首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A pencil graphite electrode (PGE) electrodeposited by a polypyrrole conducting polymer doped with tartrazine (termed as PGE/PPy/Tar) was prepared and used as a zinc (II) solid-state ion-selective electrode. For the preparation of the zinc sensor electrode, electrodeposition of a polypyrrole nanofilm was carried out potentiostatically (E app?=?0.75 V vs SCE) in a solution containing 0.010 M pyrrole and 0.001 M tartrazine trisodium salt. A pencil graphite and Pt wire were used as working and auxiliary electrodes, respectively. The introduced electrode in the current paper can be fabricated simply and was found to possess high selectivity, exhibited wide working concentration range, sufficiently rapid response, potential stability, and very good sensitivity to Zn (II) ion. The sensor electrode showed a linear Nernstian response over the range of 1.0?×?10?5 to 1.0?×?10?1 M with a slope of 28.23 mV per decade change in zinc ion concentration. A detection limit of 8.0?×?10?6 M was obtained. The optimum pH working of the electrode was found to be 5.0.  相似文献   

2.
An electrochemical label-free immunosensor based on a biotinylated single-chain variable fragment (Sc-Fv) antibody immobilized on copolypyrrole film is described. An efficient immunosensor device formed by immobilization of a biotinylated single-chain antibody on an electropolymerized copolymer film of polypyrrole using biotin/streptavidin system has been demonstrated for the first time. The response of the biosensor toward antigen detection was monitored by surface plasmon resonance (SPR) and electrochemical analysis of the polypyrrole response by differential pulse voltammetry (DPV). The composition of the copolymer formed from a mixture of pyrrole (py) as spacer and a pyrrole bearing a N-hydroxyphthalimidyl ester group on its 3-position (pyNHP), acting as agent linker for biomolecule immobilization, was optimized for an efficient immunosensor device. The ratio of py:pyNHP for copolymer formation was studied with respect to the antibody immobilization and antigen detection. SPR was employed to monitor in real time the electropolymerization process as well as the step-by-step construction of the biosensor. FT-IR demonstrates the chemical copolymer composition and the efficiency of the covalent attachment of biomolecules. The film morphology was analyzed by electron scanning microscopy (SEM).Results show that a well organized layer is obtained after Sc-Fv antibody immobilization thanks to the copolymer composition defined with optimized pyrrole and functionalized pyrrole leading to high and intense redox signal of the polypyrrole layer obtained by the DPV method. Detection of specific antigen was demonstrated by both SPR and DPV, and a low concentration of 1 pg mL−1 was detected by measuring the variation of the redox signal of polypyrrole.  相似文献   

3.
We report on a graphite electrode onto which polypyrrole was electrodeposited and then doped with chromate ion. This electrode can serve as a Cr(VI)-selective solid-state electrode. Electropolymerization of pyrrole was performed potentiostatically at 0.80?V (vs. SCE) using battery graphite as the working electrode in a solution containing 0.10?M of pyrrole and 20?mM of chromate. A platinum wire was used as an auxiliary electrode. The new electrode displays high selectivity, a very wide dynamic range, a sufficiently fast response time and a good shelf lifetime. It shows a linear Nernstian response over 1.0?×?10?6 to 1.0?×?10?1?M concentration range (with a slope of 26.55?±?0.20?mV per log of concentration). The detection limit is 0.5?μM, and the pH optimum is 7.0.
Figure
A highly selective solid state Cr(VI) ion-selective electrode based on polypyrrole conducting polymer was prepared. The introduced Cr(VI) micro sensor electrode exhibited linear response over a wide working concentration range with a high regression coefficient and a near Nernstian slope. The SEM image of PPy/CrO4 thin film shows unevenly distributed nanoparticles.  相似文献   

4.
We describe herein the synthesis and electrochemical polymerization of a viologen monomer functionalized by a biotin group and the use of its redox properties for the impedimetric sensing of protein binding. The electrochemical oxidation of the pyrrole group at 0.85 V in CH3CN led to a biotinylated polypyrrole film allowing the successive anchoring of an avidin layer and a biotinylated cholera toxin layer. EIS performed at ?0.45 V/SCE without redox probe in solution showed the specific immobilization of the anti-cholera toxin antibody.  相似文献   

