首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
《Electroanalysis》2004,16(4):268-274
An amperometric method for the determination of the neurotoxic amino acid β‐N‐oxalyl‐L ‐α,β‐diaminopropionic acid (β‐ODAP) using a screen printed carbon electrode (SPCE) is reported. The electrode material was bulk‐modified with manganese dioxide and used as a detector in flow injection analysis (FIA). The enzyme glutamate oxidase (GlOx) was immobilized in a Nafion‐film on the electrode surface. The performance of the biosensor was optimized using glutamate as an analyte. Optimum parameters were found as: operational potential 440 mV (vs. Ag/AgCl), flow rate 0.2 mL min?1, and carrier composition 0.1 mol L?1 phosphate buffer (pH 7.75). The same conditions were used for the determination of β‐ODAP. The signal was linear within the concentration range 53–855 μmol L?1 glutamate and 195–1950 μmol L?1 β‐ODAP. Detection limits (as 3σ value) for both analytes were 9.12 and 111.0 μmol L?1, respectively, with corresponding relative standard deviations of 3.3 and 4.5%. The biosensor retained more than 73% of its activity after 40 days of on‐line use.  相似文献   

2.
A system of Pt nanoparticles and poly(ortho‐phenylenediamine) film electrochemically deposited onto a glassy carbon electrode (GCE/PoPD/Pt) was fabricated. Scanning electron microscopy, Fourier‐transform infrared spectroscopy, and atomic force microscopy techniques were used to identify the surface characteristics of the composite electrode. The conductive polymers and Pt nanoparticles together resulted in a synergistic effect, and the new formed surface was highly active against polyphenolic structures. Rosmarinic acid (RA) and protocatechuic acid (PCA) are phenolic compounds found in plants, and they are used in many applications, particularly as pharmaceuticals. The GCE/PoPD/Pt was used for the simultaneous determination of RA and PCA in a pH 2.0 H2SO4 solution for the first time. The RA and PCA concentrations were determined using differential pulse voltammetry (DPV) and chronoamperometry. By the amperometry measurement, for RA and PCA, a linear relation was observed in the concentration ranges of 1–55 μmol L?1 and 1–60 μmol L?1, with detection limits of 0.5 μmol L?1 and 0.6 μmol L?1, respectively. In the simultaneous determination with DPV, the detection limits for both RA and PCA were calculated as 0.7 μmol L?1. The GCE/PoPD/Pt was successfully used for the simultaneous determination of RA and PCA in a real sample, and its accuracy was verified by high‐performance liquid chromatography studies.  相似文献   

3.
Voltammetric behavior of sodium 7‐methoxyl‐4′‐hydroxylisoflavone‐3′‐sulfonate (SMHS) in the aqueous solution from pH 1 to 5 was studied by linear sweep voltammetry, cyclic voltammetry and normal pulse voltammetry. Experimental results showed that in 0.2 mol*L?1 sodium citrate‐hydrochloric acid buffer solution (pH=4.65), SMHS caused only one reduction wave at ?1.34 V (vs. saturated calomel electrode, SCE), which was an h‐reversible adsorptive wave of SMHS protonized involving one electron and one proton. The peak current of SMHS on linear sweep voltammogram was proportional to its concentration in the range of 8.0 × 10 ?8.0·10 mol*L?1 (r = 0.995). and the detection limit was 5.0·10?6mol*L?1. The method was applied to determination of SMHS, in synthetic samples. In addition, its scavenging effect on superoxide anion radical was studied by the auto‐oxidation of pyrogallol in HCI‐tris buffer solution (pH = 8.2) in order to explain its peculiar biological effects. The experimental results proved that SMHS has antioxidant quality, and it is an efficient free radical scavenger of superoxide anion radical.  相似文献   

