首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 828 毫秒
1.
In this study, for the first time, a deep eutectic solvent-based microwave-assisted extraction was combined with ionic liquid–based temperature controlled liquid phase microextraction for the extraction of several aflatoxins from cheese samples. Briefly, the analytes are extracted from cheese sample (3 g) into a mixture of 1.5 mL choline chloride:ethylene glycol deep eutectic solvent and 3.5 mL deionized water by exposing to microwave irradiations for 60 s at 180 W. The liquid phase was taken and mixed with 55 μL 1-hexyl-3-methylimidazolium hexafluorophosphate. By cooling the solution in the refrigerator centrifuge, a turbid state was obtained and the analytes were extracted into the ionic liquid droplets. The analytes were determined by high-performance liquid chromatography equipped with fluorescence detector. Low limits of detection (9–23 ng kg–1) and quantification (30–77 ng kg–1), high extraction recovery (66%–83%), acceptable enrichment factor (40–50), and good precision (relative standard deviations ≤ 5.2%) were obtained using the offered approach. These results reveal the high extraction capability of the method for determination of aflatoxins in the cheese samples. In this method, there was no need for organic solvents and it can be considered as green extraction method.  相似文献   

2.
Herein, a modified quick, easy, cheap, effective, rugged, and safe extraction was developed based on deep eutectic solvent for the extraction of several pesticides from canola oil samples. In this work, first, different sorbents were selected to remove the sample interferences, and the composition of the sorbents was optimized by simplex centroid design. The extracted analytes were more concentrated by solidification of floating deep eutectic solvent droplet-dispersive liquid–liquid microextraction. Low limits of detection (0.15–0.23 ng/g) and quantification (0.49–0.76 ng/g), high extraction recoveries (74–87%) and enrichment factors (224–263), and good repeatability (relative standard deviation equal to or less than 5.1 and 4.7% for intra- and interday precisions, respectively) were achieved using the proposed method. The suggested approach was used for the quantification of the analytes in different canola oil samples. Additionally, the effects of microwave irradiations exposure and sonication in decontamination of the samples were evaluated. In this method, there was no need for centrifugation and toxic solvents. Also, effective extraction of the analytes and minimizing interferences were achieved through the use of various sorbents.  相似文献   

3.
In this study, a green mode of solidification of floating organic droplet – based dispersive liquid–liquid microextraction has been developed for the extraction of 16 polycyclic aromatic hydrocarbons from honey samples before their determination by gas chromatography–mass spectrometry. In this method, an appropriate volume of menthol:decanoic acid deep eutectic solvent (as an extraction solvent) is added on a sugar cube (as a disperser agent). In the following, the cube is released into the diluted honey sample placed in a tube. After manual shaking a cloudy state is obtained as a result of dispersing the extraction solvent droplets throughout the sample solution and the analytes are extracted into them. After placing the tube in an ice bath, the droplet of the extractant is solidified on the top of the solution. This drop is taken and after dissolving in acetonitrile, an aliquot of the solution is injected into the separation system. Under optimum conditions, the suggested approach had high extraction recoveries (76–93%) and enrichment factors (380–465), low limits of detection (14–52 ng/kg) and quantification (47–173 ng/kg), and satisfactory repeatability (relative standard deviation ≤ 9%).  相似文献   

4.
In this work, a magnetic β‐cyclodextrin polymer was successfully prepared and used as an adsorbent for the magnetic solid‐phase extraction of six benzoylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, flufenoxuron, and chlorfluazuron) from honey, tomato, and environmental water samples. The influence of the main experimental conditions on the extraction was studied. Under the optimized conditions, the β‐cyclodextrin polymer@Fe3O4 showed an excellent extraction performance for the benzoylurea insecticides. A good linearity was obtained for the analytes in the range of 3.0–800 ng/g for honey samples, 0.3–160 ng/g for tomato samples, and 0.1–80.0 ng/mL for water samples, with the correlation coefficients above 0.9998. Satisfactory repeatabilities were achieved, with the relative standard deviations less than 5.7%. The limits of detection (S/N = 3) of the method for the benzoylurea insecticides were 0.2–0.8 ng/g for honey samples, 0.04–0.10 ng/g for tomato samples, and 0.02–0.05 ng /mL for water samples. The method was successfully used for the determination of the six benzoylurea insecticides residues in honey, tomato, and environmental water samples with a satisfactory result.  相似文献   