5.
The avidin-biotin assay was investigated by an electrochemical procedure based on the chemical reaction between cysteine containing a thiol group and N-iodoacetyl-N-biotinylhexylenediamine (IB). In the presence of avidin and biotin this reaction, whereby the thiol group combines with IB, is controlled because IB has a biotin part; that is, avidin and biotin are detected indirectly by measurement of iodide ion or cysteine. To achieve a high sensitivity of detection, Hg(II) was introduced as a marker that interacts with cysteine and the oxidation peak from Hg(0) to Hg(II) was measured. The sensitivity of detection of avidin was at the level of 10−9 M. The relative standard deviation at 1 × 10−8 M avidin was 4.8% (n = 5). On the other hand, a response curve to detect biotin was obtained by the competitive reaction between IB and biotin for the limited binding sites of avidin. The change in peak current enables the detection of biotin at the level of 10−9 M. This method has the advantage that it is not necessary to separate free IB from bound IB.  相似文献   

6.
In this study, a potentiometric sensor based on a pencil graphite electrode (PGE) coated with polypyrrole doped with uranyl zinc acetate (termed PGE/PPy/U) have been prepared for potentiometric determination of uranyl in aqueous solutions. Electropolymerization reaction for preparing of U(VI) sensor electrode was carried via applying a constant current of 1.0 mA on PGA working electrode in a solution containing 8.0 mM pyrrole and 0.8 mM ZnUO2(CH3COO)4 salt. The constructed electrode displayed a linear and near Nernstian response (22.60 ± 0.40 mV/decade) to U(VI) ions in the concentration range of 1.0 × 10?6–1.0 × 10?2 M. A detection limit of 6.30 × 10?7 M and a fast response time (≤12 s) was observed during measurements. The working pH range of the electrode was 4.0–8.0 and lifetime of the sensor was at least 60 days. The electrode revealed good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The introduced uranyl electrode was used for measurement of U(VI) ion in real samples without any serious inferences from other ions.  相似文献   

7.
The Cu (II) imprinted polymer glassy carbon electrode (GCE/Cu-IP) was prepared by electropolymerization of pyrrole at GCE in the presence of methyl red as a dopant and then imprinting by Cu2+ ions. This electrode was applied for potentiometric and voltammetric detection of Cu2+ ion. The potentiometric response of the electrode was linear within the Cu2+ concentration range of 3.9 × 10?6 to 5.0 × 10?2 M with a near-Nernstian slope of 29.0 mV decade?1 and a detection limit of 5.0 × 10?7 M. The electrode was also used for preconcentration anodic stripping voltammetry and results exhibited that peak currents for the incorporated copper species were dependent on the metal ion concentration in the range of 1.0 × 10?8 to 1.0 × 10?3 M and detection limit was 6.5 × 10?9 M. Also the selectivity of the prepared electrode was investigated. The imprinted polymer electrode was used for the successful assay of copper in two standard reference material samples.  相似文献   

8.
Polypyrrole (PPy) is a conducting polymer which can be used for producing different ion-selective electrodes. An iodide-doped (PPy-iodide) was prepared electrochemically by anodic polymerisation of pyrrole in the presence of an iodide ion in an aqueous solution on the surface of a pencil lead. Polymerisation was investigated under galvanostatic conditions. The effects of electropolymerisation conditions on the characteristics of the potential response of the sensor were examined. Concentrations of pyrrole, iodide ions, and conditioning solution plus current density and the time of electropolymerisation were optimised in relation to the slope and linearity of calibration graphs. This electrode showed a Nernstian behaviour of 61.1 mV per decade for I? ion over a wide concentration range from 1.0 × 10?5 M to 1.0 × 10?1 M, with the limit of detection of 9.3 × 10?6 M. The response time of the electrode was from 3–5 s. The selectivity coefficients of the prepared sensors over a wide spectrum of interference anions were also evaluated, revealing that selectivity improves as a result of double-coating with PPy. A similar improvement was observed under lower current density and longer electropolymerisation time. This sensor was applied in the determination of iodide ions using titration potentiometry. This electrode can be used for the determination of iodide in drug preparations.  相似文献   

9.
《Analytical letters》2012,45(16):3038-3049
Abstract

The lead(II) ion selective solid‐contact electrode based on polypyrrole film, covered with a polyvinyl chloride membrane has been prepared. Polypyrrole film was used as a mediating layer of the solid‐contact electrode due to the conductivity. Crown ether has been used as ionophores in polyvinyl chloride cocktail solutions. This solid‐contact electrode based on benzo‐15‐crown‐5 exhibited Nernstian‐response within 30 s response time over concentration range, 1×10?1~5×10?7 M. The selectivity of this electrode to other metal cations was comparatively good. This electrode showed much better results, such as detection range, slope, response time and reproducibility than conventional ion selective electrode and coated wire electrode.  相似文献   