4.
N‐(3,4‐dihydroxyphenethyl)‐3,5‐dinitrobenzamide modified multiwall carbon nanotubes paste electrode was used as a voltammetric sensor for oxidation of penicillamine (PA), uric acid (UA) and tryptophan (TP). In a mixture of PA, UA and TP, those voltammograms were well separated from each other with potential differences of 300, 610, and 310 mV, respectively. The peak currents were linearly dependent on PA, UA and TP concentrations in the range of 0.05–300, 5–420, and 1.0–400 µmol L?1, with detection limits of 0.021, 2.0, and 0.82 µmol L?1, respectively. The modified electrode was used for the determination of those compounds in real samples.  相似文献   

5.
《Electroanalysis》2004,16(23):1977-1983
2,2‐bis(3‐Amino‐4‐hydroxyphenyl)hexafluoropropane (BAHHFP) was electro‐polymerized oxidatively on glassy carbon by cyclic voltammetry. The activity of the modified electrode towards ascorbic acid (AA), uric acid (UA) and dopamine (DA) was characterized with cyclic voltammetry and differential puls voltammetry (DPV). The findings showed that the electrode modification drastically suppresses the response of AA and shifts it towards more negative potentials. Simultaneously an enhancement of reaction reversibility is seen for DA and UA. Unusual, selective preconcentration features are observed for DA when the polymer‐modified electrode is polarized at negative potential. In a ternary mixture containing the three analytes studied, three baseline resolved peaks are observed in DPV mode. At physiological pH 7.4, after 5 min preconcentration at ?300 mV, peaks positions were ?0.073, 0.131 and 0.280 V (vs. Ag/AgCl) for AA, DA and UA, respectively. Relative selectivities DA/AA and UA/AA were over 4000 : 1 and 700 : 1, respectively. DA response was linear in the range 0.05–3 μM with sensitivity of 138 μA μM?1 cm?2 and detection limit (3σ) of 5 nM. Sensitive quantification of UA was possible in acidic solution (pH 1.8). Under such conditions a very sharp peak appeared at 630 mV (DPV). The response was linear in the range 0.5–100 μM with sensitivity of 4.67 μA μM?1 cm?2 and detection limit (3σ) of 0.1 μM. Practical utility was illustrated by selective determination of UA in human urine.  相似文献   

6.
《Electroanalysis》2005,17(17):1517-1522
In this paper, we report the first attempt to use humic acid (HA) as modifiers to prepare the organic‐inorganic hybrid modified glassy carbon electrodes based on HA‐silica‐PVA (poly(vinyl alcohol)) sol‐gel composite. Electroactive species of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy) ) can easily incorporate into the HA‐silica‐PVA films to form Ru(bpy) modified electrodes. The amount of Ru(bpy) incorporated in the composite films strongly depends on the amount of HA in the hybrid sol. Electrochemical and electrogenerated chemiluminescence (ECL) of Ru(bpy) immobilized in HA‐silica composite films coated on a glassy carbon electrode have been studied with tripropylamine (TPA) as the coreactant. The analytical performance of this modified electrode was evaluated in a flow injection analysis (FIA) system with a homemade flow cell. The as‐prepared electrode showed good stability and high sensitivity. The detection limits (S/N=3) were 0.050 μmol L?1 for TPA and 0.20 μmol L?1 for oxalate, and the linear ranges were from 0.10 μmol L?1 to 1.0 mmol L?1 for TPA and from 1.0 μmol L?1 to 1.0 mmol L?1 for oxalate, respectively. The resulting electrodes were stable over two months.  相似文献   

7.
This work demonstrates gold nanoparticles (AuNPs)/functionalized multiwalled carbon nanotubes (f‐MWCNT) composite film modified gold electrode via covalent‐bonding interaction self‐assembly technique for simultaneous determination of salsolinol (Sal) and uric Acid (UA) in the presence of high concentration of ascorbic acid (AA). In pH 7.0 PBS, the composite film modified electrode exhibits excellent voltammetric response for Sal and UA, while AA shows no voltammetric response. The oxidation peak current is linearly increased with concentrations of Sal from 0.24–11.76 μmol L?1 and of UA from 3.36–96.36 μmol L?1, respectively. The detection limits of Sal and UA is 3.2×10?8 mol L?1 and 1.7×10?7 mol L?1 , respectively.  相似文献   

