首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
The influence of EDTA, carboxylic acids, amino-and hydroxocarboxylic acids, monosaccharides and humic substances on the generation of arsines in hydride generation atomic absorption spectrometry (HGAAS) was investigated. EDTA (0.02 mol L−1), ascorbic acid (0.02 mol L−1) and glucose or fructose (0.2 mol L−1) are useful additives for levelling sensitivities for As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA). The presence of glycine, malonic, tartaric acids, BICIN and soil humin extracts leads to differences in analytical signal response between these arsenic species. An analytical application to the determination of the sum of As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA) as well as the sum of toxicologically relevant hydride forming arsenic fraction As(III) + As(V) + MMA + DMA in EDTA soil/sediment extracts using continuous flow HGAAS was demonstrated. The limit of detection was 0.2 mg kg−1 As. Within-day and between-day precision were in the range 3–7% and 4–10%, respectively, for arsenic contents of 0.7–25 mg kg−1, with recoveries 95–103%.   相似文献   

2.
A simple and selective method for penicillin V potassium (PVK) determination by chemiluminescence (CL) was developed. Oxidation of PVK by alkaline hydrogen peroxide produces CL, which is greatly enhanced by N, N-dimethyl formamide (DMF) and N-cetyl-N,N,N-trimethylammonium bromide (CTMAB). Optimum conditions were established using luminometry. There is a linear relationship between the chemiluminescent peak height and the amount of PVK within the range 0.5–129.5 mg L−1, with a detection limit of 0.2 mg L−1. The coefficient of variation was 1.2% for 40 mg L−1 PVK solution (n = 7). The method is very simple, has high sensitivity and good selectivity, and is usable for process control. It was successfully utilized for the determination of PVK in pharmaceuticals and spiked human urine.   相似文献   

3.
A hollow fibre liquid phase microextraction for gas chromatographic determination of some p-hydroxybenzoic acid esters has been developed. Chlorobenzene containing tetradecane as internal standard was used for the extraction. Optimized extraction was carried out at room temperature for 40 min in the presence of 0.4 g mL−1 NaCl in the sample solution. Calibration was linear up to 30 mg L−1. Correlation coefficients were 0.996–0.998. Enrichment factors were 21, 95 and 154, and detection limits were 0.20, 0.03 and 0.01 μg mL−1 for methylparaben, ethylparaben and propylparaben, respectively. Reproducibility was acceptable with relative standard deviations up to 11.7%. The technique was tested for water and urine analysis.   相似文献   

4.
A simple and sensitive dispersive liquid-liquid microextraction method for extraction and preconcentration of pentachlorophenol (PCP) in water samples is presented. After adjusting the sample pH to 3, extraction was performed in the presence of 1% W/V sodium chloride by injecting 1 mL acetone as disperser solvent containing 15 μL tetrachloroethylene as extraction solvent. The proposed DLLME method was followed by HPLC-DAD for determination of PCP. It has good linearity (0.994) with wide linear dynamic range (0.1–1000 μg L−1) and low detection limit (0.03 μg L−1), which makes it suitable for determination of PCP in water samples.   相似文献   

5.
Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were investigated for the optimal electrode: measurement range (10−4 − 10−1 mol L−1), slope of the linear range of the calibration curve (−58.3 mV decade−1), limit of detection (6.0 × 10−5 mol L−1), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 − 9.0), reproducibility of potential (1.2 mV) and selectivity coefficients in relation to selected organic and inorganic anions. The electrode was utilized for determination of naproxen in tablets by the calibration curve method and the standard addition method.   相似文献   

6.
Ibuprofen membrane electrodes based on different plasticizers: diisobutyl phthalate (DIBP), o-nitrophenyloctyl ether (o-NPOE), dioctyl sebacate (DOS) and tetraoctylammonium 2-(4-isobutylphenyl)propionate were prepared. All electrodes show: a near Nernstian slope of characteristic (58.3–60.9 mV decade−1) in the measurement range (10−4–10−1 mol L−1), limit of detection (5.0×10−5 mol L−1), really long lifetime (12 months), dependence of the electrode potential on pH (5.5–9.0), reproducibility of potential (0.6–1.2 mV) and selectivity coefficients in relation to some organic and inorganic anions. The electrodes were applied for the determination of ibuprofen in tablets by the calibration curve method and the standard addition method.   相似文献   

