首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The rapid emergence of drug resistance to the current antimalarial agents has led to the urgent need for the discovery of new and effective compounds. In this work, a series of 5-phenoxy primaquine analogs with 8-aminoquinoline core (7a–7h) was synthesized and investigated for their antimalarial activity against Plasmodium falciparum. Most analogs showed improved blood antimalarial activity compared to the original primaquine. To further explore a drug hybrid strategy, a conjugate compound between tetraoxane and the representative 5-phenoxy-primaquine analog 7a was synthesized. In our work, the hybrid compound 12 exhibited almost a 30-fold increase in the blood antimalarial activity (IC50 = 0.38 ± 0.11 μM) compared to that of primaquine, with relatively low toxicity against mammalian cells (SI = 45.61). Furthermore, we found that these 5-phenoxy primaquine analogs and the hybrid exhibit significant heme polymerization inhibition, an activity similar to that of chloroquine, which could contribute to their improved antimalarial activity. The 5-phenoxy primaquine analogs and the tetraoxane hybrid could serve as promising candidates for the further development of antimalarial agents.  相似文献   

2.
The clinical formulation of primaquine (PQ) is a mixture of (−)‐(R)‐ and (+)‐(S)‐ primaquine enantiomers which may show different pharmacokinetic and pharmacodynamic properties. To assess the efficacy and toxicity of primaquine enantiomers, a method using LC‐MSD‐TOF has been developed. The enantiomers were well separated using a Chiralcel OD column (250 × 4.6 mm, 10 µm) with a linear gradient of mobile phase consisting of acetonitrile (0.1% formic acid) and aqueous ammonium formate (20 mm ; 0.1% formic acid) adjusted to pH 5.9 at a flow rate of 0.7 mL/min. The method was validated for linearity, precision, accuracy and limits of detection and quantification. The calibration curves were linear with all correlation coefficients being >0.999. The average recoveries of (−)‐(R)‐ and (+)‐(S)‐primaquine and (−)‐(R)‐ and (+)‐(S)‐carboxyprimaquine were 88 and 92%, respectively, in spiked human plasma and 89 and 93% respectively in spiked mouse plasma samples. The RSD of (−)‐(R)‐ and (+)‐(S)‐primaquine and (−)‐(R)‐ and (+)‐(S)‐carboxyprimaquine were 2.15, 1.74, 1.73 and 2.31, respectively, in spiked human plasma and 2.21, 1.09, 1.95 and 1.17% in spiked mouse plasma, respectively. The intra‐day and inter‐day precisions expressed as RSD were lower than 10% in all analyzed quality control levels. The method as reported is suitable for study of the pharmacokinetic and pharmacodynamic properties of the enantiomers of primaquine. The method was successfully applied to study plasma pharmacokinetic profile of enantiomers of primaquine and carboxyprimaquine in mice administered with primaquine in racemic form. The analytical method was found to be linear, accurate, precise and specific. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive and efficient liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of piperaquine (PQ) and its N ‐oxidated metabolite (PQ‐M) in plasma. A simple protein precipitation procedure was used for sample preparation. Adequate chromatographic retention was achieved on a C18 column under gradient elution with acetonitrile and 2 mm aqueous ammonium acetate containing 0.15% formic acid and 0.05% trifluoroacetic acid. A triple‐quadrupole mass spectrometer equipped with an electrospray source was set up in the positive ion mode and multiple reaction monitoring mode. The method was linear in the range of 2.0–400.0 ng/mL for PQ and 1.0–50.0 ng/mL for PQ‐M with suitable accuracy, precision and extraction recovery. The lower limits of detection (LLOD) were established at 0.4 and 0.2 ng/mL for PQ and PQ‐M, respectively, using 40 μL of plasma sample. The matrix effect was negligible under the current conditions. No effect was found for co‐administrated artemisinin drugs or hemolysis on the quantification of PQ and PQ‐M. Stability testing showed that two analytes remained stable under all relevant analytical conditions. The validated method was successfully applied to a pharmacokinetic study performed in rats after a single oral administration of PQ (60 mg/kg).  相似文献   

