首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 33 毫秒
1.
A new sensitive potentiometric surfactant sensor was prepared based on a highly lipophilic 1,3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate antagonist ion. This sensor was used as a sensing material and incorporated into the plasticized PVC-membrane. The sensor responded fast and showed a Nernstian response for investigated surfactant cations: cetylpyridinium chloride (CPC), hexadecyltrimethylammonium bromide (CTAB) and Hyamine with slope 59.8, 58.6 and 56.8 mV/decade, respectively. The sensor served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. Several technical grade cationic surfactants and a few commercial disinfectant products were also titrated, and the results were compared with those obtained from a two-phase standard titration method. The sensor showed satisfactory analytical performances within a pH range of 2-11, and exhibited excellent selectivity performance for CPC compared to all of the organic and inorganic cations investigated. The influence of the nonionic surfactants on the shape of titration curves was negligible if the mass ratio of ethoxylated nonionic surfactants and cationic surfactants (EONS:CS) was not greater than 5.  相似文献   

2.
The construction and characteristic performance of a PVC membrane electrode responsive for sodium dodecylsulfate (SDS) are described in this paper. The electrode based on CTA+DS? ion pair as ionophore in PVC membrane displays a Nernstian slope of ?58.8 ± 0.7 mV/decade in a 1.32 × 10?6 to 3.75 × 10?3 mol L?1 concentration range and a limit of detection of 1.13 × 10?6 mol L?1. The electrode can be used for 3 months without showing significant changes in the value of slope or working range. The electrode has been utilized as an end point indicator electrode for potentiometric titration involving Hyamine as titrant. More than 100 titrations were carried out for the evaluation of the electrode parameters: the standard deviations of the equivalent volume and the equivalent potential, the height of the potential jump and the number of faulty titrations. The behavior of the electrode was assessed with regard to their usefulness in routine analysis.  相似文献   

3.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

4.
《Analytical letters》2012,45(13-14):2791-2802
Abstract

An anionic surfactant ion selective electrode has been developed by coating the Ru?i?ka Selectrode with plasticised polyvinyl chloride containing hyaminedodecylsulfate active substance. The electrode responds to dodecylsulfate, in the range 10?2 ? 10?2 mol dm?3 and has been used for potentiometric titration of micromolar amounts of dodecylsulfate with an accuracy of 0.3%. The influence of several organic and inorganic anions has been investigated.  相似文献   

5.
Current paper‐based potentiometric ion‐sensing platforms are planar devices used for clinically relevant ions. These devices, however, have not been designed for the potentiometric biosensing of proteins or small molecule analytes. A three‐dimensional origami paper‐based device, in which a solid‐contact ion‐selective electrode is integrated with an all‐solid‐state reference electrode, is described for the first time. The device is made by impregnation of paper with appropriate bioreceptors and reporting reagents on different zones. By folding and unfolding the paper structures, versatile potentiometric bioassays can be performed. A USB‐controlled miniaturized electrochemical detector can be used for simple and in situ measurements. Using butyrylcholinesterase as a model enzyme, the device has been successfully applied to the detection of enzyme activities and organophosphate pesticides involved in the enzymatic system as inhibitors. The proposed 3D origami paper device allows the potentiometric biosensing of proteins and small molecules in a simple, portable, and cost‐effective way.  相似文献   

6.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

7.
A potentiometric titration method for the direct determination of anionic polyelectrolytes using a plasticized poly(vinyl chloride) membrane electrode is described. A cationic surfactant solution is used as titrant. The method is based on ion association between the anionic polyelectrolyte in the sample and the cationic surfactant in the titrant. The end-point is detected as a sharp potential change due to an increase in the concentration of the free cationic surfactant at the equivalence point. The sharpness of the titration curve at the end-point is compared for several cationic surfactants; a solution of stearyltrimethylammonium ion has been found to be superior. Received: 8 October 1996 / Revised: 17 December 1996 / Accepted: 18 December 1996  相似文献   

8.
A potentiometric titration method for the direct determination of anionic polyelectrolytes using a plasticized poly(vinyl chloride) membrane electrode is described. A cationic surfactant solution is used as titrant. The method is based on ion association between the anionic polyelectrolyte in the sample and the cationic surfactant in the titrant. The end-point is detected as a sharp potential change due to an increase in the concentration of the free cationic surfactant at the equivalence point. The sharpness of the titration curve at the end-point is compared for several cationic surfactants; a solution of stearyltrimethylammonium ion has been found to be superior. Received: 8 October 1996 / Revised: 17 December 1996 / Accepted: 18 December 1996  相似文献   

9.
A highly selective PVC‐membrane electrode based on 2,6‐diphenylpyrylium fluoroborate is presented. The electrode reveals a Nernstian potentiometric response for sulfate ion over a wide concentration range (5.0 × 10?6‐1.0 × 10?1 M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for sulfate over a wide variety of common organic and inorganic anions and could be used over a wide pH range (2.5–9.5). The detection limit of the sensor is 3.0 × 10?6 M. It was successfully applied to the direct determination of salbutamol, paramomycin tablets, and as an indicator electrode for potentiometric titration of sulfate ions with barium ions.  相似文献   

