首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, rapid, and reliable liquid–liquid extraction coupled to GC–MS method was developed and validated for the quantification of 22 phthalate esters (PAEs) in honey and royal jelly. Instrument parameters for GC–MS were tested to obtain the satisfactory separation between 22 PAEs with high sensitivity. The extraction procedure was optimized in order to achieve the best recovery. The following criteria were used to validate the developed method: linearity, LOD, lower LOQ, precision, accuracy, matrix effect and carry‐over. Correlation coefficients were >0.999 by applying the linear regression model based on the least‐squares method with a weighting factor (1/x). The intra‐ and interday precision were within 12.7% in terms of RSD, and the accuracy was within ?11.8% in terms of relative error. The mean extraction recoveries ranged between 80.1 and 110.9% for honey and royal jelly. No significant matrix effect and carry‐over for PAEs were observed for the analysis of honey and royal jelly samples. A total of 20 real samples were analyzed for a mini‐survey using the developed method. Seven PAEs in honey samples and five PAEs in royal jelly samples were found, indicating potential contamination with several PAEs.  相似文献   

2.
The applicability of CZE with mass spectrometric detection for the determination of four chlorine species, namely chloride and three stable chlorine oxyanions, was studied. The main aspects of the proper selection of BGE and sheath liquid for the CE‐MS determinations of anions with high mobility were demonstrated, pointing out the importance of pH and the mobility of the anion in the BGE. The possibility of using uncoated fused silica capillary and common electrolytes for the separation was shown and the advantage of using extra pressure at the inlet capillary end was also presented. The linear range was found to be 1–100 µg/mL for ClO3? and ClO4?, 5–500 µg/mL for ClO2?, and 25–500 µg/mL for Cl?, but the sensitivity can be greatly improved if larger sample volume is injected and electrostacking effect is utilized. The LOD for ClO3? in drinking water was 6 ng/mL, when very large sample volume was injected (10 000 mbar·s was applied).  相似文献   

3.
A simple semi-automated dispersive liquid–liquid microextraction system was designed and used for off-line preconcentration and determination of nickel (II) ion in some food samples. The methodology submitted in the present work is based upon the microextraction of [Ni(C38H28O2N)2] complex employing an orange peel oil (OPO) as an extractant without a dispersing solvent and the estimation of nickel (II) ion in sediment by electrothermal atomic absorption spectrometry (ETAAS). 3 mL of sample solution, 0.5 mL of acetate buffer (pH 6), and 300 µL of the complexing agent (1-[4-[(2-hydroxynaphthalen-1-yl)methylideneamino] phenyl]ethanone) (HNE) dissolved in OPO were automatically transferred to separation tube and the cloudy solution was obtained by dispersing OPO as droplets throughout the aqueous phase using nitrogen gas. Under the optimized conditions, the analytical methodology used in this study provided a good efficiency in term of sensitivity and selectivity where the calibration plot was linear in the range of 5–150 ngL–1, while, the enhancement factor (EF) and the detection limit were 300 and 0.87 ngL–1, respectively for a sample volume of 3 mL. On the other hand, the method was completely free of most potential interferences. Certified reference wheat sample (NCS ZC11018) and some food samples were used to evaluate the developed method and results were compared using ICP–MS. Moreover, the new [Ni(C38H28O2N)2] complex was synthesized and characterized using diverse characterization techniques.  相似文献   

4.
In this work a fast liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method was developed for the analysis of toltrazuril, a coccidiostatic drug, and its metabolites in meat food products. The applicability of atmospheric pressure chemical ionization (APCI) and heated electrospray ionization in both positive and negative modes was studied. APCI in negative mode provided the best results and the base peak originated from the loss of CF3 (toltrazuril and toltrazuril sulfone) and CHF3• (toltrazuril sulfoxide) was used as the precursor ion in MS/MS. A fast LC separation on a C18 Fused-Core™ column was used together with the APCI-MS/MS method developed using enhanced mass resolution mode (highly selective selected reaction monitoring, H-SRM) to improve the sensitivity and selectivity for the analysis of these compounds in food samples. A simple sample treatment based on an extraction with acetonitrile and a cleanup with a C18 cartridge was used. The LC-MS/MS (H-SRM) method showed good precision (relative standard deviation lower than 10%), accuracy, and linearity and allowed the determination of these compounds in food samples down to the parts per billion level (limits of detection between 0.5 and 5 μg kg-1).  相似文献   