8.
This work reports the application of bismuth bulk electrode (BiBE) for the determination of 2‐methyl‐4,6‐dinitrophenol (MDNP) by differential pulse voltammetry (DPV) in Britton‐Robinson buffer of pH 12.0 as an optimal medium. BiBE was prepared by transferring molten bismuth into a glass tube under constant stream of nitrogen. The linear concentration dependences were measured from 1 to 10 μmol ? L?1 and from 10 to 100 μmol ? L?1 by using optimum accumulation potential of ?0.7 V and optimum accumulation time 30 s. Under these conditions limit of determination and limit of quantification was 0.45 and 1.5 μmol ? L?1, respectively. The developed method was successfully applied for the analysis of tap water as a model sample.  相似文献   

9.
A cathodically pretreated boron‐doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry. Linear calibration curves (r=0.999) were obtained from 1.9×10?5 to 2.1×10?4 mol L?1 for AA and from 9.7×10?6 to 1.1×10?4 mol L?1 for CAF, with detection limits of 19 μmol L?1 and 7.0 μmol L?1, respectively. This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations, with results equal to those obtained using a HPLC reference method.  相似文献   

10.
《Electroanalysis》2006,18(3):291-297
Selected from a series of structurally related heteroaromatic thiols, a newly synthesized reagent 2‐amino‐5‐mercapto‐[1,3,4] triazole (MATZ) was used to fabricate self‐assembled monolayers (SAMs) on gold electrode for the first time. The MATZ/Au SAMs was characterized by electrochemical methods and scanning electronic microscopy (SEM). In 0.04 mol/L Britton–Robinson buffer solution (pH 5), the electrochemical behavior of dopamine showed a quasireversible process at the MATZ/Au SAMs with an electrode kinetic constant 0.1049 cm/s. However, the electrochemical reaction of uric acid at the SAMs electrode showed an irreversible oxidation process, the charge‐transfer kinetics of uric acid was promoted by the SAMs. By Osteryoung square‐wave voltammetry (OSWV), the simultaneous determination of dopamine and uric acid can be accomplished with an oxidation peak separation of 0.24 V, the peak current of dopamine and uric acid were linearly to its concentration in the range of 2.5×10?6–5.0×10?4 mol/L for dopamine and 1×10?6–1×10?4 mol/L for uric acid with a detection limit of 8.0×10?7 mol/L for dopamine and 7.0×10?7 mol/L for uric acid. The MATZ/Au SAMs electrode was used to detect the content of uric acid in real urine and serum sample with satisfactory results.  相似文献   

11.
An ionic liquid (IL) 1‐(3‐chloro‐2‐hydroxy‐propyl)‐3‐methylimidazolium trifluoroacetate was used as the modifier for the preparation of the modified carbon paste electrode (CPE). The IL‐CPE showed excellent electrocatalytic activity towards the oxidation of guanosine‐5′‐triphosphate (5′‐GTP) in a pH 5.0 Britton‐Robinson buffer solution. Due to the presence of high conductive IL on the electrode surface, the electrooxidation of 5′‐GTP was greatly promoted with a single well‐defined irreversible oxidation peak appeared. The electrode reaction was an adsorption‐controlled process and the electrochemical parameters of 5′‐GTP on IL‐CPE were calculated with the electron transfer coefficient (α) as 0.44, the electron transfer number (n) as 1.99, the apparent heterogeneous electron transfer rate constant (ks) as 2.21 × 10?9 s?1 and the surface coverage (ΓT) as 1.53 × 10?10 mol cm?2. Under the selected conditions a linear calibration curve between the oxidation peak currents and 5′‐GTP concentration was obtained in the range from 2.0 to 1000.0 μmol L?1 with the detection limit as 0.049 μmol L?1 (3σ) by differential pulse voltammetry. The proposed method showed good selectivity to the 5‘‐GTP detection without the interferences of coexisting substances and the practical application was checked by measurements of the artificial samples.  相似文献   

