首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

We have studied the direct electrochemistry of glucose oxidase (GOx) immobilized on electrochemically fabricated graphite nanosheets (GNs) and zinc oxide nanoparticles (ZnO) that were deposited on a screen printed carbon electrode (SPCE). The GNs/ZnO composite was characterized by using scanning electron microscopy and elemental analysis. The GOx immobilized on the modified electrode shows a well-defined redox couple at a formal potential of −0.4 V. The enhanced direct electrochemistry of GOx (compared to electrodes without ZnO or without GNs) indicates a fast electron transfer at this kind of electrode, with a heterogeneous electron transfer rate constant (Ks) of 3.75 s−1. The fast electron transfer is attributed to the high conductivity and large edge plane defects of GNs and good conductivity of ZnO-NPs. The modified electrode displays a linear response to glucose in concentrations from 0.3 to 4.5 mM, and the sensitivity is 30.07 μA mM−1 cm−2. The sensor exhibits a high selectivity, good repeatability and reproducibility, and long term stability.

Graphical representation for the fabrication of GNs/ZnO composite modified SPCE and the immobilization of GOx

  相似文献   

2.
An electrochemical glucose biosensor was developed by immobilizing glucose oxidase (GOx) on a glass carbon electrode that was modified with molybdenum disulfide (MoS2) nanosheets that were decorated with gold nanoparticles (AuNPs). The electrochemical performance of the modified electrode was investigated by cyclic voltammetry, and it is found that use of the AuNPs-decorated MoS2 nanocomposite accelerates the electron transfer from electrode to the immobilized enzyme. This enables the direct electrochemistry of GOx without any electron mediator. The synergistic effect the MoS2 nanosheets and the AuNPs result in excellent electrocatalytic activity. Glucose can be detected in the concentration range from 10 to 300 μM, and down to levels as low as 2.8 μM. The biosensor also displays good reproducibility and long-term stability, suggesting that it represents a promising tool for biological assays. Figure
A MoS2-based glucose sensor has been prepared by gold nanoparticles-decorated MoS2 nanocomposite, which exhibited excellent electrocatalytic activity, reproducibility and long-term stability. It was applied to determine glucose concentration in human serum, suggest the sensor maybe promising for practical application.  相似文献   

3.
A glassy carbon electrode was modified with β-manganese dioxide (β-MnO2), and glucose oxidase (GOx) was immobilized on its surface. The β-MnO2 nanowires were prepared by a hydrothermal method and characterized by scanning electron microscopy and powder X-ray diffraction. They were then dispersed in Nafion solution and cast on the glassy carbon electrode (GCE) to form an electrode modified with β-MnO2 nanowires that exhibits improved sensitivity toward hydrogen peroxide. If GOx is immobilized in the surface, the β-MnO2 acts as a mediator, and Nafion as a polymer backbone. The fabrication process was characterized by electrochemical impedance spectroscopy, and the sensor and its materials were characterized by cyclic voltammetry and amperometry. The biosensor enables amperometric detection of glucose with a sensitivity of 38.2 μA?·?mM?1?·?cm?2, and a response time of?<?5 s. This study also demonstrates the feasibility of realizing inexpensive, reliable, and high-performance biosensors using MnO2 nanowires.
Figure
The sensitive determination of glucose was realized at a β-MnO2 NWs modified glassy carbon electrode by amperometry. The relatively fast, reproducible and low-cost manufacturing procedure suggests that it can offer an excellent platform for glucose oxidase-biosensing applications.  相似文献   

