首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   142篇
  免费   45篇
  国内免费   15篇
化学   152篇
晶体学   7篇
综合类   1篇
物理学   42篇
  2023年   5篇
  2022年   8篇
  2021年   11篇
  2020年   13篇
  2019年   4篇
  2018年   11篇
  2017年   12篇
  2016年   17篇
  2015年   13篇
  2014年   17篇
  2013年   9篇
  2012年   10篇
  2011年   16篇
  2010年   12篇
  2009年   9篇
  2008年   10篇
  2007年   10篇
  2006年   7篇
  2005年   7篇
  2003年   1篇
排序方式: 共有202条查询结果,搜索用时 15 毫秒
31.
32.
A simple optical interference method for the fabrication of simply periodic and periodic with a substructure on poly(3,4-ethylene dioxythiophene)-poly(styrene sulfonate) using femtosecond laser interference patterns is demonstrated. The femtosecond laser pulse was split by a diffractive beam splitter and overlapped with two lenses. Homogeneous periodic arrays could be fabricated even using a single laser pulse. In addition, multipulse irradiation resulted in reproducible sub-wavelength ripples oriented perpendicularly to the laser polarization with spatial period from 170 to 220 nm (around one-fourth of the laser wavelength). In addition, the observed size of the spatial period was not affected by the number of incident laser pulses or accumulated energy density. Using high energy pulses it was possible to completely remove the PEDOT:PSS layer without inducing damage to the underneath substrate.  相似文献   
33.
Summary: Hollow microspheres of PEDOT (poly(3,4-ethylenedioxythiophene) ranging from 0.5 to 10 µm have been synthesized by chemically oxidative polymerization of EDOT(3,4-ethylenedioxythiophene) using ammonium persulfate in a catanionic surfactant solution obtained by mixing cetyltrimethylammonium bromide (CTAB) and sodium dodecylbenzenesulfonate (SDBS). The effect of the molar ratio of CTAB to SDBS on the morphology of the PEDOT oxidation products has been investigated using SEM and TEM and by an analysis of the structural properties using UV-visible, FTIR and Raman spectroscopies, elemental analysis and conductivity measurements. The electro-catalytic activity of PEDOT hollow microspheres for the oxidation of ascorbic acid was investigated by cyclic voltammetry in a pH 6 citrate/phosphate buffer solution and compared to the activity of granular PEDOT particles formed in the absence of the catanionic surfactant.  相似文献   
34.
We report that poly(3,4‐ethylenedioxythiophene) derived from poly(ionic liquid) (PEDOT:PIL) constitutes a unique polymeric hole‐injecting material capable of improving device lifetime in organic light‐emitting diodes (OLEDs). Imidazolium‐based poly(ionic liquid)s were engineered to impart non‐acidic and non‐aqueous properties to PEDOT without compromising any other properties of PEDOT. A fluorescent OLED was fabricated using PEDOT:PIL as a hole‐injection layer and subjected to a performance evaluation test. In comparison with a control device using a conventional PEDOT‐based material, the device with PEDOT:PIL was found to achieve a significant improvement in terms of device lifetime. This improvement was attributed to a lower indium content in the PEDOT:PIL layer, which can be also interpreted as the effective protection characteristics of PEDOT:PIL for indium extraction from the electrodes.

  相似文献   

35.
Electrically conducting poly(3,4‐ethylenedioxythiophene) (PEDOT) film doped with silicomolybdate (SiMo12O404? or SiMo12) was synthesized by electrochemical polymerization. The synthesized film is capable of fast charge propagation during redox reactions in strong acid medium 0.2 M H2SO4 solution. The modified electrode was used towards reduction of bromate and successfully employed as an amperometric sensor for bromate and also above modified electrode was investigated for ascorbic acid oxidation.  相似文献   
36.
Novel poly(3,4‐ethylenedioxythiophene) (PEDOT) polymers bearing imidazolium‐ionic liquid moieties were synthesized by electrochemical polymerizations. For this purpose, new functional monomers were synthesized having an 3,4‐ethylenedioxythiophene (EDOT) unit and an imidazolium‐ionic liquid with different anions such as tetrafluoroborate (BF), bis(trifluoromethane)sulfonimide ((CF3SO2)2N?), and hexafluorophosphate (PF). Next, polymer films were obtained by electrochemical synthesis in dicholoromethane solutions. Obtained polymers were characterized, revealing the characteristics of PEDOT in terms of electrochemical and spectroelectrochemical properties, FTIR, 1H NMR, and AFM microscopy. Interestingly, the hydrophobic character of electropolymerized films could be modified depending on the anion type. The hydrophobicity followed the trend PF > (CF3SO2)2N? > BF > pure PEDOT as determined by water contact angle measurements. Furthermore, the polymers could be dissolved in a range of polar organic solvents such as dimethylformamide, propylene carbonate, and dimethyl sulfoxide making these polymers interesting candidates for wet processing methods. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 3010–3021, 2009  相似文献   
37.
