首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   115篇
  免费   4篇
  国内免费   15篇
化学   119篇
物理学   15篇
  2023年   2篇
  2022年   7篇
  2021年   7篇
  2020年   7篇
  2019年   4篇
  2018年   3篇
  2017年   5篇
  2016年   5篇
  2015年   3篇
  2014年   4篇
  2013年   4篇
  2012年   9篇
  2011年   9篇
  2010年   4篇
  2009年   11篇
  2008年   9篇
  2007年   5篇
  2006年   8篇
  2005年   3篇
  2004年   6篇
  2003年   1篇
  2002年   3篇
  2001年   2篇
  2000年   1篇
  1998年   1篇
  1997年   2篇
  1995年   1篇
  1993年   2篇
  1992年   3篇
  1991年   1篇
  1989年   1篇
  1986年   1篇
排序方式: 共有134条查询结果,搜索用时 216 毫秒
101.
Zhang J  Zhang Z  Xiang Y  Dai Y  Harrington Pde B 《Talanta》2011,84(5):1401-1409
A sequential injection analysis (SIA) spectrophotometric method for determining tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC) in different sample matrices were described. The method was based on the reaction between tetracyclines and yttrium (III) in weak basic micellar medium, yielding the light yellow complexes, which were monitored at 390, 392 and 395 nm, respectively. A cationic surfactant, cetyltrimethylammonium bromide (CTAB) was used to obtain the micellar system. The linear ranges of calibration graphs were between 1.0 × 10−5 and 4 × 10−4 mol L−1, respectively. The molar absorptivities were 5.24 × 105, 4.98 × 104 and 4.78 × 104 L mol−1 cm−1. The detection limits (3σ) were between 4.9 × 10−6 and 7.8 × 10−6 mol L−1 whereas the limit of quantitations (10σ) were between 1.63 × 10−5 and 2.60 × 10−5 mol L−1 the interday and intraday precisions within a weak revealed as the relative standard deviations (R.S.D., n = 11) were less than 4%. The method was rapid with a sampling rate of over 60 samples h−1 for the three drugs. The proposed method has been satisfactorily applied for the determination of tetracycline and its derivatives in pharmaceutical preparations together with their residues in milk and honey samples collected in Chiang Mai Province. The accuracy was found to be high as the Student's t-values were found to be less than the theoretical ones. The results were compared favorably with those obtained by the conventional spectrophotometric method.  相似文献   
102.
本工作以金属有机框架材料UiO-67为载体,通过原位水解负载TiO_2,经焙烧后得到系列ZrxTi/C光催化剂。我们以四环素为典型抗生素在300 W氙灯光源下进行光降解研究,Zr_(0.3)Ti/C复合催化剂表现出优异的光催化效率,对于10 mg×L~(-1)四环素溶液,30 min可以降解98%。光降解速率常数分别是TiO_2、纯Ui O-67焙烧产物Zr-O-C的16倍和3.7倍。这得益于Zr_(0.3)Ti/C较大的比表面积,对四环素具有优异的吸附性能;同时具有能级匹配的Zr-O-C/TiO_2异质结构和高导电性碳材料共掺,有效提高了电子-空穴对的分离与迁移;机理研究表明光照下产生的超氧自由基(O_2·-)、羟基自由基(·OH)以及少量的空穴(h~+),共同促进了光催化降解四环素。本研究基于吸附和光催化协同作用原理,所提出的高比表面积、双金属活性的复合光催化材料的制备方法,对抗生素等环境污染物光降解治理方面有一定的指导作用。  相似文献   
103.
A simple, selective, and sensitive turn-off fluorescent assay for detecting of tetracycline in pharmaceutical dosage form based on inner filter effect (IFE) sensing platform has been described. In this IFE sensing strategy, N-doped carbon dots (CDs) were prepared by one-pot solvothermal synthesis using milk as a precursor and were directly used as a fluorophore in IFE. The prepared CDs were characterized by common spectroscopic and microscopic techniques. The CDs exhibited excitation-wavelength dependent emission with 10% as the fluorescence quantum yield. The fluorescence of CDs was decreased in correlation to the addition of absorber (tetracycline), as the excitation spectrum of the fluorophore (CDs) matches the absorption spectrum of the absorber. The present IFE-based sensing platform showed a good linear relationship from 2.0 µM to 200 µM (R2 = 0.9960) and provided a detection limit of 0.6 µM (signal-to-noise ratio of 3). Additionally, the cytotoxic effects of CDs were determined using normal healthy male Balb/C mice model treated with various doses of CDs and at the end of the study, no mortality or even no sign of toxicity was observed at oral doses of 100 and 200 mg/kg CDs in all treated animals. The proposed nanoprobe assay is a free from interferences, low-cost, biocompatible, and accurate for the detection of tetracycline in pharmaceutical formulation.  相似文献   
104.