5.
This study developed a facile, highly sensitive technique for extracting and quantifying barbiturates in serum samples. This method combined ultrasound and surfactant-assisted dispersive liquid–liquid microextraction with poly(ethylene oxide)-mediated stacking in capillary electrophoresis. Factors influencing the extraction and stacking performance, such as the type and volume of extraction solvents, the type and concentration of surfactant, extraction time, salt additives, sample matrix, solution pH, and composition of the background electrolyte, were carefully studied and optimized to achieve the optimal detection sensitivity. Under the optimized extraction (injecting 140 μL C2H4Cl2 into 1 mL of sample with pH 4 (5 mM sodium phosphate containing 0.05 mM Tween 20 and sonication for 1 min) and separation conditions (150 mM tris(hydroxymethyl)aminomethane-borate with pH 8.5 containing 0.5% (m/v) poly(ethylene oxide)), the limits of detection (signal-to-noise ratio = 3) of five barbiturates ranged from 0.20 to 0.33 ng/mL, and the calculated sensitivity improvement ranged from 868- to 1700-fold. The experimental results revealed excellent linearity (R2 > 0.99), with relative standard deviations of 2.1%–3.4% for the migration time and 4.3%–5.7% for the peak area. The recoveries of the spiked serum samples were 97.1% –110.3%. Our proposed approach offers a rapid and practical method for quantifying barbiturates in biological fluids.  相似文献   

6.
A sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry method was established to separate and identify the chemical constituents of Zhi–Zi–Da–Huang decoction, a classic traditional Chinese medicine formula. The chromatographic separation was achieved on a Shim‐pack XR‐ODS C18 column (75  × 3.0 mm, 2.2 μm) using a gradient elution program. The detection was performed on a Waters Xevo G2 Q‐TOF mass spectrometer equipped with electrospray ionization source in both positive and negative modes. With the optimized conditions, a total of 82 compounds were identified or tentatively characterized. Of the 82 compounds, 21 compounds were identified by comparing the retention time and MS data with reference standards, the rest were characterized by analyzing MS data and retrieving the reference literature. In addition, 31 compounds were identified from Gardenia jasminoides Ellis, ten compounds were identified from Rheum palmatum L., 33 compounds were identified from Citrus aurantium L., and eight compounds were identified from Sojae Semen Praeparatum. Results indicated that iridoids, anthraquinones, flavonoids, isoflavonoids, coumarins, glycosides of crocetin, monoterpenoids, and organic acids were major constituents in Zhi–Zi–Da–Huang decoction. It is concluded that the developed ultra high performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry method with high sensitivity and resolution is suitable for identifying and characterizing the chemical constituents of Zhi–Zi–Da–Huang decoction, and the analysis provides a helpful chemical basis for further research on Zhi–Zi–Da–Huang decoction.  相似文献   

7.
A reversed-phase high-performance liquid chromatographic (HPLC) method is applied for the determination of galacturonic acid (GA) of pectins in different commercial fruit juices. The separation was carried out on a C18 column using precolumn derivatization with p-aminobenzoic acid (p-ABA) and UV detection at 304 nm. The identification of GA was confirmed by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) in positive ion mode. The concentration of GA in the samples analyzed ranged from 12.9 ± 0.5 to 49.4 ± 0.5 mgGA L−1. Amongst the samples analyzed, mango juice was found to be richest in GA content, and therefore a good source of pectins. Detection and quantification limits of the described methodology were 1.2 and 3.9 mg L−1, respectively. Quantitative GA recoveries in the beverages had a range between 90 and 98%. The results showed that the HPLC method proposed was precise and suitable for the identification and quantification of GA in commercial fruit juices.  相似文献   

8.
A rapid and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of echinacoside in rat plasma was established and fully validated. A single step of liquid–liquid extraction with n‐butanol was utilized. Chromatographic separation of the analyte and the internal standard (IS), chlorogenic acid, from the sample matrix was performed using a Capcell‐MG C18 analytical column (100 2.0 mm × 5 µm), with a gradient of acetonitrile and water containing 0.1% acetic acid as the mobile phase. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization source operated in negative ion selected reaction monitoring mode. The method was linear in the concentration range 10–2500 ng/mL. The deviations of both intra‐ and inter‐day precisions (RSD) were 7.1% and the assay accuracies were within 99.2–106.5%. Echinacoside proved to be stable during sample storage, preparation and analysis when an antioxidant solution was used. The method was successfully applied to a pharmacokinetic study in rats after an intragastric administration of echinacoside (100 mg/kg). With the lower limit of quantification at 10 ng/mL, this method proved to have sufficient selectivity, sensitivity and reproducibility for the pharmacokinetic study of echinacoside. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive high‐performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid–liquid extraction. Chromatographic separation was achieved on a C18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile–water (90:10, v /v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2 = 0.9998). The intra‐ and inter‐day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC–MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability.  相似文献   

