首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, a novel polysaccharide‐based chiral stationary phase, cellulose tris(4‐chloro‐3‐methylphenylcarbamate), also called Sepapak 4 has been evaluated for the chiral separation of amlodipine (AML) and its two impurities. AML is a powerful vasodilatator drug used for the treatment of hypertension. Capillary columns of 100 μm id packed with the chiral stationary phase were used for both nano‐LC and CEC experiments. The optimization of the mobile phase composed of ACN/water, (90:10, v/v) containing 15 mM ammonium borate pH 10.0 in nano‐LC allowed the chiral separation of AML and the two impurities, but not in a single run. With the purpose to obtain the separation of the three pairs of enantiomers simultaneously, CEC analyses were performed in the same conditions achieving better enantioresolution and higher separation efficiencies for each compound. To fully resolve the mixture of six enantiomers, parameters such as buffer pH and concentration sample injection have been then investigated. A mixture of ACN/water (90:10, v/v) containing 5 mM ammonium borate buffer pH 9.0 enabled the complete separation of the three couples of enantiomers in less than 30 min. The optimized CEC method was therefore validated and applied to the analysis of pharmaceutical formulation declared to contain only AML racemate.  相似文献   

2.
Three new degradation impurities of bupropion were characterized through high performance liquid chromatography coupled to photodiode array detection and to time‐of‐flight mass spectrometry. Bupropion was subjected to the ICH prescribed stress conditions. It degraded to seven impurities (I–VII) in alkaline hydrolytic conditions which were optimally resolved on an XTerra C18 column (250 × 4.6 mm, 5 µm) with a ternary mobile phase comprising ammonium formate (20 mm , pH 4.0), methanol and acetonitrile (75:10:15, v/v). The degradation impurities (III–V and VII) were characterized on the basis of mass fragmentation pattern of drug, accurate mass spectral and photodiode array data of the drug and degradation impurities. Compound V was found to be a known degradation impurity [1‐hydroxy‐1‐(3‐chlorophenyl)propan‐2‐one], whereas III, IV and VII were characterized as 2‐hydroxy‐2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorpholine, (2,4,4‐trimethyl‐1,3‐oxazolidin‐2‐yl)(3‐chlorophenyl)‐methanone and 2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorphol‐2‐ene, respectively. Compound III was a known metabolite of the drug. This additional information on the degradation impurities can help in the development of a new stability‐indicating assay method to monitor the stability of the drug product during its shelf‐life as well as in development of a drug product with increased shelf‐life. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
High‐performance counter‐current chromatography was successfully used for the isolation and purification of terpenoid compounds from the essential oil of Pimpinella anisum L. A two‐phase solvent system composed of n‐heptane/methanol/ethyl acetate/water (5:2:5:2, v/v/v/v) was suitable for the purification of linalool, terpinen‐4‐ol, α‐terpineol, p‐anisaldehyde, while n‐heptane/methanol (1:1, v/v) was used for the isolation of anethole and foeniculin. A scale‐up process from analytical to preparative was developed. Additionally, a stepwise gradient elution was applied and instead of two different runs, 40 min each, one 80 min separation was performed; although the time of separation remains the same, it was possible to repeat the efficiency even if the water‐containing mobile phase was changed to a nonaqueous system. The obtained essential oil, as well as purified compounds, was analyzed by GC. A total of 0.64 mg of linalool, 0.52 mg of terpinen‐4‐ol, 0.10 mg of α‐terpineol, 0.62 mg of p‐anisaldehyde, 15 mg of anethole, and 2.12 mg of foeniculin were obtained from 210 mg of the essential oil of P. anisum L. in a short time with purities of 99, 98, 94, 93.54, 93, and 93.6%, respectively.  相似文献   

