首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Micellar affinity gradient focusing (MAGF) is a microfluidic counterflow gradient focusing technique that combines the favorable features of MEKC and temperature gradient focusing. MAGF separates analytes on the basis of a combination of electrophoretic mobility and partitioning with the micellar phase. A temperature gradient is produced along the separation channel containing an analyte/micellar system to create a gradient in interaction strength (retention factor) between the analytes and micelles. Combined with a bulk counterflow, species concentrate at a unique point where their total velocity sums to zero. MAGF can be used in scanning mode by varying the bulk flow so that a large number of analytes can be sequentially focused and passed by a single detection point. In this work, we develop a bilinear temperature gradient along the separation channel that improves separation performance over the conventional linear designs. The temperature profile along the channel consists of a very sharp gradient used to preconcentrate the sample followed by a shallow gradient that increases resolution. We fabricated a hybrid PDMS/glass microfluidic chip with integrated micro heaters that generate the bilinear profile. Performance is characterized by separating several different samples including fluorescent dyes using SDS surfactant and pI markers using both SDS and poly-SUS surfactants as the micellar phase. The new design shows a nearly two times improvement in peak capacity and resolution in comparison to the standard linear temperature gradient.  相似文献   

2.
This report describes a new method for the concentration and separation of neutral and/or hydrophobic analytes based on a combination of the analytes' electrophoretic mobility, and affinity for partitioning into a micellar phase. Micellar affinity gradient focusing (MAGF) works by creating a gradient in the micellar retention factor. An electric field is applied along the channel to cause the (negatively charged) micelles to move from the region of high retention to the region of low retention, and the mobile phase is forced to move from the region of low retention to the region of high retention. Consequently, the analyte moves into the gradient region from both directions where it is concentrated at a point where its total velocity is zero. Different analytes, which interact differently with the micelles, will have zero total velocity at different points along the gradient, and will thereby be simultaneously concentrated and separated.  相似文献   

3.
A microchannel device is presented which separates and focuses charged proteins based on electric field gradient focusing. Separation is achieved by setting a constant electroosmotic flow velocity against step changes in electrophoretic velocity. Where these two velocities are balanced for a given analyte, the analyte focuses at that point because it is driven to it from all points within the channel. We demonstrate the separation and focusing of a binary mixture of bovine serum albumin and phycoerythrin. The device is constructed of intersecting microchannels in poly(dimethylsiloxane)(PDMS) inlaid with hollow dialysis fibers. The device uses no exotic chemicals such as antibodies or synthetic ampholytes, but operates instead by purely physical means involving the independent manipulation of electrophoretic and electroosmotic velocities. One important difference between this apparatus and most other devices designed for field-gradient focusing is the injection of current at discrete intersections in the channel rather than continuously along the length of a membrane-bound separation channel.  相似文献   

4.
5.
6.
We report on capillary isoelectric focusing-mass spectrometry (CIEF-MS) of complex peptide mixtures in the absence of carrier ampholytes. Furthermore, the use of low concentrations of carrier ampholytes as mere spacers is investigated. Carrier ampholytes are complex mixtures of amphoteric compounds with high buffering capacity. Since all peptides are amphoteric compounds by themselves, the use of carrier ampholytes may be superfluous to establish a stable pH gradient in CIEF analysis of protein digests. Our research showed that when carrier ampholytes are omitted, the analyte ions are not focused at their isoelectric point. The analytes are charged, leading to electrophoretic mobility uncharacteristic for CIEF. The method was tested for a five-protein-mixture at 0.02 mg/mL per protein and 0.05 mg/mL per protein. At the lower concentration, the analytes were stacked during the focusing process in only a limited length of the capillary. Therefore, the higher concentration led to better separation efficiency. It was found that at low concentration (0.20%) the carrier ampholytes could work as spacers. Though it led to sensitivity losses of 15-45%, this was compensated by the higher separation efficiencies seen. The method was evaluated with an eight-protein-mixture, of which all could be identified after performing MS/MS.  相似文献   

7.
Li Y  DeVoe DL  Lee CS 《Electrophoresis》2003,24(1-2):193-199
Isoelectric focusing (IEF) separations, in general, involve the use of the entire channel filled with a solution mixture containing protein/peptide analytes and carrier ampholytes for the creation of a pH gradient. Thus, the preparative capabilities of IEF are inherently greater than most microfluidics-based electrokinetic separation techniques. To further increase sample loading and therefore the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from solution reservoirs, is demonstrated in this study. The proteins/peptides continuously migrate into the plastic microchannel and encounter a pH gradient established by carrier ampholytes originally present in the channel for focusing and separation. Dynamic sample introduction and analyte focusing in plastic microfluidic devices can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Under the influence of 30 min electrokinetic injection at constant electric field strength of 500 V/cm, the sample loading is enhanced by approximately 10-100 fold in comparison with conventional IEF.  相似文献   