4.
A suitable HPLC method has been selected and validated for rapid simultaneous separation and determination of four imidazole anti-infective drugs, secnidazole, omeprazole, albendazole, and fenbendazole, in their final dosage forms, in addition to human plasma within 5 min. The method suitability was derived from the superiority of using the environmentally benign solvent, methanol over acetonitrile as a mobile phase component in respect of safety issues and migration times. Separation of the four anti-infective drugs was performed on a Thermo Scientific® BDS Hypersil C8 column (5 µm, 2.50 × 4.60 mm) using a mobile phase consist of MeOH: 0.025 M KH2PO4 (70:30, v/v) adjusted to pH 3.20 with ortho-phosphoric acid at room temperature. The flow rate was 1.00 mL/min and maximum absorption was measured with UV detector set at 300 nm. Limits of detection were reported to be 0.41, 0.13, 0.18, and 0.15 µg/mL for secnidazole, omeprazole, albendazole, and fenbendazole, respectively, showing a high degree of the method sensitivity. The method of analysis was validated according to Food and Drug Administration (FDA)guidelines for the determination of the drugs, either in their dosage forms with highly precise recoveries, or clinically in human plasma, especially regarding pharmacokinetic and bioequivalence studies.  相似文献   

5.
《Analytical letters》2012,45(13):1671-1685
Abstract

A method has been developed to estimate primaquine in whole blood and urine by sensitive and selective high-performance liquid chromatography. Using the linear chain analogue of primaquine as the internal standard, a single-step extraction, normal-phase silica column with a basic mobile phase, levels down to 1 ng/ml of primaquine could be measured with good precision. Other anti-malarials like amodiaquine and pyrimethamine did not interfere in the assay. The major carboxylic acid metabolite of primaquine did not elute under the normal-phase chromatographic conditions. The method is suitable for use in clinical pharmacokinetic studies with primaquine.  相似文献   

6.
In the present study, a sensitive and fully validated bioanalytical high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitative determination of three newly synthesized carbonic anhydrases inhibitors (CAIs) with potential antitumor activity in human plasma. The analytes and the internal standard (IS) were extracted using 1.5 mL acetonitrile from only 450 µL aliquots of human plasma to achieve the desired protein precipitation. Chromatographic separations were achieved on Phenomenex Kinetex® C18 column (100 × 4.6 mm, 2.6 µm) using a binary gradient elution mode with a run time of less than 6 min. The mobile phase consisted of solvent (A): 0.1% formic acid in 50% methanol and solvent B: 0.1% formic acid in acetonitrile (30:70, v/v), pumped at a flow rate of 0.8 mL/min. Detection was employed using triple quadrupole tandem mass spectrometer (API 3500) equipped with an electrospray ionization (ESI) source in the positive ion mode. Multiple reaction monitoring (MRM) mode was selected for quantitation through monitoring the precursor-to-parent ion transition at m/z 291.9 → 173.0, m/z 396.9 → 225.1, m/z 388.9 → 217.0, and m/z 146.9 → 91.0 for AW-9a, WES-1, WES-2, and Coumarin (IS), respectively. Linearity was computed using the weighted least-squares linear regression method (1/x2) over a concentration range of 1–1000, 2.5–800, and 5–500 ng/mL for AW-9a, WES-1, and WES-2; respectively. The bioanalytical LC-MS/MS method was fully validated as per U.S. Food and Drug Administration (FDA) guidelines with all respect to linearity, accuracy, precision, carry-over, selectivity, dilution integrity, and stability. The proposed LC-MS/MS method was applied successfully for the determination of all investigated drugs in spiked human plasma with no significant matrix effect, which is a crucial cornerstone in further therapeutic drug monitoring of newly developed therapeutic agents.  相似文献   

