of diethyl ether–dichloromethane (3:2, v/v). The analysis was carried out on an Acquity UPLCTM BEH C18 column. The mobile phase consisted of methanol–water containing 10 mmol/L ammonium acetate and 0.5% (v/v) formic acid (60:40, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionizationsource with positive mode. Each plasma sample was chromatographed within 2.1 min. The standard curves for domperidone were linear (r2 ≥ 0.99) over the concentration range of 0.030–31.5 ng/mL with a lower limit of quantification of 0.030 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 13% and accuracy (relative error) was from ?7.6 to 1.2% at three quality control levels. The method herein described was superior to previous methods and was successfully applied to the pharmacokinetic study of domperidone in healthy Chinese volunteers after oral administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
6.
Guo X  Fukushima T  Li F  Imai K 《The Analyst》2002,127(4):480-484
A column-switching HPLC method employing both octadecylsilica (ODS) and chiral columns with fluorescence detection was developed for the determination of enantiomer of fluoxetine (FLX), an antidepressant drug, in rat plasma. Racemic FLX was derivatized with a fluorescent reagent, 4-(N-chloroformylmethyl-N-methyl)amino-7-nitro-2,1,3-benzoxadiazole (NBD-COCl) or 4-(N-chloroformylmethyl-N-methyl)amino-7-N,N-dimethylaminosulfonyl-2,1,3-benzoxadiazole (DBD-COCl) and the enantiomeric separation of the resultant derivatives was examined on an amylose-based chiral column (CHIRALPAK AD-RH) in the reversed-phase mode. The derivative with NBD-COCl (NBD-FLX) showed a sufficient separation factor (a) and resolution (Rs) compared with that with DBD-COCl. Thus, FLX was derivatized with NBD-COCl and the resultant NBD-FLX was first quantified on the ODS column and then introduced to the CHIRALPAK AD-RH column via a six-port switching valve to examine the enantiomeric ratio. The intra- and inter-day accuracy (97.6-112.7%) and precision (1.47-10.60%) were satisfactory in the range 10-1000 nM FLX and the limit of quantification was approximately 10 nM. The absolute recoveries of FLX with hexane from rat plasma were in the range 87.5-92.2% (n = 3). The method was applied to determine FLX enantiomers in the plasma of rats administered FLX orally, and it was shown that the R-isomer was eliminated faster than the S-isomer.  相似文献   
7.
An UPLC/MS/MS based metabonomic method was developed and applied to the elucidation of biomarker of metformin action. The plasma metabolite profiling in healthy volunteers before and after per os metformin was determined with UPLC/MS/MS and analyzed by using multivariate statistics. Significant difference in endogenous metabolite profiles was revealed before and after administration of metformin. Four biomarkers found were lysophosphatidylcholines (LPCs), and their structures were tentatively identified to be 16:0 LPC, 18:0 LPC, 18:1 LPC and 18:2 LPC according to the molecular ions information and corresponding fragments of product ion scan. Lysophosphatidylcholine in blood may be involved in metformin treatment. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
8.
Yang J  Guan J  Pan L  Jiang K  Cheng M  Li F 《Analytica chimica acta》2008,610(2):263-267
Simple and efficient analytical HPLC methods using Chiralpak AS-H as chiral stationary phase were developed for direct enantioseparation of 11 novel phenylethanolamine derivatives. The chromatographic experiments were performed in normal phase mode with n-hexane–ethanol–triethylamine (TEA) as mobile phase. Excellent baseline enantioseparation was obtained for most of compounds. The effects of the concentration of organic modifiers and column temperature were studied for the enantiomeric separation. The mechanism of chiral recognition was discussed based on the relationship between the thermodynamic parameters and structures of compounds. It was found that the enantioseparations were all enthalpy driven, and the tert-butyl groups of compounds had significant influence on the chiral recognition. Trantinterol enantiomers were resolved (Rs = 2.73) within 14 min using n-hexane–ethanol–TEA (98:2:0.1, v/v/v) as mobile phase with a flow rate of 0.8 mL min−1 at 30 °C. The optimized method was validated for linearity, precision, accuracy and stability in solution and proved to be robust. The limits of detection (LOD) and quantification (LOQ) for (+)-trantinterol were 0.15 and 0.46 μg mL−1. The method was applied for enantiomeric impurity determination of (−)-trantinterol bulk samples.  相似文献   
9.
中药色谱指纹图谱组分保留时间漂移的校准   总被引:23,自引:6,他引:17  
基于光谱相关色谱方法判断复杂中药色谱指纹图谱的组分相关性,实现同一中药样本在不同实验条件下所得的色谱指纹图谱的相同组分的色谱保留时间漂移的局部最小二乘校正,为合理评价指纹图谱的品质提供较为实用的工具。  相似文献   
10.
Li X  Xiong Z  Ying X  Cui L  Zhu W  Li F 《Analytica chimica acta》2006,580(2):170-180
A rapid ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometric (UPLC–ESI-MS/MS) method was developed for the qualitative and quantitative determination of the constituents of the flower of Trollius ledibouri Reichb. The analysis was performed on an AcQuity UPLC™ BEH C18 column using gradient elution with a mobile phase of 0.1% acetic acid and acetonitrile over 20 min. A tandem quadrupole spectrometer operating in either full scan mode or in MS/MS mode for multiple reaction monitoring (MRM) was used for the qualitative and quantitative analysis of the constituents, respectively. According to the mass spectrometric fragmentation mechanism and UPLC–ESI-MS/MS data, the chemical structures of 15 constituents of the flower of T. ledibouri Reichb. were identified on-line without time-consuming isolation and four of them, 2″-O-β-l-galactopyranosylorientin, 2″-O-β-arabinopyranosylorientin, orientin and vitexin, were quantified. The limits of quantification of these four flavonoids were 540, 321, 515 and 220 μg g−1 plant material, respectively. Four commercial samples from different sources were analyzed. The UPLC–ESI-MS/MS method for analyzing the constituents can be used to evaluate the quality of the flower of T. ledibouri Reichb.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号