首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present work describes the development of a sensitive and reliable analytical method based on solid‐phase extraction followed by analysis using liquid chromatography with tandem mass spectrometry for the simultaneous determination of pharmaceuticals from antibiotics (fluoroquinolones, sulfonamides, and their N4‐acetyl metabolites, and trimethoprim as sulfonamides synergist) and anthelmintics groups. SPE was optimized using different cartridges (Strata‐X, Oasis HLB, Strata C18‐E, Isolute C18, SampliQ C8/Si‐SCX). The highest recovery was achieved using Strata X cartridge (>80%) with good reproducibility (RSDs < 5%) despite various physicochemical properties of the compounds. Investigated analytes were identified and quantitatively determined by liquid chromatography with tandem mass spectrometry using multiple reaction monitoring. The method was shown to be linear over the concentration range of 0.05–30 μg/L for febantel and albendazole, and 0.10–60 μg/L for all other pharmaceuticals. Correlation coefficients were >0.99 for all compounds except for sulfamethazine (0.98). In order to demonstrate the applicability of the developed method, wastewater from the veterinary industry was analyzed. Results evidenced the presence of febantel, praziquantel, albendazole, enrofloxacin, sulfamethazine, and sulfadiazine.  相似文献   

2.
A drying cartridge was used and optimized for the in-line elimination of water from the desorption eluent in on-line solid phase extraction–gas chromatography (SPE–GC). The cartridge is essentially a small stainless-steel precolumn packed with a drying agent which can be regenerated by simultaneous heating and purging with a moisture-free gas. The drying cartridge was mounted on an additional valve instead of between the SPE–GC transfer valve and the on-column injector to enable regeneration of the cartridge during the GC run and, thus, to increase sample throughput. Three drying agents were tested, viz. sodium sulfate, silica, and molecular sieves. Although molecular sieves have the highest capacity, silica was preferred because of practical considerations. Large-volume injections were performed through the in-line drying cartridge using a mixture of 23 microcontaminants ranging widely in polarity and volatility. Four solvents were tested. With pentane and hexane, the more polar analytes were retained by the drying cartridge. Ethyl acetate and methyl acetate gave much better (and closely similar) recoveries for all analytes. Because water elimination on the silica cartridge proved to be less critical than with ethyl acetate, this solvent was finally selected. The entire SPE–drying cartridge–GC set-up was combined with mass spectrometric (MS) detection for the determination of a mixture of micropollutants in real-life water samples. With 10-ml tap water samples spiked at the 0.5 μg/l level, for the majority of the test compounds the analyte recoveries generally were 60–106%, and (full-scan) detection limits typically were 0.01–0.03 μg/l. Some very polar analytes such as, e.g. dimethoate, were (partially) sorbed onto the silica packing of the drying cartridge.  相似文献   

3.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

4.
In recent years, the use of human saliva for diagnostic purposes has evoked great interest. Thus, the aim of this study was to choose the optimal solid‐phase extraction cartridges and extraction solvents for the quantitation of venlafaxine in saliva. Blank saliva samples spiked with venlafaxine concentrations between 25 and 750 ng/mL were analyzed using five solid‐phase extraction columns (C18, C8, Strata‐X, Strata‐X‐C, and Strata‐X‐AW), washing solvents (deionized water, phosphate buffer at pH 5.5, and their mixtures with methanol), and elution solvents (methanol, acetonitrile, and their mixtures with 25% ammonia). A high‐performance liquid chromatography system was used to quantify venlafaxine in saliva. The results of this study revealed that nine of 25 procedures enabled quantitation of venlafaxine in the tested concentration range. The procedure that used a C18 cartridge, a mixture of methanol and deionized water as the washing solvent, and methanol as the elution solvent was the most effective and allowed quantitation of all venlafaxine concentrations with an acceptable recovery. In contrast, the Strata‐X‐C cartridge could not detect venlafaxine at the lowest concentration (25 ng/mL). The data acquired from the high‐performance liquid chromatography system were confirmed by a multivariate data analysis.  相似文献   

