全文获取类型
收费全文 | 288篇 |
免费 | 32篇 |
国内免费 | 20篇 |
专业分类
化学 | 157篇 |
力学 | 9篇 |
数学 | 66篇 |
物理学 | 108篇 |
出版年
2023年 | 3篇 |
2022年 | 4篇 |
2021年 | 4篇 |
2020年 | 3篇 |
2019年 | 1篇 |
2018年 | 6篇 |
2017年 | 12篇 |
2016年 | 10篇 |
2015年 | 20篇 |
2014年 | 26篇 |
2013年 | 32篇 |
2012年 | 21篇 |
2011年 | 24篇 |
2010年 | 11篇 |
2009年 | 19篇 |
2008年 | 9篇 |
2007年 | 10篇 |
2006年 | 12篇 |
2005年 | 7篇 |
2004年 | 14篇 |
2003年 | 11篇 |
2002年 | 20篇 |
2001年 | 13篇 |
2000年 | 15篇 |
1999年 | 12篇 |
1998年 | 9篇 |
1997年 | 4篇 |
1996年 | 3篇 |
1995年 | 2篇 |
1985年 | 2篇 |
1977年 | 1篇 |
排序方式: 共有340条查询结果,搜索用时 46 毫秒
11.
Loubna A. Hammad Matthew Neely Bob Bridge Yehia Mechref 《Journal of separation science》2009,32(14):2369-2376
We describe here the fast LC‐MS/MS separation of a mixture of neurotransmitters consisting of dopamine, epinephrine, norepinephrine, 3,4‐dihydroxybenzylamine (DHBA), salsolinol, serotonin, and γ‐aminobutyric acid (GABA). The new UltiMate® 3000 Rapid Separation system (RSLC) was successfully coupled to the 4000 QTRAP mass spectrometer operating in multiple‐reaction monitoring (MRM) mode. The separation was attained using a 100 mm length, 2.2 μm particle size Acclaim column at a flow rate of 0.5 mL/min. The column back pressure was 350 bar, while the total run time including column re‐equilibration was 5.2 min. The peak resolution was minimally affected by the fast separation. The RSLC‐MRM separation was found to have a precision range based on peak area for 50 replicate runs of 2–5% CV for all analytes, and the reproducibility of the retention time for all analytes was found to range from 0–2% CV. The described method represents an almost seven times shorter analysis time of neurotransmitters using LC/MRM which is very useful in screening large quantities of biological samples for various neurotransmitters. 相似文献
12.
Maria Chiara Pietrogrande Giulia Basaglia Francesco Dondi 《Journal of separation science》2009,32(9):1249-1261
This paper discusses the development of a comprehensive method for the simultaneous analysis of personal care products (PCPs) based on SPE and GC‐MS. The method was developed on 29 target compounds to represent PCPs belonging to different chemical classes: surfactants in detergents (alkyl benzenes), fragrances in cosmetics (nitro and polycyclic musks), antioxidants and preservatives (phenols), plasticizers (phthalates) displaying a wide range of volatility, polarity, water solubility. In addition to the conventional C18 stationary phase, a surface modified styrene divinylbenzene polymeric phase (StrataTM X SPE cartridge) has been investigated as suitable for the simultaneous extraction of several PCPs with polar and non‐polar characteristics. For both sorbents different solvent compositions and eluting conditions were tested and compared in order to achieve high extraction efficiency for as many sample components as possible. Comparison of the behavior of the two cartridges reveals that, overall, Strata‐X provides better efficiency with extraction recovery higher than 70% for most of the PCPs investigated. The best results were obtained under the following operative conditions: an evaporation temperature of 40°C, elution on Strata‐X cartridge using a volume of 15 mL of ethyl acetate (EA) as solvent and operating with slow flow rate (–10 KPa). In addition to the conventional method based on peak integration, a chemometric approach based on the computation of the experimental autocovariance function (EACVFtot) was applied to the complex GC‐MS signal: the percentage recovery and information on peak abundance distribution can be evaluated for each procedure step. The PC‐based signal processing proved very helpful in assisting the development of the analytical procedure, since it saves labor and time and increases result reliability in handling GC complex signals. 相似文献
13.