5.
A simple, environmentally benign, and rapid method based on temperature‐controlled liquid–liquid microextraction using a deep eutectic solvent was developed for the simultaneous extraction/preconcentration of diazinon and fenitrothion. The method involved the addition of deep eutectic solvent to the aqueous sample followed by heating the mixture in a 75°C water bath until the solvent was completely dissolved in the aqueous phase. Then, the resultant solution was cooled in an ice bath and a cloudy solution was formed. Afterward, the mixture was centrifuged and the enriched deep eutectic solvent phase was analyzed by high‐performance liquid chromatography with ultraviolet detection for quantification of the analytes. The factors affecting the extraction efficiency were optimized. Under the optimized extraction conditions, the limits of detection for diazinon and fenitrothion were 0.3 and 0.15 μg/L, respectively. The calibration curves for diazinon and fenitrothion exhibited linearity in the concentration range of 1–100 and 0.5–100 μg/L, respectively. The relative standard deviations for five replicate measurements at 10.0 μg/L level of analytes were less than 2.8 and 4.5% for intra‐ and interday assays, respectively. The developed method was successfully applied to the determination of diazinon and fenitrothion in water and fruit juice samples.  相似文献   

6.
A free dispersive method, air-assisted in situ deep eutectic solvent decomposition followed by the solidification of floating organic droplets liquid-liquid microextraction was indicated in this study. This technique was utilized to simultaneously ascertain some azole antifungal drugs prior to high-performance liquid chromatography. In this research, a quasi-hydrophobic deep eutectic solvent was formed from tetrabutylammonium bromide and 1-dodecanol as an organic solvent at a 1:2 molar ratio. The synthesized deep decomposition in the sample solution caused in situ dispersion of extraction solvent and analytes. Air-assisted enhanced a dispersion condition in the sample solution. 1-Dodecanol as a green option was replaced with typical extraction solvents providing the advantages of a suitable freezing point near room temperature and low density. The effect of important analytical parameters on the extraction recovery of analytes was assessed. Under these optimal conditions, the limits of detection and the limits of quantitation determined were in the range of 0.5–2.8 and 1.5–9 μg/L, for water, urine and plasma samples, respectively. The intra-day and inter-day relative standard deviations (n = 5) were calculated to be 2.9–4.6 and 4.2–8.9%, respectively. The results represented the effectiveness of the developed method for the extraction and determination of analytes in biological samples.  相似文献   

7.
A stir bar sorptive extraction method coupled with deep eutectic solvent based solidification of floating organic droplets–dispersive liquid–liquid microextraction has been used for the simultaneous derivatization and extraction of some acidic pesticides in tomato samples. In this method, initially the analytes are adsorbed on a coated stir bar from tomato juice filled in a narrow tube. After extraction, the stir bar is removed and a water–miscible deep eutectic solvent is used to elute the analytes. Afterward, a derivatization agent and a water–immiscible deep eutectic solvent (as an extraction solvent) with melting point near to room temperature are added to the obtained eluant at µL–levels and the obtained mixture is rapidly injected into deionized water. Under the optimum conditions, the introduced method indicated high enhancement (1543–3353) and enrichment (2530–2999) factors, low limits of detection (7–14 ng/L) and quantification (23–47 ng/L), good linearity (r2 ≥ 0.9982), and satisfactory repeatabilities (relative standard deviation ≤12% for intra– and inter–day precisions at a concentration of 100 ng/L of each analyte). Finally, the proposed method was applied in analysis of the analytes in tomato samples.  相似文献   

