首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A facile and sensitive multi‐residue detection approach of pressurized liquid extraction following high‐performance liquid chromatography tandem mass spectrometry was established to detect the residues of adrenergic drugs, steroids, sedative, colorant and antioxidant in feed. The conditions employed for pressurized liquid extraction involved acetonitrile/ethyl acetate (1:1, v/v) as the extracting solvent, the temperature 80°C, two cycles and a static time of 10 min. The extraction was followed by a solid‐phase extraction clean‐up step. The separation of samples was done by C18 column with the mobile phase of 5 mM ammonium acetate solution and acetonitrile with 0.1% formic acid. The limits of quantification ranged from 0.03 to 1 μg/kg, limits of detection were in a range of 0.01–0.5 μg/kg, and average recoveries were 70.4–98.6%. The pressurized liquid extraction procedure was optimized and overall method was validated in terms of sensitivity, linearity, selectivity, matrix effect, accuracy, recovery and stability of the target drugs in the pressurized liquid extraction extracts solution. The screening method was proved to be fast, selective, accurate and sensitive for screening drugs.  相似文献   

2.
A magnetite–polypyrrole composite adsorbent was synthesized and applied for the magnetic solid phase extraction of three non-steroidal anti-inflammatory drugs in aqueous solution and systematically investigated using Box–Behnken design. The synthesized composite adsorbent was characterized using Fourier-transform infrared spectroscopy, transmission electron microscopy, the Brunauer–Emmett–Teller method, vibrating sample magnetometry, and X-ray diffraction. The material was successfully modeled by Box–Behnken design (R2?=?0.94–0.98, p value: <0.001%) by monitoring the extraction efficiencies of naproxen, diclofenac sodium, and mefenamic acid. The analytes were determined using high-performance liquid chromatography with ultraviolet detection. The polymerization time was found to be the most significant factor, followed by amount of oxidant and monomer in the synthesis of the composite with a fixed Fe3O4 mass. Box–Behnken design was employed for the optimization of four parameters affecting the magnetic solid phase extraction: sample pH, salt addition, adsorption, and desorption time (R2?=?0.88–0.94). The optimized conditions for the procedure were validated, providing low detection limits (0.9–3.5?µg?L?1) with good reproducibility (<7.16% relative standard deviation) and excellent recoveries (97.87–100.49%) for tap, river, and wastewater samples. The synthesized adsorbent demonstrated good adsorption efficiency for the simultaneous determination of the non-steroidal anti-inflammatory drug residues.  相似文献   

3.
In the present study, a new extraction method based on a three–phase system, liquid–liquid–liquid extraction, followed by dispersive liquid–liquid microextraction has been developed and validated for the extraction and preconcentration of three commonly prescribed tricyclic antidepressant drugs – amitriptyline, imipramine, and clomipramine – in human plasma prior to their analysis by gas chromatography–flame ionization detection. The three phases were an aqueous phase (plasma), acetonitrile and n–hexane. The extraction mechanism was based on the different affinities of components of the biological sample (lipids, fatty acids, pharmaceuticals, inorganic ions, etc.) toward each of the phases. This provided high selectivity toward the analytes since most interferences were transferred into n–hexane. In this procedure, a homogeneous solution of the aqueous phase (plasma) and acetonitrile (water–soluble extraction solvent) was broken by adding sodium sulfate (as a phase separating agent) and the analytes were extracted into the fine droplets of the formed acetonitrile. Next, acetonitrile phase was mixed with 1,2–dibromoethane (as a preconcentration solvent at microliter level) and then the microextraction procedure mentioned above was performed for further enrichment of the analytes. Under the optimum extraction conditions, limits of detection and lower limits of quantification for the analytes were obtained in the ranges of 0.001–0.003 and 0.003–0.010 μg mL−1, respectively. The obtained extraction recoveries were in the range of 79–98%. Intra– and inter–day precisions were < 7.5%. The validated method was successfully applied for determination of the selected drugs in human plasma samples obtained from the patients who received them.  相似文献   