10.
An organically modified sol‐gel electrode using 3‐aminopropyltrimethoxy silane for covalent immobilization of a redox mediator namely toluidine blue has been reported. Cyclic voltammetric characterization of the modified electrode in the potential range of 0.2 V to ?0.6 V exhibited stable voltammetric behavior in aqueous supporting electrolyte with a formal potential of ?0.265 V vs. SCE, corresponding to immobilized toluidine blue. The electrocatalytic activity of the modified electrode when tested towards nitrite ion exhibited a favorable response with the electrocatalytic reduction of nitrite occurring at a reduced potential of ?0.34 V. A good linear working range from 2.94×10?6 M to 2.11×10?3 M with a detection limit of 1.76×10?6 M and quantification limit of 5.87×10?6 M was obtained for nitrite determination. The stable and quick response (4 s) of the modified electrode towards nitrite under hydrodynamic conditions shows the feasibility of using the present sensor in flow systems. Significant improvements in the operational stability by overcoming the leachability problem and repeatability with a relative standard deviation of 1.8% of the TB thin film sensor have been obtained by the strategy of immobilization of the mediator in the sol‐gel matrix.  相似文献   

11.
A novel NH2+ ion implantation‐modified indium tin oxide (NH2/ITO) electrode was prepared. Acid‐pretreated, negatively charged MWNTs were firstly modified on the surface of NH2+ ion implantation electrode, then, positively charged Mb was adsorbed onto MWNTs films by electrostatic interaction. The assembly of MWNTs and Mb was characterized with electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The immobilized Mb showed a couple of quasireversible cyclic voltammetry peaks in pH 7.0 phosphate buffer solution (PBS). The apparent surface concentration of Mb at the electrode surface was 1.06×10?9 mol cm?2. The Mb/MWNTs/NH2/ITO electrode also gave an improved electrocatalytic activity towards the reduction of hydrogen peroxide. The catalysis currents increased linearly to the H2O2 concentration in a wide range from 9×10?7 to 9.2×10?5 M with a correlation coefficient of 0.999. The detection limit was 9.0×10?7 M. The experiment results demonstrated that the modified electrode provided a biocompatible microenvironment for protein and supplied a necessary pathway for its direct electron transfer.  相似文献   

12.
In this study, a potentiometric sensor based on a pencil graphite electrode (PGE) coated with polypyrrole doped with Titan yellow dye (PPy/TY) was prepared for potentiometric determination of magnesium ion in aqueous solutions. The structural characteristics of magnesium sensor electrode (PGE/PPy/TYMg) were studied using scanning electron microscopy and Fourier transform infrared along with energy-dispersive spectroscopy. Under the optimal conditions, the electrode reveals a good Nernstian behavior with slope of 28.27 ± 0.40 mV per decade over the concentration range of 1.0 × 10?5–5.0 × 10?2 M and a detection limit of 6.28 × 10?6 M. The potentiometric response of fabricated electrode toward magnesium ion was found to be independent of the pH of the test solution in the pH range of 4.5–8.0. The electrode showed fast response time (<10 s) and good shelf lifetime (>2 months). The prepared magnesium sensor electrode can also be used as an indicator electrode in potentiometric titration of Mg2+ with EDTA with distinguished end point. The electrode revealed good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The introduced magnesium electrode was used for measurement of Mg2+ ion in real samples without any serious interferences from other ions.  相似文献   

13.
《Analytical letters》2012,45(13):2077-2088
Abstract

An electrochemiluminescence (ECL) method for reduced nicotinamide adenine dinucleotide (NADH) was proposed by immobilizing tris(2,2′‐bipyridyl) ruthenium(II) (Ru(bpy)3 2+) in multiwall carbon nanotubes (MWCNTs)/Nafion composite membrane that was formed on glassy carbon electrode surface. The electrochemical and ECL behaviors of the immobilized Ru(bpy)3 2+ were investigated. The cyclic votammogram of the modified electrode in pH 7.0 phosphate buffer solution showed a couple of redox peaks at +1190 and +1060 mV at 100 mV/s. The composite film had a more open structure and a large surface area allowing faster diffusion of Ru(bpy)3 2+. The presence of MWCNTs resulted in the improved ECL sensitivity and longer‐term stability of the modified electrode. The modified electrode showed a linear response to NADH in the concentration range of 1.0×10?6 to 1.6×10?5 M with a detection limit of 8.2×10?7 M.  相似文献   