4.
Unambiguous structural elucidation of active pharmaceutical ingredients (API) impurities is a particularly challenging necessity of pharmaceutical development, particularly if the impurities are low level (0.1% level). In many cases, this requires acquiring high‐quality NMR data on a pure sample of each impurity. High‐quality, high signal‐to‐noise (S/N) one‐ and two‐dimensional NMR data can be obtained using liquid chromatography‐solid phase extraction‐cryoflow NMR (LC‐SPE‐cryoflow NMR) with a combination of semi‐preparative column for separation and mother liquor as a source of concentrated impurities. These NMR data, in conjunction with mass spectrometry data, allowed for quick and unambiguous structural elucidations of four impurities found at low level in the crystallized API but found at appreciable levels in the mother liquor that was used as the source for these impurities. These data show that semi‐preparative columns can be used at lower than ideal flow rates to facilitate trapping of HPLC components for LC‐SPE‐cryoflow NMR analysis without compromising chromatographic resolution. Also, despite the complex chromatography encountered with the use of mother liquor as a source of impurities, acceptably pure analytes were obtained for acquiring NMR data for unambiguous structure elucidations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A chiral liquid chromatographic method was developed and validated for the quantification of R‐enantiomer impurity (RE) in WCK 3023 (S‐enantiomer), a new drug substance. The separation was achieved on Chiralpak IA (amylose‐based immobilized chiral stationary phase), using a mobile phase consisting of n‐hexane–ethanol–trifluoroacetic acid (70:30:0.2, v/v/v) at a flow rate of 1.0 mL/min. The method was extensively validated for the quantification of RE in WCK 3023 and proved to be robust. For RE the detector response was linear over the concentration range of 0.11–5 μg/mL. The limit of quantitation and limit of detection for RE were 0.11 and 0.04 μg/mL respectively. Average recovery of the RE was in the range of 98.11–99.55%. The developed method was specific, sensitive, precise and accurate for quantitative determination of RE in WCK 3023. The impact of thermodynamic parameters on the chiral separation was evaluated. The method was employed for controlling the enantiomeric impurity in the lots of WCK 3023 used for pre‐clinical studies. The method was successfully applied to evaluate the possible conversion of WCK 3023 to RE in rat serum samples during pre‐clinical pharmacokinetic studies.  相似文献   

6.
A new hydrophilic interaction ultra‐performance LC method was established for the whole blood measurement of L‐ergothioneine. Chromatographic separation was achieved in a fairly short time, less than 4 min, on a 100 × 2.1 mm Acquity UPLC BEH HILIC 1.7 μm column with a mobile phase consisting of a mixture of 100 mmol/L ammonium acetate/ACN/water (5:85:10, v/v/v) that flowed isocratically at 0.250 mL/min. The LOD and the limit of quantification were 3.85 and 11.67 μmol/L, respectively. The method exhibited linearity in a concentration range of 15.63–1000 μmol/L (R2 > 0.999). Mean recovery was 96.34% whereas intraassay and interassay precision were 1.52 and 1.82% RSD, respectively. On the whole, the developed method is simple, fast, precise, accurate, and sensitive and may be useful for routine analyses.  相似文献   

7.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response.  相似文献   

8.
This work deals with the potentiality of nano liquid chromatography (Nano‐LC) for the chiral separation of racemic mixture of tryptophan and some selected derivatives by using 100 µm i.d. fused silica capillary packed with teicoplanin bonded to 5 µm diol silica stationary phase. The experiments were carried out by using a cheap and laboratory‐assembled nano‐LC–UV system. Elution was done in an isocratic mode using a polar organic mobile phase. In order to find the optimum chiral separation of the studied enantiomers, some chromatographic experimental parameters were systematically studied and optimized. Among them, mobile phase composition, namely organic modifier type and concentration, buffer type and pH and aqueous content and sample solvent dilution on retention time, retention factor and enantioresolution factor were studied. Baseline enantioresolution and good peak shape was achieved utilizing the mobile phase containing 40 mM ammonium formate at pH pH 2.5 in ACN/water/acetone (60:30:10, v/v/v) at 520 nL/min in less than 8 min analysis time.  相似文献   