4.
A high efficiency HPLC method was developed by coupling three sub-2 μm columns in series and operating them at high temperature for the separation of selected non-steroidal anti-inflammatory drugs and veterinary antibiotics in environmental samples. The separation was performed at 80 °C to reduce the solvent viscosity, thus reducing the column backpressure. The chromatographic performance of high temperature-extended column length HPLC method was used to determine the most widely used non-steroidal anti-inflammatory drugs and veterinary antibiotics such as sulphonamides in wastewater samples. The method could simultaneously determine 24 pharmaceuticals in short analysis time with high efficiency. The method involved pre-concentration and clean-up by solid phase extraction (SPE) using Oasis HLB extraction cartridges. It was validated based on linearity, precision, detection and quantification limits, selectivity and accuracy. Good recoveries were obtained for all analytes ranging from 72.7% to 98.2% with standard deviations not higher than 6%, except for acetaminophen and acetyl salicylic acid, for which low recovery was obtained. The detection limits of the studied pharmaceuticals ranged from 2 to 16 μg L−1, while limits of quantification were in the range from 7 to 54 μg L−1 with UV detection.  相似文献   

5.
A rapid, efficient and environmentally friendly method based on the ionic liquid (IL) 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) was developed for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in mainstream tobacco smoke. This technique combined ionic liquid (IL) enrichment with solvent reverse extraction for the replacement of solid phase extraction and rotary evaporation in the traditional method and enriched PAHs in the organic solvent. Several parameters, including the type of ionic liquid, volume of ionic liquid and water, extraction time, vortex time and reverse extraction time, were optimized. After pretreatment, the analytes were analyzed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM). Satisfactory results were achieved when this method was applied to determine PAHs in mainstream tobacco smoke. The calibration curves were linear with correlation coefficients ranging from 0.9955 to 0.9999 at concentration levels of 10–800?µg?L?1, and the relative standard deviations of the optimized method were between 0.7% and 5.3%. The limits of detection were 0.01–0.6?ng cig?1, and the recoveries of the compounds were 80.2–118%. A comparison of this protocol with literature methods demonstrated that the proposed procedure provides accurate and reliable sample-treatment for the determination of PAHs in tobacco samples.  相似文献   

6.
A simple, environment friendly and efficient technique, ionic liquid‐based microwave‐assisted extraction was first used to determine malachite green and crystal violet (CV) from water samples coupled to HPLC. The key parameters influencing extraction efficiency were investigated, such as the type of ionic liquids, the volume of ionic liquid, extraction time, and so on. Under the optimum conditions, good reproducibility of the extraction performance was obtained (RSD, 1.0% for malachite green (MG) and 5.9% for CV, n = 5). Good linearity (0.10–25 μg L?1) was observed with correlation coefficients between 0.9991 and 0.9964. The detection limits of MG and CV were 0.080 and 0.030 μg L?1, respectively. The proposed method had been successfully applied to determine MG and CV in real water samples with recoveries ranging from 95.4 to 102.8%. Compared with the previous technologies, the proposed method required less extraction time (2 min), and provided lower detection limits and higher enrichment factors. Moreover, there were no volatile and hazardous organic solvents released. Based on these simple, environment friendly, rapid, and highly efficient results, the proposed approach provides a new and promising alternative for simultaneously extracting trace amounts of MG and CV from water.  相似文献   

7.
This article presents the development, validation and application of a new multi-residue method for simultaneous determination of 36 pharmaceuticals (histamine receptor antagonists, psychoactive stimulant, antiepileptics, antihypertensive, non-steroidal anti-inflammatory, analgesic and antipyretic, lipid regulator, antibiotics, antibacterial, skin care ingredient and metabolites of nicotine and lipid regulators) in surface water using solid phase extraction (Strata-X at pH 5) and liquid chromatography-tandem mass spectrometry (LC–MS/MS). Recoveries were greater than 70% with less than 20% SD for the majority of analytes. The instrumental quantification limit was between 2 and 181 pg, and method quantification limit varied from 0.5 to 98 ng L?1 in spiked stream water. The pH and sorbent dependence of matrix effects is discussed. The optimised method was used to determine the occurrence of target analytes in surface water from the coastal Lake Erie in Oregon, northwest Ohio. Seventeen analytes were detected with concentrations up to hundreds of nanogram per litre in stream and lake water samples.  相似文献   

