首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
李佳晨  曹玲  方方  施海蔚  黄青  谭力  段巧莲  冯有龙 《色谱》2022,40(12):1136-1142
脂溶性维生素作为保健食品重要的功效指标,现有的标准方法存在测定组分少、样品前处理过程复杂、对人员操作能力要求较高等问题,因此建立一种快速、简便、准确,且能同时检测多种常见脂溶性维生素的方法具有重要的现实意义。该研究采用超高效合相色谱(UPC2)建立了同时测定保健食品中维生素A棕榈酸酯、维生素A醋酸酯、维生素E醋酸酯、维生素K1α-生育酚、β-生育酚、γ-生育酚、δ-生育酚、维生素D2、维生素D3等10种常用脂溶性维生素的方法。样品经含75%二甲基亚砜(DMSO)的水溶液在45 ℃水浴超声15 min破乳,再加入正己烷振摇提取90 min, 3000 r/min离心10 min,取上清液过滤后进行分析。使用LC-Simulator软件对色谱条件进行模拟及优化,选用ACQUITY UPC2 Viridis HSS C18 SB色谱柱进行分离,CO2和乙腈-甲醇(85∶15, v/v)为流动相,梯度洗脱,流速1.9 mL/min,柱温30 ℃,选取10种脂溶性维生素各自的最大吸收波长检测,外标法进行定量。结果表明,10种脂溶性维生素在各自范围内线性关系良好,相关系数(r)均大于0.9997,检出限(LOD)和定量限(LOQ)分别为片剂:0.2~30 μg/g和0.8~75 μg/g,胶囊:0.4~60 μg/g和2~150 μg/g,样品平均加标回收率在96.5%~113.9%之间,RSD均小于4%,精密度、稳定性、重复性测定结果的RSD值也均小于2%。经比较,该方法测定结果与现有的国家食品安全标准基本一致,但该方法简单、快速、灵敏、准确,可满足保健食品中10种脂溶性维生素的检测要求,为保健食品中脂溶性维生素的快速同时检测奠定基础。  相似文献   

2.
Chromatographic methods for the determination of water- and fat-soluble vitamins in foods are reviewed. For each vitamin, sample preparation, detection problems and chromatographic conditions are presented and discussed. High-performance liquid chromatography (HPLC) is becoming a standard method in vitamin assay, especially for routine work. HPLC systems can be automated using in-line solid-phase extraction and column switchings, resulting in very sensitive methods, even when simple UV detection is employed.  相似文献   

3.
4.
Summary An HPLC method has been developed for the determination of fat-soluble vitamins. Ten fat-soluble vitamins were separated simultaneously on a 25 cm×4.6 mm i.d. Hypersil C18 column with acetonitrile-dichloromethane-methanol, 60:20:20 (v/v) as mobile phase at 1.0 mL min−1 with wavelength-programmed ultraviolet-visible-absorbance detection. Total analysis time was 12 min. The limits of detection were 0.03, 0.01, 0.55, 1.84, 0.02, 0.02, 0.01, 0.16, 0.33, 0.01, and 0.01 ng mL−1 for retinol, retinyl acetate, retinyl palmitate, β-carotene, ergocalciferol, cholecalciferol, tocopherol, tocopherol acetate, phylloquinone, menatetrenone, and menadione, respectively. Analysis of human serum 2–7 days after ingestion of oral vitamins and Chinese herbs led to the conclusion that the concentration of vitamins was higher than for control serum.  相似文献   

