全文获取类型
收费全文 | 1534篇 |
免费 | 85篇 |
国内免费 | 21篇 |
专业分类
化学 | 335篇 |
晶体学 | 1篇 |
力学 | 24篇 |
综合类 | 1篇 |
数学 | 7篇 |
物理学 | 1272篇 |
出版年
2024年 | 1篇 |
2023年 | 79篇 |
2022年 | 116篇 |
2021年 | 159篇 |
2020年 | 146篇 |
2019年 | 12篇 |
2018年 | 55篇 |
2017年 | 98篇 |
2016年 | 109篇 |
2015年 | 35篇 |
2014年 | 161篇 |
2013年 | 48篇 |
2012年 | 105篇 |
2011年 | 54篇 |
2010年 | 60篇 |
2009年 | 55篇 |
2008年 | 59篇 |
2007年 | 52篇 |
2006年 | 33篇 |
2005年 | 44篇 |
2004年 | 35篇 |
2003年 | 27篇 |
2002年 | 16篇 |
2001年 | 11篇 |
2000年 | 17篇 |
1999年 | 11篇 |
1998年 | 7篇 |
1997年 | 14篇 |
1996年 | 9篇 |
1995年 | 6篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
排序方式: 共有1640条查询结果,搜索用时 15 毫秒
61.
In this study, the decomposition of struvite by ultrasound stripping and the recycle use of the decomposition product for the treatment of landfill leachate were investigated. The results indicated that when the decomposition of struvite by ultrasound stripping was performed at 55 °C for 40 min, the ammonium in the struvite could be almost completely eliminated from the solution system. The characterization analysis showed that magnesium phosphate and the dissolved phosphate ions were the main active derivatives. Approximately 90% of the total ammonia nitrogen (TAN) in landfill leachate can be removed by reusing the decomposition product at pH 9 for 60 min. Repeated use of the struvite decomposition product revealed that the TAN removal efficiency decreased with an increase in the number of recycles. However, in the process of multiple recycling, about 90% of TAN removal could be maintained by supplementing a certain amount of the preformed struvite to the solution for every recycle. An economic analysis demonstrated that 79.3% of the treatment cost could be saved by the proposed process compared to the non-recycling process. 相似文献
62.
Encapsulation of materials in particles dispersed in water has many applications in nutritional foods, imaging, energy production and therapeutic/diagnostic medicine. Ultrasonic technology has been proven effective at creating encapsulating particles and droplets with specific physical and functional properties. Examples include highly stable emulsions, functional polymeric particles with environmental sensitivity, and microspheres for encapsulating drugs for targeted delivery. This article provides an overview of the primary mechanisms arising from ultrasonics responsible for the formation of these materials, highlighting examples that show promise particularly in the development of foods and bioproducts. 相似文献
63.
Acoustic test objects are commonly used for quality assurance testing of diagnostic ultrasound machines. However, the accompanying calibration protocols rely heavily on the judgment of the sonographer, are dependent on machine settings and are semi-quantitative. In the current study, two unique test objects and protocols were designed to quantitatively determine diagnostic ultrasound parameters, namely axial resolution and geometric uniformity, and lateral resolution and geometric uniformity of the ultrasound field. The effect of focal zone, signal gain, and distance from the ultrasound probe on these parameters was assessed. The investigation was performed using a typical low-frequency diagnostic unit equipped with a 7.5 MHz linear pulse–echo probe. Results underline the need to ensure that sensitivity of routine testing regimes is adequate for the measurements to be made. This study is a preliminary part of a larger project developing an ultrasound technique to be used as an engineering design tool in a non-clinical industrial setting for quality assurance testing of total knee replacements immersed in water. 相似文献
64.
65.
Dilute aqueous solutions of dodecyl-benzenesulfonic acid sodium salt (DBS-Na) and polyoxyethylenenonylphenyl ethers (PONPEs) were ultrasonically atomized. The surfactants were concentrated in collected mist droplets. The enrichment ratio increased with decreasing surfactant concentration. Depending on the surfactant’s molecular weight and affinity to water, different enrichment ratio was observed in the range of low feed concentrations. For anionic surfactant, DBS-Na, the enrichment ratio was significantly improved by KCl addition and a peak appeared on the plot of the ratio against KCl concentration. Addition of NaCl or CaCl2 · 2H2O to the surfactant solution also enhanced the enrichment ratio; however, the effect was relatively small. Such behaviors of the ratio were interpreted as enhanced interfacial adsorption of the surfactant and a lack of supply of surfactant monomers from liquid bulk because of slow breaking of surfactant micelles. Time required for collecting an amount of mist was also observed. Among the three salt systems, the time for KCl system was twice as long as others. This fact suggested that the formation of smaller droplets in KCl system. 相似文献
66.