10.
A bioanalytical method for the quantification of rosiglitazone in rat plasma and tissues (adipose tissue, heart, brain, bone, and kidney) using LC–MS/MS was developed and validated. Chromatographic separation was achieved on a Gemini C18 column (50 × 4.6 mm, 3 μm) using a mobile phase consisting of 10 mM ammonium formate (pH 4.0) and acetonitrile (10:90, v/v) at a flow rate of 0.8 mL/min and injection volume of 10 μL (internal standard: pioglitazone). LC–MS detection was performed with multiple reaction monitoring mode using target ions at m/z → 358.0 and m/z → 357.67 for rosiglitazone and pioglitazone (internal standard), respectively. The calibration curve showed a good correlation coefficient (r2) over the concentration range of 1–10,000 ng/mL. The mean percentage recoveries of rosiglitazone were found to be over the range of 92.54–96.64%, with detection and lower quantification limit of 0.6 and 1.0 ng/mL, respectively. The developed method was validated per U.S. Food and Drug Administration guidelines and successfully utilized to measure rosiglitazone in plasma and tissue samples. Further, the developed method can be utilized for validating specific organ-targeting delivery systems of rosiglitazone in addition to conventional dosage forms.  相似文献   

11.
The fabrication of novel poly(ionic liquids)‐modified polystyrene (PSt) magnetic nanospheres (PILs‐PMNPs) by a one‐pot miniemulsion copolymerization reaction was achieved through an efficient microwave‐assisted synthesis method. The morphology, structure, and magnetic behavior of the as‐prepared magnetic materials were characterized by using transmission electron microscopy, vibrating sample magnetometry, etc. The magnetic materials were utilized as sorbents for the extraction of phthalate esters (PAEs) from beverage samples followed by high‐performance ultrafast liquid chromatography analysis. Significant extraction parameters that could affect the extraction efficiencies were investigated particularly. Under optimum conditions, good linearity was obtained in the concentration range of 0.5–50 (dimethyl phthalate), 0.3–50 (diethyl phthalate), 0.2–50 (butyl benzyl phthalate), and 0.4–50 μg/L (di‐n‐butyl phthalate), with correlation coefficients R 2 > 0.9989. Limits of detection were in the range 125–350 pg. The proposed method was successfully applied to determine PAEs from beverage samples with satisfactory recovery ranging from 77.8 to 102.1% and relative standard deviations ranging from 3.7 to 8.4%. Comparisons of extraction efficiency with PSt‐modified MNPs as sorbents were performed. The results demonstrated that PILs‐PMNPs possessed an excellent adsorption capability toward the trace PAE analytes.  相似文献   

12.
A high‐throughput miniaturized liquid–liquid extraction procedure followed by a simple ultra‐high performance liquid chromatography method coupled with fluorescence detection for bioanalytical analysis of all tocopherol isomers and retinol in human serum has been developed and validated. In the extraction procedure, a synthetic internal standard tocol was used, which does not occur in the human body. The separation of structurally related vitamins was achieved using a new generation of pentafluorophenyl propyl core–shell stationary phase with elution using methanol and an aqueous solution of ammonium acetate. The fluorescence of retinol and tocopherol isomers was detected at λex = 325, 295 nm and λem = 480, 325 nm, respectively. The rapid baseline separation of all analytes was accomplished within 4.0 min. The sensitivity of method was demonstrated with lower limits of quantification: retinol 0.01 μM, α‐tocopherol 0.38 μM, β‐tocopherol 0.18 μM, γ‐tocopherol 0.14 μM, and δ‐tocopherol 0.01 μM. Possible application of this method in clinical practice was confirmed by the analysis of human serum samples from healthy volunteers. Finally, the simultaneous determination of retinol and all tocopherol isomers in human serum can enable the clarification of their role in metabolism and in diseases such as cancer.  相似文献   

13.
A rapid, selective and sensitive ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed to detect meloxicam in human plasma. A triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source was used in positive ion mode. Protein precipitation with acetonitrile was used for sample preparation. Meloxicam and 13C6-meloxicam internal standard were analyzed on an Acquity CSH C18 column with a mobile phase of acetonitrile and water in 0.1% formic acid using a gradient program for separation. The retention time of meloxicam was 1.1 min and the total run time was only 2.0 min. Detection was performed in multiple reaction monitoring mode using an electrospray ionization source with optimized mass spectrometry parameters. The calibration curves were linear in the range 10.0–3.00 × 103 ng/ml (r ≥ 0.99). The within-run and between-run RSDs were ≤14.8%. The within-run and between-run REs ranged from −4.6 to 10.7%. There was no significant matrix effect, and the recovery rate was high. This method was fully validated, including reinjection reproducibility in human plasma. The method was applied to the pharmacokinetic study. All of the incurred sample reanalysis methods met the criteria.  相似文献   