F. Hosseinzadeh Lotfi T. Allahviranloo M. Alimardani Jondabeh L. Alizadeh 《Applied Mathematical Modelling》2009
This paper discusses full fuzzy linear programming (FFLP) problems of which all parameters and variable are triangular fuzzy numbers. We use the concept of the symmetric triangular fuzzy number and introduce an approach to defuzzify a general fuzzy quantity. For such a problem, first, the fuzzy triangular number is approximated to its nearest symmetric triangular number, with the assumption that all decision variables are symmetric triangular. An optimal solution to the above-mentioned problem is a symmetric fuzzy solution. Every FLP models turned into two crisp complex linear problems; first a problem is designed in which the center objective value will be calculated and since the center of a fuzzy number is preferred to (its) margin. With a special ranking on fuzzy numbers, the FFLP transform to multi objective linear programming (MOLP) where all variables and parameters are crisp. 相似文献
14.
Multi criteria decision making (MCDM) problems are usually under uncertainty. One of these uncertain parameters is the decision maker (DM)’s degree of optimism, which has an important effect on the results. Fuzzy linguistic quantifiers are used to obtain the assessments of this parameter from DM and then, because of its uncertainty it is assumed to have stochastic nature. A new approach, entitled FSROWA, is introduced to combine the Fuzzy and Stochastic features into a Revised OWA operator. 相似文献
15.
Johannes J. Schneider 《Physica A》2010,389(14):2816-2581
Some years ago, Bachem, Hochstättler, and Malich proposed a heuristic algorithm called Simulated Trading for the optimization of vehicle routing problems. Computational agents place buy-orders and sell-orders for customers to be handled at a virtual financial market, the prices of the orders depending on the costs of inserting the customer in the tour or for his removal. According to a proposed rule set, the financial market creates a buy-and-sell graph for the various orders in the order book, intending to optimize the overall system. Here I present a thorough investigation for the application of this algorithm to the traveling salesman problem. 相似文献
16.
A multi‐channel microchip electrophoresis using a programmed step electric field strength (PSEFS) method was investigated for fast parallel detection of feline panleukopenia virus (FPV) DNA. An expanded laser beam, a 10× objective lens, and a charge‐coupled device camera were used to simultaneously detect the separations in three parallel channels using laser‐induced fluorescence detection. The parallel separations of a 100‐bp DNA ladder were demonstrated on the system using a sieving gel matrix of 0.5% poly(ethylene oxide) (Mr = 8 000 000) in the individual channels. In addition, the PSEFS method was also applied for faster DNA separation without loss of resolving power. A DNA size marker, FPV DNA sample, and a negative control were simultaneously analyzed with single‐run and one‐step detection. The FPV DNA was clearly distinguished within 30 s, which was more than 100 times faster than with conventional slab gel electrophoresis. The proposed multi‐channel microchip electrophoresis with PSEFS was demonstrated to be a simple and powerful diagnostic method to analyze multiple disease‐related DNA fragments in parallel with high speed, throughput, and accuracy. 相似文献
17.
A new composite electrode has been fabricated based on coating multi‐walled carbon nanotubes (MWCNTs) and n‐octylpyridinum hexafluorophosphate (OPPF6) ionic liquid composite on a glassy carbon (GC) electrode (OPPF6‐MWCNTs/GCE). This electrode shows very attractive electrochemical performances for electrooxidation of risperidone (RIS) compared to conventional electrodes using carbon and mineral oil, notably improved sensitivity and stability. The oxidation peak potentials in cyclic voltammogram of RIS on the OPPF6‐MWCNTs/GCE was occurred around 230 mV vs. SCE at Britton–Robinson (B–R) buffer (pH 4.0) at scan rate of 100 mV s?1. The electrochemical parameters such as diffusion coefficient (D), charge transfer coefficient (α) and the electron transfer rate constant (k/s) were determined using cyclic voltammetry. Under the optimized conditions, the peak current was linear to risperidone concentration over the concentration range of 10–200 nM with sensitivity of 0.016 μA/nM?1 using differential pulse voltammetry. The detection limit was 6.54 nM (S/N = 3). The electrode also displayed good selectivity and repeatability. In the presence of clozapine (CLZ) the response of RIS kept almost unchanged. Thus this electrode could find application in the determination of RIS in some real samples. The analytical performance of the OPPF6‐MWCNTs/GCE was demonstrated for the determination of RIS in human serum and pharmaceutical samples. 相似文献
18.