7.
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.   相似文献   

8.
Ionic liquids (IL) are gaining importance as green solvents. Imidazolium ionic liquid [bmim]+[Cl], an environmentally benign solvent, was found to promote the Diels-Alder reaction between anthrone and maleimides at room temperature with excellent yields. The ionic liquid played a dual role as solvent and catalyst.   相似文献   

9.
Attempts were made to plasma deposit an oriented π-conjugated polymer of pyrrole (Py) on paper surfaces in order to produce electrically conductive layers. The N/C atomic ratio of 0.13–0.24 was observed for all treatment conditions. This implies the nature of the deposition formed on the paper surface via pulsed plasma is different from that of pyrrole monomer. An increase in conductivity of all pyrrole-plasma treated papers was observed. The 50 W RF-power with 5 min plasma exposed paper sample shows 8.15 × 10−9 S·cm−1 conductivity. The conductivity measurements indicated a plasma-enhanced ring-opening reaction mechanism of pyrrole.   相似文献   

10.
The first HPLC method for the separation of three paraben preservatives (methyl-, ethyl- and propyl parabens) using a core-shell analytical column is reported in this study. The separation was completed in less than 8 min at a low flow rate of 0.4 mL min−1 and an isocratic mobile phase containing 20% acetonitrile as organic modifier. The backpressure was < 200 bar in all cases, enabling the usage of conventional HPLC equipment. The proposed analytical procedure was validated for linearity (0.5–20 μg L−1), limits of detection (15–43 μg L−1) and quantification (50–142 μg L−1), selectivity, within day (1.3–1.5%) and day-to-day (3.4–4.6%) precision and accuracy. The proposed method has been applied to the determination of the selected paraben preservatives in commercially available hygiene wipes. The mean percent recoveries were found to be in the range of 98.0–98.4%.   相似文献   

11.
This work proposes a method for determination Cu(II) concentrations, based on the formation of a copper-1-nitroso-2-naphthol complex, in the presence of micelles; formed by a triblock copolymer, made up of two blocks of polyethylene oxide (PEO), and one block of polypropylene oxide (PPO). The insoluble copper complexes, are concentrated inside the hydrophobic micelle core; formed by the PPO block. For a solution containing 0.200 mg L−1 Cu(II), the proposed method had a relative standard deviation of 2.0% (n = 3); an absolute error from 0.11 to 0.39 mg L−1; and a linear calibration range, from 0.200 to 0.800 mg L−1. Detection and quantification limits, were 43.1 mg L−1 and 144 mg L−1, respectively. We show that there is excellent agreement, between the results obtained using our novel method; and those obtained using flame atomic absorption spectrometry: In the determination of Cu(II) concentrations, in Brazilian sugar-cane spirits. The proposed method, is the first to apply macromolecular micelle systems, to the determination of copper concentrations; and improves upon the results obtained using molecular surfactants. This method is environmentally friendly (since it does not use any organic solvents for extraction), and the triblock copolymer is biodegradable and non-toxic.   相似文献   

12.
A sensitive and convenient method for the determination of trace europium ions using an oscillating chemical reaction involving Ce(IV) - KBrO3 - acetone - oxalic acid - H2SO4 was proposed. The results indicated that the changes in oscillating period (T) was linearly proportional to the negative logarithmic concentration of Eu3+ (-log C) in the range of 1.41 × 10−8 ˜ 1.41 × 10−4 mol L−1 (r = 0.9982) with a detection limit of 1.04 × 10−9 mol L−1. The recoveries were limited to the range of 99.5% to 100.8%. Under the same conditions, other rare earth ions did not interfere with the determination of Eu3+. In addition, a perturbation mechanism was also discussed briefly.   相似文献   

13.
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation. This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).   相似文献   

14.
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.   相似文献   

15.
In the present paper, an off-line preconcentration procedure for the determination of cadmium and lead by flame atomic absorption spectrometry (FAAS) is proposed. Polyurethane foam (PUF) functionalized with o-aminophenol (o-AP) followed by Pyrazolone (Pyr) packed in a minicolumn was used as a sorbent material. The metals were retained on the modified PUF, from which it could be eluted and effectively preconcentrated. The detection limits were 0.072 and 0.016 μg L−1 for Pb and Cd respectively. Enrichment factors were 250 and 319 for lead and cadmium respectively. The procedure has been applied successfully to metal determination in water samples, fish liver and reference material.   相似文献   

