1.
<正>实验人员在进行日常监测分析的精密度和准确度试验时,应选择更具代表性和操作性强的标准样品或质量控制样品进行试验,即要求使用与实际样品基体接近的标准样品或质量控制样品。但环境监测领域有时很难找到与此类标准样品或质控样品,这就需要模拟实际样品配制人工合成标准样品或质控样品进行质量控制,尤其是低浓度水平的基体质控样品——实验室强化空白[1]的制备(本工作提出的实验室强化空白的概念与文献[1]的解释有所不  相似文献   

2.
采用顶空气相色谱法测定工作场所空气中的乙酸乙酯。气态乙酸乙酯用活性炭管吸附,二氯甲烷解吸,顶空进样,HP–FFAP毛细管柱分离,FID检测器测定,峰面积定量。乙酸乙酯的质量浓度在1.76~880.0μg/m L范围内与色谱峰面积呈良好的线性,相关系数r=0.999 4。不同浓度样品批内测定结果的相对标准偏差为1.34%~3.61%(n=7),批间测定结果的相对标准偏差为1.04%~4.78%(n=7),加标回收率为91.02%~100.29%,方法检出限为0.32μg/m L,解吸效率为91.28%~95.19%。对于100 mg活性炭,乙酸乙酯的穿透容大于2.2 mg,当其浓度在17.6~17 600 mg/m3时,采样效率为91.23%~97.40%,常温下可以保存10 d。该方法各项指标均达到《工作场所空气中有毒物质检测方法研制规范》的要求,适用于工作场所空气中乙酸乙酯的现场监测。  相似文献   

3.
建立电热原子吸收法测定水中总钼的含量。样品采用硝酸–过氧化氢消解,热解涂层石墨管减小记忆效应,塞曼背景校正消除背景噪声。检测了27种共存离子的干扰影响。经6家实验室对标准物质和实际样品检测验证,方法检出限为0.6μg/L,能够满足微量检测要求。钼测定结果相对误差最大值为–6.2%,实验室内相对标准偏差为4.5%~7.6%(n=6),实验室间相对标准偏差为4.3%~5.7%(n=6),加标回收率为91.8%~104.0%。该方法精密度和准确度满足我国地下水和废水监测技术规范的质控要求。  相似文献   

4.
天然水体样品中甲基汞含量极低,因此,在样品采集及保存的过程中,必须选择合适材质的试剂瓶进行采样与保存,最低限度的减少试剂瓶空白对样品中甲基汞含量的影响。本文选取了聚丙烯(PP)、玻璃(Glass)、高密度聚乙烯(HDPE)和低密度聚乙烯(LDPE)、聚碳酸酯(PC)以及可溶性聚四氟乙烯(PFA)6种材质的实验室级试剂瓶,分别进行了5h、5d的空白测试,以及部分材质试剂瓶倒置及平置空白条件测试。结果表明:PP、PC和PFA的试剂瓶空白值基本可以忽略不计。综合考虑经济、便携等因素,Corning PP离心管适合不清洗直接用于野外采样分析。  相似文献   

5.
建立环境空气中7种丙烯酸酯类的气相色谱测定的方法。将活性炭吸附管与大气采样器连接,在0.5L/min流量下采集空气样品20 min,采样后的活性炭用1.0 mL二氯甲烷解吸,以氢火焰离子化为检测器,气相色谱法测定7种丙烯酸酯类的含量。结果表明,7种丙烯酸酯类的质量浓度在1~100μg/mL范围内与色谱峰面积线性关系良好,相关系数均大于0.999 5,当采样体积为10 L时,方法检出限为0.010~0.017 mg/m~3。各组分平均空白加标回收率为84%~120%,测定结果的相对标准偏差为2.2%~15.0%(n=6)。该方法样品处理简单,精密度与准确度高,检出限低,抗干扰,便于在实验室推广和应用。  相似文献   