The functionalized multi‐wall carbon nanotube with 1,2‐naphthoquinone‐4‐sulfonic acid sodium (Nq‐MWNT) was fabricated by a simple and low‐cost method. Techniques of scanning electron microscope (SEM) with energy dispersive X‐ray (EDX) analysis, fourier transform infrared spectroscopy (FT‐IR), ultraviolet visible spectroscopy (UV‐vis) and cyclic voltammetry (CV) were used to characterize the property of the Nq‐MWNT. The results showed that the MWNT with high functionalization of Nq can be obtained using this simple method. The Nq‐MWNT modified carbon paste electrode (Nq‐MWNT/CPE) was fabricated by drop‐casting technique. The resulted modified electrode was tested successfully to detection D‐penicillamine (D‐PA) and captopril (CAP) in an aqueous solution. It is found that D‐PA and CAP participate in Michael addition reaction with Nq on MWNT to form the corresponding thioquinone derivative. The reoxidation of adducts at a potential of less positive than D‐PA and CAP at the surface of the bare CPE leads to an increase in the oxidative current, which is proportional to the concentration of D‐PA and CAP. The catalytic response showed a wide linear range (3‐200 μM and 1‐130 μM for D‐PA and CAP, respectively) as well as its experimental limit of detection can be achieved 0.8 μM, and 0.4 μM for D‐PA and CAP, respectively. The modified electrode for D‐PA and CAP determination is of the property of simple preparation, good stability and high sensitivity. Furthermore, the fabricated electrode was used to determine the content of D‐PA and CAP in the tablet, suggesting the good accuracy of the method. 相似文献
19.
A novel technique utilizing the adsorptive potential of immobilized multi‐walled carbon nanotubes (I‐MWCNT) in hollow fiber liquid‐phase microextraction (HF‐LPME) was developed for the determination of diuretics in urine. In this study, the potential of carbon nanotubes as a sorbent for three‐phase liquid‐phase microextraction of diuretics from urine samples was evaluated. Analysis was performed using liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). A novel method was applied to detect acetazolamide (AAA), chlorothiazide (CTA), hydrochlorothiazide (HCT), hydroflumethiazide (HFT), clopamide (CA), trichlormethiazide (TCM), althiazide (AT) and bendroflumethiazide (BFT) in urine. Two‐step extractions using different times and temperatures for each step were adopted. Parameters influencing the extraction efficiency, including the extraction solvent, sample pH, salt concentration, extraction time and extraction temperature were systematically optimized. Under the resulting optimal extraction conditions, this method showed good linearity over an analytes concentration range of 1 to 1000 ng/mL, high extraction repeatability with relative standard deviations of less than 6%, and low detection limits (0.09 to 0.51 ng/mL). The application of the methods to the determination of diuretics in real samples was tested by analyzing urine samples of patient. 相似文献
20.
Nourallah Hazeri Malek Taher Maghsoodlou Sayyed Mostafa Habibi‐Khorassani Jasem Aboonajmi Seyed Sajad Sajadikhah 《中国化学会会志》2013,60(4):355-358
Fe(NO3)3·9H2O is used as an efficient and effective catalyst for the one‐pot three‐component synthesis of highly functionalized piperidines from aromatic aldehydes, anilines and b–ketoesters in ethanol at ambient temperature. This procedure includes some important aspects like the easy work‐up, no need to column chromatography, simple and readily available precursors, and good to high yields. 相似文献