7.
林强  杨超  李美丽  王佳  侯瀚然  邵兵  牛宇敏 《色谱》2023,41(3):274-280
人体生物基质中麻痹性贝类毒素的检测对其引起的食物中毒诊断和救治具有重要意义。研究建立了超高效液相色谱-串联质谱法测定血浆、尿液中14种麻痹性贝类毒素的分析方法。实验比较了不同固相萃取柱的影响,优化了前处理条件和色谱条件,血浆样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取后直接上机测定,尿液样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取,聚酰胺(PA)固相萃取柱净化后上机测定。采用Poroshell 120 HILIC-Z色谱柱(100 mm×2.1 mm,2.7μm)对14种贝类毒素进行分离,流动相为含0.1%(v/v)甲酸的5 mmoL/L甲酸铵缓冲溶液和0.1%(v/v)甲酸乙腈溶液,流速为0.50 mL/min。在电喷雾模式(ESI)下进行正负离子扫描,采用多反应监测(MRM)模式检测,外标法定量。结果表明,对于血浆和尿液样品,14种贝类毒素分别在0.24~84.06 ng/mL范围内线性关系良好,相关系数均大于0.995。尿液检测的定量限为4.80~34.40 ng/mL,血浆检测的定量限为1.68~12.04 ng/mL。尿液和血浆样品在1、2和10倍定量限加标水平下平均回收率为70.4%~123.4%,日内精密度为2.3%~19.1%,日间精密度为4.0%~16.2%。应用建立的方法对腹腔注射14种贝类毒素小鼠血浆和尿液进行测定,20份血浆样本中检出含量分别为19.40~55.60μg/L和8.75~13.86μg/L。该方法操作简便,样品取样量少,方法灵敏度高,适用于血浆和尿液中麻痹性贝类毒素的快速检测。  相似文献   

8.
Bortocan R  Bonato PS 《Electrophoresis》2004,25(16):2848-2853
An enantioselective capillary electrophoresis method for the simultaneous determination of primaquine (PQ) and carboxyprimaquine (CPQ) in rat liver mitochondrial fraction, suitable for in vitro metabolism studies is presented. The drug and metabolite were extracted by liquid-liquid extraction using ethyl ether. The enantiomers were resolved in a fused-silica capillary, 50 microm inside diameter (ID) and 24 cm of effective length, using an electrolyte solution consisting of a 20 mmol/L sodium phosphate solution, pH 3.0, and 10% w/v maltodextrin. Hydrodynamic sample injection was used with a 10 s injection time at 50 mbar pressure. The applied voltage was 22 kV and the capillary temperature was controlled at 20 degrees C. Detection was carried out at 264 nm. Under these conditions, the enantiomeric fractions of the drug and of its metabolite were analyzed within 6 min. The extraction procedure was efficient in removing endogenous interferents and low values (<10%) for the coefficients of variation and deviation from theoretical values were demonstrated for both within-day and between-day assays. The method described allows the determination of PQ and CPQ enantiomers as low as 100 and 40 ng/mL, respectively. After validation, the method was used for an in vitro metabolism study of PQ. The results showed that the enantiomer (-)-PQ was preferentially metabolized to (-)-CPQ.  相似文献   

9.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

10.
High performance liquid chromatography with ultra-violet detection (HPLC-UV) and gas chromatography–mass spectrometry (GC-MS) methods were developed and validated for the determination of chlorambucil (CLB) and valproic acid (VPA) in plasma, as a part of experiments on their anticancer activity in chronic lymphocytic leukemia (CLL). CLB was extracted from 250 µL of plasma with methanol, using simple protein precipitation and filtration. Chromatography was carried out on a LiChrospher 100 RP-18 end-capped column using a mobile phase consisting of acetonitrile, water and formic acid, and detection at 258 nm. The lowest limit of detection LLOQ was found to be 0.075 μg/mL, showing sufficient sensitivity in relation to therapeutic concentrations of CLB in plasma. The accuracy was from 94.13% to 101.12%, while the intra- and inter-batch precision was ≤9.46%. For quantitation of VPA, a sensitive GC-MS method was developed involving simple pre-column esterification with methanol and extraction with hexane. Chromatography was achieved on an HP-5MSUI column and monitored by MS with an electron impact ionization and selective ion monitoring mode. Using 250 µL of plasma, the LLOQ was found to be 0.075 μg/mL. The accuracy was from 94.96% to 109.12%, while the intra- and inter-batch precision was ≤6.69%. Thus, both methods fulfilled the requirements of FDA guidelines for the determination of drugs in biological materials.  相似文献   