6.
气相分子吸收光谱法测定环境地表水中氨氮含量的标准方法研究还不全面,因此考察了水样的保存、亚硝酸盐、Ca^(2+)、Mg^(2+)、I^(-)、硫化物对其测定结果的影响.结果表明,采集地表水样后立即加入硫酸使水样酸化至pH<2,密闭,可延长样品保存时间至7 d,但尽量在24 h内进行测定;气相分子吸收光谱法测定氨氮水样时,当亚硝酸盐含量较高时,在氨氮除亚氮功能模式下已不能消除干扰,必须在水样分析前采用加热煮沸或预蒸馏前处理方式;水中Ca^(2+)、Mg^(2+)、25倍以下质量浓度的I^(-)和10倍质量浓度以下的硫化物对气相分子吸收光谱法氨氮测定没有显著干扰.本方法的检出限(3.143s)为0.02 mg·L^(-1),按标准加入法进行回收试验,回收率为94.7%~101%,测定值的相对标准偏差(n=6)为0.70%~4.7%.采用气相分子吸收光谱法分析标准样品,其测定结果均在标准样品认定值的允许偏差范围内.与纳氏试剂分光光度法的测定结果相比,预蒸馏-气相分子吸收光谱法具有更好的精密度和准确度.  相似文献   

7.
通过对前处理方法的比较,选择了快速溶剂萃取作为可吸入颗粒物中多环芳烃的提取方式,并且将ASE的萃取条件作了优化实验,确定ASE的优化结果为DCM:HEX=2:1,萃取温度为120℃,萃取压力为10.34 MPa。处理完的样品上气相色谱质谱-质谱测定,得到空白样品中24种PAHs均有检出,实际样品中的含量均低于10 ng/m L,6种替代物的标准曲线的相关系数在0.999以上,24种PAHs标准样品作了3个不同浓度范围的标准曲线,相关系数均在0.99以上。空白加标实验中得到6种替代物的回收率在58.7%~108.2%之间,24种PAHs的平均回收率在88.3%~104.0%之间,相对标准偏差均低于9.0%。样品加标实验中6种替代物的加标回收率在60.0%~106.5%之间,24种PAHs的回收率在78.0%~95.0%之间,相对标准偏差均低于6.0%。  相似文献   

8.
以商购罗丹明B为原料,进行重结晶提纯,制备罗丹明B纯度标准物质。采用红外光谱(IR)、高分辨质谱和核磁共振谱(NMR)进行定性分析。样品分装400瓶后,依据国家《一级标准物质研制技术规范》,采用液相色谱-二极管阵列法对随机抽取的15瓶样品进行均匀性检验,经F检验表明,在95%的置信区间范围内,样品均匀性良好。在室温下,经过30个月稳定性考察,结果表明样品稳定性良好。标准物质经国内8家具有分析资质的实验室进行协同定值,定值结果为99.0%,扩展不确定度为1.0%(k=2)。该标准物质达到了国家标准物质的技术要求,可用于有关罗丹明B的分析方法校正和质量控制。  相似文献   

9.
改进了实验室建立的测定脱氢乙酸的胶束电动毛细管色谱(MEKC)和国标的液相色谱(LC)的分离及样品前处理方法. 改进后的两种方法均能准确测定6类重点食品中的脱氢乙酸,为重新评估脱氢乙酸的风险、修订或制定其在不同食品中的限量标准提供依据. 改进后的MEKC和LC方法的检出限及定量限分别为0.2、0.5 mg/L和0.05、0.2 mg/L. 6类重点食品空白基质的加标回收率均在81.9%~116.0%之间,相对标准偏差在0.4%~7.3%之间. 测定了284件食品样品,结果均无超标. 使用改进的两种方法同时测定了45件样品,对其中20件阳性样品的结果进行了比较,结果吻合. 改进后的MEKC及LC方法样品前处理简单,非常适合大量样品检测.  相似文献   

10.
《化学分析计量》2008,17(1):75-75
为贯彻《中华人民共和国环境保护法》,保护环境,保障人体健康,提高环境管理水平,规范环境监测工作,现批准《固定源废气监测技术规范》等4项标准为国家环境保护标准,并予发布。标准名称、编号如下:  相似文献   

11.
建立了电热板蒸发–重量法测定水中全盐量的方法。采用电热板对过滤后的水样进行蒸发预处理,然后以重量法测定样品中的全盐量。取样体积为100 m L,以陶瓷蒸发皿为容器,恒重指标为质量偏差±0.5 mg,设置电热板蒸发温度为350℃,以差减重量法测定水中全盐量,方法线性范围为40~2 000 mg/L,检出限为10 mg/L,3种质量浓度水平实际样品的加标回收率在90.2%~110%之间,样品测定结果的相对标准偏差为2.8%~5.2%(n=6),有证标准物质测定结果与标准值相对误差为–1.9%~2.1%。该方法准确度高、稳定性好,适用于水中全盐量的测定。  相似文献   