5.
Presence of matrix ions could negatively affect the sensitivity and selectivity of liquid chromatography‐tandem mass spectrometer (LC‐MS/MS). In this study, the efficiency of a miniaturized silica monolithic cartridge in reducing matrix ions was demonstrated in the simultaneous extraction of morphine and codeine from urine samples for quantification with LC‐MS. The miniaturized silica monolith with hydroxyl groups present on the largely exposed surface area function as a weak cation exchanger for solid phase extraction (SPE). The miniaturized silica cartridge in 1 cm diameter and 0.5 cm length was housed in a 2‐ml syringe fixed over a SPE vacuum manifold for extraction. The cleaning effectiveness of the cartridge was confirmed by osmometer, atomic absorption spectrometer, LC‐MS and GC‐TOFMS. The drugs were efficiently extracted from urine samples with recoveries ranging from 86% to 114%. The extracted analytes, after concentration and reconstitution, were quantified using LC‐MS/MS. The limits of detection for morphine and codeine were 2 ng/ml and 1 ng/mL, respectively. The relative standard deviations of measurements ranged from 3% to 12%. The monolithic sorbent offered good linearity with correlation coefficients > 0.99, over a concentration range of 50–500 ng/ml. The silica monolithic cartridge was found to be more robust than the particle‐based packed sorbent and also the commercial cartridge with regards to its recyclability and repeated usage with minimal loss in efficiency. Our study demonstrated the efficiency of the miniaturized silica monolith for removal of matrix ions and extraction of drugs of abuse in urinary screening. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Solid-phase extraction of soy isoflavones   总被引:3,自引:0,他引:3  
An automated method using solid-phase extraction (SPE) for the concentration and clean-up of soy isoflavone extracts is proposed in this work. Using a standardized sample (0.1 g of a freeze dried soybean extract/25 mL of water); eight SPE cartridges with a wide range of sorbents (C18, divinylbenzene and modified divinylbenzene) from different suppliers were evaluated and compared. A large variation on SPE cartridges performance was observed, especially regarding retention and breakthrough volume of isoflavones during sample load and washing steps. The most effective cartridges were the divinylbenzene based cartridges, especially Strata X (from Phenomenex) and HLB oasis (from Waters). Using Strata X cartridges, several extraction parameters, such as sample loading flow (5-15 mL min(-1)), extracting solvent volume (2-6 mL of methanol), pH of the extracting solvent and the necessity of drying the sorbent before elution, were evaluated to provide a fast, specific, quantitative and reproducible SPE method. The optimized method consists of conditioning the cartridge with 10 mL of methanol and 10 mL of water (10 mL min(-1)), loading 25 mL of the standardized extract onto the cartridges (5 mL min(-1)), washing the cartridge with 10 mL of water (10 mL min(-1)) and finally eluting with 4 mL of methanol (10 mL min(-1)). Mean isoflavones recovery was 99.37% and mean intra- and inter-day reproducibility was higher than 98%. The developed sample clean-up/concentration (6.25:1) method takes less than 10 min and can be used in the analysis of isoflavones from soy extracts.  相似文献   

7.
An LC‐MS/MS method developed for simultaneous analysis of 54 veterinary drug residues of six families in pork meat samples, including sulfanilamide, nitroimidazoles, quinolones, macrolide antibiotics, lincosamides, and praziquantel. The pork meat sample was prepared by extraction with ACN, and clean‐up on a C18 SPE cartridge. The sample was separated on a C8 column and eluted with ACN, methanol, and formic acid. The MS/MS detector is operated in the multiple reaction monitoring mode, acquiring two specific precursor‐product ion transitions per target compound. The method showed excellent linearity (R2 ≥ 0.99) and high precision (relative SD, RSD ≤ 19.8%) for all compounds. The method quantification limits of 54 veterinary drug residues were in the range of 0.3–3.0 μg/kg. Recoveries for most analytes based on matrix‐matched calibration in matrices were 20.9–121.0%. This method has been successfully applied for analysis of more than 100 pork meat samples from the local market; five of the 54 drugs were detected.  相似文献   

