首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   71篇
  免费   10篇
化学   59篇
力学   4篇
数学   16篇
物理学   2篇
  2021年   4篇
  2020年   2篇
  2019年   2篇
  2018年   2篇
  2017年   1篇
  2016年   6篇
  2015年   7篇
  2014年   6篇
  2013年   9篇
  2012年   8篇
  2011年   7篇
  2010年   5篇
  2009年   6篇
  2008年   2篇
  2007年   3篇
  2006年   2篇
  2005年   4篇
  2004年   1篇
  2002年   1篇
  1996年   1篇
  1995年   1篇
  1989年   1篇
排序方式: 共有81条查询结果,搜索用时 15 毫秒
1.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   
2.
An environmentally friendly copper‐based catalyst supported on 2‐Methoxy‐1‐phenylethanone functionalized MCM‐41 was prepared and characterized by FT‐IR, FE‐SEM, TEM, XRD, EDX, BET and ICP techniques. The catalyst was applied for the C?S cross‐coupling reaction of aryl halides with thiourea. Corresponding products were produced in good yields in aerobic conditions. The catalyst could be recovered and recycled for several times.  相似文献   
3.
In this work, electrophoresis was successfully used to separate three different polymer-coated magnetic iron oxide nanoparticles with similar sizes (nominally 50 nm) using high-pH borate buffer system. The coating polymers were dextran, polyethylene glycol, or carboxymethyl dextran. The results showed that the migration time of carboxymethyl dextran coated nanoparticles is the longest due to relatively more negative surface charges. Investigation of the effects of buffer concentration, pH, electric field strength and the capillary temperature, on electrophoretic properties of samples was also carried out. The results showed that pH, electric field strength and the capillary temperature had indirect relations with both of the migration time and the separation resolution of three different polymer-coated nanoparticles while the buffer concentration had a direct relation.  相似文献   
4.
In this paper, electromembrane extraction coupled with differential pulse voltammetry (DPV) on a reduced graphene oxide modified screen‐printed carbon electrode (RGO‐SPCE) for the determination of dextromethorphan (DXM) in urine and plasma has been described. DXM migrated from 4 mL of a donor phase across a thin layer of 2‐nitrophenyl octyl ether (NPOE) immobilized in the pores of a porous hollow fiber, into a 20 µL acceptor phase (HCl) present inside the lumen of the fiber. Then, 15 µL of a 0.1 M NaOH solution was added to the acceptor phase and the mixture was analyzed using DPV.  相似文献   
5.
Journal of Thermal Analysis and Calorimetry - Due to global concerns about the emissions, limited hydrocarbon fuel resources and high fuel prices, a lot of researches have been done to improve the...  相似文献   
6.
A simple, highly sensitive, accurate and selective method for the determination of trace amounts of Ni2+ ions in water samples is proposed. The method is based on the separation and preconcentration of Ni2+ on an octadecyl-bonded silica (ODBS) membrane disk modified by a recently synthesized Schiff’s base N,N′-bis (3-methylsalicylidene) ortho phenylene diamine (MSOPD) at pH 7. The synthesis of this extractant ligand is also described. The retained nickel on the membrane was eluted with 2×5 ml 0.5 M HNO3 and measured by flame atomic absorption spectrometry (FAAS) at 232.0 nm. The extraction efficiency and the influence of the type and least amount of eluent for the stripping of Ni2+ from the disks, pH, flow rates of sample solution and eluent, amount of MSOPD, effect of other ions, and breakthrough volume were evaluated. The maximum capacity of the membrane disks modified by 3 mg of MSOPD was found to be 146±4 μg Ni2+. The 3σ limit of detection of the method was 30 ng per 1000 ml and also an enrichment factor of 250 was obtained. The proposed method has been applied to the determination of nickel in several water samples with satisfactory results.  相似文献   
7.

In this study, an oxadiazole multi-wall carbon nanotube-modified glassy carbon electrode (OMWCNT−GCE) was used as a highly sensitive electrochemical sensor for hydrazine determination. The surface charge transfer rate constant, k s, and the charge transfer coefficient, α, for electron transfer between GCE and electrodeposited oxadiazole were calculated as 19.4 ± 0.5 s−1 and 0.51, respectively at pH = 7.0. The obtained results indicate that hydrazine peak potential at OMWCNT−GCE shifted for 14, 109, and 136 mV to negative values as compared with oxadiazole-modified GCE, MWCNT−GCE, and activated GCE surface, respectively. The electron transfer coefficient, α, and the heterogeneous rate constant, k′, for the oxidation of hydrazine at OMWCNT−GCE were also determined by cyclic voltammetry measurements. Two linear dynamic ranges of 0.6 to 10.0 μM and 10.0 to 400.0 μM and detection limit of 0.17 μM for hydrazine determination were evaluated using differential pulse voltammetry. In addition, OMWCNT−GCE was shown to be successfully applied to determine hydrazine in various water samples.

  相似文献   
8.
This study investigated the use of ultrasound‐assisted extraction to improve the extraction efficiency of morphine, codeine and thebaine from the papaver plants. Extraction conditions such as type of solvent, temperature, duration, frequency and power level of ultrasonic were optimized and the influences of different parameters on resolution of alkaloids in CE were studied. The optimized condition for CE separation includes a sodium phosphate buffer (100 mM, pH 3.0) containing 5 mM α‐CD. The optimized extraction conditions for ultrasound‐assisted extraction was an extraction time of 1 h, an ultrasonic frequency of 60 kHz with water–methanol (80:20) at 40°C as the extraction solvent. The LOD for alkaloids was found to be 0.1 μg/mL at a signal‐to‐noise ratio of 3:1. The RSDs for peak areas were in the range of 1.4–4.4%. The amounts of opium alkaloids (mg/100 g dried sample) in four Iranian papaver plants were found to be in the range of 7.8–8.7 (morphine), 5.5–9.5 (codeine) and 1.4–10.4 (thebaine). It should be emphasized that no cleanup of the filtered extract was required; hence, direct determination after extraction drastically simplifies the analytical process.  相似文献   
9.
Let be two monomial ideals of the polynomial ring . In this paper, we provide two lower bounds for the Stanley depth of . On the one hand, we introduce the notion of lcm number of , denoted by , and prove that the inequality holds. On the other hand, we show that , where denotes the order dimension of the lcm lattice of . We show that I and satisfy Stanley's conjecture, if either the lcm number of I or the order dimension of the lcm lattice of I is small enough. Among other results, we also prove that the Stanley–Reisner ideal of a vertex decomposable simplicial complex satisfies Stanley's conjecture.  相似文献   
10.
Let 𝕂 be a field, and let R = 𝕂[x 1,…, x n ] be the polynomial ring over 𝕂 in n indeterminates x 1,…, x n . Let G be a graph with vertex-set {x 1,…, x n }, and let J be the cover ideal of G in R. For a given positive integer k, we denote the kth symbolic power and the kth bracket power of J by J (k) and J [k], respectively. In this paper, we give necessary and sufficient conditions for R/J k , R/J (k), and R/J [k] to be Cohen–Macaulay. We also study the limit behavior of the depths of these rings.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号