5.
A rapid, reliable and reproducible method based on microemulsion electrokinetic chromatography (MEEKC) for simultaneous determination of 13 kinds of water- and fat-soluble vitamins has been developed in this work. A novel microemulsion system consisting of 1.2% (w/w) sodium lauryl sulphate (SDS), 21% (v/v) 1-butanol, 18% (v/v) acetonitrile, 0.8% (w/w) n-hexane, 20mM borax buffer (pH 8.7) was applied to improve selectivity and efficiency, as well as shorten analysis time. The composition of microemulsion used as the MEEKC running buffer was investigated thoroughly to obtain stable separation medium, as well as the optimum determination conditions. Acetonitrile as the organic solvent modifier, pH of the running buffer and 1-butanol as the co-surfactant played the most important roles for the separation of the fat-soluble vitamins, water-soluble vitamins and stabilization of system, respectively. The 13 water- and fat-soluble vitamins were baseline separated within 30 min. The system was applied to determine water- and fat-soluble vitamins in commercial multivitamin pharmaceutical formulation, good accuracy and precision were obtained with recoveries between 97% and 105%, relative standard derivations (RSDs) less than 1.8% except vitamin C, and acceptable quantitative results corresponding to label claim.  相似文献   

6.
A high-performance liquid chromatographic electrochemical detection for the rapid and simultaneous determination of the vitamin A, D3 and E is described. The separation is carried out by using a C18 reversed-phase column and 0.1 M LiClO4 in methanol-water (99:1, v/v) as the mobile phase. The compounds are eluted with good resolution in the above order within about 15 min and are determined by amperometric detection with a glassy carbon electrode at +1050 mV (vs. Ag/AgCl). The method gave reproducible results and the detection limits were of the order of 0.07, 4 and 0.2 ng of vitamin A, D3 and E, respectively. The method was successfully applied to the determination of vitamin A, D3 and E in liquid cow milk and milk powder samples. After saponification, fat-soluble vitamins were extracted with hexane and a methanolic solution of the dried extract was injected directly into the chromatographic system, avoiding the clean-up step that is necessary for vitamin D3 when electrochemical detection is not used. Good recoveries were obtained.  相似文献   

7.
A semi-automatic procedure for the continuous clean-up and concentration of several fat-soluble vitamins prior to their separation by HPLC and UV detection is reported. The procedure is based on the use of a minicolumn packed with aminopropylsilica as sorbent located prior to the chromatographic detection system. The overall process was developed and applied to the main liposoluble vitamins (A, D2, D3, E, K1, K3) and several hydroxy metabolites of vitamin D3 [25-(OH)-D3,24,25-(OH)2-D3 and 1,25-(OH)2-D3]. All the analytes were monitored at a compromise wavelength of 270 nm. Calibration graphs were constructed between 0.01 and 100 ng ml-1 for vitamin D2 and D3 and their hydroxy metabolites, between 0.1 and 100 ng ml-1 for vitamin A, K1 and K3 and between 1 and 100 ng ml-1 for vitamin E, with excellent regression coefficients (> or = 0.9901) in all cases. The precision was established at two concentration levels with acceptable RSDs in all instances (between 3.6 and 8.7%). The method was appropriate for the determination of vitamin D2, D3, K1 and K3 and the 24,25-dihydroxy and 25-hydroxy metabolites of vitamin D3 in human plasma. The method was applied to plasma samples spiked with the target analytes and the recoveries ranged between 78 and 109%.  相似文献   

8.
Pellerin F  Dumitrescu D 《Talanta》1980,27(3):243-251
The separation, identification and determination of the fat- and water-soluble vitamins are realized by partition chromatography with a reversed-phase system made by bonding a C(18) group to silica. The water-soluble vitamins are directly separated with the mobile phase 1% acetic acid/acetonitrile (89:11 v/v) and are revealed by an ultraviolet detector, except for pantothenic acid. The separation efficiency and precision of determination of the fat-soluble vitamins depend on the operational conditions. The composition of the excipients and all the constituents of pharmaceuticals (aqueous and oil solutions, injections, dispersions, emulsions) determine the choice of the extraction solvents and the preparation of the solution to be injected; the polarity of the mobile phase (acetonitrile/water 95:5 v/v) can be changed, and the choice depends on the components to be separated. The experimental conditions are specified and some examples are given of application of HPLC to determination of water-soluble vitamins (B1, B2, C, PP, B6) and fat-soluble vitamins (non-saponifiable oils, vitamin A and its esters, cholecalciferol, ergocalciferol, and tocopherol and its acetate) in multivitamin formulations (solutions, suspensions, syrups, fatty excipients etc.).  相似文献   