14.
This work presents the results obtained on the construction of a potentiometric ion‐selective electrode based on a polypyrrole (PPy) selective membrane to quantify the benzoate ion in nonalcoholic beverages. The electrode modification with benzoate (Benz?1) ion doped‐Ppy was carried out under an imposed potential, while the electrosynthesis optimization was undertaken using the modified Simplex method, such that the film’s sensitivity was maximized toward the benzoate ion. The maximum sensitivity recorded was ?52.02±1.55 mV/decade [Benz?1] using a graphite powder‐araldite resin composite electrode. During the modified electrode’s characterization it was found out that the response and drift were relatively short, namely 2 min and 0.4 mV min?1 respectively, within the 7 to 9 pH range, exhibiting a detection limit of 7×10?4 mol L?1 and a quantification range of 3×10?3 at 10?1 mol L?1. Selectivity coefficients were evaluated with the Matched Potential Method obtaining in all cases values much less than 1. The benzoate concentration in commercially available juices and sweetened beverages was evaluated comparing the results obtained with the proposed ion‐selective electrode and those of HPLC, the usually accepted technique. A statistical analysis of the results led to the conclusion that there exists no meaningful difference between the results obtained with both techniques, which shows the usefulness of the ion‐selective electrode to proceed with the quantification in real samples.  相似文献   

15.
Facile electrical communication between redox-active labeling molecules and electrode is essential in the electrochemical detection of bio-affinity reactions. In this report, nanometer-sized indium tin oxide (ITO) particles were employed in the fabrication of porous thick film electrodes to enhance the otherwise impeded electrochemical activity of redox labels in multi-layered protein films, and to enable quantitative detection of avidin/biotin binding interaction. To carry out the affinity reaction, avidin immobilized on an ITO electrode was reacted with mouse IgG labeled with both biotin and ruthenium Tris-(2,2′-bipyridine) (Ru-bipy). The binding reaction between avidin and biotin was detected by the catalytic voltammetry of Ru-bipy in an oxalate-containing electrolyte. On sputtered ITO thin film electrode, although a single layer of Ru-bipy labeled avidin exhibited substantial anodic current, attaching the label to the outer IgG layer of the avidin/biotin-IgG binding pair resulted in almost complete loss of the signal. However, electrochemical current was recovered on ITO film electrodes prepared from nanometer-sized particles. The surface of the nanoparticle structured electrode was found by scanning electron microscopy to be very porous, and had twice as much surface binding capacity for avidin as the sputtered electrode. The results were rationalized by the assumption of different packing density of avidin inner layer on the two surfaces, and consequently different electron transfer distance between the electrode and Ru-bipy on the IgG outer layer. A linear relationship between electrochemical current and IgG concentration was obtained in the range of 40-4000 nmol L−1 on the nanoparticle-based electrode. The approach can be employed in the electrochemical detection of immunoassays using non-enzymatic redox labels.  相似文献   

16.
《Electroanalysis》2006,18(7):703-711
A simple procedure was developed to prepare a glassy carbon electrode modified with carbon nanotubes (CNTs) and thionin. Abrasive immobilization of CNTs on a GC electrode was achieved by gently rubbing the electrode surface on a filter paper supporting carbon nanotubes, then immersing the GC/CNTs‐modified electrode into a thionin solution (electroless deposition) for a short period of time (5–50 s for MWCNTs and 5–120 s for SWCNTs ). Cyclic voltammograms of the resulting modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range 2–12. The electrochemical reversibility and stability of modified electrode prepared with incorporation of thionin into CNTs film was compared with usual methods for attachment of thionin to electrode surfaces such as electropolymerization and adsorption on the surface of preanodized electrodes. The formal potential of redox couple (E°′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of thionin immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2 and 3.2×10?10 mol cm?2 for MWCNTs and SWCNTs, respectively. The transfer coefficient (α) was calculated to be 0.3 and 0.35 and heterogeneous electron transfer rate constants (Ks) were 65 s?1 and 55 s?1 for MWCNTs/thionin and SWCNTs/thionin‐modified GC electrodes, respectively. The results clearly show a great facilitation of the electron transfer between thionin and CNTs adsorbed on the electrode surface. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of electrodes.  相似文献   