9.
A rapid method combining microwave‐assisted extraction (MAE) and high‐speed counter‐current chromatography (HSCCC) was applied for preparative separation of six bioactive compounds including loganic acid ( I ), isoorientin‐4′‐O‐glucoside ( II ), 6′‐O‐β‐d ‐glucopyranosyl gentiopicroside ( III ), swertiamarin ( IV ), gentiopicroside ( V ), sweroside ( VI ) from traditional Tibetan medicine Gentiana crassicaulis Duthie ex Burk. MAE parameters were predicted by central composite design response surface methodology. That is, 5.0 g dried roots of G. crassicaulis were extracted with 50 mL 57.5% aqueous ethanol under 630 W for 3.39 min. The extract (gentian total glycosides) was separated by HSCCC with n‐butanol/ethyl acetate/methanol/1% acetic acid water (7.5:0.5:0.5:3.5, v/v/v/v) using upper phase mobile in tail‐to‐head elution mode. 16.3, 8.8, 12., 25.1, 40.7, and 21.8 mg of compounds I–VI were obtained with high purities in one run from 500 mg of original sample. The purities and identities of separated components were confirmed using HPLC with photo diode array detection and quadrupole TOF‐MS and NMR spectroscopy. The study reveals that response surface methodology is convenient and highly predictive for optimizing extraction process, MAE coupled with HSCCC could be an expeditious method for extraction and separation of phytochemicals from ethnomedicine.  相似文献   

10.
A method of microwave‐assisted extraction coupled with countercurrent chromatography using evaporative light scattering detection was successfully developed for the separation and purification of steroidal saponins from Paris polyphylla. The main extraction conditions including microwave power, liquid/solid ratio, irradiation time, and extraction temperature were optimized using an orthogonal array design method. A suitable two‐phase solvent system consisting of n‐heptane/n‐butanol/acetonitrile/water (10:19:6:20, v/v/v/v) was employed in the separation and purification of the extracts of P. polyphylla. A total of 7.1 mg polyphyllin VII, 4.3 mg gracillin, 9.2 mg dioscin, and 10.2 mg polyphyllin I were obtained from 1.5 g P. polyphylla in less than 300 min, the purities of which determined by HPLC were 96.7, 97.3, 98.7, and 98.6%, respectively. The identification and characterization of these compounds were performed by LC–ESI‐MS and 1H NMR spectroscopy. The results demonstrated that the proposed method is feasible, economical and efficient for the extraction, separation and purification of effective compounds from natural products.  相似文献   

11.
For the first time, rare major and minor compounds from fruits of Peucedanum cervaria were isolated. High‐performance countercurrent chromatography with two different solvent systems, heptane/ethyl acetate/methanol/water (3:2:3:2 and 2:1:2:1, v/v), was successfully used in the reversed‐phase mode. A scale‐up process from analytical to semipreparative in a very short time was developed. The structures of isolated compounds were evaluated by high‐performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry, gas chromatography with mass spectrometry, and one‐ and two‐dimensional NMR spectroscopy. (8S,9R)‐9‐(3‐Methylbutenoyloxy)‐O‐acetyl‐8,9‐dihydrooroselol (compound B), (8S,9R)‐9‐(2‐methyl‐Z‐butenoyloxy)‐O‐acetyl‐8,9‐dihydrooroselol (edultin, compound C), and (8S,9R)‐9‐acetoxy‐O‐(2α‐methylbutyryl)‐8,9‐dihydrooroselol (compound D) were obtained using heptane/ethyl acetate/methanol/water (2:1:2:1, v/v) in <40 min. The method yielded 4.6 mg of a mixture of compounds B and C (11:89) and 3.7 mg of compound D. These amounts were obtained from the crude extract (0.5 g) in a single run. Although the compounds are known, their isolation by countercurrent chromatography and the analysis of their relative stereochemistry by two‐dimensional NMR spectroscopy have been performed for the first time. Additionally, heptane/ethyl acetate/methanol/water (3:2:3:2, v/v) led to the isolation of oxypeucedanin (1.2 mg; compound A). This is the first time that angular dihydrofuranocoumarin was isolated from plant extract by countercurrent chromatography.  相似文献   

12.
In this paper, an effective method combing fast elution‐extrusion counter‐current chromatography (CCC) and LC/MS for rapid screening of antioxidative phenolic compounds in Chinese Rhubarb is presented. An integrated three‐coil CCC column (40 mL each coil) was used to accomplish the optimization of biphasic liquid system. In a single run (approximately 40 min), the solvent system composed of n‐hexane/ethyl acetate/methanol/water (1:1:1:1, v/v) was selected as optimum CCC liquid system for fast fractionation of the crude ethanol extract. With a 140 mL‐capacity CCC instrument, 100 mg Chinese Rhubarb extract was separated under the optimized conditions, producing six fractions in only 100 min. The quantities of each fraction were ~15 mg. In addition, each fraction was subjected to antioxidant activity assay and characterized by LC/MS analysis. Fifty compounds, including phenolic acids, phenolic glucosides and hydroxyanthraquinones, were detected by LC/MS/MS analysis. As a result, gallic acid together with Fr I showed excellent antioxidant activity, which was well consistent with previous studies and exhibited great potential for natural drug discovery program of the present method.  相似文献   