8.
A green and novel deep eutectic solvent modified graphene was prepared and used as a neutral adsorbent for the rapid determination of sulfamerazine in a river water sample by pipette‐tip solid‐phase extraction. Compared with conventional graphene, deep eutectic solvent modified graphene can change the surface of graphene with wrinkled structure and higher selective extraction ability. The properties of deep eutectic solvent modified graphene and graphene were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Static adsorption showed deep eutectic solvent modified graphene had a higher adsorption ability (18.62 mg/g) than graphene. Under the optimum conditions, factors such as kinds of washing solvents and elution solvents and volume of elution solvent were evaluated. The limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of sulfamerazine were in the range of 91.01–96.82% with associated intraday relative standard deviations ranging from 1.63 to 3.46% and interday relative standard deviations ranging from 0.68 to 3.84%. Deep eutectic solvent modified graphene showed satisfactory results (recovery was 95.38%) and potential for rapid purification of sulfamerazine in river water sample in combination with the pipette‐tip solid‐phase extraction method.  相似文献   

9.
In this study, corn stalk was used to synthesize a magnetic adsorbent by pyrolysis together with KHCO3 as the chemical activator and iron(III) salt as the magnetic reagent. The characterization by scanning electron microscopy, transmission electron microscopy and N2 adsorption–desorption analysis showed that the magnetic carbon adsorbent had a structure of hierarchical pores with a high specific surface area. To evaluate its adsorption performance, the adsorbent was used for the extraction of carbamates pesticides (propoxur, isoprocarb and fenobucarb) from water and zucchini samples before high‐performance liquid chromatography analysis. The result showed that the adsorbent had a good adsorption capability for the analytes. Under the optimized conditions, a good linearity for the analytes existed in the range of 0.1–100.0 ng/mL for water samples and 0.5–100.0 ng/g for zucchini samples with the correlation coefficients of 0.9992–0.9998. The limits of detection for the analytes at a signal to noise ratio of 3 were 0.03 ng/mL for water samples and 0.20–0.50 ng/g for zucchini samples.  相似文献   

10.
An in-situ formed polymer–based dispersive solid phase extraction in combination with solidification of floating organic droplet-based dispersive liquid–liquid microextraction was developed for the extraction of neonicotinoid pesticides from milk samples. The extracted analytes were determined using high-performance liquid chromatography–diode array detector. In this approach, after precipitating the proteins of milk using a zinc sulfate solution, the supernatant phase (containing sodium chloride) was transferred into another glass test tube, and a homogenous solution of polyvinylpyrrolidone and a suitable water-miscible organic solvent was rapidly injected into it. By this step, the polymer particles were re-produced and the analytes were extracted onto the sorbent surface. In the following step, the analytes were eluted with an appropriate organic solvent to use in the following solidification of floating organic droplet-based dispersive liquid–liquid microextraction step that was done to acquire the low limits of detection. Under the optimized conditions, satisfactory results consisting of low limits of detection (0.13–0.21 ng/ml) and quantification (0.43–0.70 ng/ml), high extraction recoveries (73%–85%), and enrichment factors (365–425), and good repeatability (relative standard deviations equal or less than 5.1% and 5.9% for intra- and inter-day precisions, respectively) were obtained.  相似文献   