Nonlinear contrast imaging modes such as second harmonic imaging (HI) and subharmonic imaging (SHI) are increasingly important for clinical applications. However, the performance of currently available transducers for HI and SHI is significantly constrained by their limited bandwidth. To bypass this constraint, a novel transducer concept termed multi-frequency harmonic transducer arrays (MFHA's) has been designed and a preliminary evaluation has been conducted. The MFHA may ultimately be used for broadband contrast enhanced HI and SHI with high dynamic range and consists of three multi-element piezo-composite sub-arrays (A-C) constructed so the center frequencies are 4f(A) = 2f(B) = f(C) (specifically 2.5/5.0/10.0 MHz and 1.75/3.5/7.0 MHz). In principle this enables SHI by transmitting on sub-array C receiving on B and, similarly, from B to A as well as HI by transmitting on A receiving on B and, likewise, from B to C. Initially transmit and receive pressure levels of the arrays were measured with the elements of each sub-array wired in parallel. Following contrast administration, preliminary in vitro HI and SHI signal-to-noise ratios of up to 40 dB were obtained. In conclusion, initial design and in vitro characterization of two MFHA's have been performed. They have an overall broad frequency bandwidth of at least two octaves. Due to the special design of the array assembly, the SNR for HI and SHI was comparable to that of regular B-mode and better than commercially available HI systems. However, further research on multi-element MFHA's is required before their potential for in vivo nonlinear contrast imaging can be assessed. 相似文献
67.
Structural change of mesoporous silica with sonochemically prepared gold nanoparticles in its pores 总被引:1,自引:0,他引:1
Ultrasonic irradiation of mesoporous silica soaked in a mixture of chloroauric acid and isopropanol for 120 min in Ar atmosphere at room temperature yielded Au/SiO2 mesoporous composite, which was characterized by high resolution transmission electron microscopy and optical absorption measurement. The structure of mesoporous silica after sonochemical preparation of gold (Au) nanoparticles within its pores was studied by nitrogen adsorption technique. It has been shown that the structural parameters, such as specific surface area (SSA), porosity (P), the mean pore diameter (lp) were increased significantly after ultrasonic irradiation. It is suggested that the collision of Au nanoparticles with pore walls and localized erosion induced by the asymmetric implosive collapse of cavities on the extensive liquid–solid interface that are responsible for the structural change in the mesoporous solid. 相似文献
68.
Silver-decorated silica spheres of submicrometer-sized silica spheres with a core-shell structure were obtained based on a seed-mediated growth process, where silver nanoparticles were firstly formed from reducing Ag+ to Ag0 in N,N-dimethylformamide (DMF) in the presence of poly(vinylpyrrolidone) (PVP) as protective agent under ultrasound irradiation, followed by the growth of silver shell served silver nanoparticles as nucleation sites and formaldehyde as reducer. The results revealed that the terms of PVP addition and ultrasonic surroundings had great influence on the fabrication of silver seeds. 相似文献
69.
Haydar Aygün Keith Attenborough Walter Lauriks Philip A. Rubini Christian M. Langton 《Applied Acoustics》2011,(7):458-463
Comparisons between predictions of a Biot-Allard model allowing for angle-dependent elasticity and angle-and-porosity dependent tortuosity and transmission data obtained at normal incidence on water-saturated replica bones are extended to oblique incidence. The model includes two parameters which are adjusted for best fit at normal incidence. Using the same parameter values, it is found that predictions of the variation of transmitted waveforms with angle through two types of bone replica are in reasonable agreement with data despite the fact that scattering is not included in the theory. 相似文献
70.
K. Araki T. Yoshikawa I. Ishii T. Goto H. Tanida B. Lüthi 《Physica B: Condensed Matter》2009,404(19):3187-3190
We performed ultrasonic measurements on a single crystal of PrMg3. The characteristic Curie-type softening was observed in temperature dependence of transverse mode (C11-C12)/2 below 8 K down to 0.8 K. This softening in PrMg3 is caused by a non-Kramers Γ3 doublet ground state having electric quadrupoles Ou and Ov and magnetic octupole Txyz. The elastic constant (C11-C12)/2 shows a minimum at 25 K, which cannot be explained by the quadrupole susceptibility based on the crystal electric field (CEF) levels. However, considering higher order (l=4) multipole, namely electric hexadecapole, the minimum around 25 K was well reproduced. At lower temperatures, a shoulder anomaly in elastic constant being deviated from the Curie-type softening was observed around 100-800 mK in (C11-C12)/2. This anomaly is unaffected by magnetic fields up to 14 T. 相似文献