11.
A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.  相似文献   

12.
The oxidation of lomefloxacin (LOM) and balofloxacin (BAL) under the influence of azo initiator of radical reactions of 4,4′-azobis(4-cyanopentanoic acid) (ACVA) and H2O2 was examined. Oxidation using H2O2 was performed at room temperature while using ACVA at temperatures: 40, 50, 60 °C. Additionally, the oxidation process of BAL under the influence of KMnO4 in an acidic medium was investigated. New stability-indicating HPLC methods were developed in order to evaluate the oxidation process. Chromatographic analysis was carried out using the Kinetex 5u XB—C18 100A column, Phenomenex (Torrance, CA, USA) (250 × 4.6 mm, 5 μm particle size, core shell type). The chromatographic separation was achieved while using isocratic elution and a mobile phase with the composition of 0.05 M phosphate buffer (pH = 3.20 adjusted with o-phosphoric acid) and acetonitrile (87:13 v/v for LOM; 80:20 v/v for BAL). The column was maintained at 30 °C. The methods were validated according to the ICH guidelines, and it was found that they met the acceptance criteria. An oxidation process followed kinetics of the second order reaction. The most probable structures of LOM and BAL degradation products formed were assigned by the UHPLC/MS/MS method.  相似文献   

13.
N-(n-butyl) thiophosphoric triamide (NBPT) is a urease inhibitor utilised in urea-based fertilizers. In Ireland, fertilizer treated with NBPT is applied to pasture to mitigate both ammonia and nitrous oxide emissions, but concerns arise as to the potential for residues in milk products. A quick ultrafiltration extraction and ultra-high performance liquid chromatography coupled with mass spectrometry triple quadrupole (UHPLC-MS/MS) quantitation method was developed and validated in this study. The method was applied in the analysis of samples collected from a field study investigating potential transfer of NBPT residues into milk. NBPT and NBPTo residues, were extracted from fortified milk samples and analysed on a UHPLC-MS/MS with recoveries ranging from 74 to 114%. Validation of the UHPLC-MS/MS method at low (0.0020 mg kg−1) and high (0.0250 mg kg−1) concentration levels in line with SANTE/12682/2019 showed overall trueness in the range of 99 to 104% and precision between 1 and 10%, RSD for both compounds. The limit of quantitation (LOQ) was 0.0020 mg kg−1 and other tested parameters (linearity, sensitivity, specificity, matrix effect, robustness, etc.) satisfied acceptance criteria. Stability assessment using spiked samples revealed the compounds were stable in raw and pasteurised milk for 4 weeks at –80 °C storage temperature. Maintaining samples at pH 8.5–9.0 further improved stability. Analysis of 516 milk samples from the field study found that NBPT and NBPTo concentrations were below the LOQ of 0.0020 mg kg−1, thus suggesting very low risk of residues occurring in the milk. The method developed is quick, robust, and sensitive. The method is deemed fit-for-purpose for the simultaneous determination of NBPT and NBPTo in milk.  相似文献   