14.
Quizartinib is a highly potent inhibitor of the fms‐like tyrosine kinase receptor, which is one of the most commonly mutated genes in acute myeloid leukemia. Quizartinib has shown a significant antileukemic clinical influence among relapsed/refractory acute myeloid leukemia patients. This study aimed at developing and validating an analytical method for the measurement of quizartinib in rat plasma using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The method was validated according to US Food and Drug Administration guidelines, and the results obtained in this work met the set criteria. Liquid–liquid extraction was used and chromatographic separation was achieved on a BEHTM C18 column. Detection of quizartinib was achieved in multiple reaction monitoring mode using positive‐ion mode electrospray ionization. The MS/MS ion transitions at mass‐to‐charge ratios (m/z) of 561.129/114.09 and 441.16/84.03 were monitored for quizartinib and ibrutinib, respectively. The linear detection range was 2–1000 ng/mL (r > 0.998), with intra‐ and inter‐day assay precisions ≤13.07 and 13.17%, respectively. This rapid, simple and sensitive method was validated and successfully applied to the pharmacokinetic study of quizartinib in rat samples.  相似文献   

15.
The presence of pesticides in food items and beverages is a big threat to humankind, and their quantitative estimation with high precision and accuracy is always a challenge for analytical chemists. Hence, a simple and rapid method is proposed for the simultaneous determination of 30 pesticides in beverages (alcoholic and non‐alcoholic drinks). The proposed method hyphenated with triple quadrupole liquid chromatography mass spectrometry has only 2 min chromatographic runtime for the analysis of all the pesticides. All the factors affecting the extraction yield have been optimized using an experimental design; and under optimized conditions, the developed method has been validated. The detection limits for all the pesticides were in the range of 0.001–0.348 μg/L with good linearity in the concentration range of 0.01–80.0 μg/L. The coefficient of determination was in the range of (R2) ≥ 0.977 to 0.999 for all the pesticides. The method was also checked for the precision of the relative standard deviation, which was below 4.75 (intra‐day) and 8.96% (inter‐day). The recovery of the method was 92–138%.  相似文献   

16.
Hou S  Zhu J  Ding M  Lv G 《Talanta》2008,76(4):798-802
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for simultaneous determination of three representative phytohormones in plant samples: gibberellic acid (GA3), indole-3-acetic acid (IAA) and abscisic acid (ABA). A solid-phase extraction (SPE) pretreatment method was used to concentrate and purify the three phytohormones of different groups from plant samples. The separation was carried out on a C18 reversed-phase column, using methanol/water containing 0.2% formic acid (50:50, v/v) as the isocratic mobile phase at the flow-rate of 1.0 mL min−1, and the three phytohormones were eluted within 7 min. A linear ion trap mass spectrometer equipped with electrospray ionization source was operated in negative ion mode. Selective reaction monitoring (SRM) was employed for quantitative measurement. The SRM transitions monitored were as 345 → 239, 301 for GA3, 174 → 130 for IAA and 263 → 153, 219 for ABA. Good linearities were found within the ranges of 5–200 μg mL−1 for IAA and 0.005–10 μg mL−1 for ABA and GA3. Their detection limits based on a signal-to-noise ratio of three were 0.005 μg mL−1, 2.2 μg mL−1 and 0.003 μg mL−1 for GA3, IAA and ABA, respectively. Good recoveries from 95.5% to 102.4% for the three phytohormones were obtained. The results demonstrated that the SPE-LC–MS/MS method developed is highly effective for analyzing trace amounts of the three phytohormones in plant samples.  相似文献   