4.
We report on a nonenzymatic method for the determination of glucose using an electrode covered with graphene nanosheets (GNs) modified with Pt-Pd nanocubes (PtPdNCs). The latter were prepared on GNs by using N,N-dimethylformamide as a bifunctional solvent for the reduction of both metallic precursors and graphene oxide, and for confining the growth of PtPdNCs on the surface. The modified electrode displays strong and sensitive current response to the electrooxidation of glucose, notably at pH 7. The sensitivities increase in the order of Pt1Pd5NCs< Pt1Pd3NCs< Pt5Pd1NCs< Pt3Pd1NCs< Pt1Pd1NCs. At an applied potential of +0.25 V, the electrode responds linearly (R?=?0.9987) to glucose in up to 24.5 mM concentration, with a sensitivity of 1.4 μA cm?2 M?1. The sensor is not poisoned by chloride, and not interfered by ascorbic acid, uric acid and p-acetamidophenol under normal physiological conditions. The modified electrode also displays a wide linear range, good stability and fast amperometric response, thereby indicating the potential of the bimetallic materials for nonenzymatic sensing of glucose.
Figure
nonenzymatic electrochemical method was developed for glucose determination using an electrode modified with PtPd nanocubes/graphene nanosheets (PtPdNCs/GNs). The new material shows a good performance in the sensing of glucose, thus is promising for the future development of nonenzymatic glucose sensors.  相似文献   

5.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer.
Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum.  相似文献   

6.
Mesoporous ZnO-NiO architectures were prepared by thermal annealing of zinc-nickel hydroxycarbonate composites. The resulting architectures are shown to be assembled by many mesoporous nanosheets, and this results in a large surface area and a strong synergy between the ZnO and NiO nanoparticles. The material obtained by annealing at 400 °C was used as an electrode that responds to glucose over a wide concentration range (from 0.5 μM to 6.4 mM), with a detection limit as low as 0.5 μM, fast response time (<3 s), and good sensitivity (120.5 μA?·?mM?1?·?cm?2). Figure
The mesoporous ZnO-NiO architecture by annealing at 400 °C was used as an electrode that responds to glucose over a wide concentration range (from 0.5 μM to 6.4 mM), with a detection limit as low as 0.5 μM, fast response time (<3 s), and good sensitivity (120.5 μA?·?mM?1?·?cm?2   相似文献   

7.
A reagentless third generation electrochemical glucose biosensor was fabricated based on wiring the template enzyme glucose oxidase (GOx) with graphene nanoribbons (GN) in order to create direct electron transfer between the co-factor (flavin adenine dinucleotide, FAD) and the electrode. The strategy involved: (i) isolation of the apo-enzyme by separating it from its co-enzyme; (ii) preparation of graphene nanoribbons (GN) by oxidative unzipping of multi-walled carbon nanotubes; (iii) adsorptive immobilization of GNs on the surface of a screen printed carbon electrode (SPCE); (iv) covalent attachment of FAD to the nanoribbons; (v) recombination of the apo-enzyme with the covalently bound FAD to the holoenzyme; and (vi) stabilization of the bio-layer with a thin membrane of Nafion. The biosensor (referred to as GN/FAD/apo-GOx/Nafion/SPCE) is operated at a potential of +0.475 V vs Ag/AgCl/{3 M KCl} in flow-injection mode with an oxygen-free phosphate buffer (pH 7.5) acting as a carrier. The signals are linearly proportional to the concentration of glucose in the range from 50 to 2000 mg?L?1 with a detection limit of 20 mg?L?1. The repeatability (10 measurements, at 1000 mg?L?1 glucose) is ±1.4% and the reproducibility (5 sensors, 1000 mg?L?1 glucose) is ±1.8%. The biosensor was applied to the determination of glucose in human serum.
Graphical abstract Wiring of the apo-enzyme of glucose oxidase (apo-GOx) with graphene nanoribbons (GN) bound to FAD at a screen-printed carbon electrode (SPCE). Cyclic voltammetric and amperometric responses to various glucose concentrations.
  相似文献   