8.
Analytical equilibrium gradient methods are non-linear separation methods in which the separation mechanism involves a force gradient along the separation channel. These methods can be classified into two categories: those in which the gradient is a field gradient applied along the separation channel (i.e., field gradient), and those in which the channel is subjected to a constant field with a gradient formed in some other property (i.e., constant field). Standard deviation of peak width, resolution and peak capacity are important parameters in characterizing equilibrium gradient methods, and general expressions can be obtained from considering both the point of force acting on the analyte and the basic flux equation. Several successful examples, such as density gradient sedimentation, isoelectric focusing and electromobility focusing are discussed. Based on equilibrium gradient methods in the field gradient category, a method to dynamically improve peak capacity is described. An example of such an approach is given using electromobility focusing.  相似文献   

9.
Electric field gradient focusing   总被引:1,自引:0,他引:1  
Electric field gradient focusing (EFGF) is a relatively new separation technique with promising attributes, particularly for protein analysis. The fundamental fractionation mechanism in EFGF involves a gradient in electric field along the length of a separation column. The electrophoretic force that drives charged analytes in a region of changing electric field is opposed by a constant, pressure-driven bulk fluid flow. When the electrophoretic velocity of a particular moiety is equal and opposite to the velocity of the fluid flow, the analyte focuses into a stationary band. Thus, EFGF can both concentrate and separate charged species according to electrophoretic mobility. To date, the electric field gradients needed for EFGF have been established using a number of different approaches, including channels having changing cross-sectional areas, conductivity gradients caused by the diffusion of buffer ions across a membrane, electrode arrays, and temperature gradients in buffers whose conductivities change as a function of temperature. EFGF has proven particularly effective for sample enrichment, with concentration factors of 10,000 reported. In this article we review advances in EFGF technology and discuss prospects for further improving EFGF for chemical analysis.  相似文献   

10.
Mohan D  Lee CS 《Electrophoresis》2002,23(18):3160-3167
A microdialysis junction is employed as the interface for on-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis in a two-dimensional separation system. Capillary isoelectric focusing not only provides high-resolution separation of tryptic peptides based on their differences in isoelectric point, but also potentially allows the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. Carrier ampholytes, employed for the creation of a pH gradient during focusing, are further utilized as the leading electrolyte in the second separation dimension, transient isotachophoresis-zone electrophoresis. Many peptides which have the same isoelectric point would most likely have different charge-to-mass ratios, and thus different electrophoretic mobilities in zone electrophoresis. Two-dimensional separation of proteolytic peptides is demonstrated using standard proteins, including cytochrome c, ribonuclease A, and carbonic anhydrase II. The maximum peak capacity is estimated to be around approximately 1600 and can be significantly increased by simply increasing the capillary column length and manipulating the range of pH gradient in isoelectric focusing. In addition to enhanced separation efficiency and resolution, this two-dimensional electrokinetic separation system permits sensitive and comprehensive analysis of peptide fragments, especially when integrated with electrospray ionization mass spectrometry for peptide/protein identification.  相似文献   

11.
Shave E  Vigh G 《Electrophoresis》2004,25(2):381-387
In order to improve the production rates and lower the specific electrophoretic energy consumption values in preparative-scale, recirculating, binary isoelectric trapping separations, we propose to add an auxiliary isoelectric agent to the solution in the anodic separation compartment and another to the solution in the cathodic separation compartment to implement pH-biased isoelectric trapping. The auxiliary isoelectric agents are selected such that they are trapped in the respective anodic and cathodic separation compartments and also, have isoelectric point (pI) values that are different from the pI values of the analytes of interest. By proper selection of the auxiliary isoelectric agents and their concentrations, the analytes of interest can be kept in nonisoelectric, charged state during the entire course of the preparative-scale, recirculating, binary isoelectric trapping separation. This results in higher electrophoretic mobilities and solubilities for the analytes than in their isoelectric or near-isoelectric states, and leads to faster binary isoelectric trapping separations.  相似文献   