17.
A novel, specific and rapid ultra performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for determination of teniposide in rat plasma. A one‐step liquid–liquid extraction method was used and the separation was carried out on an Acquity UPLCTM BEH C18 column with gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. A triple quadrupole tandem mass spectrometer in multiple‐reaction monitoring mode via an electrospray ionization interface was used for the detection of teniposide. The detection was complete within 3.0 min. A linear calibration curve was obtained over the concentration range 10–10,000 ng/mL for teniposide, with a lower limit of quantification of 10 ng/mL. The intra‐day precision and inter‐day precision (relative standard deviation) were less than 10.23 and 13.09%, respectively. The developed method was applied for the first time to the pharmacokinetic study of teniposide in rats following a single intravenous administration of 4.5 mg/kg teniposide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
Justicia procumbens is a food and medicine homologous variety, popularly used for making vegetable soups. In this study, a novel mesoporous silica was synthesized and used as the sorbent of SPE for the purification of lignans from J. procumbens. A laboratory-made SPE cartridge was packed with 100 mg of mesoporous silica, which was washed with 10% methanol and eluted using 0.8 mL acetonitrile after sample loading. Afterward, the extract was analyzed by ultra-performance liquid chromatography (UPLC) and MS/MS. All the lignans were efficiently separated in 6 min with the noise level in the range of 50–150 cps. 6′-Hydroxy justicidin B, 6′-hydroxy justicidin A, justicidin B, chinensinaphthol methyl ether, justicidin C, and neojusticdin A were identified to be the dominant molecular species in J. procumbens with contents of 0.065−0.37 mg/g in three tested sample batches from different geographic origins. In conclusion, the proposed mesoporous silica based SPE UPLC–MS/MS method is efficient in linearity (R2 = 0.9989−0.9996), sensitivity (LOD ≤0.13 μg/kg and LOQ ≤0.42 μg/kg), precision (RSDintra-day ≤3.12 and RSDinter-day ≤4.56), and recovery (83.42−96.11%, RSD ≤2.88%).  相似文献   

19.
Boldine is a potential anti‐inflammatory agent found in several different plants. Published bioanalytical methods using HPLC with ultraviolet and fluorescent detection lacked enough sensitivity and required tedious sample preparation procedures. Herein, we describe the development of a novel ultra‐high performance LC with MS/MS for determination of boldine in plasma. Boldine in plasma was recovered by liquid–liquid extraction using 1 mL of methyl tert‐butyl ether. Chromatographic separation was performed on a C18 column at 45°C, with a gradient elution consisting of acetonitrile and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. The detection was performed on an electrospray triple‐quadrupole MS/MS by positive ion multiple reaction monitoring mode. Good linearity (r2 > 0.9926) was achieved in a concentration range of 2.555–2555 ng/mL with a lower limit of quantification of 2.555 ng/mL for boldine. The intra‐ and inter‐day precisions of the assay were 1.2–6.0 and 1.8–7.4% relative standard deviation with an accuracy of ?6.0–8.0% relative error. This newly developed method was successfully applied to a single low‐dose pharmacokinetic study in rats and was demonstrated to be simpler and more sensitive than the published methods, allowing boldine quantification in reduced plasma volume. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
Tan  Xuerong  Jin  Quan  Lu  Jianwei  Zhao  Bin  Gou  Weini  Yang  Rong  Fu  Yu  Xu  Donghai  Zhang  Li 《Chromatographia》2022,85(5):433-445

A reliable and affordable QuEChERS (quick, easy, cheap, effective, rugged, and safe) methodology in combination with ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC–MS/MS) was successfully developed and validated for the determination of eight bisphenols (BPs) residues containing in meats (chicken, duck, beef, pork, fish, shrimp, and mutton). A novel QuEChERS method optimization was carried out in terms of process efficiency (PE), matrix effect (ME), and extraction recovery (RE). After a simple vortex extraction of the samples with acetonitrile, 1 g sodium acetate was used for salting out (NaAC), and 100 mg primary secondary amine (PSA) purifying reagents were used for purification. The properties of the sorbents were assessed by the obtained parameters, such as matrix effect (ME), linearity, sensitivity, accuracy, and precision. Under the optimal conditions, BPs were well separated on an ACQUITY UPLC BEH ® C18 column in 8 min by gradient elution, and exhibited a good linear relationship (R2?>?0.9988) in the linear range. Moreover, the limits of detection (LODs) and the limits of quantification (LOQs) were located in the range of 0.01– 0.11 μg/kg and 0.03 – 0.37 μg/kg, respectively. The developed method was satisfactory in terms of accuracy (relative recoveries: 76.1% – 113.7%) and precision (relative standard deviations below 10.3%). Finally, the developed method was successfully employed to identify and quantify BPs residues in 28 real meat samples. The proposed QuEChERS-UPLC–MS/MS method is simple, high efficiency, cost-effective, practical, and susceptible to being implemented in routine laboratories to quickly detect the BPs in meats (chicken, duck, beef, pork, fish, shrimp, and mutton). In this sense, the method is useful for obtaining BPs residue data to evaluate the contamination status of BPs in meat food and provide scientific support for scientific supervision.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号