Densities of boldine + alcohol binary mixtures were measured over the whole accessible range of boldine compositions at temperatures from 283.15 to 333.15 K using an Anton-Paar digital vibrating glass tube densimeter. The binary systems studied include, as a solvent, seven normal alcohols from n-C1 to n-C6, n-C8, and isopropanol. The density of these systems has been found an increasing function of the boldine composition. A new methodology based on density data of solutions of solid solutes with normal alcohols is described in order to determine solid molar volume of pure solutes. This methodology was validated with pure solid naphthalene molar volumes data at 298.15 K, with an average uncertainty of 6%. 相似文献
The concentration sensitivity of a thermal conductivity detector (TCD) depends, among other factors, on the amount of sample mixture in the detector's sensing cell. Since the cell volume has to be appropriately matched with column diameter, it makes the concentration sensitivity of a TCD dependent on column diameter and, therefore, on the speed of gas chromatography. Through reduction of column diameter, higher speed tends to lead to a reduction in the concentration sensitivity of the cell. The factor which the most directly affects the concentration sensitivity of a TCD cell is the heat power conducted through the cell. The higher the power, the greater the sensitivity. The limit of detection of a TCD depends on the concentration-sensitivity of its cell and on the level of statistical errors in the measurement. The errors increase with increasing analysis speed. As the column diameter is reduced, the errors cause additional worsening (on top of the decrease in concentration sensitivity) of the detection limit, dynamic range, and other performance characteristics of the TCD. 相似文献
The substantiation and the area of applicability of the Dubinin—Radushkevich equation for determination of the micropore volume
in microporous systems from experimental data on adsorption isotherms were examined. It was shown that the micropore volumes
found using the standard procedure are overestimated. A more accurate method for determining the mircopore volumes based on
the pressure of filling of micropores was proposed.
Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 4, pp. 659–664, April, 1998. 相似文献
The refractive index, nD, and density, ρ, of binary mixtures of monoalcohols + water, have been measured at a temperature of 298.15,K and atmospheric pressure. The variation of the refractive indices of these solutions has also been determined with temperature in the range T = (278.15 to 338.15) K and atmospheric pressure. A comparative study has been made of the refractive indices obtained experimentally and those calculated by means of the Lorentz-Lorenz [Theory of Electrons, Dover Phoenix (1952)] and Gladstone-Dale relations [Trans. R. Soc. London 148:887–902 (1858)]; in all cases, the Gladstone–Dale equation was seen to afford values similar to those obtained experimentally. Calculations have been made of the excess molar volumes, VE, and the molar refraction deviations, ΔR, of these mixtures and the differences between the experimental values for refractive index and those obtained by means of the Gladstone–Dale equation. Values of VE were compared with others in the literature. In all cases the VE values were negative, and in all cases, except in the methanol + water, ΔR showed a maximum for x = 0.8. 相似文献
A geometrical method is suggested for representing a molecule by a smoothed region. The effective volume and surface area are calculated, which results in more adequate proportionality of interactant molecules compared to the classical van der Waals models. 相似文献
From conductance and viscosities measurements on Pr4NCl, Et4NBr, and AgNO3 in acetonitrile and Et3NBr in nitrobenzene, the Walden products of the anion at infinite dilution were determined in presence of various concentrations of substituted benzoic acids. From these data it was possible to compute the values of the Walden products of the once complexed anions and to estimate the order of magnitude of the Walden products of twice complexed anions. Stokes' law is not obeyed, and the Walden products are not proportional to the third root of the molar volume of the complexed ions, as a consequence of their lack of sphericity. The assumption that the drag force which acts on the ions is proportional to the volume of the substituents results in a linear expression between the reciprocals of the Walden products and the molar volume of the ligands. The experimental results fit this expression within the limits of the experimental errors, and the slopes of the lines are nearly the same for all the anions and for the two solvents studied here, namely, 2.5×10–4 ohm-cm–5 mole-cP–1. 相似文献
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.
An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ1=μ2=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. 相似文献
The θ/2 method, a widely used technique on measuring the contact angle of a sessile drop, assumes that the drop profile is part of a sphere. However, the shape profile of a sessile drop is governed by the Young–Laplace equation and is different from a sphere, especially for drops with a large bound number (e.g. large volume or small surface tension). The spherical assumption, therefore, causes errors on evaluating the contact angles. The deviation of contact angle from the θ/2 method is evaluated from a theoretical calculation in this work. A simple means is given for correcting the measurement error. The corrected angle results from the drop volume, surface tension, liquid density and the contact angle from θ/2 method. An algorithm for finding the correct contact angle without knowing the density and surface tension is also given. At the end, two examples of pendant drops are given for the illustration. 相似文献
The diffusion of six azo and five anthraquinone derivatives through nylon 6, poly(ethylene terephthalate) and secondary cellulose acetate films were studied under high hydrostatic pressures of up to 3000 bar and at temperatures 80–130 °C, by analyzing the diffusion profiles yielded in a stacked multiple film, placed in the solution of the diffusant. It was found that the diffusion coefficient,D, of the diffusant decreased with increasing pressure, giving a linear relationship between InD and the pressure, the slope of which gave the activation volume for the diffusion,V. It was revealedV increased linearly with increasing intrinsic molecular volume of the diffusant,Vw, the slopes being different between the azo and the anthraquinone derivatives. The ratio ofV toVw (V/Vw) ranged from 0.13 to 0.93, depending in a sensitive manner on the degree of swelling of the polymer matrix which in turn was varied by the solvent. The overall results could be explained in accordance with the formulation,Vf, local +V=Vw, whereVf, local represents the free volume contribution. It was proposed thatVw is increased by solvation when the solvent is good for the diffusant. 相似文献