8.
A procedure based on solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with diode array detection has been developed for the simultaneous analysis of 16 widely used pesticides in groundwater samples. The compounds analysed were: aldicarb, atrazine, desethylatrazine, desysopropylatrazine, carbofuran, 2,4-D, dicloran, fenitrothion, iprodione, linuron, metalaxyl, metazachlor, phenmedipham, procymidone, simazine and vinclozolin. Five different SPE sorbents, C18 bonded silica (Isolute SPE C18 (EC)), graphitised carbon black (Superclean Envi-Carb), highly cross-linked polystyrene-divinylbenzene (Lichrolut EN), divinylbenzene-N-vinylpyrrolidone (Oasis HLB) and surface modified styrene-divinylbenzene (Strata X), were compared. HPLC separation and quantification of the selected pesticides was carried out under isocratic conditions by means of a new reversed-phase column (Gemini from Phenomenex) based on C18 bonded to organic-silica particles. Oasis HLB and Strata X provided the best results in the preconcentration of 1-l samples, yielding average recoveries higher than 70%, except for phenmedipham that rapidly degrades in groundwater. Detection limits of the target pesticides provided by the proposed SPE-HPLC procedure were between 0.003 and 0.04 μg l−1.  相似文献   

9.
固相萃取-气相色谱/质谱法同时测定涂料中的8种有机锡   总被引:6,自引:0,他引:6  
建立了一种固相萃取(SPE)前处理、气相色谱-质谱(GC-MS)法同时测定涂料中8种有机锡的方法。样品采用阳离子交换固相萃取小柱净化,最佳固相萃取条件为:固相萃取小柱分别用5mL甲醇、7mL洗脱液(氯化铵、甲醇、冰乙酸的混合溶液)预洗,10mL甲醇活化;将用甲醇稀释的涂料样品上样后,用5mL甲醇淋洗,抽干2min,7mL乙酸-氯化铵甲醇溶液(10:90,V/V)洗脱溶液洗脱。洗脱液用四乙基硼化钠溶液衍生后,气相色谱-质谱法进行定性定量分析。结果表明:以标准加入法计算回收率,在1.68%-16.84%添加范围内,平均回收率在85%-105%之间,相对标准偏差均小于12%。  相似文献   

10.
A sensitive and reliable method based on MEKC has been developed and validated for trace determination of neonicotinoid insecticides (thiamethoxam, acetamiprid, and imidacloprid) and the metabolite 6‐chloronicotinic acid in water and soil matrices. Optimum separation of the neonicotinoid insecticides was obtained on a 58 cm long capillary (75 μm id) using as the running electrolyte 40 mM SDS, 5 mM borate (pH 10.4), and 5% (v/v) methanol at a temperature of 25°C, a voltage of 25 kV and with hydrodynamic injection (10 s). The analysis time was less than 7 min. Prior to MEKC determination, the samples were purified and enriched by carrying out extraction‐preconcentration steps. For aqueous samples, off‐line SPE with a sorptive material such as Strata‐X (polymeric hydrophobic sorbent) and octadecylsilane (C18) was carried out to clean up and preconcentrate the insecticides. However, for soil samples, matrix solid‐phase dispersion (MSPD) was applied with C18 used as the dispersant. Good linearity, accuracy, and precision were obtained and the detection limits were in the range between 0.01 and 0.07 μg mL?1 for river water and 0.17 and 0.37 μg g?1 for soil samples. Recovery levels reached greater than 92% for all of the assayed neonicotinoids in river water samples with Strata‐X. In soil matrices, the best recoveries (63–99%) were obtained with MSPD.  相似文献   