An ultra-high-performance liquid chromatography tandem mass spectrometry method to detect residues of tetracycline (TC), epi-tetracycline (eTC) and oxytetracycline (OTC) in animal hair was developed. Hair samples were washed with water, extracted with NH4OH 0.1 M, purified by SPE-C18 cartridge and analyzed by tandem mass spectrometry (ESI+, MRM mode) with satisfactory results. For the first time, accumulation of TC, eTC and OTC was confirmed in livestock hairs after a therapeutic treatment with TC and OTC, respectively. Administered drug residues were detectable in hair samples up to 2 months after the last treatment, providing a retrospective evidence of TC and OTC administration. Hair analysis seems to offer a wider window of detection than edible tissues.  相似文献   
105.
Magnetic molecularly imprinted polymers were prepared using hydrophobic Fe3O4 magnetite as the magnetically susceptible component, oxytetracycline as template molecule, methacrylic acid as functional monomer, and styrene and divinylbenzene as polymeric matrix components. The polymers were applied to the separation of tetracycline antibiotics from egg and tissue samples. The extraction and clean-up procedures were carried out in a single step by blending and stirring the sample, extraction solvent and polymers. The analytes can be transferred from the sample matrix to the polymers directly or through the extraction solvent as medium. When the extraction was complete, the polymers adsorbing the analytes were easily separated from the sample matrix by an adscititious magnet. The analytes eluted from the polymers were determined by liquid chromatography–tandem mass spectrometry. The recoveries ranging from 72.8% to 96.5% were obtained with relative standard deviations in the range of 2.9–12.3%. The limit of detection was less than 0.2 ng g−1. The feasibility of this method was validated by analysis of incurred egg and tissue samples, and the results were compared with those obtained by the classical method in which solvent extraction, centrifugation, and subsequent clean-up and concentration by solid-phase extraction were applied. The proposed method reduced the complicacy of classical method and improved the reliability of method.  相似文献   
106.
通过前处理方法和色谱分析条件的选择优化,改进了组织中四环素族药物残留的检测方法.与国标方法相比,方法不仅无腐蚀性溶剂,而且具有灵敏度高、重复性好、准确等特点.  相似文献   
107.
To construct a single tetracycline-regulatable plasmid vector based on the double tetracycline-regulatable plasmid vector system for regulating HSV-tk gene expression so as to effectively kill HeLa cells. Two tetracycline operator(TetO2) was cloned into pcDNA3.1 and a cassette was made for a cytomegalovirus-type 2 tetracycline operator(CMV-TetO2) promoter, and the obtained vector was named pcDNA3.1-CMV-TetO2. Herpes simplex virus thymidine kinase(HSV-tk) gene and tetracycline repressor(TR) gene were cloned ...  相似文献   
108.
A new coordination polymer (H2bpy)0.5?[(UO2)1.5(ipa)2(H2O)] ( 1 ) (H2ipa=isophthalic acid, bpy=4,4′‐bipyridine) was synthesized by hydrothermal condition. It was characterized by IR spectroscopy, elemental analysis, TG‐DTA analysis, and powder X‐ray diffraction. Analysis of single‐crystal X‐ray diffraction results showed that the title compound exhibited a double chain bridged by the different uranyl ions and ipa2? ligands. Through the hydrogen bond interactions and π???π stacking interactions, the double chains were assembled into the three‐dimensional supramolecular framework. Furthermore, the compound can be used as a promising bifunctional luminescence sensor for detecting and identifying Fe3+ and tetracycline hydrochloride antibiotic molecules with high selectivity and sensitivity in aqueous solutions. Moreover, the luminescent sensing mechanisms for different analytes were proposed. Moreover, the electronic properties of title compound were explored by density functional theory (DFT) calculations. The sensor system has been successfully applied for the detection of Fe3+ and tetracycline hydrochloride with high recovery percentages and low relative standard deviation in real river water samples.  相似文献   
109.
A simple, rapid, and simultaneous analysis method for oxytertracycline, tetracycline, chlortetracycline, penicillin G, ampicillin, and nafcillin in meat has been developed by using electrospray ionization tandem mass spectrometry. The sample preparation was performed by homogenizing with water followed by a centrifugal ultrafiltration, after addition of internal standards (demeclocycline, penicillin G-d5, ampicillin-d5 and nafcillin-d6). The MS/MS analysis involves the combined use of sample enrichment on the short column and a multiple reaction monitoring technique. The overall recoveries from animal (bovine and swine) muscle, kidney, and liver fortified at the levels of 0.05 and 0.1 ppm ranged from 70 to 115% with the coefficients of variation ranging from 0.7 to 14.8% (n = 5). Analysis time, including sample preparation and determination, is only 3h per eight sample and detection limits for all antibiotics are 0.002 ppm. The method is considered to be satisfactory for the rapid screening of the tetracycline and penicillin antibiotic residues in meat.  相似文献   
110.
Tetracycline was separated from its main impurities 4-epitetracycline, anhydrotetracycline, 4-epianhydrotetracycline, chlortetracycline, and demethyltetracycline by capillary electrophoresis. Systematic method development was performed in which following parameters were consecutively optimized: type and pH of the buffer, buffer concentration, type and concentration of organic modifier, voltage and temperature. Qualitative and quantitative aspects of the method are compared with liquid chromatography.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号