14.
张秀尧  蔡欣欣  张晓艺  李瑞芬 《色谱》2020,38(11):1294-1301
百草枯和敌草快是广泛使用的非选择性触杀型除草剂,中毒后会造成急性肺损伤,病死率高,同时监测血浆和尿液中百草枯和敌草快的浓度,可以为临床早期诊断和预后提供有价值的信息。血浆和尿液中百草枯和敌草快的主要检测方法为液相色谱-质谱法。百草枯和敌草快为强极性水溶性化合物,在反相色谱柱上难以保留,多采用离子对色谱法或亲水色谱法进行分离。采用离子对色谱法时,加入的离子对试剂有离子抑制作用,降低了质谱检测的灵敏度,还给质谱系统增加了额外的污染;亲水色谱法易受基质成分影响,保留时间不稳定。考虑到百草枯和敌草快在水溶液中以双电荷联吡啶离子状态存在,更适合采用阳离子交换色谱法,建立了离子色谱-三重四极杆质谱测定血浆和尿液中百草枯和敌草快的检测方法。血浆和尿液样品经水稀释后,直接过混合型聚合物反相吸附和弱阳离子交换固相萃取柱(Oasis WCX)净化,经IonPac CS 18型阳离子色谱柱(250 mm×2.0 mm,6.0 μm)分离,以自动在线产生的甲磺酸进行梯度洗脱,色谱柱流出液经阳离子抑制器抑制后进入质谱系统,在ESI+ 、多反应监测(MRM)模式下检测,稳定同位素内标法定量。百草枯和敌草快分别在1.0~150 μg/L和0.5~75 μg/L范围内线性关系良好,血浆中的平均基质效应分别为84.2%~89.3%和84.7%~91.1%,尿液中平均基质效应分别为50.3%~58.4%和51.9%~59.4%;血浆中百草枯和敌草快的平均加标回收率分别为93.5%~117%和91.7%~112%,相对标准偏差(RSD)分别为3.4%~16.7%和2.8%~13.2%;尿液中百草枯和敌草快的平均加标回收率分别为90.0%~118%和99.2%~116%,RSD分别为5.6%~14.9%和2.4%~17.3%(n =6);血浆和尿液中百草枯和敌草快的检出限分别0.3 μg/L和0.2 μg/L,定量限分别为1.0 μg/L和0.5 μg/L。该法灵敏度高,准确性好,可用于血浆和尿液中百草枯和敌草快的中毒检测。  相似文献   

15.
A simple and sensitive high-performance liquid chromatographic method has been developed for determination of chlorogenic acid in rat plasma. Chlorogenic acid was extracted from plasma samples with methanol. HPLC analysis of the extracts was performed on a C18 column (250 mm × 4.6 mm i.d., 5 µm particles). The mobile phase was acetonitrile −1% formic acid (9:91, v/v). The calibration plot was linear over the range 0.0420–2.10 µg mL−1 and the lower limit of quantification was 0.0420 µg mL−1. The method was reproducible and reliable with intra-day precision better than 8.2%, inter-day precision better than 9.1%, accuracy within ±8.3%, and mean extraction recovery above 84.4%. The validated method was successfully applied to pharmacokinetic studies of chlorogenic acid in rat plasma after administration of Luying decoction.  相似文献   

16.
NPC1161 is an 8-aminoquinoline anti-malarial analog, which has a favorable toxicity profile relative to primaquine and other 8-aminoquinolines. High-performance liquid chromatographic method was developed for the determination of NPC1161, primaquine and their metabolites in biological samples in order to facilitate metabolic and pharmacokinetic studies. The method includes extraction of the unchanged drugs and their metabolites from the biological samples. Separation was achieved by reversed-phase chromatography on a C18 column with water–acetonitrile both containing 0.025% trifluoroacetic acid as the mobile phase. Recoveries of NPC1161 and its metabolites were greater than 60% in various biological samples tested. No interference with the components of the biological material was observed. The detector response was linear with concentrations of NPC1161 and its metabolites (desalkyl NPC1161 and carboxy NPC1161) in the ranges from 0.5 to 80.0, 0.4–60.0 and 0.4–70.0 μg mL−1, respectively. A mass spectrometry coupled with electrospray ionization (ESI) interface method is described for the identification of NPC1161 and its metabolites in biological samples. This method involved the use of the [M + H]+ions of NPC1161, C3 analog (internal std. for the assay), desalkyl NPC1161 and carboxy NPC1161 at m/z 434, 406, 349 and 449 in the positive ion mode with extractive ion monitoring (EIM). This method will have an important application in pharmacokinetic studies of NPC1161 and in understanding the mechanism of metabolism of this novel 8-aminoquinoline analog in more detail.  相似文献   