8.
A highly sensitive method based on solid‐phase extraction and ultra high performance liquid chromatography with electrospray tandem mass spectrometry has been developed for simultaneous determination of five iodinated X‐ray contrast media in environmental water samples. Various solid‐phase extraction cartridges have been evaluated and a combination of LiChrolute EN and ENVI‐Carb solid phase extraction cartridges was selected for sample enrichment. The method was comprehensively validated on ground water, tap water, surface water, drinking water, and waste water by the conventional procedures: linearity, method detection limits, accuracy and precision, matrix effects. Good linearity (R2 > 0.999), low detection limits (0.4–8.1 ng/L), satisfactory recoveries (55.1–109.5%) and precision (0.8–10.0% for intra‐day precisions and 0.6–16.5% for inter‐day precisions) were obtained for all the target compounds. Iopamidol, iohexol, and diatrizoate in some matrices were affected by matrix effects, which were slightly eased by using the isotope‐labeled internal standard. The developed method was successfully applied for real samples collected in Shanghai, China, with detected concentrations up to 2200 ± 200 and 9000 ± 1000 ng/L for iohexol and iopamidol, respectively.  相似文献   

9.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

10.
The determination of acidic pharmaceuticals, such as non-steroidal anti-inflammatory drugs NSAIDs and clofibric acid (metabolite of clofibrate), at low ng L−1 levels in wastewater requires highly selective and sensitive analytical procedures. The removal of matrix components during sample preparation results in significant benefits towards reducing the matrix effects during LC-MS analysis. Therefore this work describes a simple method to enrich and clean up NSAIDs and clofibric acid from sewage water using molecularly imprinted solid-phase extraction (MISPE). Final analysis was performed by liquid chromatography-tandem mass spectrometry. The performance of this method has been evaluated in fortified tap and sewage water in terms of recovery, precision, linearity, and method quantification limit. Recovery for all compounds ranged in all matrices between 84 and 116% with intra-day R.S.D. values below 11.5%. Matrix effect evaluation demonstrated that even complex sample matrixes, such as pond or sewage water did not showed significant ion suppression/enhancement compared to tap water. The performance of the method was further emphasized by the study of pond water, which receives treated water from a sewage treatment plant in south Sweden. Raw sewage and treated water were also tested. In those samples, all acidic pharmaceuticals were detected in concentration above method quantification limits ranging from 5.1 to 5153.0 ng L−1.  相似文献   

11.
A series of novel tetramethylguanidinium ionic liquids and hexaalkylguanidinium ionic liquids have been synthesized based on 1,1,3,3‐tetramethylguanidine. The structures of the ionic liquids were confirmed by 1H NMR spectroscopy and mass spectrometry. A green guanidinium ionic liquid based microwave‐assisted extraction method has been developed with these guanidinium ionic liquids for the effective extraction of Praeruptorin A from Radix peucedani. After extraction, reversed‐phase high‐performance liquid chromatography with UV detection was employed for the analysis of Praeruptorin A. Several significant operating parameters were systematically optimized by single‐factor and L9 (34) orthogonal array experiments. The amount of Praeruptorin A extracted by [1,1,3,3‐tetramethylguanidine]CH2CH(OH)COOH is the highest, reaching 11.05 ± 0.13 mg/g. Guanidinium ionic liquid based microwave‐assisted extraction presents unique advantages in Praeruptorin A extraction compared with guanidinium ionic liquid based maceration extraction, guanidinium ionic liquid based heat reflux extraction and guanidinium ionic liquid based ultrasound‐assisted extraction. The precision, stability, and repeatability of the process were investigated. The mechanisms of guanidinium ionic liquid based microwave‐assisted extraction were researched by scanning electron microscopy and IR spectroscopy. All the results show that guanidinium ionic liquid based microwave‐assisted extraction has a huge potential in the extraction of bioactive compounds from complex samples.  相似文献   

12.
The ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate, abbreviated as [C4tmsim][PF6], was developed as a novel medium for liquid-liquid extraction of lead(II) in water, in which dithizone was used as a metal chelator to form a neutral lead-dithizone complex. Under optimal conditions, the complex was extracted into the [C4tmsim][PF6] phase from aqueous solution and back-extracted with nitric acid solution into the aqueous phase that was used directly for the subsequent determination of Pb. The system using the ionic liquid demonstrated good extraction performance; the extraction and back-extraction efficiencies were 99.8 and 99.7%, respectively, for Pb(II) at 20 microg/L. The above procedure, including the extraction and back-extraction, was used to enrich trace levels of Pb(ll) in a relatively large volume of water samples (1000 mL water), and an enrichment factor of 400 was obtained. The enrichment coupled with graphite furnace atomic absorption spectrometry was successfully applied to the determination of Pb in water. The calibration graph was linear at levels near the detection limits up to > or = 100 ng/L Pb(II). The limits of quantitation and detection for lead in real water samples were 2.5 and 1.0 ng/L, respectively. Lead recoveries of 96.2-103.8% from spiked samples demonstrate the accuracy of the proposed method.  相似文献   

