首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 797 毫秒
1.
Fan Wang  Hongxia Zeng  Jian Wang 《Chromatographia》2013,76(23-24):1683-1695
Nineteen impurities in roxithromycin drug substance made in China were separated and identified by HPLC–MSn (TOF and TRAP) for the further improvement of official monographs in Pharmacopoeias. The fragmentation patterns and structural assignment of these impurities were studied. The column was Shim VP-ODS (250 × 4.6 mm, 5 μm). The mobile phase was 10 m mol L?1 ammonium acetate and 0.1 % formic acid aqueous solution-acetonitrile (62.5:37.5). In positive mode, full scan LC–MS was first performed to obtain the m/z value of the protonated molecules and formulas of all detected peaks on Agilent 6538Q TOF high resolution mass spectrometer. LC–MS-MS and LC–MS-MS–MS were then carried out on the compounds of interest on AB SCIEX 4000 Q TRAP? composite triple quadrupole/linear ion trap tandem mass spectrometer. The complete fragmentation patterns of nineteen impurities were studied and used to obtain information about the structures of these impurities. The structures of nineteen impurities in roxithromycin drug substance were deduced based on the HPLC–MSn data, in which nine impurities were novel impurities.  相似文献   

2.
Wang  Fan  Zeng  Hongxia  Wang  Jian 《Chromatographia》2013,76(23):1683-1695

Nineteen impurities in roxithromycin drug substance made in China were separated and identified by HPLC–MSn (TOF and TRAP) for the further improvement of official monographs in Pharmacopoeias. The fragmentation patterns and structural assignment of these impurities were studied. The column was Shim VP-ODS (250 × 4.6 mm, 5 μm). The mobile phase was 10 m mol L−1 ammonium acetate and 0.1 % formic acid aqueous solution-acetonitrile (62.5:37.5). In positive mode, full scan LC–MS was first performed to obtain the m/z value of the protonated molecules and formulas of all detected peaks on Agilent 6538Q TOF high resolution mass spectrometer. LC–MS-MS and LC–MS-MS–MS were then carried out on the compounds of interest on AB SCIEX 4000 Q TRAP™ composite triple quadrupole/linear ion trap tandem mass spectrometer. The complete fragmentation patterns of nineteen impurities were studied and used to obtain information about the structures of these impurities. The structures of nineteen impurities in roxithromycin drug substance were deduced based on the HPLC–MSn data, in which nine impurities were novel impurities.

  相似文献   

3.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

4.
Analysis of pesticide residues in water and food matrices is an active research area closely related to food safety and environmental issues. In this aspect mass spectrometry (MS) coupled to gas chromatography (GC) and liquid chromatography (LC) has been increasingly used in the analysis of pesticide residues in water and food. The increasing interest in application of high‐resolution mass spectrometry with time‐of‐flight (TOF) and hybrid triple quadrupole TOF in pesticide analysis is due to its capability of performing both targeted and nontargeted analysis. This article discusses an overview of the application of GC‐TOF‐MS and LC‐TOF‐MS in water and food matrices.  相似文献   

5.
Following the underlying principles of quality by design mentioned in the ICH Q8 guidance, systematic approaches for the control of process‐related impurities have been taken in the manufacturing process of fasudil hydrochloride, a potent Rho‐kinase inhibitor and vasodilator. Three related impurities were found in fasudil hydrochloride lab samples by a newly developed RP‐HPLC with volatile mobile phase gradient elution and UV detection method. The elemental compositions of the impurities were determined by positive ESI high‐resolution TOF‐MS analysis of their [M + H]+ ions and their structures were identified through the elucidation of the product mass spectra obtained by a triple quadrupole mass spectrometer. The key impurity was further verified through synthesis and organic spectroscopy including NMR and IR spectroscopy. The origins of these impurities were located and the effective approaches to eliminate them were proposed based on the redesign of the synthetic conditions. The results obtained are important for quality control in the manufacture of fasudil hydrochloride bulk drug substance and injection.  相似文献   