17.
A capillary zone electrophoretic method has been developed and validated for the determination of the impurity quinocide (QC) in the antimalarial drug primaquine (PQ). Different buffer additives such as native cyclodextrins and crown ethers were evaluated. Promising results were obtained when either β‐cyclodextrin (β‐CD) or 18‐crown‐6 ether (18C6) were used. Their separation conditions such as type of buffer and its pH, buffer additive concentration, applied voltage capillary temperature and injection time were optimized. The use of 18C6 offers slight advantages over β‐CD such as faster elution times and improved resolution. Nevertheless, migration times of less than 5 min and resolution factors (Rs) in the range of 2–4 were obtained when both additives were used. The method was validated with respect to selectivity, linearity, limits of detection and quantitation, analytical precision (intra‐ and inter‐day variability) and repeatability. Concentrations of 2.12 and 2.71% (w/w) of QC were found in pharmaceutical preparations of PQ from two different manufacturers. A possible mechanism for the successful separation of the isomers is also discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Rivaroxaban is an oral anticoagulant directly inhibiting the activity of Factor Xa, which is widely used for the prophylaxis of thromboembolic disorders. Therapeutic drug monitoring (TDM) is required during therapy for individual dosage adjustment. This study aimed at developing a liquid chromatography/tandem mass spectrometry method that was suitable for rivaroxaban TDM in human plasma and urine and exploring the feasibility of urine drug monitoring in medical care. A 3 min run time of the LC–MS/MS methods was established by employing an Acquity UPLC BEH C18 (2.1 × 50 mm, 1.7 μm) column using gradient elution of 10 mmol/L ammonium acetate containing 0.1% formic acid–0.1% formic acid acetonitrile as a mobile phase at a flow rate of 0.4 ml/min with calibration ranges of 0.5–400 and 10–10,000 ng/ml for human plasma and urine, respectively. Rivaroxaban was detected on a triple quadrupole tandem mass spectrometer with an electrospray ionization source in positive ion mode. The methods showed good linearity within the calibration range. The precision and accuracy, matrix effect, extraction recovery and stability in both human matrices were all validated and meet the international guideline requirements. These validated methods were successfully applied to support the TDM of an aged patient receiving rivaroxaban for therapy.  相似文献   

19.
Summary Mizolastine (SL 85.0324) is a new antihistaminic H1 benzimidazole derivative which is excreted into urine almost completely metabolized; about 2% of the unchanged drug is excreted as conjugated compound which requires enzymatic deconjugation before analysis. Since the existing methods for plasma samples do not work on deconjugated human urine due to interferences, a new method was developed. The method is based on a diethyl-ether extraction of mizolastine and an internal standard from alkalinized urine. The ether extract is back-extracted with an aqueous buffer (pH=2.6), this extract is neutralized (pH=6.5) and an aliquot injected into a C18 pre-column where clean up and preconcentration take place. The analytes are then desorbed from the pre-column and transferred to the analytical column. The analytical column is a C18 type specially seactivated for basic compounds with an eluent of acetonitrile/phosphate solution (pH=4.5), 40/60, v/v, at a flow rate of 1 ml min–1. Detection is at 285 nm. The method is linear in the range 10–500 ng ml–1 with a lower limit of detection of 10 ng ml–1. The precision and accuracy, evaluated during intra-day and inter-day assays, are satisfactory for pharmacokinetic investigations.  相似文献   

20.
A second generation of 4-aminoquinoline- and 8-aminoquinoline-based tetrazoles and lactams were synthesized via the Staudinger and Ugi multicomponent reactions. These compounds were subsequently evaluated in vitro for their potential antiplasmodium activity against a multidrug-resistant K1 strain and for their antitrypanosomal activity against a cultured T. b. rhodesiense STIB900 strain. Several of these compounds (4a–g) displayed good antiplasmodium activities (IC50 = 0.20–0.62 µM) that were comparable to the reference drugs, while their antitrypanosomal activity was moderate (<20 µM). Compound 4e was 2-fold more active than primaquine and was also the most active (IC50 = 7.01 µM) against T. b. rhodesiense and also exhibited excellent aqueous solubility (>200 µM) at pH 7.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号