10.
The first all‐solid‐contact paper‐based single‐use polyion‐sensitive ion‐selective electrodes (ISEs) are described. These polyion‐sensitive ISEs are fabricated using cellulose filter paper coated with a carbon ink conductive layer. A polyanion sensing membrane is cast on a section of the coated paper and the sensor is insulated, resulting in a disposable, single‐use device. Various polyanions are shown to yield large negative potentiometric responses when using these disposable devices for direct polyanion detection. These new sensors are further demonstrated to be useful in indirect polycation detection when polycations (i. e., polyquaterniums (PQs)) are titrated with polyanionic dextran sulfate (DS). Titrations monitored using these paper‐based, all‐solid‐contact devices yield endpoints proportional to the given PQ concentration present in the test sample.  相似文献   

11.
《Electroanalysis》2004,16(12):1009-1013
A novel ion‐selective polymeric membrane sensor based on pyrylium‐4,4‐(1,4‐phenylen) bis[2,6‐bis(2‐naphthyl)]‐bis[tetrafluoroborate] (PBGNB) as an excellent sensing material is successfully developed. The electrode possesses the advantages of a very low detection limit (5.0×10?8 M), a wide working concentration range (1.0×10?8?1.0×10?1 M) and specially, a high sulfate selectivity over most common organic and inorganic anions. The sensor displays Nernstian behavior (slope of 29.5±0.5 mV per decade) in a wide pH range (3.0–8.5). It shows a short response time in the whole concentration range (ca. 10 s). The electrode was used as an indicator electrode in the potentiometric titration of sulfate ions with barium ions. The proposed sensor was successfully applied to the direct determination of salbutamol sulfate and paromomycin sulfate.  相似文献   

12.
《Electroanalysis》2006,18(16):1620-1626
A polyvinylchloride membrane sensor based on N,N′‐bis(salecylidene)‐1,2‐phenylenediamine (salophen) as membrane carrier was prepared and investigated as a Al3+‐selective electrode. The sensor exhibits a Nernstian response toward Al(III) over a wide concentration range (8.0×10?7–3.0×10?2 M), with a detection limit of 6.0×10?7 M. The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 3.2–4.5. The electrode possesses advantages of very fast response and high selectivity for Al3+ in comparison with alkali, alkaline earth and some heavy metal ions. The sensor was used as an indicator electrode, in the potentiometric titration of aluminum ion and in determination of Al3+ contents in drug, water and waste water samples.  相似文献   

13.
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand [2‐mercapto‐5‐(3‐nitrophenyl)‐1,3,4‐thiadiazole] (MNT), self‐assembled to gold nanoparticles (GNP) as suitable carrier for Cd(II) ion with potentiometric method are described. The proposed electrode exhibits a Nernstian slope of 29.4±1.0 mV per decade for Cd(II) ion over a wide concentration range from 3.1×10?8 to 3.1×10?4 mol L?1. The detection limit of electrode was 2.0×10?8 mol L?1 of cadmium ion. The potentiometric responses of electrode based on MNT is independent of the pH of test solution in the pH range 2.0–4.0. It has quick response with response time of about 6 s. The proposed electrode show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrode was successfully employed to detect Cd(II) ion in hair and water samples.  相似文献   

14.
A liquid membrane nonionic surfactant sensitive electrode has been prepared, based on a new barium pseudocationic complex of a highly ethoxylated fatty alcohol polyglycol ether and tetraphenylborate as sensing material. The complex has been incorporated into the plasticized PVC-membrane and used as sensing material.The electrode exhibited positive linear non-Nernstian response toward different nonionic surfactants and sub-Nernstian response toward tetraphenylborate with the lower detection limit of 3.3 × 10−7 mol dm−3 in barium chloride solution.The interfering effect of some alkaline, alkaline earth, and heavy metal cations, has been demonstrated by displaying their calibration curves compared with that of Triton X-100.The electrode has been used as an end-point indicator for potentiometric titration of analytical and technical grade polyethoxylated nonionic surfactants, modelled detergent products, and commercial detergents.  相似文献   

15.
In this work, a highly selective membrane triiodide sensor based on a new charge‐transfer complex of bis(2,4‐dimethoxybenzaldehyde)butane‐2,3‐dihydrazone with iodine (Iodide Charge Transfer complex: ICT) as membrane carrier is introduced. The influences of five different solvent mediators on sensitivity and selectivity of the proposed sensor were considered. The best performance was obtained with the membrane composition containing 30% poly (vinyl chloride), 63% DBP, 5% ICT and 2% HTAB. The electrode shows a Nernstian behavior over a very wide triiodide ion concentration range (1.0 × 10?7‐1.0 × 10?2 M), and a detection limit value of 8.0 × 10?8 M. The effect of pH on the potentiometric response of the sensor was also studied, and it was found that the response of the electrode is independent of the pH of the solution in the pH range of 4.0–10. The proposed sensor has a very fast response time (< 12 s), and good selectivities relative to a wide variety of common inorganic and organic anions, including iodide, acetate, bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, cyanide and thiocyanate. In fact the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for triiodide ion. The proposed membrane sensor can be used for at least 6 months without any divergence in the potentials. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