8.
We have constructed a new electrochemical biosensor by immobilization of hemoglobin (Hb) and ZnWO4 nanorods in a thin film of chitosan (CTS) on the surface of carbon ionic liquid electrode. UV–vis and FT-IR spectra reveal that Hb remains in its native conformation in the film. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry. A pair of well-defined redox peaks appears which indicates direct electron transfer from the electrode. The presence of CTS also warrants biocompatibility. The electron transfer coefficient and the apparent heterogeneous electron transfer rate constant were calculated to be 0.35 and 0.757 s?1, respectively. The modified electrode displays good electrocatalytic activity for the reduction of trichloroacetic acid with the detection limit of 0.613 mmol L?1 (3σ). The results extend the protein electrochemistry based on the use of ZnWO4 nanorods.
Figure
A ZnWO4 nanorods and hemoglobin nanocomposite material modified carbon ionic liquid electrode was used as the platform for the construction of an electrochemical hemoglobin biosensor.  相似文献   

9.
We report on a novel amperometric glassy carbon biosensing electrode for glucose. It is based on the immobilization of a highly sensitive glucose oxidase (GOx) by affinity interaction on carbon nanotubes (CNTs) functionalized with iminodiacetic acid and metal chelates. The new technique for immobilization is exploiting the affinity of Co(II) ions to the histidine and cysteine moieties on the surface of GOx. The direct electrochemistry of immobilized GOx revealed that the functionalized CNTs greatly improve the direct electron transfer between GOx and the surface of the electrode to give a pair of well-defined and almost reversible redox peaks and undergoes fast heterogeneous electron transfer with a rate constant (k s) of 0.59?s?1. The GOx immobilized in this way fully retained its activity for the oxidation of glucose. The resulting biosensor is capable of detecting glucose at levels as low as 0.01?mM, and has excellent operational stability (with no decrease in the activity of enzyme over a 10?days period). The method of immobilizing GOx is easy and also provides a model technique for potential use with other redox enzymes and proteins.
Figure
This paper reports a novel amperometric biosensor for glucose based on the immobilization of the glucose oxidase (GOx) by affinity interaction on carbon nanotubes (CNTs) functionalized with iminodiacetic acid and metal chelates. The GOx immobilized in this way fully retained its activity for the oxidation of glucose. The resulting biosensor exhibited high sensitivity, good stability and selectivity.  相似文献   

10.
A highly sensitive electrochemical sensor for determination of L-cysteine (CySH) is presented. It is based on vertically aligned multiwalled carbon nanotubes modified with Pt nanoparticles by magnetron sputtering deposition. The morphology of the nanocomposite was characterized by scanning electron microscopy, transmission electron microscopy and energy-dispersive. The electrochemistry of CySH was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The mechanism for the electrochemical reaction of CySH at the modified electrode at different pH values is discussed. The electrode exhibits a higher electrocatalytic activity towards the oxidation of CySH than comparable other electrodes. It displays a linear dependence (R 2?=?0.9980) on the concentration of CySH in the range between 1 and 500 μM and at an applied potential of +0.45 V, a remarkably low detection limit of 0.5 μM (S/N?=?3), and an outstandingly high sensitivity of 1.42?×?103 μA?mM?1?cm?2, which is the highest value ever reported. The electrode also is highly inert towards other amino acids, creatinine and urea. The sensor was applied to the determination of CySH in urine with satisfactory recovery, thus demonstrating its potential for practical applications.
Figure
Pt nanoparticles on carbon nanotubes by sputtering deposition show high performance for L-cysteine sensing  相似文献   

11.
A glucose biosensor has been fabricated by immobilizing glucose oxidase (GOx) on unhybridized titanium dioxide nanotube arrays using an optimized cross-linking technique. The TiO2 nanotube arrays were synthesized directly on a titanium substrate by anodic oxidation. The structure and morphology of electrode material were characterized by X-ray diffraction and scanning electron microscopy. The electrochemical performances of the glucose biosensor were conducted by cyclic voltammetry and chronoamperometry measurements. It gives a linear response to glucose in the 0.05 to 0.65 mM concentration range, with a correlation coefficient of 0.9981, a sensitivity of 199.6 μA mM?1 cm?2, and a detection limit as low as 3.8 µM. This glucose biosensor exhibited high selectivity for glucose determination in the presence of ascorbic acid, sucrose and other common interfering substances. This glucose biosensor also performed good reproducibility and long-time storage stability. This optimized cross-linking technique could open a new avenue for other enzyme biosensors fabrication.
Figure
A schematic diagram for the fabrication of unhybridized TiO2 nanotube arrays glucose biosensor via optimized cross-linking technique.  相似文献   