13.
Ramosetron is an enantiopure active pharmaceutical ingredient marketed in Japan since 1996 and later in a few Southeast Asian countries predominantly as an antiemetic for patients receiving chemotherapy. In this study, a simple and rapid high‐performance liquid chromoatography method for the separation of ramosetron and its related enantiomeric impurity by using hydrophilic interaction liquid chromatography mode is presented. Chiral resolution was performed on an analytical column (100 mm × 4.6 mm id) packed with 3 μm particles of cellulose‐based Chiralpak IC‐3 chiral stationary phase. Using a mobile phase containing acetonitrile–water–diethylamine (100:10:0.1, v/v/v) and setting the column temperature at 35°C, the resolution value was 7.35. At a flow rate of 1 mL/min, the enantioseparation was completed within 5 min. The proposed method was partially validated and it has proven to be sensitive with limit of detection and limit of quantitation of the (S)‐enantiomer impurity of 44.5 and 133.6 ng/mL.  相似文献   

14.
A simple, rapid, selective, accurate and precise method is described for the determination of risperidone and its active metabolite, 9‐hydroxyrisperidone, in plasma using a chemical derivative of risperidone (methyl‐risperidone) as the internal standard. The sample workup involved a single‐step extraction of 1 mL plasma, buffered to pH 10, with heptane–isoamyl alcohol (98:2 v/v), then evaporation of the heptane phase and reconstitution of the residue in mobile phase. HPLC separation was carried out at on C18 column using a mobile phase of 0.05 m dipotassium hydrogen orthophosphate (containing 0.3% v/v triethylamine) adjusted to pH 3.7 with orthophosphoric acid (700 mL), and acetonitrile (300 mL). Flow rate was 0.6 mL/min and the detection wavelength was 280 nm. Retention times were 2.6, 3.7 and 5.8 min for 9‐hydroxy risperidone, risperidone and the internal standard, respectively. Linearity in spiked plasma was demonstrated from 2 to 100 ng/mL for both risperidone and 9‐hydroxyrisperidone (r ≥ 0.999). Total imprecision was less than 13% (determined as co‐efficient of variation) and the inaccuracy was less than 12% at spiked concentrations of 5 and 80 ng/mL. The limit of detection, determined as three times the baseline noise, was 1.5 ng/mL. Clinical application of the assay was demonstrated for analysis of post‐dose (0.55–4.0 mg/day) samples from 28 paediatric patients (aged 6.9–17.9 years) who were taking risperidone orally for behavioural and emotional disorders. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
A very accurate and selective LC‐MS/MS method was developed and validated for the quantification of 2′‐C‐modified nucleoside triphosphate in liver tissue samples. An efficient pretreatment procedure of liver tissue samples was developed, using a fully automated SPE procedure with 96‐well SPE plate (weak anion exchange sorbent, 30 mg). Nucleotide hydrophilic interaction chromatography has been performed on an aminopropyl column (100 mm×2.0 mm, 3 μm) using a gradient mixture of ACN and ACN/water (5:95 v/v) with 20 mM ammonium acetate at pH 9.45 as mobile phase at 300 μL/min flow rate. The 2′‐C‐modified nucleoside triphosphate was detected in the negative ESI mode in multiple reaction monitoring (MRM) mode. Calibration curve was linear over the 0.05–50 μM concentration range. Satisfying results, confirming the high reliability of the established LC‐MS/MS method, were obtained for intraday precision (CV = 2.5–9.1%) and accuracy (92.6–94.8%) and interday precision (CV = 9.6–11.5%) and accuracy (94.4–102.4%) as well as for recovery (82.0–112.6%) and selectivity. The method has been successfully applied for pharmacokinetic studies of 2′‐C‐methyl‐cytidine‐triphosphate in liver tissue samples.  相似文献   