13.
The aim of the present work is combination of the advantages of magnetic solid phase extraction (MSPE) and dispersive liquid phase microextraction (DLLME) followed by filtration-based phase separation. A new pretreatment method was developed for trace determination of megestrol acetate and levonorgestrel by liquid chromatography/ultraviolet detection in biological and wastewater samples. After magnetic solid phase extraction, the eluent of MSPE was used as the disperser solvent for DLLME. Emulsion resulted from DLLME procedure was passed through the in-line filter for phase separation. Finally the retained analytes in the filter was washed with mobile phase of liquid chromatography and transferred to the column for separation. This approach offers the preconcentration factors of 3680 and 3750 for megestrol acetate and levonorgestrel, respectively. This guarantees determination of the organic compounds at trace levels. The important parameters influencing the extraction efficiency were studied and optimized. Under the optimal extraction conditions, a linear range of 0.05–50 ng mL−1 (R2 > 0.998) and limit of detection of 0.03 ng mL−1 were obtained for megestrol acetate and levonorgestrel. Under optimal conditions, the method was successfully applied for determination of target analytes in urine and wastewater samples and satisfactory results were obtained (RSDs < 6.8%).  相似文献   

14.
Fabric phase sorptive extraction (FPSE) is a new, yet very promising member of the sorbent-based sorptive microextraction family. It has simultaneously improved both the extraction sensitivity and the speed of the extraction by incorporating high volume of sol–gel hybrid inorganic–organic sorbents into permeable fabric substrates. The advantages of FPSE have been investigated for the determination of four non-steroidal anti-inflammatory drugs, ibuprofen, naproxen, ketoprofen and diclofenac, in environmental water samples in combination with gas chromatography–mass spectrometry. Initially, the significance of several parameters affecting FPSE: sorbent chemistry, matrix pH and ionic strength were investigated using a mixed level factorial design (31 × 22). Then, other important parameters e.g., sample volume, extraction kinetics, desorption time and volume were also carefully studied and optimized. Due to the high sorbent loading on the FPSE substrate in the form of ultra-thin coating and the open geometry of the microextraction device, higher mass transfer of the target analytes occurs at a faster rate, leading to high enrichment factors in a relatively short period of time (equilibrium times: 45–100 min). Under optimal operational conditions, the limits of detection (S/N = 3) were found to be in the range of 0.8 ng L−1 to 5 ng L−1. The enrichment factors ranged from 162 to 418 with absolute extraction efficiencies varied from 27 to 70%, and a good trueness (82–116% relative recoveries) indicating that the proposed method can be readily deployed to routine environmental pollution monitoring. The proposed method was successfully applied to the analysis of target analytes in two influent and effluent samples from a wastewater treatment plant and two river water samples in Spain.  相似文献   

15.
Wang  Xia  Xu  Qing-Cai  Cheng  Chuan-Ge  Zhao  Ru-Song 《Chromatographia》2012,75(17):1081-1085

In this paper, a novel mixed ionic liquids-dispersive liquid–liquid microextraction method was developed for rapid enrichment and determination of environmental pollutants in water samples. In this method, two kinds of ionic liquids, hydrophobic ionic liquid and hydrophilic ionic liquid, were used as extraction solvent and disperser solvent, respectively. DDT and its metabolites were used as model analytes and high-performance liquid chromatography with ultraviolet detector for the analysis. Factors that may affect the extraction recoveries, such as type and volume of extraction solvent (hydrophobic ionic liquid) and disperser solvent (hydrophilic ionic liquid), extraction time, sample pH and ionic strength, were investigated and optimized. Under the optimum conditions, the linear range was 1–100 μg L−1, limits of detection could reach 0.21–0.49 μg L−1, and relative standard deviation was 6.01–8.48 % (n = 7) for the analytes. Satisfactory results were achieved when the method was applied to analyze the target pollutants in environmental water samples with spiked recoveries over the range of 85.7–106.8 %.

