全文获取类型
收费全文 | 67篇 |
免费 | 0篇 |
专业分类
化学 | 51篇 |
物理学 | 16篇 |
出版年
2012年 | 2篇 |
2011年 | 3篇 |
2010年 | 1篇 |
2009年 | 5篇 |
2008年 | 3篇 |
2007年 | 3篇 |
2006年 | 3篇 |
2005年 | 5篇 |
2004年 | 7篇 |
2003年 | 2篇 |
2002年 | 8篇 |
2001年 | 2篇 |
2000年 | 3篇 |
1998年 | 1篇 |
1997年 | 1篇 |
1995年 | 1篇 |
1993年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1988年 | 2篇 |
1987年 | 2篇 |
1986年 | 2篇 |
1984年 | 2篇 |
1983年 | 1篇 |
1981年 | 1篇 |
1975年 | 1篇 |
1968年 | 1篇 |
1928年 | 1篇 |
排序方式: 共有67条查询结果,搜索用时 15 毫秒
1.
A. I. Magunov A. Ya. Faenov I. Yu. Skobelev T. A. Pikuz E. Biémont P. Quinet F. Blasco C. Bonte F. Dorchies T. Caillaud F. Salin C. Stenz 《Journal of Experimental and Theoretical Physics》2002,95(6):998-1005
The satellite structure of 1s2p 1,3 P 1-1s 21 S 0 lines of the He-like argon ion in plasma produced by a 45-fs laser pulse in a gas-jet cluster target is measured with a high spectral resolution. Radiation transitions 2p → 1s from autoionizing states (AISs) are detected for ions ranging from Li-like to F-like. The spectrum observed is theoretically simulated with the use of the spectroscopic data for the AISs of multicharged ions obtained within the multiconfiguration relativistic Hartree-Fock method. Good agreement with experimental data is obtained when the main population channels of these states are taken into account for typical values of cluster-target plasma parameters. 相似文献
2.
Alexopoulos T Allen C Anderson EW Areti H Banerjee S Beery PD Biswas NN Bujak A Carmony DD Carter T Cole P Choi Y De Bonte RJ Erwin AR Findeisen C Goshaw AT Gutay LJ Hirsch AS Hojvat C Kenney VP Lindsey CS LoSecco JM McMahon T McManus AP Morgan N Nelson KS Oh SH Piekarz J Porile NT Reeves D Scharenberg RP Stampke SR Stringfellow BC Thompson MA Turkot F Walker WD Wang CH Wesson DK 《Physical review letters》1990,64(9):991-994
3.
Goossens JF Foulon C Villard AL Puy JY Lefebvre I Perigaud C Vaccher C Bonte JP 《Biomedical chromatography : BMC》2005,19(6):415-425
Analytical HPLC methods using derivatized cellulose and amylose chiral stationary phases used in normal and reversed-phase modes were developed for the diastereoisomeric separation of mononucleotide prodrugs (pronucleotides) of 3'-azido-2',3'-dideoxythymidine (AZT). The resolutions were performed with two silica-based celluloses using normal and reversed-phase methodologies: Tris-3,5-dimethylphenylcarbamate (Chiralcel OD-H and Chiracel OD-RH) and Tris-methylbenzoate (Chiralcel OJ and OJ-R). Two amyloses phases, Tris-3,5-dimethylphenylcarbamate (Chiralpak AD) and Tris-(S)-1-phenylethylcarbamate (Chiralpak AS), were used in normal-phase mode. Additionally, we developed separation using two stationary phases with immobilized cyclodextrins in reversed-phase and polar-organic modes. The mobile phase and the chiral stationary phase were varied to achieve the best resolution. Different types and concentration of aliphatic alcohols, acetonitrile or water in the mobile phase were also tested for the different separation modes. An optimal baseline separation (Rs > 1.5) was readily obtained with all silica-based celluloses and amyloses using a normal-phase methodology. The different columns gave complementary results in term of resolution. Limits of detection and quantification were 0.12-0.20 and 0.40-0.67 microm, respectively. This analytical method was applied in a preliminary study for the pronucleotide 2 quantification in cellular extract. 相似文献
4.
Baseline separation of ten new substituted [1-(imidazo-1-yl)-1-phenylmethyl)] benzothiazolinone and benzoxazolinone derivatives, with one chiral center, was achieved by CD-EKC using highly sulfated CDs (alpha, beta, gamma highly S-CDs) as chiral selectors. The influence of the type and concentration of the chiral selectors on the enantioseparations was investigated. The highly S-CDs exhibit a very high enantioselectivity power since they allow excellent enantiomeric resolutions compared to those obtained with the neutral CDs. The enantiomers were resolved with analysis times inferior to 2.5 min and resolution factors R(s) of 3.73, 3.90, 1.40, and 4.35 for compounds 1, 2, 3, and 5, respectively, using 25 mM phosphate buffer at pH 2.5 containing either highly S-alpha-CD, highly S-beta-CD, and highly S-gamma-CD (3 or 4% w/v) at 298 K, with an applied field of 0.30 kV/cm. The determination of the enantiomer migration order for the various analytes and the study of the analyte structure-enantioseparation relationships display the high contribution of the interactions between the analytes phenyl ring and the CDs to the enantiorecognition process. The thermodynamic study of the analyte-CD affinities permits us to improve our knowledge about the enantioseparation mechanism. 相似文献
5.