16.
A simple reversed‐phase high‐performance liquid chromatography method for the chiral separation of the active pharmaceutical ingredient (S)‐clopidogrel has been developed on the cellulose‐based Chiralcel OJ‐RH chiral stationary phase. The S enantiomer was baseline resolved from its R impurity (impurity C) with a mobile phase consisting of methanol/water (100:15) without any interference coming from the other two potential chiral impurities A and B. The enantio‐ and chemoselective method was partially validated and compared with that reported in the United States Pharmacopoeia for the drug product. The versatility of the Chiralcel OJ‐RH allowed separating the enantiomers of the impurity B also under normal phase and setting up an efficient strategy to convert the racemic sample into the enantiomeric S form on a semipreparative scale.  相似文献   

17.
Lanosterol is a potential drug for cataracts treatment, which can reverse the aggregation of intracrystalline proteins. The low concentration in lanolin calls for high‐performance separation methods. In this study, a counter‐current chromatography dual‐mode elution method was developed for the first time to separate and purify lanosterol from hexane extract of lanolin after saponification, in which the column was first eluted with the lower phase as mobile phase in head‐to‐tail mode, followed by the upper phase in the tail‐to‐head mode. High purity of lanosterol, dihydrolanosterol, and cholesterol can be obtained simultaneously. A solvent system composed of n‐heptane/acetonitrile/ethyl acetate (5:5:1, v/v/v) was selected and optimized via partition coefficient determination. Compounds such as 111 mg lanosterol, 84 mg dihydrolanosterol, and 183 mg cholesterol with high purity of 99.77, 95.71, and 91.43%, respectively, analyzed by high‐performance liquid chromatography were obtained within 80 min from 700 mg crude extract from 1.78 g lanolin. The method was also used to improve the purity of commercial lanosterol product from 66.97 to above 99%. Counter‐current chromatography could serve as a potential and powerful technique for commercial production of highly pure lanosterol.  相似文献   

18.
Tadalafil is used for the treatment of erectile dysfunction. Its related patents expired in 2016, and so related generic drug production is predicted to be increased. This work is focused on developing a fast ultra‐high‐performance liquid chromatography with diode array detection and/or mass spectrometry detection for the separation and determination of tadalafil and its impurities in pharmaceutical samples. A modern reversed‐phase stationary phase with sub‐2 μm particle size, Zorbax StableBond Rapid Resolution High Definition with octylsilane chemically bonded phase to totally porous silica particles, was used for the solving this problem. Column temperature was set at 40 ± 0.1°C. A mobile phase consisting of acetonitrile and aqueous solution of 0.1% (v /v) trifluoroacetic acid for diode array detection detection and 0.05% (v /v) formic acid, both running at a flow rate of 0.62 mL/min, were used to achieve the required separation of all components within a 5 min run. The limit of detection was 3.5 μg/L and the limit of quantification was 10.0 μg/L for the method for both UV and MS detectors. Accurate mass spectra of tadalafil's related impurities are shown for advanced confirmation. The method is directly transferable to routine analysis of tadalafil in pharmaceutical and control laboratories.  相似文献   

19.
A simple, rapid and sensitive liquid chromatography/positive ion electro‐spray tandem mass spectrometry method (LC‐MS/MS) was developed and validated for the quantification of fexofenadine with 100 μL human plasma employing glipizide as internal standard (IS). Protein precipitation was used in the sample preparation procedure. Chromatographic separation was achieved on a reversed‐phase C18 column (5 μm, 100 × 2.1 mm) with methanol : buffer (containing 10 mmol/L ammonium acetate and 0.1% formic acid; 70 : 30, v/v) as mobile phase. The total chromatographic runtime was approximately 3.0 min with retention time for fexofenadine and IS at approximately 1.9 and 2.1 min, respectively. Detection of fexofenadine and IS was achieved by LC‐MS/MS in positive ion mode using 502.1 → 466.2 and 446.0 → 321.1 transitions, respectively. The method was proved to be accurate and precise at linearity range of 1–600 ng/mL with a correlation coefficient (r) of ≥0.9976. The validated method was applied to a pharmacokinetic study in human volunteers following oral administration of 60 or 120 mg fexofenadine formulations, successfully. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号