11.
Based on the solidification of a hydrophobic deep eutectic solvent in air‐assisted liquid phase microextraction combined with gas chromatography and mass spectrometry, a green and sustainable microextraction technique was developed for extracting, separating, and detecting organophosphorus flame retardants in aqueous samples. In this study, some strategies were considered for overcoming or improving the challenges of conventional solvent microextraction procedures. In addition, a hydrophobic deep eutectic solvent with a freezing point near the ambient temperature was employed as an extraction phase, the dispersive solvent was substituted by the syringe pump process, and the centrifugation step was omitted by using salting‐out phenomenon. Further, the effect of the main independent variables was evaluated by using the chemometric methods in order to maximize the extraction efficiency of the procedure. Under optimal conditions, the calibration model was linear in the range of 0.01–25.0 µg/L. Limits of detection and quantitation were assessed at the concentration levels of 2–23 and 9–65 ng/L, respectively. The precision involving repeatability and reproducibility was evaluated by estimating the relative standard deviation, the levels of which were <6.6 and <8.7%, respectively. The applicability of the method was successfully evaluated by analyzing the target analytes in real aqueous samples, which illustrated satisfactory recoveries (95–104.61%).  相似文献   

12.
A new green miniaturized quick, easy, cheap, effective, rugged, and safe approach was developed and used for the extraction of multiclass 16 pesticides in milk before gas chromatography analysis. The miniaturization of method reduced the consumption of chemical reagents and samples. Magnetic three-dimensional graphene was used as sorbent in the clean-up step. Choline chloride:lactic acid (1:2) natural deep eutectic solvent was used as desorption solvent. Temperature-assisted solidification of floating menthol drop was executed for preconcentration of analytes. The method parameters including sorbent, desorption solvent, sorption and desorption times, menthol amount, pH, and ionic strength were optimized. The limit of quantification and linear range were 0.03–0.38 and 0.03–250 μg/kg, respectively. The accuracy was assessed by recovery evaluation at the spike levels of 50 and 100 μg/kg, in the range of 61–119%, with relative standard deviations within 2.1–18.2%. The method was applied to the analysis of pasteurized low and high-fat bovine milk, and various pesticide residues were detected in the concentrations range of 1.24–4.68 μg/kg. Finally, the greenness of the procedure was evaluated using the Analytical Eco-Scale. This work represents the first application of hybrid miniaturized extraction/preconcentration using a natural deep eutectic solvent and menthol to analyze pesticides.  相似文献   

13.
By monomer-mediated in-situ growth synthesis strategy, with hydroquinone and 1,3,5-tris(4-aminophenyl)benzene as monomers, a core-shell magnetic porous organic polymer was synthesized through a simple azo reaction. Based on this, a magnetic solid-phase extraction–high-performance liquid chromatography–fluorescence detection method was proposed for the analysis of fluoroquinolones in a honey sample. With ofloxacin, ciprofloxacin, enrofloxacin, lomefloxacin, and difloxacin as target analytes, factors affecting the extraction efficiency had been optimized. The LODs were 1.5–5.4 ng/L (corresponding to 0.23–0.81 μg/kg in honey). The linear range was 0.005–20 μg/L for difloxacin, 0.01–20 μg/L for ofloxacin, ciprofloxacin and lomefloxacin, and 0.02–20 μg/L for enrofloxacin. The enrichment factor was 84.4–91.7-fold with a high extraction efficiency of 84.4–91.7%. The method was assessed by the analysis of target fluoroquinolones in honey samples, and the recoveries for the spiked samples were 79.3–95.8%. The results indicated that the established magnetic solid-phase extraction–high-performance liquid chromatography–fluorescence detection method is efficient for the analysis of trace fluoroquinolones in honey.  相似文献   