Düggeli M Goujon-Ginglinger C Ducotterd SR Mauron D Bonte C von Zelewsky A Stoeckli-Evans H Neels A 《Organic & biomolecular chemistry》2003,1(11):1894-1899
A series of new tetradentate ligands containing two bipyridine groups or two pyridine moieties carrying amine substituents has been synthesised either from 5'- and 6'-substituted chiral bipyridines, or from chiral pyridine derivatives. These precursors have been prepared from (-)-alpha-pinene or (-)-myrtenal, respectively. The structures of three tetradentate-, and of five chiral bipyridine ligands have been determined by X-ray diffraction. 相似文献
6.
Using cyclodextrin capillary zone electrophoresis (CD-CZE), baseline separation of synthetic tetrahydronaphthalenic derivatives, potential melatoninergic compounds, was achieved. A method for the enantioresolution of these tetralins and determination of their enantiomeric purity was developed using anionic CDs (highly sulfated-CD or highly S-CD) as chiral selectors and capillaries dynamically coated with polyethylene oxide (PEO). Operational parameters such as the nature and concentration of the chiral selectors, buffer pH, organic modifiers, temperature and applied voltage were investigated. The use of charged CDs provides a driving force for our neutral compounds in the running buffer and enantiomeric resolution by inclusion of compounds in the CD cavity. The highly S-beta-CD was found to be the most effective complexing agent, allowing good enantiomeric resolution. The complete resolution of three tetralin compounds was obtained using 25 mM phosphate buffer at pH 2.5 containing 2.5% w/v of highly S-beta-CD at 25 degrees C with an applied field of 0.25 kV/cm. The apparent association constants of the inclusion complexes were calculated. This optimized method was validated in terms of linearity, sensitivity, accuracy and recovery. The enantiomeric purity for the three molecules was determined and the detection limit of enantiomer impurities is about 0.3-0.6%. 相似文献
7.
Baseline separation of ten new, substituted [1-(imidazo-1-yl)-1-phenylmethyl)] benzothiazolinone and benzoxazolinone derivatives with one chiral center was achieved using cyclodextrin-capillary zone electrophoresis (CD-CZE). A method for the enantiomeric resolution of these compounds was developed using neutral CDs (native alpha-, beta-, gamma-CDs or alpha-, beta-, gamma-hydroxypropyl (HP)-CDs) as chiral selectors. Operational parameters including the nature and concentration of the chiral selectors, pH, ionic strength, organic modifiers, temperature, and applied voltage were investigated. The use of neutral CDs provides enantiomeric resolution by inclusion of compounds in the CD cavity. The HP-alpha-CD and HP-beta-CD were found to be the most effective complexing agents and allowed efficient enantiomeric resolutions. Optimal separation of N-imidazole derivatives was obtained using 50 mM phosphate buffer at pH 2.5 containing either HP-alpha-CD or HP-beta-CD (7.5-12.5 mM) at 25 degrees C, with an applied field of 0.50 kV.cm(-1) giving resolution factors Rs superior to 1.70 with migration times of the second enantiomer less than 13 min. The same enantiomer migration order observed for all molecules can be related to a close interaction mechanism with CDs. The influence of structural features of the solutes on Rs and tm was studied. The lipophilic character (log kw) of the solutes and the apparent and averaged association constants of inclusion complexes for four compounds with the six different CDs led us to rationalize the enantioseparation mechanisms. The conclusions were corroborated with reversed-phase high-performance liquid chromatography (HPLC) on chiral stationary phases (CSPs) based on CDs. 相似文献
8.
Using cyclodextrin-capillary zone electrophoresis (CD-CZE), baseline separation of baclofen phaclofen, saclofen, and hydroxy-saclofen, potent gamma-aminobutyric acid(B) (GABA(B)) agonist or antagonists was achieved. A method for the enantioresolution of those analogs of GABA was developed using anionic cyclodextrins (highly sulfated CD or highly S-CD) as chiral selectors and capillaries dynamically coated with polyethylene oxide (PEO). With charged CDs we observed good resolutions due to the large electrophoretic mobility of these chiral selectors opposite to the mobility of the solutes. The highly S-alpha-CD and S-beta-CD were found to be complementary and the most effective complexing agent, allowing good enantiomeric resolution in short runtimes. The complete resolution was obtained using 25 mM phosphate buffer at pH 2.5 containing 3% w/v of highly S-alpha-CD or S-beta-CD at 25 degrees C with an applied field of 0.30 kV/cm. The apparent binding constants of the inclusion complexes were evaluated and the migration order was determined. A comparison was possible to investigate the importance of the anionic group of the molecules in the separations. The pK(a) values were determined for all four compounds in order to explain relative electrophoretic migration of the solutes. 相似文献
9.
Analytical HPLC methods for derivatized amylose chiral stationary phases were developed for the direct enantioseparation of substituted [1-(imidazo-1-yl)-1-phenylmethyl)] benzothiazolinone and benzoxazolinone derivatives with one stereogenic center. These analogues of fadrozole constitute new potent nonsteroidal inhibitors of aromatase (P450 arom.). The separations were made using normal phase methodology with mobile phase consisting of n-hexane-alcohol (ethanol, 1-propanol or 2-propanol) in various proportions, and a silica-based amylose tris-3,5-dimethylphenylcarbamate (Chiralpak AD), or tris-(S)-1-phenylethylcarbamate (Chiralpak AS). The effects of concentration of various aliphatic alcohols in the mobile phase were studied. Baseline separation (Rs > 1.5) was easily obtained in all cases, ethanol being often the more interesting modifier. The effects of structural features of the solutes along with the temperature of the column on the discrimination between the enantiomers were examined for different mobile phase compositions. 相似文献
10.