12.
We describe the use of individual zinc oxide (ZnO) micro/nanowires in an electrochemical biosensor for uric acid. The wires were synthesized by chemical vapor deposition and possess uniform morphology and high crystallinity as revealed by scanning electron microscopy, X-ray diffraction, and photoluminescence studies. The enzyme uricase was then immobilized on the surface of the ZnO micro/nanowires by physical adsorption, and this was proven by Raman spectroscopy and fluorescence microscopy. The resulting uric acid biosensor undergoes fast electron transfer between the active site of the enzyme and the surface of the electrode. It displays high sensitivity (89.74 μA cm?2 mM?1) and a wide linear analytical range (between 0.1 mM and 0.59 mM concentrations of uric acid). This study also demonstrates the potential of the use of individual ZnO micro/nanowires for the construction of highly sensitive nano-sized biosensors.
Figure
Individual ZnO micro/nanowire based electrochemical biosensor was constructed. The biosensor displayed a higher sensitivity of 89.74 μA cm?2 mM?1 for uric acid detection.  相似文献   

13.
We report on a bienzyme-channeling sensor for sensing glucose without the aid of mediator. It was fabricated by cross-linking horseradish peroxidase (HRP) and glucose oxidase (GOx) on a glassy carbon electrode modified with multiwalled carbon nanotubes (MWNTs). The bienzyme was cross-linked with the MWNTs by glutaraldehyde and bovine serum albumin. The MWNTs were employed to accelerate the electron transfer between immobilized HRP and electrode. Glucose was sensed by amperometric reduction of enzymatically generated H2O2 at an applied voltage of ?50 mV (vs. Ag/AgCl). Factors influencing the preparation and performance of the bienzyme electrode were investigated in detail. The biosensor exhibited a fast and linear response to glucose in the concentration range from 0.4 to 15 mM, with a detection limit of 0.4 mM. The sensor exhibited good selectivity and durability, with a long-term relative standard deviation of <5 %. Analysis of glucose-spiked human serum samples yielded recoveries between 96 and 101 %.
Figure
A novel bienzyme-channeling sensor for glucose sensing has been constructed without the aid of mediator. This biosensor was fabricated by cross-linking horseradish peroxidase (HRP) and glucose oxidase (GOD) onto glass carbon electrode (GCE) modified with multiwall carbon nanotubes (MWNTs) which accelerated the electron transfer between the HRP and electrode.  相似文献   

14.
An electrochemical sensor was developed and tested for detection of L-tyrosine in the presence of epinephrine by surface modification of a glassy carbon electrode (GCE) with Nafion and cerium dioxide nanoparticles. Fabrication parameters of a surfactant-assisted precipitation method were optimized to produce 2–3 nm CeO2 nanoparticles with very high surface-to-volume ratio. The resulting nanocrystals were characterized structurally and morphologically by X-ray diffractometery (XRD), scanning and high resolution transmission electron microscopy (SEM and HR-TEM). The nanopowder is sonochemically dispersed in a Nafion solution which is then used to modify the surface of a GCE electrode. The electrochemical activity of L-tyrosine and epinephrine was investigated using both a Nafion-CeO2 coated and a bare GCE. The modified electrode exhibits a significant electrochemical oxidation effect of L-tyrosine in a 0.2 M Britton-Robinson (B-R) buffer solution of pH 2. The electro-oxidation peak current increases linearly with the L-tyrosine concentration in the molar concentration range of 2 to 160 μM. By employing differential pulse voltammetry (DPV) for simultaneous measurements, we detected two reproducible peaks for L-tyrosine and epinephrine in the same solution with a peak separation of about 443 mV. The detection limit of the sensor (signal to noise ratio of 3) for L-tyrosine is ~90 nM and the sensitivity is 0.20 μA μM?1, while for epinephrine these values are ~60 nM and 0.19 μA μM?1. The sensor exhibited excellent selectivity, sensitivity, reproducibility and stability as well as a very good recovery time in real human blood serum samples.
Simultaneous electrochemical determination of L-tyrosine and epinephrine in blood plasma with Nafion-CeO2/GCE modified electrode showing a 443 mV peak-to-peak potential difference between species oxidation peak currents.  相似文献   