6.
Capillary electrophoresis with on-line electrospray ionisation mass spectrometry (CE/ESI-MS) has been used to identify process impurities in a batch of the anti-atherosclerotic drug, SB-253149. The impurities were separated from the main drug compound by capillary electrophoresis (CE) using an ammonium formate buffer at low pH in an untreated fused silica capillary. The CE method was initially developed using UV as the detection mode and then later structural elucidation work was achieved using an ion trap mass spectrometer. To maintain peak resolution and peak shape when the CE system was coupled to the mass spectrometer, a modified capillary cassette linked to a coaxial sheath flow electrospray ionisation (ESI) interface was used. By performing MS/MS experiments in conjunction with chemical knowledge of the reactivities of SB-253149, it was possible to propose molecular structures for impurities detected in the batch of SB-253149. The results from this study revealed that most of the process impurities in SB-253149 were dimeric derivatives of the parent molecule as well as trace levels of the starting material. This type of information was vital in process control and optimisation for the synthetic route for this drug.  相似文献   

7.
Pressure‐sensitive adhesives (PSA) are used to manufacture labels that are applied directly on the food. These adhesives could contain not only intentionally added compounds (IAS) to the adhesive formula but also non‐intentionally added substances (NIAS), due to the impurities from the raw materials used, decomposition of the initial components or from chemical interactions between them. These compounds could migrate to the food and contaminate it. In this study, gas chromatography coupled with mass spectrometry (GC‐MS/Q) and atmospheric pressure gas chromatography coupled to a quadrupole hyphenated to a time of flight mass spectrometer (APGC‐MS/Q‐TOF) have been used for identification of unknown compounds and NIAS coming from a PSA. Seven compounds were identified by GC‐MS/Q, and other eight compounds remained initially unknown. The structure of these eight new compounds was elucidated by working with the spectra obtained by APGC‐MS/Q‐TOF. Finally, two different migration studies were carried out. The first one with Tenax as solid food simulant in contact with the paper label containing the adhesive and the second one with isooctane filled in a natural pork intestine where the label containing the adhesive was applied on the external side. The results are shown and discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time‐of‐flight MS coupled with LC (LC‐IT‐TOF‐MS) has successfully integrated ease of operation, compatibility with LC flow rates and data‐dependent MSn with high mass accuracy and mass resolving power. The MSn and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC‐IT‐TOF‐MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT‐TOF instrument. Then, a general workflow for metabolite profiling using LC‐IT‐TOF‐MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC‐IT‐TOF‐MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   

10.
The mass resolution of a time-of-flight (TOF) mass spectrometer is directly proportional to its total flight pathlength. Multi-turn or multi-passage ion optical geometries are necessary to obtain fight distances of sufficient length within reasonable size limitations. We have investigated ion optics for a multi-turn TOF mass spectrometer with electrostatic sectors. The concept of 'perfect' focusing conditions is introduced. Furthermore, a new type of multi-turn TOF mass spectrometer, the MULTUM Linear plus, was developed. It consists of four cylindrical electric sectors and 28 electric quadrupole lenses. It has a vacuum chamber 60 x 70 x 20 cm in size. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of 350 000 (m/z = 28, FWHM) was achieved after 501.5 cycles. The MULTUM Linear plus analyzer is not simple, however; 28 electric quadrupole lenses are used. In order to reduce the number of ion optical parts, an improved multi-turn TOF mass spectrometer, the MULTUM II, consisting of only four toroidal electric sectors, was also developed. The possibility of tandem mass spectrometric applications using multi-turn TOF mass spectrometers is also discussed.  相似文献   

11.
The field of drug metabolism has been revolutionized by liquid chromatography/mass spectrometry (LC/MS) applications with new technologies such as triple quadrupoles, ion traps and time-of-flight (ToF) instrumentation. Over the years, these developments have often relied on the improvements to the mass spectrometer hardware and software, which has allowed users to benefit from lower levels of detection and ease-of-use. One area in which the development pace has been slower is in high-performance liquid chromatography (HPLC). In the case of metabolite identification, where there are many challenges due to the complex nature of the biological matrices and the diversity of the metabolites produced, there is a need to obtain the most accurate data possible. Reactive or toxic metabolites need to be detected and identified as early as possible in the drug discovery process, in order to reduce the very costly attrition of compounds in late-phase development. High-resolution, exact mass measurement plays a very important role in metabolite identification because it allows the elimination of false positives and the determination of non-trivial metabolites in a much faster throughput environment than any other standard current methodology available to this field. By improving the chromatographic resolution, increased peak capacity can be achieved with a reduction in the number of co-eluting species leading to superior separations. The overall enhancement in the chromatographic resolution and peak capacity is transferred into a net reduction in ion suppression leading to an improvement in the MS sensitivity. To investigate this, a number of in vitro samples were analyzed using an ultra-performance liquid chromatography (UPLC) system, with columns packed with porous 1.7 mum particles, coupled to a hybrid quadrupole time-of-flight (ToF) mass spectrometer. This technique showed very clear examples for fundamental gains in sensitivity, chromatographic resolution and speed of analysis, which are all important factors for the demands of today's HTS in discovery.  相似文献   