12.
On-line capillary isotachophoresis (cITP)-NMR experiments were used to probe the interactions of the pharmaceutical compounds S-alprenolol, S-atenolol, R-propranolol, R-salbutamol and S-terbutaline with beta-cyclodextrin (beta-CD) during cITP concentration. In cITP, ionic analytes are concentrated and separated on the basis of their electrophoretic mobility. Because neutral molecules have an electrophoretic mobility of zero, they are normally not concentrated or separated in electrophoretic experiments like cITP. Most of the analytes studied were concentrated by cITP sample stacking by a factor of around 300. For analytes that formed a strong inclusion complex, beta-CD co-concentrated during cITP sample stacking. However, once the focusing process was complete, a discrete diffusional boundary formed between the cITP-focused analyte band and the leading and trailing electrolyte, which restricted diffusion into and out of the analyte band.  相似文献   

13.
Lin H  Shackman JG  Ross D 《Lab on a chip》2008,8(6):969-978
Temperature gradient focusing (TGF) is a new and promising equilibrium gradient focusing method which can provide high concentration factors for improved detection limits in combination with high-resolution separation. In this technique, temperature-dependent buffer chemistry is employed to generate a gradient in the analyte electrophoretic velocity. By the application of a convective counter-flow, a zero-velocity point is created within a microchannel, at which location the ionic analytes accumulate or focus. In general, the analyte concentration is small when compared with buffer ion concentrations, such that the focusing mechanism works in the ideal, linearized regime. However, this presumption may at times be violated due to significant sample concentration growth or the use of a low-concentration buffer. Under these situations the sample concentration becomes non-negligible and can induce strong nonlinear interactions with buffer ions, which eventually lead to peak shifting and distortion, and the loss of detectability and resolution. In this work we combine theory, simulation, and experimental data to present a detailed study on nonlinear sample-buffer interactions in TGF. One of the key results is the derivation of a generalized Kohlrausch regulating function (KRF) that is valid for systems in which the electrophoretic mobilities are not constant but vary spatially. This generalized KRF greatly facilitates analysis, allowing reduction of the problem to a single equation describing sample concentration evolution, and is applicable to other problems with heterogeneous electrophoretic mobilities. Using this sample evolution equation we have derived an understanding of the nonlinear peak deformation phenomenon observed experimentally in TGF. We have used numerical simulations to validate our theory and to quantitatively predict TGF. Our simulation results demonstrate excellent agreement with experimental data, and also indicate that the proper inclusion of Taylor dispersion is important for the accurate modeling of TGF. This work is an important first step towards the understanding and prediction of the more complex, nonlinear, and multi-species interactions which often occur in on-chip electrophoretic assays such as TGF.  相似文献   

14.
The impact of initial sample distribution on separation and focusing of analytes in a pH 3–11 gradient formed by 101 biprotic carrier ampholytes under concomitant electroosmotic displacement was studied by dynamic high-resolution computer simulation. Data obtained with application of the analytes mixed with the carrier ampholytes (as is customarily done), as a short zone within the initial carrier ampholyte zone, sandwiched between zones of carrier ampholytes, or introduced before or after the initial carrier ampholyte zone were compared. With sampling as a short zone within or adjacent to the carrier ampholytes, separation and focusing of analytes is shown to proceed as a cationic, anionic, or mixed process and separation of the analytes is predicted to be much faster than the separation of the carrier components. Thus, after the initial separation, analytes continue to separate and eventually reach their focusing locations. This is different to the double-peak approach to equilibrium that takes place when analytes and carrier ampholytes are applied as a homogenous mixture. Simulation data reveal that sample application between two zones of carrier ampholytes results in the formation of a pH gradient disturbance as the concentration of the carrier ampholytes within the fluid element initially occupied by the sample will be lower compared to the other parts of the gradient. As a consequence thereof, the properties of this region are sample matrix dependent, the pH gradient is flatter, and the region is likely to represent a conductance gap (hot spot). Simulation data suggest that sample placed at the anodic side or at the anodic end of the initial carrier ampholyte zone are the favorable configurations for capillary isoelectric focusing with electroosmotic zone mobilization.  相似文献   

15.
Matsui T  Franzke J  Manz A  Janasek D 《Electrophoresis》2007,28(24):4606-4611
This paper reports the application of temperature gradient focusing (TGF) in a PDMS/glass hybrid microfluidic chip. With TGF, by the combination of a temperature gradient along a microchannel, an applied electric field, and a buffer with a temperature-dependent ionic strength, analytes are focused by balancing their electrophoretic velocities against the bulk velocity of the buffer containing the analytes. In this work, Oregon Green 488 carboxylic acid was concentrated approximately 30 times as high as the initial concentration in 45 s at moderate electric strength of 70 V/cm and a temperature gradient of 55 degrees C across the PDMS/glass hybrid microfluidic chip with a 1 cm long capillary.  相似文献   