9.
A new procedure was developed for the simultaneous determination of water- and fat-soluble vitamins by microemulsion electrokinetic chromatography. Using microemulsions based on sodium dodecyl sulfate, Brij 35, 1-butanol, and heptane, 10 vitamins were separated (4 water-soluble and 6 fat-soluble) within 35 min. The efficiency of the separation was 800000 theoretical plates (effective capillary length, 40 cm). To enhance the selectivity, 2-propanol was used as a hydrophobizing addition into the microemulsion. The procedure was used for analyzing a kaolin-based vitamin premix. The use of microemulsion as an agent for extracting vitamins from the support considerably simplifies the sample preparation.  相似文献   

10.
建立了同时测定秋葵干蔬中脂溶性维生素A、E、K3的反相高效液相色谱法.样品皂化后,采用C18色谱柱(150 mm×4.6 mm,5μm i.d.)进行分离,以甲醇为流动相,流速1.0 mL/min,二极管阵列检测器(DAD)在325、290、244 nm波长下同时检测,外标法定量.结果表明,脂溶性维生素A、E、K3在0...  相似文献   

11.
A simple and reliable reversed-phase high-performance liquid chromatographic (HPLC) method for the routine determination of vitamins A and E and beta-carotene in plasma (or serum) with wavelength-programmed ultraviolet-visible absorbance detection is described. A 200-microliters aliquot of serum or plasma sample, after deproteinization with ethanol, and containing tocopherol acetate as internal standard, was extracted with butanol-ethyl acetate. Sodium sulphate was added for dehydration. Analytes of extracted samples were found to be stable for at least four days. A 10-microliters aliquot of this organic extract was used for HPLC analysis. The mobile phase was methanol-butanol-water (89.5:5:5.5, v/v) and the flow-rate was set at 1.5 ml/min. The analytes of interest were well separated from other plasma constituents within 22 min at 45 degrees C. The lowest detection limits of vitamins A and E and beta-carotene were 0.02, 0.5 and 0.1 microgram/ml, respectively. The recovery and reproducibility of the present method were around 90%. The method is sensitive, specific and can be used for epidemiological studies and for routine determination of vitamin deficiency. Several important factors that may affect the analysis are also discussed in this paper.  相似文献   

12.
Particle beam (PB) high performance liquid chromatography (HPLC)-mass spectrometry (MS) has been studied to investigate its suitability for the analysis of fat-soluble vitamins, as an example of thermally labile substances. The PB LC-MS system has been used to detect and identify vitamins A, D and E in foods and multi-vitamin preparations. The qualitative performance of the PB interface has been evaluated by an examination of the working parameters. A rapid elution of the vitamins was obtained on a C8 reversed-phase column using an aqueous methanol mobile phase. Analyses have been carried out using both, electron (EI) and chemical (CI) ionization. Positive and negative-ion CI spectra of the compounds are discussed. When PB-MS conditions are optimized, the detection limits for the fat-soluble vitamins tested have been typically in the 0.6–25 ng range when using the selected-ion monitoring technique.  相似文献   

13.
An HPLC method utilizing a UV and a fluorimetric detector linked in series is described. By use of a simple integrator-controlled time-switched relay, analysis of serum vitamin A and E is accomplished on the same chromatogram and at optimum sensitivity for each detector. A single internal standard (retinyl acetate) monitored only by the UV detector permits measurement of both vitamins over a wide linear range. Precision of the assays is satisfactory, both on a within-day and on a day-to-day basis. Recoveries of both vitamins are virtually 100% whilst sensitivity is 2 μg/L (retinol) and 0.05 mg/L (α-tocopherol).  相似文献   