12.
A sensitive and selective method for the determination of Sb3+ based on the formation of its complexes with 8‐hydroxyquinoline (HQ) and 8‐hydroxyquinoline‐5‐sulfonic acid (HQS) is proposed. The best analytical conditions are: pH 5.4 and 2.2 for HQ and HQS, respectively; CHQ from 15.0 to 25.0 µmol L?1 and CHQS from 70.0 to 200.0 µmol L?1. The detection limits are 100.0 and 14.0 ng L?1 (tacc=30 s) for Sb3+ with HQ and HQS, respectively. The method using HQS as ligand has a 2.2‐fold higher sensitivity than that with HQ and the former was chosen for Sb3+ determination.  相似文献   

13.
《Electroanalysis》2003,15(21):1687-1692
Interfacial activity of uranium(VI)‐cupferron and uranium(VI)‐chloranilic acid (CAA) complexes (in 0.1 M acetate buffer pH 4.6 or 0.1 M NaClO4 respectively) on polarized mercury electrode at 110 mV, 10 mV or ?240 mV respectively vs. saturated calomel electrode (SCE), and under conditions of the application of adsorptive stripping voltammetric techniques was studied. It revealed a competitive effect of interfacial activity of the mentioned complexes consisting in a nonmonotonous effect of the bulk concentration of U(VI) on the adsorption of the mentioned complexing reagents at their constant concentrations. At concentrations lower than 5×10?5 mol L?1 the complexes U(VI)‐cupferron or U(VI)‐CAA exhibited a relatively strong electrosorption providing the adsorption coefficients β of the order 104 L mol?1, the maximum surface excess Γm ≈ 5 to 10 μmol m?2 and average Frumkin interaction coefficients reaching their absolute values 2 to 2.6.  相似文献   

14.
To help to clarify therapeutic functions of lipoic acid (LA) in biochemical and clinical practice we have elaborated a fast, simple and accurate HPLC method enabling determination of LA in human urine. The proposed analytical approach includes reduction of LA with tris(2‐carboxyethyl)phosphine and simultaneous separation and derivatization of the analyte with butylamine and o‐phthaldialdehyde followed by spectrofluorimetric detection at λex = 340 nm and λem = 440 nm. The assay was performed using gradient elution and the mobile phase containing 0.0025 mol L?1 o‐phthaldialdehyde in 0.0025 mol L?1 NaOH and acetonitrile. Linearity of the detector response for LA was observed in the range of 0.3–8 μmol L?1. Limits of detection and quantification for LA in urine samples were 0.02 and 0.03 μmol L?1, respectively. The total analysis time, including sample work‐up, was <20 min. The analytical procedure was successfully applied to analysis of real urine samples delivered from six healthy volunteers who received a single 100 mg dose of LA.  相似文献   

15.
Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self‐assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self‐assembling gold nanoparticles on the surface of L ‐cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well‐defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197 V and Epc=0.146 V, respectively. And the peak separation between DA and AA is about 0.2 V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10?8–8.5×10?5 mol L?1 and 1.0×10?6–2.5×10?3 mol L?1, with the detection limit of 2.0×10?8 mol L?1 and 3.0×10?7 mol L?1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result.  相似文献   

16.
A new electrochemical method was proposed for the determination of adenosine‐5′‐triphosphate (ATP) based on the electrooxidation at a molecular wire (MW) modified carbon paste electrode (CPE), which was fabricated with diphenylacetylene (DPA) as the binder. A single well‐defined irreversible oxidation peak of ATP appeared on MW‐CPE with adsorption‐controlled process and enhanced electrochemical response in a pH 3.0 Britton‐Robinson buffer solution, which was due to the presence of high conductive DPA in the electrode. The electrochemical parameters of ATP were calculated with the electron transfer coefficient (α) as 0.54, the electron transfer number (n) as 1.9, the apparent heterogeneous electron transfer rate constant (ks) as 2.67 × 10?5 s?1 and the surface coverage (ΓT) as 4.15 × 10?10 mol cm?2. Under the selected conditions the oxidation peak current was proportional to ATP concentration in the range from 1.0 × 10?7 mol L?1 to 2.0 × 10?3 mol L?1 with the detection limit as 1.28 × 10?8 mol L?1 (3σ) by sensitive differential pulse voltammetry. The proposed method showed good selectivity without the interferences of coexisting substances and was successful applied to the ATP injection samples detection.  相似文献   