16.
Two types of DNA hybridization assays are demonstrated with temperature gradient focusing (TGF) and peptide nucleic acids (PNAs). In TGF, the application of a controlled temperature gradient along the length of a microchannel filled with an appropriate temperature-dependent buffer results in the formation of a gradient in both the electric field and electrophoretic velocity. Ionic species move in this gradient and concentrate at a unique point where the total velocity sums to zero. The first assay is a mixing assay in which PNA is allowed to flow through spatially focused DNA targets within a capillary. The second assay detects single base pair mutations (SBPM) by monitoring the fluorescence intensity of PNA/DNA duplexes as a function of temperature within the capillary. The SBPM analysis can be performed in less than 5 min with 100-fold more dilute analyte compared to conventional UV melting measurements.  相似文献   

17.
An improved preparative method based on isoelectric focusing of analytes in a cellulose‐based separation medium is described in this study. Cellulose is suspended in an aqueous solution of simple buffers, ethylene glycol, glycerol, nonionic surfactant, and colored pI markers. Water partially evaporates during focusing run and the separation takes place in an in situ generated layer of cellulose, which has a gel‐like appearance at the end of analysis. Final positions of analytes are indicated by the positions of zones of focused pI markers. Fractions, segments of the separation medium with analytes, can be simply collected by spatula and analyzed by downstream analytical methods. Good focusing ability of the new method and almost quantitative recovery of model proteins, cytochrome c and bovine serum albumin, was verified by gel electrophoresis and capillary isoelectric focusing of the collected fractions.  相似文献   

18.
Electromobility focusing (EMF) is a relatively new protein separation technique that utilizes an electric field gradient and a hydrodynamic flow. Proteins are focused in order of electrophoretic mobility at points where their electrophoretic migration velocities balance the hydrodynamic flow velocity. Steady state bands are formed along the separation channel when equilibrium is reached. Further separation and detection can be easily achieved by changing the electric field profile. In this paper. we describe an EMF system with on-line UV absorption detection in which the electric field gradient was formed using a dialysis hollow fiber. Protein focusing and preconcentration were performed with this system. Voltage-controlled separation was demonstrated using bovine serum albumin and myoglobin as model proteins. The limitations of the current method are discussed, and possible solutions are proposed.  相似文献   

19.
Isoelectric focusing plays a critical role in the analysis of complex protein samples. Conventionally, isoelectric focusing is implemented with carrier ampholytes in capillary or immobilized pH gradient gel. In this study, we successfully exhibited a carrier ampholyte‐free isoelectric focusing on paper‐based analytical device. Proof of the concept was visually demonstrated with color model proteins. Experimental results showed that not only a pH gradient was well established along the open paper fluidic channel as confirmed by pH indicator strip, the pH gradient range could also be tuned by the catholyte or anolyte. Furthermore, the isoelectric focusing fractions from the paper channel can be directly cut and recovered into solutions for post analysis with sodium dodecyl sulfate‐polyacrylamide gel electrophoresis and matrix‐assisted laser desorption/ionization‐time‐of‐flight mass spectrometry. This paper‐based isoelectric focusing method is fast, cheap, simple and easy to operate, and could potentially be used as a cost‐effective protein sample clean‐up method for target protein analysis with mass spectrometry.  相似文献   

20.
《Electrophoresis》2018,39(8):1040-1047
Isoelectric focusing (IEF) is a powerful separation method, useful for resolving subtle changes in the isoelectric point of unlabeled proteins. While microfluidic IEF has reduced the separation times from hours in traditional benchtop IEF to minutes, the enclosed devices hinder post‐separation access to the sample for downstream analysis. The two‐layer open IEF device presented here comprises a photopatterned hydrogel lid layer containing the chemistries required for IEF and a thin polyacrylamide bottom layer in which the analytes are separated. The open IEF device produces comparable minimum resolvable difference in isoelectric point and gradient stability to enclosed microfluidic devices while providing post‐separation sample access by simple removal of the lid layer. Further, using simulations, we determine that the material properties and the length of the separation lanes are the primary factors that affect the electric field magnitude in the separation region. Finally, we demonstrate self‐indexed photomasks for alignment‐free fabrication of multi‐domain hydrogels. We leverage this approach to generate arrayed pH gradients with a total of 80 concurrent separation lanes, which to our knowledge is the first demonstration of multiple IEF separations in series addressed by a single pair of electrodes.  相似文献   