12.
建立盘式固相萃取–超高效液相色谱–串联质谱(UPLC–MS–MS)快速测定环境水样中3种微囊藻毒素(MCs)的方法。环境水样经过盘式固相萃取柱净化,采用Waters BEH C_(18)色谱小柱,以乙腈–0.2%甲酸水溶液为流动相,梯度洗脱分离后,UPLC–MS–MS多级监测正离子模式下外标法进行定性定量分析。3种微囊藻毒素在0.05~10.0μg/L范围内呈现良好线性关系,相关系数均大于0.999 4,方法检出限为0.02 ng/L。对同一环境样品进行0.1,1.0,5.0μg/L 3种浓度的加标回收试验,平均回收率为82.8%~108.8%,测定结果的相对标准偏差为2.1%~10.1%(n=6)。该方法快速、灵敏、准确,可有效应用于环境水样中微囊藻毒素的监测。  相似文献   

13.
建立液相色谱–串联质谱法测定甘蓝中4-羟基百菌清残留的方法。以乙腈提取样品中的4-羟基百菌清,采用电喷雾负离子源(ESI–)和多重反应监测(MRM)模式测定,基质匹配标准工作曲线法定量。结果表明,甘蓝中4-羟基百菌清的质量浓度与其色谱峰面积呈良好的线性关系(r=0.999),线性范围为1.0~100μg/L,方法检出限为0.31μg/kg,定量限为1.0μg/kg。在5,10,50μg/kg 3个添加水平下,方法的回收率为88.0%~91.4%,测定结果的相对标准偏差为4.6%~7.2%(n=6)。该法简单、准确、快速、灵敏,符合法规残留限量监测要求。  相似文献   

14.
Four commonly found pesticides (alachlor, atrazine, metolachlor, and simazine) in surface water were determined using dispersive pipette extraction followed by gas chromatography–mass spectrometry. The rapid mixing and equilibrium between the dispersive pipette extraction adsorbent and water sample resulted in fast and efficient extraction. Using only 5?mL of water sample, the estimated time consumption for extraction of each sample was less than 5?min. Method validation was performed to evaluate accuracy, precision, linearity, the limits of detection, and the limits of quantitation. Average recovery of above 90% was obtained with relative standard deviations below 10%, which indicated good accuracy and precision of the dispersive pipette extraction method. Coefficients of determination were all above 0.9901 and showed good linearity. For the four pesticides studied using the current method, the limits of detection ranged from 7 to 40?ng?L?1, and limits of quantitation were from 20 to 130?ng?L?1. Method validation results supported the application of the current method for drinking water safety monitoring per National Primary Drinking Water Regulations established by the US Environmental Protection Agency. Water samples from Lake Lanier and Stone Mountain Lake (Georgia, USS) were analyzed with this method as a preliminary work for a larger scale drinking water quality study in the future. Trace amounts of simazine and atrazine were found in lake water samples, but both were below the regulation levels of the US Environmental Protection Agency.  相似文献   

15.
为监测畜禽养殖场对周围土壤环境的污染程度,选择重庆市50个养殖场作为样本,对其附近的土壤进行采样分析。将新鲜的土壤样品加入适量的硝酸、盐酸、氢氟酸、高氯酸高温消解后赶酸,最后定容至50 mL,利用以水作载流的氢化物发生-原子荧光光谱仪(WC-HG-AFS)测定了其中的砷(As)含量。结果表明,在5.000~100.000 mg/kg范围内线性相关系数R2=0.99997,检出限为0.074 mg/kg,样品的相对标准偏差(RSD)为1.6%,5份平行样品分析结果的相对偏差分别为6.86%、7.68%、1.12%、13.10%、11.25%,均小于实验室分析质量控制标准相对偏差允许限25.84%,三种标准物质分析结果的标准推荐值的相对误差为2.3%、1.9%、3.1%,均小于其对应的相对误差允许限14.1%、9.8%、12.4%,数据可靠。检测结果表明,除一个检测点外(011属于Ⅱ类土壤),其他养殖区土壤中的总As含量低于《土壤环境质量标准》(GB 15618—1995)中规定的一级标准中As的最高限值15 mg/kg,属于Ⅰ类土壤,目前环境质量较好,畜禽养殖并未对当地环境造成明显危害。  相似文献   