  相似文献   

16.
An analytical method based on dispersive solid‐phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass–mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4‐ to 48.7‐fold (theoretical enrichment factor was 50‐fold). The detection limits of pesticides were 0.01~0.77 μg/kg. The linear range was 0.005–0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high‐performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site.  相似文献   

17.
Core–shell magnetic carbon microspheres were synthesized by a simple hydrothermal method and used as a novel magnetic solid‐phase extraction adsorbent for the sensitive determination of polybrominated diphenyl ethers in environmental water samples. Gas chromatography with negative chemical ionization mass spectrometry was adopted for the detection. Box–Behnken design was used to investigate and optimize important magnetic solid‐phase extraction parameters through response surface methodology. Under the optimal conditions, low limits of detection (0.07–0.17 ng·L?1), a wide linear range (1–1000 ng·L?1), and good repeatability (0.80–4.58%) were achieved. The developed method was validated with several real water samples, and satisfactory results were obtained in the range of 72.8–97.9%. These results indicated that core–shell magnetic carbon microspheres have great potential as an adsorbent for the magnetic solid‐phase extraction of polybrominated diphenyl ethers at trace levels from environmental water samples.  相似文献   

18.

In this study, the extraction of lipophilic wood extractives from dissolving pulp samples using ionic liquid–liquid extraction and a two phase hollow fibre supported liquid membrane was investigated. Ionic liquids are capable of dissolving a range of organic and polymeric compounds and are biodegradable, with a negligible vapour pressure. Pulp samples were dissolved in a suitable amount of molten 1-butyl-3-methylimidazolium chloride to give 5 % cellulose solution. Pure cellulose was regenerated by adding water and filtered off. The ionic liquid-aqueous filtrate was first extracted for lipophilic extractives using liquid–liquid extraction. Then, a two phase hollow fibre supported liquid membrane extraction of lipophilic extractives was performed to extract the derivatized compounds prior to analysis by gas chromatography mass spectrometry. The operational parameters of this sample preparation approach were optimised using sterols and fatty acid methyl esters. The variation of enrichment factors and extraction efficiency with respect to liquid membrane, extraction time, stirring speed and sample pH were observed and used to get the optimal parameters. The approach was used in the analysis of oxygen bleached dissolving pulp samples in which main compounds identified were fatty acids, sterols, fatty alcohols, steroid hydrocarbons and ketones. These compounds were similar to those obtained using molecular solvent extraction method, which indicated the absence of chemical reaction between extractives and ionic liquid used.

  相似文献   

19.
Novel poly(ionic liquids) were synthesized and immobilized on prepared magnetic nanoparticles, which were used to extract pesticides from fruit and vegetable samples by dispersive solid‐phase extraction prior to high‐performance liquid chromatography analysis. Compared with monomeric ionic liquids, poly(ionic liquids) have a larger effective contact area and higher viscosity, so they can achieve higher extraction efficiency and be used repeatedly without a decrease in analyte recovery. The immobilized poly(ionic liquids) were rapidly separated from the sample matrix, providing a simple approach for sample pretreatment. The nature and volume of the desorption solvent and amount of poly(ionic liquid)‐modified magnetic material were optimized for the extraction process. Under optimum conditions, calibration curves were linear (R2 > 0.9988) for pesticide concentrations in the range of 0.100–10.000 μg/L. The relative standard deviations for repeated determinations of the four analytes were 2.29–3.31%. The limits of detection and quantification were 0.29–0.88 and 0.97–2.93 μg/L, respectively. Our results demonstrate that the developed poly(ionic liquid)‐modified material is an effective absorbent to extract pesticides from fruit and vegetable samples.  相似文献   

20.
张明  唐访良  俞雅雲  陈峰  徐建芬  叶永根 《色谱》2014,32(5):472-476
建立了固相萃取-超高效液相色谱-电喷雾串联三重四极杆质谱联用技术分析水中16种全氟有机化合物的高通量检测方法。样品经WAX固相萃取柱富集和净化后,采用Waters ACQUITY UPLCTM BEH C18色谱柱,含2 mmol/L乙酸铵的甲醇和含2 mmol/L乙酸铵的水作为流动相进行梯度洗脱,质谱采用电喷雾负离子电离,多反应监测模式检测。16种全氟有机化合物在0.5~100 μg/L或1.0~100 μg/L浓度范围内线性关系良好,相关系数为0.9987~0.9999,方法的检出限为0.06~0.46 ng/L;高、中、低3个添加水平的回收率为67.6%~103%,相对标准偏差为2.94%~12.0%。结果表明,该方法灵敏、准确且检测范围广,分析速度快,是一种适于实际水样中全氟有机化合物检测分析的方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号