14.
Fat-soluble vitamins (FSVs) include vitamin A, carotenoids, vitamins D, E, and K. New legislation is being introduced in many countries to reinforce regulatory compliance of declared concentrations of vitamins and other micronutrients in food products and dietary supplements. The levels of FSVs are likely to be more closely scrutinized due to their potential health risks associated with overdosing, in particular of vitamin D. However, a proviso of stricter regulatory compliance is that analytical methods must be fit-for-purpose, providing adequate accuracy and precision. Official methods have been published by organizations such as AOAC INTERNATIONAL, European Committee for Standardization, International Dairy Federation, U.S. Pharmacopeia, and International Organization for Standardization. The methods available for foods, dietary supplements, and vitamin premixes are evaluated in this review. In general, these methods show adequate precision for regulatory compliance; however, the field of application has not often been evaluated for a sufficiently large range of food matrixes. Gaps have been noted in the range of published official procedures, particularly for carotenoids and vitamin premixes. The potential of some recent developments in sample preparation and chromatographic techniques were evaluated to provide improved procedures for FSV analysis the future.  相似文献   

15.
Separation and determination of water- and fat-soluble vitamins by micellar (MEKC) and microemulsion electrokinetic chromatography (MEEKC) are compared. MEKC is only useful in the quantitative analysis of water-soluble vitamins when sodium dodecylsulfate (SDS) is used as the surfactant. However, the separation of mixtures containing water- and fat-soluble vitamins is only achieved by MEEKC using a microemulsion prepared by mixing SDS as the surfactant, butanol as the co-surfactant, octane as the non-polar modifier and propanol as the second co-surfactant. The injection time and the solvent used for the dilution of samples have a significant effect on the analysis of lypophilic compounds. The most reproducible results in the analysis of fat-soluble vitamins are obtained by using the same microemulsion electrolyte as the solvent for samples and an injection time of 10 s.  相似文献   

16.
A rapid method was developed to determine both types of vitamins in Rhodiola imbricata root for the accurate quantification of free vitamin forms. Rapid resolution liquid chromatography/tandem mass spectrometry (RRLC–MS/MS) with electrospray ionization (ESI) source operating in multiple reactions monitoring (MRM) mode was optimized for the sequential analysis of nine water-soluble vitamins (B1, B2, two B3 vitamins, B5, B6, B7, B9, and B12) and six fat-soluble vitamins (A, E, D2, D3, K1, and K2). Both types of vitamins were separated by ion-suppression reversed-phase liquid chromatography with gradient elution within 30 min and detected in positive ion mode. Deviations in the intra- and inter-day precision were always below 0.6% and 0.3% for recoveries and retention time. Intra- and inter-day relative standard deviation (RSD) values of retention time for water- and fat-soluble vitamin were ranged between 0.02–0.20% and 0.01–0.15%, respectively. The mean recoveries were ranged between 88.95 and 107.07%. Sensitivity and specificity of this method allowed the limits of detection (LOD) and limits of quantitation (LOQ) of the analytes at ppb levels. The linear range was achieved for fat- and water-soluble vitamins at 100–1000 ppb and 10–100 ppb. Vitamin B-complex and vitamin E were detected as the principle vitamins in the root of this adaptogen which would be of great interest to develop novel foods from the Indian trans-Himalaya.  相似文献   