17.
《Electroanalysis》2004,16(15):1271-1278
Four kinds of xanthine oxidase (XOD) based amperometric biosensors were fabricated and their analytical performances were compared. Polypyrrole (PPY)/XOD biosensor was constructed by electrochemical oxidation of pyrrole in the solution containing xanthine oxidase and pyrrole in this paper. Colloidal Au was then immobilized on the biosensor. On the other hand, electron mediator, Prussian Blue (PB), was deposited on the electrode before the immobilization of PPY/XOD to enhance electron‐transfer rate and current response. The results showed that PPY/XOD, PPY/XOD/Au‐colloid, PB/PPY/XOD and PB/PPY/XOD/Au‐colloid biosensors exhibit good response to xanthine in 1×10?6 M and 2×10?5 M and Michaelis‐Menten constants (Km) of these biosensors were 242.2, 113.4, 144.5, 43.2 μmol?L?1, respectively. The dependence of current responses with applied voltages was discussed, and different mechanisms of these biosensors were discussed. It has been found that colloidal Au can enhance the current response at the same concentration of xanthine solution and decrease the energy‐barrier of electron‐transfer reaction on the electrode.  相似文献   

18.
Direct electron transfer of immobilized copper, zinc‐superoxide dismutase (SOD) onto electrodeposited nickel‐oxide (NiOx) nanoparticle modified glassy carbon (GC) electrode displays a well defined redox process with formal potential of ?0.03 V in pH 7.4. Cyclic voltammetry was used for deposition of (NiOx) nanoparticles and immobilization of SOD onto GC electrode. The surface coverage (Γ) and heterogeneous electron transfer rate constant (ks) of immobilized SOD are 1.75×10?11 mol cm?2 and 7.5±0.5 s?1, respectively. The biosensor shows a fast amperometric response (3 s) toward superoxide at a wide concentration range from 10 µM to 0.25 mM with sensitivity of 13.40 nA µM?1 cm?2 and 12.40 nA µM?1 cm?2, detection limit of 2.66 and 3.1 µM based on anodically and cathodically detection. This biosensor exhibits excellent stability, reproducibility and long life time.  相似文献   

19.
A novel voltammetric method using the Ppyox/NFR/Au (poly pyrrole – nuclear fast red – gold) modified electrode was developed for simultaneous measurement of various combinations of ascorbic acid (AA) and methyldopa (MDA). Polypyrrole film was prepared by incorporation of nuclear fast red (NFR) as doping anion, during the electropolymerization of pyrrole onto a gold (Au) electrode in aqueous solution using cyclic voltammetric (CV) method, and then it was overoxidized at constant potential. Differential pulse voltammetry was utilized for the measurement of both analytes using modified electrode. Well‐separated voltammetric peaks were observed for ascorbic acid (AA) and methyldopa at the Ppyox/NFR/Au modified electrodes with peak separation of 0.210 V. It has been found that under optimum condition (pH 3.0), the oxidation of AA and MDA at the surface of the electrode occurs at a potential about 260 and 50 mV less positive than unmodified Au electrode respectively. The current catalytic oxidation peaks showed a linear dependent on the concentration of AA and MDA in the range of 9.0×10?6 to 1.0×10?3 and 1.0×10?7 to 2.0×10?5 mol L?1 respectively. The detection limit of 5.8×10?6 and 5.0×10?8 mol L?1 (S/N=3) were obtained for AA and MDA respectively. The modified electrode was used for determination of AA and MDA in some real samples such as human serum and tablet.  相似文献   

20.
《Analytical letters》2012,45(5):875-886
Abstract

Platinum nanowires (PtNW) were prepared by an electrodeposition strategy using nanopore alumina template. The nanowires prepared were dispersed in chitosan (CHIT) solution and stably immobilized onto the surface of glassy carbon electrode (GCE). The electrochemical behavior of PtNW‐modified electrode and its application to the electrocatalytic reduction of hydrogen peroxide (H2O2) are investigated. The modified electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As an application example, the glucose oxidase was immobilized onto the surface of PtNW‐modified electrode through cross‐linking by glutaric dialdehyde. The detection of glucose was performed in phosphate buffer at –0.2 V. The resulting glucose biosensor exhibited a short response time (<8 s), with a linear range of 10?5?10?2 M and detection limit of 5×10?6 M.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号