16.
《Electroanalysis》2003,15(12):1038-1042
A novel gadolinium ion‐selective electrode based on the antibiotic omeprazole as membrane carrier was prepared. The electrode has a linear dynamic range between 1.0×10?1 and 1.0×10?5 M, with a Nernstian slope of 19.3 ± 0.3 mV decade?1 and a detection limit of 5.0×10?6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0–10.0. The electrode possesses the advantages of short conditioning time, fast response time and especially, very good selectivity over a large number of other cations. The electrode can be used for at least 2 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of Gd(III) ions with EDTA.  相似文献   

17.
Ion‐selective electrodes (ISEs) are widely used tools for fast and accurate ion sensing. Herein their design is simplified by embedding a potentiometric cell into paper, complete with an ISE, a reference electrode, and a paper‐based microfluidic sample zone that offer the full function of a conventional ISE setup. The disposable planar paper‐based ion‐sensing platform is suitable for low‐cost point‐of‐care and in‐field testing applications. The design is symmetrical and each interfacial potential within the cell is well defined and reproducible, so that the response of the device can be theoretically predicted. For a demonstration of clinical applications, paper‐based Cl? and K+ sensors are fabricated with highly reproducible and linear responses towards different concentrations of analyte ions in aqueous and biological samples. The single‐use devices can be fabricated by a scalable method, do not need any pretreatment prior to use, and only require a sample volume of 20 μL.  相似文献   

18.
《Analytical letters》2012,45(7-8):807-824
Abstract

A poly(vinyl chloride) membrane ion-selective electrode for the Hyamine 1622 cation is proposed. The active substance of the electrode was the neutral carrier dibenzo-18-crown-6 and di-iso-octylphthalate was used as plasticizer. The electrode had a Nernstian behaviour between 6.0 × 10?6 and 1.6 × 10?3 mol/dm3, a pH working range of 2 – 12 and high selectivity towards inorganic cations. Among the organic cations tested, only those having surfactant properties did interface. The electrode was suitable for determining the critical micelle concentration and as end-point detector in the potentiometric titration of the cationic surfactants.  相似文献   

19.
Summary Several quaternary ammonium halides have been evaluated for the precipitation titration of anionic surfactants and soaps. The titrants were hexadecyltrimethylammonium chloride and bromide, hexadecylpyridinium chloride, and diisobutylphenoxyethoxyethyl(dimethyl)benzylammonium chloride. Hexadecylpyridinium chloride yielded the highest precision and largest potentiometric break. Titrations were monitored with a commercically available fluoroborate ion-selective indicator electrode and a double-junction reference electrode. Commercially available perchlorate, nitrate, and calcium electrodes may also be used for emf monitoring. This obviates the need of preparing special liquid membrane or other electrodes mostly used heretofore in the potentiometric titration of surfactants and soaps. Electrophoresis purity reagent sodium dodecylsulfate is recommended for the standardization of the quaternary ammonium halides. The reverse titration, of cationic surfactants vs. standard sodium dodecylsulfate, is similarly feasible.Work performed under the auspices of the U.S. Department of Energy by the Lawrence Livermore Laboratory under contract number W-7405-ENG-48.  相似文献   

20.
《Electroanalysis》2002,14(24):1691-1698
Three different recently synthesized aza‐thioether crowns containing a 1,10‐phenanthroline sub‐unit (L1–L3) and a corresponding acyclic ligand (L4) were studied to characterize their abilities as silver ion ionophores in PVC‐membrane electrodes. Novel conventional silver‐selective electrodes with internal reference solution (CONISE) and coated graphite‐solid contact electrodes (SCISE) were prepared based on one of the 15‐membered crowns containing two donating S atoms and two phenanthroline‐N atoms (L1). The electrodes reveal a Nernstian behavior over wide Ag+ ion concentration ranges (1.0×10?5?1.0×10?1 M for CONISE and 5.0×10?8?4.0×10?2 M for SCISE) and very low limits of detection (8.0×10?6 M for CONISE and 3.0×10?8 M for SCISE). The potentiometric response is independent from pH of the solution in the pH range 3.0–8.0. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations. The electrodes can be used for at least 2 months (for CONISE) and 4 months for (SCISE) without any appreciable divergence in potentials. The electrodes were used as an indicator electrode in the potentiometric titration of Ag+ ion and in the determination of silver in photographic emulsions and in radiographic and photographic films.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号