16.
New methods for the determination of metoclopramide, antiemetic and gastroprokinetic pharmaceutical, were developed, using differential pulse voltammetry (DPV) and flow injection analysis (FIA) with amperometric detection on a boron-doped diamond film electrode. Electrode pretreatment necessary to ensure the stable results was investigated and it was found, that while DPV requires frequent electrode cleaning, FIA with a sufficiently high flow rate can maintain a stable signal with no signs of electrode passivation. The calculated quantification limits of the DPV and FIA with amperometric detection were 0.13 μmol L−1 and 0.015 mmol L−1, respectively. The applicability of the new methods was verified by the determination of metoclopramide in a pharmaceutical preparation. FIA with amperometic detection proved to be sensitive, accurate and, due to the resistance of the electrode to the passivation, also simple to handle.   相似文献   

17.
A convenient and sensitive method for determination of sulfanilamide (SNA) was described based on the Mn(II)-catalyzed oscillating chemical reaction. Under optimum conditions, a linear relationship existed between the changes of oscillating period or amplitude and the negative of logarithm of SNA concentration in the range of 4.27 × 10−8 mol ·L−1 ∼ 7.41 × 10−6 mol ·L−1 (RSD, 0.85%) and 9.33 × 10−8 mol ·L−1 ∼ 3.02 × 10−6 mol ·L1 (RSD, 1.08%), respectively. The lower limit of detection was found to be 2.69 × 10−8 mol ·L−1 and 6.03 × 10−8 mol ·L−1, respectively.   相似文献   

18.
A rapid, simple and reliable capillary electrophoresis method for the separation and quantitation of inorganic cations with indirect UV detection at 214 nm was developed. The electrolyte was: 12 mM imidazole as background absorbance provider; 5 mM malic acid and 1.0 mM 18-crown-6 ether as complexing agents; and 20% D2O (v/v) to improve ion mobility. The pH was 4.25. The applied voltage was 22 kV at 22°C. Nine ions were completely separated and determined with correlation coefficients of 0.9979-0.9992. The relative standard deviations (RSD) were less than 0.5% for migration time and less than 5.2% for peak area (n=8). The detection limits (S/N=3) were from 0.08 mg L−1 (for Na+) to 0.51 mg L−1 (for Cu2+). To assess the reliability atomic absorption (AA) was also used to determine the same samples. Satisfactory results were obtained for real samples of jasmine tea drink and coconut milk.   相似文献   

19.
Increasing environmental pollution caused by toxic dyes is a matter of great concern due to their hazardous nature. So it is crucial to develop processes which can destroy these dyes effectively. It has been generally agreed that reactive orange 5 (KGN) can be effectively degraded in aerated phosphotungstic acid (HPA) in a homogeneous reaction system using near-UV irradiation. In this paper, photocatalytic degradation of reactive orange 5 solutions with phosphotungstic acid was investigated, especially more attention was paid to the kinetic model and the anion degradation products. The results revealed that the photocatalytic degradation reaction of KGN with HPA in a homogenous solution can be described by Langmuir-Hinshelwood equation and Langmuir-Hinshewood kinetic model described it well. The reaction manifested the first order with lower concentration(⩽30 mg L−1) with the limiting rate constant and the adsorption constant in this case being 0.8098 mg L−1 min−1 and 4.359 10−2 L mg−1, respectively. The degradation mechanism of KGN with HPA is different from that with TiO2, the anion products of the two reaction systems are the same. The difference in degradation mechanism of KGN with HPA from that with TiO2 is caused by the nature of the photocatalyst.   相似文献   

20.
A solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectromA solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The method was based on retention of platinum in a sample on silica gel modified with aminepropyl groups. The retention of platinum(IV) from the sample solution and the recovery of platinum with 1.0 mol L−1 thiourea solution were quantitative. The relative standard deviation (RSD) was calculated as 5% (n = 7) at the 10 ng L−1 level. The enrichment factor was found to be (50-fold) for 250 mL of water sample. Under optimum conditions, the method detection limit (MDL) was found to be 1 ng L−1 for platinum in water matrices. Recoveries of Pt from spike addition to atmospheric water samples were quantitative (80–95%). The present method was used for the determination of platinum in precipitation, throughfall and runoff water samples.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