17.
《Electroanalysis》2005,17(4):343-347
The adsorptive voltammetric behavior of the gallium‐alizarin red S (ARS) complex in NH4OAc‐HCl buffer at a carbon paste electrode(CPE) was investigated. The results showed that the complex can be adsorbed on the surface of the CPE, yielding one reduction peak at ?0.52 V(vs. SCE), corresponding to the irreversible reduction of the ligand, ARS, bonded in the complex. The optimal experimental conditions include the use of 0.10 mol L?1 ammonium acetate buffer(pH 4.5), 1.0×10?5 mol L?1 ARS, an accumulation potential of ?0.05 V, an accumulation time of 180 s ,a rest time of 10 s, a scan rate of 200 mV s?1and a second‐order derivative linear scan mode. The peak current is proportional to the concentration of gallium(III) over the range 0.02–6.0 μg L?1, with the detection limit of 0.01 μg L?1 for an accumulation time of 180 s. The method was applied to the determination of gallium in food samples with satisfactory results.  相似文献   

18.
In this paper 1‐(2‐pyridylazo)‐2‐naphthol (PAN) and ionic liquid 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) were mixed with graphite powder to get a modified carbon paste electrode (PAN‐IL‐CPE), which was further used for the sensitive determination of bismuth(III). By the co‐contribution of the formation of PAN‐Bi complex and the accumulation effect of IL, more bismuth(III) was electrodeposited on the surface of the PAN‐IL‐CPE. Then the reduced Bi was oxidized and detected by differential pulse anodic stripping voltammetry (DPASV) with the oxidation peak appeared at 0.17 V (vs. SCE). Under the optimal conditions the oxidation peak current was proportional to the bismuth(III) concentration in the range from 0.04 to 7.5 μmol L?1 with the detection limit as 3.9 nmol L?1. The proposed method was successfully applied to the stomach medicine sample detection with good recovery.  相似文献   

19.
This paper describes the development a novel ruthenium(II) complex‐ZnO/CNTs modified carbon paste electrode (Ru(II)/ZnO/CNTs/CPE) for the electrocatalytic determination of ascorbic acid (AA). The objective of this novel electrode modification was to seek new electrochemical performances for the detection of AA, nicotinamide adenine dinucleotide (NADH) and folic acid (FA). The peak potentials recorded were 170, 500 and 830 mV vs. Ag/AgCl/KClsat for AA, NADH and FA, respectively. The peak currents were linearly dependent on AA, NADH and FA concentrations using square wave voltammetry (SWV) method at the ranges of 0.008–251, 1.0–650, and 3.0–700 µmol L?1, with detection limits of 0.005, 0.5, and 1.0 µmol L?1, respectively.  相似文献   

20.
A simple and sensitive method for simultaneously measuring dopamine (DA), ascorbic acid (AA), and uric acid (UA) using a poly(1‐aminoanthracene) and carbon nanotubes nanocomposite electrode is presented. The experimental parameters for composite film synthesis as well as the variables related to simultaneous determination of DA, AA, and UA were optimized at the same time using fractional factorial and Doehlert designs. The use of carbon nanotubes and poly(1‐aminoanthracene) in association with a cathodic pretreatment led to three well‐defined oxidation peaks at potentials around ?0.039, 0.180 and 0.351 V (vs. Ag/AgCl) for AA, DA, and UA, respectively. Using differential pulse voltammetry, calibration curves for AA, DA, and UA were obtained over the range of 0.16–3.12×10?3 mol L?1, 3.54–136×10?6 mol L?1, and 0.76–2.92×10?3 mol L?1, with detection limits of 3.95×10?5 mol L?1, 2.90×10?7 mol L?1, and 4.22×10?5 mol L?1, respectively. The proposed method was successfully applied to determine DA, AA, and UA in biological samples with good results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号