15.
We describe a novel procedure for the synthesis of nitrogen-doped reduced graphene oxide (N-rGO). It is based on the thermal reduction of GO (dispersed in water) with sodium diethyldithiocarbamate that acts as both the reducing agent and the source for nitrogen. The surface morphology of the N-rGO is characterized using high resolution transmission electron microscopy. X-ray photoelectron spectroscopy was carried out to study the composition of their surface, and Raman spectroscopy was performed to study the level of doping with nitrogen and the structural order. The N-rGO was deposited on a glassy carbon electrode (GCE), and the resulting electrode utilized as a sensing platform for 4-nitrophenol (4-NP). The modified GCE exhibits a well-defined oxidation peak current that is about ten times larger when compared to that of a bare GCE. The electron transfer number, proton transfer number and electron transfer rate constant (ks 1.046 s?1) were determined. At optimized conditions, the oxidation peak current is linearly related to the concentration of 4-NP in the 20–500 nM range, with a correlation coefficient of 0.9917. The detection limit (at an SNR of 3) is 7 nM. The method was successfully applied to the analysis of waters spiked with 4-NP. Recoveries range from 97.8 to 102.6 %, and no interferences are found for common inorganic cations and anions. Figure
?  相似文献   

16.
We report on a highly sensitive and selective nonenzymatic glucose sensor based on a glassy carbon electrode modified with a composite prepared from nickel(II) hydroxide nanoplates and carbon nanofibers. The nanocomposite was characterized by scanning electron microscopy and powder X-ray diffraction. Electrodes modified with pure Ni(OH)2 and with the nanocomposite were characterized by electrochemical impedance spectroscopy. Cyclic voltammetric and amperometric methods were used to investigate the catalytic properties of the modified electrodes for glucose electrooxidation in strongly alkaline solution. The sensor exhibits a wide linear range (from 0.001 to 1.2 mM), a low detection limit (0.76 μM), fast response time (< 5 s), high sensitivity (1038.6 μA?·?mM?1?·?cm?2), good reproducibility, and long operational stability. Application of the nonenzymatic sensor for monitoring glucose in real samples was also demonstrated.
Figure
We report on a highly sensitive and selective nonenzymatic glucose sensor based on a glassy carbon electrode modified with a nanocomposite prepared from nickel (II) hydroxide nanoplates and carbon nanofibers. The facile preparation, high electrocatalytic activity, relatively fast response, favorable reproducibility and long-term performance stability demonstrate the potential applications of the sensor.  相似文献   

17.
This paper describes the synthesis, characterisation and application of a very sensitive electrochemical sensor based on a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNTs) decorated with homogeneously distributed spherical gold nanoparticles (AuNPs). These AuNPs presented diameters ranging from 2 to 10 nm. The AuNPs were prepared directly on the MWCNTs’ surface via a synthesis using HAuCl4 and citric acid as the reducing agent. The resulting material (Au/MWCNTs) was characterised by scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD) and Raman spectroscopy. The developed Au/MWCNTs sensor was used in the determination of nitric oxide (NO) in phosphate buffer solution at pH 4.4 by differential pulse voltammetry. In the potential window between 0.5 and 0.65 V, a well-defined oxidation peak was observed, whose height was proportional to the NO concentration in the solution. The Au/MWCNTs-modified electrode exhibited high sensitivity for the determination of nitric oxide, with the limit of detection being 0.21 nmol L?1 (S/N?=?3). No significant interference was detected for nitrite and CO2 in the NO detection. Our study demonstrated that the resultant Au/MWCNT-modified electrode can be used for nitric oxide detection in the presence of ascorbic acid, dopamine and uric acid, being potentially useful for determinations of NO in real samples. Figure
?  相似文献   