11.
In this work, for the first time, headspace (HS) single‐drop microextraction and simultaneous derivatization followed by GC‐MS was developed to determine the aliphatic amines in tobacco samples. In the HS extraction procedure, the mixture of derivatization reagent and organic solvent was employed as the extraction solvent for HS single‐drop microextraction and in situ derivatization of aliphatic amine in the samples. Fast extraction and simultaneous derivatization of the analytes were performed in a single step, and the obtained derivatives in the microdrop extraction solvent were analyzed by GC‐MS. The optimized experiment conditions were: sample preparation temperature of 80°C and time of 30 min, HS extraction solvent (the mixture of benzyl alcohol and 2,3,4,5,6‐pentafluorobenzaldehyde) volume of 2.0 μL, extraction time of 90 s. With the optimal conditions, the method validations were also studied. The method has good linearity (R2 more than 0.99), accepted precision (RSD less than 13%), good recovery (98–104%) and low limit of detection (0.11–0.97 μg/g). Finally, the proposed technique was successfully applied to the analyses of aliphatic amines in tobacco samples of seven different brands. It was further demonstrated that the proposed method offered a simple, low‐cost and reliable approach to determine aliphatic amines in tobacco samples.  相似文献   

12.
An analytical method for the simultaneous screening of three antiviral agents (nevirapine, zidovudine, lamivudine), four antibiotics (sulfamethoxazole, trimethoprim, ciprofloxacin, rifampicin) and one reference compound (carbamazepine) in human urine was developed. Separation was achieved with a Kinetex XB‐C18 (75 × 4.6 mm, 2.6 μm) column after the extraction of pharmaceuticals from urine with SPE. Gradient elution with a mobile phase consisting of acetonitrile and 10 mM KH2PO4 (pH 2.5), and diode array detection with monitoring at 210 and 264 nm was applied. The developed method was validated in terms of selectivity, linearity, stability and sensitivity. Repeatability (n = 3) and between‐day precision (n = 3) revealed RSD <5%. The detection limits were estimated as 0.02–0.54 g/L (depending on compound). The method was validated for human urine and successfully applied to the simultaneous quantification of selected compounds. Strata‐X cartridges provided good recoveries ranging from 81 to 109%. The limits of detection for urine varied between 0.04 and 1.61 g/L. The method is suitable for the fast determination of selected pharmaceuticals from source‐separated urine samples for further environmental risk assessment and degradation potential evaluation. It provides a way to enhance safe nutrient recycling from wastewater streams and promotes the safe use of urine as fertiliser.  相似文献   

13.
This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norfloxacin and penicillin G/procaine. Five different SPE materials (Strata‐X, Strata‐X‐C, Strata SDB‐L, Strata C8 and Strata C18) from Phenomenex were compared with Oasis HLB with a view to obtaining the best cartridges for all pharmaceuticals investigated. Extraction efficiency was determined by HPLC with diode array detection (DAD). HPLC‐DAD separation and quantification of the selected pharmaceuticals were carried out under gradient elution by a binary mixture of 0.01 M oxalic acid and ACN based on cyano modified column (LiChrosphere 100 CN) from Merck. Strata‐X provided the best results in the preconcentration of 100 mL water samples, yielding average pharmaceutical recoveries of higher than 90%, except for sulfaguanidine (76.1%). The developed Strata‐X‐HLPC‐DAD method was validated and applied, for the efficient investigation of reverse osmosis/nanofiltration membranes and for the removal of these eight pharmaceuticals from the production wastewater samples. NF90 and XLE membranes were shown to be the best for the rejection of all investigated pharmaceuticals.  相似文献   