Yasri NG  Halabi AJ  Istamboulie G  Noguer T 《Talanta》2011,85(5):2528-2533
A new simple chronoamperometry methodology was developed for the ultrasensitive determination of lead ions using a PEDOT:PSS coated graphite carbon electrode. The polymer was directly coated on a graphite carbon electrode and characterized using simple cycle voltammetric measurements. The presence of lead ions induced a cathodic peak starting at −550 ± 10 mV vs. Ag/AgCl, and an anodic peak starting at −360 ± 10 mV vs. Ag/AgCl. Electroaccumulation of lead ions onto the PEDOT:PSS modified electrode was performed at −650 mV vs. Ag/AgCl for 30 s in a pH 2.2 hydrochloric acid solution. Chronoamperometry measurements were carried out at −350 mV vs. Ag/AgCl allowing the oxidation of accumulated lead. Using this method, lead ions were detected for concentrations ranging between 2.0 nmol L−1 and 0.1 μmol L−1 (R2 = 0.999). The detection limit was calculated to be 0.19 nmol L−1 and the quantification limit of 0.63 nmol L−1. The method was shown to be highly precise and sensitive, negligible interference was detected from other metal ions. The proposed method was successfully applied for the detection of lead ions in vegetables.  相似文献   
38.
Adopting LB film method, an arachidic acid (AA)/PEDOT multilayer LB film was chosen, and polymerized EDOT monomers in hydrophilic group of LB to prepare arachidic acid (AA)/PEDOT multilayer LB film. UV‐Vis, FT‐IR and XPS analyses implied that EDOT was effectively polymerized in film, and thus PEDOT conducting polymer was produced. Analyses of XRR and SIMS indicated that film had a well‐arranged lamella structure, and further research showed that polymerization of EDOT in AA film destroyed the orderliness of the original LB film. This phenomenon could be related to the destructive effect of polymerization on layered structure. We used four‐point probe and semiconductor instrument to study the conductivity property of the film, and observed that the conductivity of AA/PEDOT film had sudden changes with the processing time of changes in effective conduction network. That was caused by "permeability" in conducting channel of multilayer film. The test results also indicated that the conductivity of AA/PEDOT film was obviously better than that of spin‐coating PEDOT/PSS film or that of ODA‐SA/PEDOT‐PSS film, which was due to the higher π structure of PEDOT structure and ordered film structure.  相似文献   
39.
This study incorporates morphine into a molecularly imprinted polymer (MIP) for the amperometric detection of morphine. The polymer, poly(3,4-ethylenedioxythiophene), PEDOT, is an electroactive film that catalyzes morphine oxidation and lowers the oxidization potential on an indium tin oxide (ITO) electrode. The MIP-PEDOT modified electrode is prepared by electropolymerizing PEDOT onto an ITO electrode in a 0.1 M LiClO4 solution with template addition (morphine). After template molecule extraction, the oxidizing current of the MIP-PEDOT modified electrode is measured in a 0.1 M KCl solution (pH = 5.3) at 0.75 V (versus Ag/AgCl/sat’d KCl) with the morphine concentration varying in the 0.1-5 mM range. A linear range, displaying the relationship between steady-state currents and morphine concentrations, from 0.1 to 1 mM, is obtained. The proposed amperometric sensor could be used for morphine detection with a sensitivity of 91.86 μA/cm2 per mM. A detection limit of 0.2 mM at a signal-to-noise ratio of 3 is achieved. Moreover, the proposed method can discriminate between morphine and its analogs, such as codeine.  相似文献   
40.
Production of high performance conductive textile yarn fibers for different electronic applications has become a prominent area of many research groups throughout the world. We have used oxidative chemical vapor deposition (OCVD) technique to coat flexible and high strength polyester yarns with conjugated polymer, poly(3,4‐ethylenedioxythiophene) (PEDOT) in presence of ferric (III) chloride (FeCl3) oxidant. OCVD is an efficient solvent free technique used to get uniform, thin, and highly conductive polymer layers on different substrates. In this paper, PEDOT‐coated polyester (PET) yarns were prepared under specific reaction conditions, and the electrical, mechanical and thermal properties were compared to previously studied PEDOT‐coated viscose yarns. Scanning electron microscopy (SEM) and FT‐IR analysis revealed that polymerization of PEDOT on the surface of the polyester yarns has been taken place successfully and structural analysis showed that PEDOT has strong interactions with viscose yarns as compared to PET yarns. The voltage–current (VI) characteristics showed that PET yarns are more conductive than PEDOT‐coated viscose yarns. The variation in the conductivity of PEDOT‐coated yarns and the heat generation properties during the flow of current through coated yarns for longer period of time, was studied by time–current (tI) characteristics. Thermogravimeteric analysis (TGA) was employed to investigate the thermal properties and the amount of PEDOT in PEDOT‐coated PET yarns compared to PEDOT‐coated viscose. The effect of PEDOT coating and ferric (III) chloride concentration on the mechanical properties of coated yarns was evaluated by tensile testing. The obtained PEDOT‐coated conductive polyester yarns could be used in smart clothing for medical and military applications. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号