14.
A three‐phase hollow‐fiber liquid‐phase microextraction based on deep eutectic solvent as acceptor phase was developed and coupled with high‐performance capillary electrophoresis for the simultaneous extraction, enrichment, and determination of main active compounds (hesperidin, honokiol, shikonin, magnolol, emodin, and β,β′‐dimethylacrylshikonin) in a traditional Chinese medicinal formula. In this procedure, two hollow fibers, impregnated with n‐heptanol/n‐nonanol (7:3, v/v) mixture in wall pores as the extraction phase and a combination (9:1, v/v) of methyltrioctylammonium chloride/glycerol (1:3, n/n) and methanol in lumen as the acceptor phase, were immersed in the aqueous sample phase. The target analytes in the sample solution were first extracted through the organic phase, and further back‐extracted to the acceptor phase during the stirring process. Important extraction parameters such as types and composition of extraction solvent and deep eutectic solvent, sample phase pH, stirring rate, and extraction time were investigated and optimized. Under the optimal conditions, detection limits were 0.3–0.8 ng/mL with enrichment factors of 6–114 for the analytes and linearities of 0.001–13 μg/mL (r2 ≥ 0.9901). The developed method was successfully applied to the simultaneous extraction and concentration of the main active compounds in a formula of Zi‐Cao‐Cheng‐Qi decoction with the major advantages of convenience, effectiveness, and environmentally friendliness.  相似文献   

15.
Considering that the determination of pyrethroid residues is of value for the safety of food, a new poly(ionic liquid)‐functionalized magnetic mesoporous nanoparticle was designed and used as an adsorbent in magnetic solid‐phase extraction for the enrichment of eight pyrethroids. The porous structure and large surface area of the mesoporous silica shell endow the adsorbent with abundant binding sites. In contrast to the reported poly(ionic liquids) with only one kind of functional group in the cationic part, the new poly(ionic liquids) with mixed cyano and phenyl groups in cationic part matched the chemical structure of the analytes to improve extraction efficiency. Under the optimum conditions, an effective method was established for the determination of eight pyrethroids in apples. Adsorption equilibrium can be quickly reached in 1 min, greatly decreasing the extraction time. The linearity range was found to be 10–200 ng/g, and the detection limits ranged from 0.24 to 1.99 ng/g. Recoveries of analytes in apple samples ranged from 87.3 to 119.0%, with relative standard deviations varying in the range of 3–21.2% (intraday) and 0.3–15.2% (interday). The results indicate that the proposed method is a good candidate for pyrethroid residues in apple samples.  相似文献   

16.
In this study, a new two–step extraction procedure based on the combination of a modified quick, easy, cheap, effective, rugged, and safe extraction method with a deep eutectic solvent based microwave‐assisted dispersive liquid–liquid microextraction has been developed for the extraction of multiclass pesticides in tomato samples before their analysis by gas chromatography with flame ionization detection. In this method, initially, an aliquot of tomato is crushed and diluted with deionized water. The mixture is then passed through a filter paper and its residue and aqueous phase are separated. Afterwards, acetonitrile as an extraction/disperser solvent is passed through the filter paper containing the refuse. The analytes remained in the refuse are extracted into the acetonitrile and then the obtained extract is mixed with a deep eutectic solvent. The obtained mixture is injected into the tomato juice and placed in a microwave oven for 15 s. Consequently, a cloudy state is formed and the extractant containing the analytes are sedimented at the bottom of the tube after centrifugation. Finally, 1 μL of the sedimented phase is removed and injected into the separation system. Under the optimum conditions, limits of detection and quantification were in the ranges of 0.42–0.74 and 1.4–2.5 ng/g, respectively.  相似文献   

17.
In situ synthesis of a deep eutectic solvent and homogeneous liquid–liquid microextraction performed in a narrow bore tube was developed for efficient extraction of irgaphos 168 and irganox 1010 in doogh and water samples packed in polypropylene packages. First, pH of the aqueous sample solutions containing the analytes is adjusted at 9. Then a hydrogen bond acceptor (choline chloride) and a hydrogen bond donor (oleic acid) are dissolved in the solution and vortexed to obtain a homogeneous solution. The solution is filled into a narrow bore tube, in which its bottom was clogged by a septum. Then hydrochloric acid solution is injected into the solution by a syringe. The tube is placed in an ultrasonic bath. During this step, the droplets of choline chloride:oleic acid deep eutectic solvent are produced. The method indicated high enrichment factor (435 for irgaphos 168 and 488 for irganox 1010), low limits of detection (0.03 and 0.09 ng/mL for irgaphos 168 and irganox 1010, respectively) and quantification (0.13 and 0.29 ng/mL for irgaphos 168 and irganox 1010), good recovery (74 and 83% for irgaphos 168 and irganox 1010, respectively), and satisfactory repeatabilities (relative standard deviations ≤12%) can be obtained using the developed method.  相似文献   