17.
Several methods for the separation of vitamins on HPLC columns were already validated in the last 20 years. However, most of the techniques focus on separating either fat- or water-soluble vitamins and only few methods are intended to separate lipophilic and hydrophilic vitamins simultaneously. A mixed-mode reversed-phase weak anion exchange (RP-WAX) stationary phase was developed in our laboratory in order to address such mixture of analytes with different chemical characteristics, which are difficult to separate on standard columns. The high versatility in usage of the RP-WAX chromatographic material allowed a baseline separation of ten vitamins within a single run, seven water-soluble and three fat-soluble, using three different chromatographic modes: some positively charged vitamins are eluted in ion exclusion and ion repulsion modes whereas the negatively charged molecules are eluted in the ion exchange mechanism. The non-charged molecules are eluted in a classical reversed-phase mode, regarding their polarities. The method was validated for the vitamin analysis in tablets, evaluating selectivity, robustness, linearity, accuracy, and precision. The validated method was finally employed for the analysis of the vitamin content of some commercially available supplement tablets.  相似文献   

18.
A bottleneck in crosstalk and QC research has been the quantification of diverse chemotypes in small amounts of tissue. An LC-UV method for estimating 28 selected metabolites of the regulatory network underlying growth, development, maintenance, vital functions, defense reactions, and food quality is reported. The method was based on binary gradient resolutions of the analytes in an RP C18 column. The mobile phase comprised solvent A [water+0.1% trifluoroacetic acid (TFA)] and B (acetonitrile + 0.085% TFA at a flow rate of 1 ml/min. Twenty-three metabolites (selected amino acids, coenzymes, growth regulators, phenolic antioxidant, and water-soluble vitamins) were detected at 254 nm, and four fat-soluble vitamins at 280 nm. Jasmonic acid was quantified at 210 nm. The RSDs of peak area and retention time for each metabolite were <5.8%. The calibration graphs were linear with R2 values ranging from 0.98 to 0.99. The LODs (microg/mL) were about 0.01-1.0 for 23 metabolites quantified at 254 nm, 0.1-0.2 for fat-soluble vitamins, and 0.1 for jasmonic acid. The recoveries ranged from 80 to 105%, with RSDs of 2.8 to 11.2%. The method has been satisfactorily applied for determination of 28 metabolites from Cicer arietinum (L.) and Solanum lycopersicum (L.). It could be an alternative and competitive method of choice that can cheaply and easily perform routine analysis for food quality and targeted metabolomics of chickpea and tomato in response to stressors.  相似文献   

19.
Summary A combined system of pressure-programmed packed capillary supercritical fluid chromatography-mass spectrometry (SFC/MS) was constructed using a self-soupting interface assisted by vacuum nebulizing. For the optimum operation of the SFC/MS system, fundamental analytical conditions such as the flow rate of the mobile phase, the pump pressure and the composition of the mobile phase were examined. The use of large packing materials indicated that the capacity factor for a sample solute is almost constant under a given pump pressure regardless of the flow rate of the supercritical fluid. The SFC/MS system was applied to the analysis of both water- and fat-soluble vitamins. Both types vitamins were clearly separated under basically the same SFC conditions. High quality mass spectra of the vitamins were obtained; selected ion monitoring (SIM) traces of the vitamins are also reported as well as their UV traces.  相似文献   

20.
A rapid, simple, and accurate ion-pair RPLC method has been developed for simultaneous analysis of vitamin C and major B-complex vitamins. An RP C18 column thermostated at 30 degrees C was used with gradient elution of mobile phase comprising 10 mM potassium dihydrogen phosphate buffer (containing 3 mM sodium hexane-1-sulfonate, adjusted to pH 2.80 with o-phosphoric acid) and methanol at a flow rate of 1.0 mL/min to achieve the best possible separation and resolution of all vitamins in about 11.00 min. The detection was performed at 274 nm. The method has been implemented successfully for simultaneous determination of vitamins present in 12 multivitamin/multimineral pharmaceutical preparations, as well as in human urine. Typical validation characteristics were evaluated in accordance with International Conference on Harmonization guidelines. Good linearity over the investigated concentration levels was observed. Intraday repeatability was < or = 2.0%, and interday variation was < or = 2.6%, for all vitamins. The method can be used for assay of these vitamins over a wide concentration range with good precision and accuracy; hence, it would be appropriate for routine QC as well as in clinical analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号