18.
We are presenting an electrochemical immunosensor for the determination of the β-agonist and food additive ractopamine. A glassy carbon electrode (GCE) was modified with gold nanoparticles and a film of a composite made from poly(arginine) and multi-walled carbon nanotubes. Antibody against ractopamine was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin. The assembly of the immunosensor was followed by electrochemical impedance spectroscopy. Results demonstrated that the semicircle diameter increases, indicating that the film formed on the surface hinders electron transfer due to formation of the antibody-antigen complex on the modified electrode. Under optimal conditions, the peak current obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The lower detection limit is 0.1 nmol?L?1. The sensor displays good stability and reproducibility. The method was applied to the analysis of spiked swine feed samples and gave satisfactory results. Figure
Immunoassay for ractopamine based on glassy carbon electrode modified with gold nanoparticles and a film of a composite made from poly (arginine) and multi-walled carbon nanotubes was proposed. Under optimal conditions, the peak currents obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The detection limit is 0.1 nmol?L?1.  相似文献   

19.
Green biosynthesis of nanoparticles and their applications in sensor field is of great interest to the researchers. We report herein a simple green approach for the synthesis of silver nanoparticles (Ag-NPs) using Acacia nilotica Willd twig bark and its application for the detection of 4-nitro phenol (4-NP). The synthesized Ag-NPs were characterized by Transmission electron microscopy, X-ray diffraction and elemental analysis. The size of synthesized Ag-NPs was in the range of 10–50 nm. The Ag-NPs modified electrode shows a high sensitivity and selectivity towards the sensing of 4-NP. The fabricated modified electrode shows a low detection limit of 15 nM on the wider linear response range from 100 nM to 350 μM with the sensitivity of 2.58?±?0.05 μAμM?1 cm?2. In addition, the fabricated sensor shows good repeatability and reproducibility.
Figure
The schematic representation of the fabrication of Ag-NPs and application of 4-nitrophenol sensing  相似文献   

20.
Previously, we have prepared nanoflake-like tin disulfide (SnS2) and used for the immobilization of proteins and biosensing. We have now modified an electrode with a composite consisting of nanoflake-like SnS2 decorated with gold nanoparticles (Au-NPs) and have immobilized glucose oxidase (GOx) on its surface in order to study its direct electrochemistry. Scanning electron microscopy, electrochemical impedance spectroscopy, Fourier transform IR spectroscopy and cyclic voltammetry were used to examine the interaction between GOx and the AuNP-SnS2 film. It is shown that the composite film has a larger surface area and offers a microenvironment that facilitates the direct electron transfer between enzyme and electrode surface. The immobilized enzyme retains its bioactivity and undergoes a surface-controlled, reversible 2-proton and 2-electron transfer reaction, with an apparent electron transfer rate constant of 3.87 s -1. Compared to the nanoflake-like SnS2-based glucose sensor, the GOx-based biosensor exhibits a lower detection limit (1.0 :M), a better sensitivity (21.8 mA?M -1 ?cm -2), and a wider linear range (from 0.02 to 1.3 mM). The sensor displays excellent selectivity, good reproducibility, and acceptable stability. It was successfully applied to reagentless sensing of glucose at ?0.43 V.
Figure
The AuNPs decorated nanoflake-like SnS2 (AuNPs–SnS2) composite is for the first time prepared and used to construct novel glucose biosensor nanoflake-like SnS2 was firstly synthesized and SEM image of the nanoflake-like SnS2 (a) and TEM images of the nanoflake-like SnS2 (b), AuNPs (c) and AuNPs–SnS2 (d) are shown in above figure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号