首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
化学   4篇
物理学   1篇
  2020年   1篇
  2018年   1篇
  2016年   1篇
  2014年   2篇
排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
An efficient and widely applicable oxidation method of tribromomethyl carbinols in the presence of pyridinium chlorochromate has been developed with excellent yields up to 96%. This method was well applied for the oxidation of a variety of aromatic, aliphatic, and heterocyclic tribromomethyl carbinols.  相似文献   
2.
3.

We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles that were prepared by direct silylation of magnetic nanoparticles with 3-aminopropyltriethoxysilane-2,4-bis(3,5-dimethylpyrazol)-triazine. The sorbent was characterized by IR spectroscopy, X-ray powder diffraction, scanning electron microscopy, thermal and elemental analysis. The sorbent was applied to the preconcentration of lead and cadmium ions which then were quantified by FAAS. The effects of sample pH value, extraction time, of type, concentration and volume of eluent, and of elution time were optimized. The limits of detection are 0.7 ng mL−1 for Pb(II) ion and 0.01 ng mL−1 for Cd(II). The effects of potentially interfering ions often found in real samples on the recovery in the determination of cadmium and lead ions in real samples were also investigated. The accuracy of the method was confirmed by analyzing the certified reference materials NIST 1571 (orchard leaves) and NIST 1572 (citrus leaves). Finally, the method was successfully applied to the determination of cadmium and lead ions in some fruit samples.

We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles. After optimization of the preconcentration step the method was successfully applied to the determination of cadmium and lead ions in some fruit samples

  相似文献   
4.
5.
We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles that were prepared by direct silylation of magnetic nanoparticles with 3-aminopropyltriethoxysilane-2,4-bis(3,5-dimethylpyrazol)-triazine. The sorbent was characterized by IR spectroscopy, X-ray powder diffraction, scanning electron microscopy, thermal and elemental analysis. The sorbent was applied to the preconcentration of lead and cadmium ions which then were quantified by FAAS. The effects of sample pH value, extraction time, of type, concentration and volume of eluent, and of elution time were optimized. The limits of detection are 0.7 ng mL?1 for Pb(II) ion and 0.01 ng mL?1 for Cd(II). The effects of potentially interfering ions often found in real samples on the recovery in the determination of cadmium and lead ions in real samples were also investigated. The accuracy of the method was confirmed by analyzing the certified reference materials NIST 1571 (orchard leaves) and NIST 1572 (citrus leaves). Finally, the method was successfully applied to the determination of cadmium and lead ions in some fruit samples. Figure
We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles. After optimization of the preconcentration step the method was successfully applied to the determination of cadmium and lead ions in some fruit samples  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号