16.
采用氢氧化钡沉淀–碘量法对高锰酸钾和锰酸钾共存时的含量分别进行测定。向电解液中加入过量的饱和氢氧化钡溶液,利用锰酸钡和高锰酸钡溶度积的不同进行分离,再用碘量法分别对高锰酸钾和锰酸钾进行测定。结果表明,高锰酸钾和锰酸钾的检出限分别为0.061,0.077 g/L,测定结果的相对标准偏差分别为0.57%和0.72%(n=4),高锰酸钾的加标回收率为94.12%~95.85%。t检验结果表明,氢氧化钡沉淀–碘量法与传统方法对高锰酸钾和锰酸钾的测定结果无显著性差异。该法避免了亚铅酸钠和铬盐的毒性及滴定终点颜色不易判断等缺点,适合于高锰酸钾工业生产中主要成分的快速检测。  相似文献   

17.
采用COD消解管和COD消解仪代替标准方法中具塞比色管和高压灭菌器进行消解,调整了取样体积,减少了碱性过硫酸钾加入量和其中氢氧化钠的用量.试验结果表明,改进预处理方法后绘制的标准曲线,相关系数为0.999 5,检出限为0.05 mg/L,相对标准偏差小于5%,样品加标回收率为98.0%~102%.与标准方法相比,改进后的方法精密度和准确度都有一定的提高,并且分析时间缩短,过程得到简化.改进后的方法和标准方法进行t检验比较无明显差异,可满足水中总氮的快速、准确测定.  相似文献   

18.
采用固相萃取(SPE)小柱固相萃取,建立了生活饮用水中2-氯苯酚和2-甲苯酚的气相色谱检测方法。用盐酸调节水样至p H 5.0,用SPE小柱固相萃取后以乙酸乙酯洗脱,以CD-5色谱柱进行分离,氢火焰离子化检测器检测2-氯苯酚和2-甲苯酚的含量。2-氯苯酚和2-甲苯酚的质量浓度在2.00~40.0μg/L范围内与色谱峰面积线性关系良好,检出限分别为0.03,0.04μg/L;加标回收率分别为87.2%~93.9%,89.0%~94.8%;测定结果的相对标准偏差均小于2%(n=7)。该方法具有检出限低、操作简便等优点,适用于生活饮用水中2-氯苯酚和2-甲苯酚的监测分析。  相似文献   

19.
利用同位素稀释-液相色谱-质谱法-(ID-LC-MS/MS)准确测定血清中葡萄糖含量。以[13C6]葡萄糖为内标,用重量法准确地与血清混合,离心沉淀蛋白后在碱性条件下与1.苯基-3-甲基-5-吡唑酮反应,以ZORBAXRX-SIL色谱柱分离,以乙腈-水(体积此25:75)为流动相,使用电喷雾三重四极杆串联质谱多重反应监测模式(MRM)测定,同位素稀释的括号法进行定量。采用美国NIST的血清标准物质SRM965b进行了确证,并用该方法参加JCTLM关于血清中葡萄糖含量的国际比对,测量值与均值的相对偏差分别为1.1%(A样).1.8%(B样),结果在等效范围内。  相似文献   

20.
A method for the analysis of clotrimazole was developed with dispersive liquid–liquid microextraction for sample pre‐concentration and HPLC–MS/MS for analysis. A linear ion trap was used for the confirmation of clotrimazole identity in the samples. The developed method enables the analysis of clotrimazole in river water and sewage effluent from wastewater treatment plants with a LOQ of 0.7 ng/L. Environmental monitoring of clotrimazole was undertaken. Samples from river water and sewage effluents were analysed over a one‐year period. Clotrimazole was found in every tested sample with concentration range from 1 to 31 ng/L. The amount of clotrimazole in tested samples was highly dependent on sampling season. The highest results were obtained in summer and autumn.  相似文献   