12.
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available.  相似文献   

13.
Amino acids in biological fluids have previously been shown to be detectable using liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with perfluorinated acids as ion-pairing agents. To date, these studies have used precursor mass, retention time and tandem mass spectrometry (MS/MS) to identify and quantify amino acids. While this is a potentially powerful technique, we sought to adapt the method to time-of-flight (TOF)MS. A new application of a recently described liquid chromatographic separation method was coupled with TOFMS to employ accurate mass for qualitative identification; resulting in additional qualitative data not available with standard single quadrupole data. In the current study, we evaluated 25 physiological amino acids and one dipeptide that are routinely quantified in human plasma. Accuracy and precision of the method was evaluated by spiking human plasma with a mix of the 25 amino acids; in addition, the inclusion of a cation-exchange cleanup step was evaluated. The calibration curves were linear over a range from 1.56 to 400 microM. The dynamic range was found to be within physiological levels for all amino acids analyzed. Accuracy and precision for most of the amino acids was between 80-120% spike recovery and <10% relative standard deviation (RSD). The LC/MS technique described in this study relies on mass accuracy and is suitable for the quantitation of free amino acids in plasma.  相似文献   

14.
In the past, the preferred strategy for the identification of unknown compounds was to search in an appropriate mass spectral database for spectra obtained using either electron ionisation (GC‐MS analyses) or collision‐induced dissociation (LC‐MS/MS analyses). Recently, an increase has been seen in the use of accurate mass instruments and spectra‐less databases, based on monoisotopic accurate mass alone. In this article, we describe a systematic workflow for the screening and identification of new flame retardants. This approach utilises LC‐quadrupole‐time‐of‐flight MS and spectra‐less databases based only on monoisotopic accurate mass for the identification of ‘unknowns’. An in‐house database was built, and the input parameters used in the data analysis process were optimised for flame retardant chemicals, so that it can be easily transferred to other laboratories. The procedure was successfully applied to dust, foam and textiles from car interiors and indoor consumer products. The developed method was demonstrated for the main new flame retardant present in Antiblaze V6 and for the three unreported reaction by‐products/impurities present in the same technical mixture. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Tetracosactide is a synthetic peptide analogue of the human adrenocorticotropic hormone that stimulates the production of cortisol in the adrenal cortex. The medical use of the compound is primarily the diagnosis of the adrenal cortex function. In order to characterize impurities of the drug, tetracosactide samples were analysed by both liquid chromatography and capillary electrophoresis coupled to a quadrupole time-of-flight mass spectrometer. The identification of the impurities was carried out based on accurate mass determination and fragment ion spectra. The presence of several peptides of lower and higher masses than tetracosactide could be shown, including N- and C-terminally truncated peptides as well as peptides which still contained protecting groups or additional amino acids. Furthermore, a semi-quantitative estimation of the relative amounts of the impurities in different samples as well as a commercial preparation revealed that the number and the type of the impurities varied between the samples. Comparing the selectivity of liquid chromatography and capillary electrophoresis regarding the separation of tetracosactide impurities, it can be stated that capillary electrophoresis showed a higher suitability for the separation of tetracosactide fragments (smaller peptides) while the larger peptides, i.e. those wearing protecting groups, were separated more efficiently by liquid chromatography.  相似文献   

16.
马晓萌  靳兰  李雅宁  郑珲  魏芸 《色谱》2018,36(3):268-277
建立了高效液相色谱-离子阱/飞行时间质谱(HPLC-IT/TOF MS)分析违禁药品邻氯苯基环戊酮样品中杂质成分的方法。对邻氯苯基环戊酮标准品进行多级质谱分析,根据各碎片离子的精确质量数推测邻氯苯基环戊酮的裂解路径,并利用该方法检测出邻氯苯基环戊酮样品中的2种杂质成分:2-氯苯甲酸酸酐和1,2-二邻氯苯甲酰基环戊烯,推断出该违禁药品的合成方法,为追溯其来源提供了重要依据。同时建立了制备邻氯苯基环戊酮标准品的方法,制备高效液相色谱条件是流动相甲醇-水(85∶15,v/v),流速8 mL/min,进样量1 mL。制备得到的邻氯苯基环戊酮标准物质纯度为99.53%。该方法简单、高效,可拓展应用于其他违禁药物标准物质的制备。  相似文献   