14.
15.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

16.
This study compares the separation performance of a group of iodinated X‐ray contrast media on four different columns. The first three were two stationary phases (SPs) modified with C18 and a polar‐embedded SP (polar amide group bonded to an alkyl chain), all of which worked under RP‐LC mode. The fourth was a zwitterionic sulphoalkylbetaine SP, working under the hydrophilic interaction LC (HILIC) mode. After the optimisation of the different parameters, the zwitterionic column displayed the best separation, which also overcomes the problems encountered when these analytes were separated under RP‐LC. Moreover, when HILIC is coupled to MS/MS, sensitivity is enhanced. However, when sewage samples were analysed by SPE followed by the optimal HILIC–MS/MS, the sensitivity of the method was affected due to the high matrix effect, which had to be solved by dilution of the extract. Finally, the method was preliminarily validated with sewage and the figures of merit were comparable to those of the SPE–RP‐LC–MS/MS.  相似文献   

17.
建立了尿样中甲基膦酸单乙酯(EMPA)、甲基膦酸单异丙酯(IMPA)、甲基膦酸频哪基酯(PMPA)3种神经性毒剂代谢产物的HPLC/Q-TOFMS/MS检测方法。以StrataSi-1型固相萃取小柱对尿样中的3种神经性毒剂代谢产物进行分离,HPLC/Q-TOFESIMS/MS进行测定,内标法定量。该方法对EMPA、IMPA、PMPA的线性范围均为5~320μg/L,相关系数均不低于0.9974;EMPA、IMPA、PMPA的加标回收率分别为57%、98%、81%;检出限(S/N≥3)均为0.1μg/L,定量下限(S/N≥10)均为1μg/L。并将该方法应用于禁化武组织(OPCW)首次生物医学样品分析演练未知尿样的检测,结果满意。  相似文献   

18.
In this study, a specific and sensitive LC–MS/MS method for the simultaneous analysis of type‐B trichothecenes (deoxynivalenol, 3‐acetyldeoxynivalenol, and 15‐acetyldeoxynivalenol) and the de‐epoxy metabolite of deoxynivalenol (de‐epoxy‐deoxynivalenol) in chicken muscle, liver, kidney, and fat tissues was developed and validated. The method involved an extraction step using ethyl acetate, followed by the evaporation of the supernatant, which was further purified by an Oasis HLB SPE cartridge (Waters, Milford, MA, USA). Chromatographic separation was performed on a C18 column by detection with MS in multiple‐reaction monitoring mode and using a gradient elution program with 0.1% formic acid in water and methanol. The correlation coefficients (r) for each calibration curve were >0.99 within the experimental concentration range. The extraction recoveries ranged from 73.7 to 106.4%, with intraday and interday RSD < 11.6% at three levels of concentrations of 2, 10, and 100 μg/kg. The decision limits and the detection capabilities of the analytes in the chicken tissues ranged from 0.16 to 0.92 and 0.68 to 2.07 μg/kg, respectively. The results demonstrated the applicability of this sensitive procedure to the determination of trichothecenes in chicken tissue samples.  相似文献   

19.
Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid‐phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18‐E), benzenesulfonic acid modified silica cation exchanger (SA), poly(styrene‐divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18‐E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries > 70% with standard deviations (SD) < 15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC‐MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′‐DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
液相色谱-串联质谱法同时检测饲料中7种精神类药物   总被引:1,自引:0,他引:1  
建立了液相色谱-串联质谱同时检测饲料样品中7种精神类药物(硝西泮、奥沙西泮、氯丙嗪、异丙嗪、地西泮、奋乃静、硫利达嗪)的方法.通过对提取溶剂、净化等预处理条件及LC-MS/MS 分析条件的优化,可以同时检测饲料中7种违禁精神类药物.饲料样品经乙腈/水(9:1, V/V)提取后,过MCX固相萃取柱净化,氮吹至干,用1 mL乙腈/水(2:8, V/V)溶解后测定,采用SRM模式进行定性与定量分析.7种精神类药物在饲料中的回收率为53.9%~110.2%; 相对标准偏差为3.4%~18.4%;硝西泮、奥沙西泮、氯丙嗪、异丙嗪的检出限为1.0 ng/g;对地西泮、奋乃静、硫利达嗪的检出限为5.0 ng/g.结果表明,本方法可用于饲料中7种精神类药物的测定.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号