18.
A facile headspace single drop microextraction method was developed using deep eutectic solvent‐based magnetic bucky gel as the extraction solvent for the first time. The hydrophobic magnetic bucky gel was formed by combining choline chloride/chlorophenol deep eutectic solvent and magnetic multiwalled carbon nanotube nanocomposite. Magnetic susceptibility, high viscosity, high sorbing ability, and tunable extractability of organic analytes are the desirable advantages of the prepared gel. Using a rod magnet as a suspensor in combination with the magnetic susceptibility of the prepared gel resulted in a highly stable droplet. This stable droplet eliminated the possibility of drop dislodgement. The prepared droplet made it possible to complete the extraction process in high temperatures and elevated agitation rates. Furthermore, using larger micro‐droplet volumes without any operational problems became possible. These facts resulted in shorter sample preparation time, higher sensitivity of the method, and lower detection limits. Under the optimized conditions, an enrichment factor of 520–587, limit of detection of 0.05–0.90 ng/mL, and linearity range of 0.2–2000 ng/mL (coefficient of determination = 0.9982–0.9995) were obtained. Relative standard deviations were < 10%. This method was successfully coupled with gas chromatography and used for the determination of benzene, toluene, ethylbenzene, and xylene isomers as harmful volatile organic compounds in water and urine samples.  相似文献   

19.
In this study, a gas‐assisted dispersive liquid‐phase microextraction method using a deep eutectic solvent as the extraction solvent combined with gas chromatography and flame ionization detection was developed for the extraction and determination of some pesticide residues in vegetable and fruit juice samples. In this method, choline chloride and 4‐chlorophenol at a molar ratio of 1:2 were mixed. By heating and vortexing, a clear, water‐immiscible, and homogeneous liquid was formed. The obtained deep eutectic solvent was added to an aqueous solution of the analytes in a conical test tube. Air was bubbled into the aqueous solution and a cloudy solution was obtained. During this step, the analytes were extracted into the fine droplets of the extraction solvent. After centrifugation, an aliquot of the settled phase was injected into the separation system. Under the optimum extraction conditions, enrichment factors, and extraction recoveries were obtained in the ranges of 247–355 and 49–71%, respectively. The obtained values for the limits of detection and quantification were in the ranges of 0.24–1.4 and 0.71–4.2 μg/L, respectively. The proposed method is simple, fast, efficient, and inexpensive.  相似文献   

20.
A new type of adsorbent composed of magnetic three‐dimensional graphene coated with silver nanoparticles was synthesized by an electroless technique and used in the magnetic solid‐phase extraction of selected pesticides (fenitrothion, chlorpyrifos, and hexaconazole) before gas chromatography with a micro‐electron capture detector. The adsorbent was characterized using Fourier‐transform infrared spectroscopy, X‐ray diffraction, vibrating sample magnetometry, and field‐emission scanning electron microscopy. The important extraction parameters such as pH, adsorbent dose, extraction time, and desorption conditions were investigated. Under the optimal conditions, the analytical figures of merit were obtained as: linear dynamic range of 0.1–5 ng/g with determination coefficients of 0.991–0.996; limit of detection of 0.07–0.13 ng/g; limit of quantification of 0.242–0.448 ng/g; and the intraday and interday relative standard deviations (= 5 ng/g, = 3) were 3.8–8.7 and 6.6–8.9%, respectively. The developed method was successfully applied for analysis of the selected pesticides in tomato and grape with extraction recoveries in the range of 72.8–109.6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号