17.
Zheng Y  Li H  Guo Z  Lin JM  Cai Z 《Electrophoresis》2007,28(9):1305-1311
A novel approach using sheath flow chip-based CE coupled to a quadrupole TOF mass spectrometer was developed and applied to the analysis of an O-glycopeptide. The method provided good separation and sensitive analysis of the glycopeptide and its beta-elimination product. The beta-elimination reaction of the glycopeptide with ammonia or dimethylamine was adapted for changing the glycopeptide into deglycosylated form and for specifying the site of glycosylation. MS/MS analysis of the native peptide, glycopeptide and beta-elimination product enabled the identification of the glycosylation site through the comparison of the fragmentations and peptide sequence analysis.  相似文献   

18.
The objective of this study was to develop an effective strategy for screening and identifying mycotoxins in herbal medicine (HM). Here, Imperatae Rhizoma, a commonly used Chinese herb, was selected as a model HM. A crude drug contaminated with fungi was analyzed by comparing with uncontaminated ones. Ultra‐performance LC coupled to tandem quadrupole TOF‐MS (UPLC–Q‐TOF‐MS) with collision energy function was applied to analyze different samples from Imperatae Rhizoma. Then, MarkerLynxTM software was employed to screen the excess components in analytes, compared with control samples, and those selected markers were likely to be the metabolites of fungi. Furthermore, each of the accurate masses of the markers obtained from MarkerLynxTM was then searched in a mycotoxins/fungal metabolites database established in advance. The molecular formulas with relative mass error between the measured and theoretical mass within 5 ppm were chosen and then applied to MassFragmentTM analysis for further confirmation of their structures. With the use of this approach, five mycotoxins that have never been reported in HM were identified in contaminated Imperatae Rhizoma. The results demonstrate the potential of UPLC–Q‐TOF‐MS coupled with the MarkerLynxTM software and MassFragmentTM tool as an efficient and convenient method to screen and identify mycotoxins in herbal materials and aid in the quality control of HM.  相似文献   

19.
The use of gas chromatography coupled to high‐resolution magnetic sector mass spectrometers (GC‐HRMS) is well established for dioxin and furan analysis. However, the use of gas chromatography coupled to triple quadrupole (MS/MS) and time of flight (TOF) mass spectrometers with atmospheric pressure ionization (API) and traditional electron ionization (EI) for dioxin and furan analysis is emerging as a viable alternative to GC‐HRMS screening. These instruments offer greater versatility in the lab for a wider range of compound identification and quantification as well as improved ease of operation. The instruments utilized in this study included 2 API‐MS/MS, 1 traditional EI‐MS/MS, an API‐quadrupole time of flight mass spectrometer (API‐QTOF), and a EI‐high‐resolution TOF (EI‐HRTOF). This study compared these 5 instruments to a GC‐HRMS using method detection limit (MDLs) samples for dioxin and furan analysis. Each instrument demonstrated acceptable MDL values for the 17 chlorinated dioxin and furans studied. The API‐MS/MS instruments provide the greatest overall improvement in MDL value over the GC‐HRMS with a 1.5 to 2‐fold improvement. The API‐QTOF and EI‐TOF demonstrate slight increases in MDL value as compared with the GC‐HRMS with a 1.5‐fold increase. The 5 instruments studied all demonstrate acceptable MDL values with no MDL for a single congener greater than 5 times that for the GC‐HRMS. All 5 instruments offer a viable alternative to GC‐HRMS for the analysis of dioxins and furans and should be considered when developing new validated methodologies.  相似文献   

20.
Investigation of acetylspiramycin (ASPM) and its related substances was carried out using a reversed-phase liquid chromatography/tandem mass spectrometry method. The identification of impurities in the ASPM complex was performed with a quadrupole ion trap mass spectrometer, with an electrospray ionization (ESI) source in the positive ion mode which provides MSn capability. A total of 83 compounds were characterized in commercial samples, among which 31 impurities that had never been reported and 31 partially characterized impurities were deduced using the collision-induced dissociation (CID) spectra of major ASPM components as templates. Most of the major impurities arise from the starting materials and the synthesis process. This work provides very useful information for quality control of ASPM and evaluation of its synthesis process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号