首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
This paper presents several methods for analysis of data from reflectometric interference spectroscopic measurements (RIfS) of water samples. The set-up consists of three sensors with different polymer layers. Mixtures of butanol and ethanol in water were measured from 0 to 12,000 ppm each. The data space was characterized by principal component analysis (PCA). Calibration and prediction were achieved by multivariate methods, e.g. multiple linear regression (MLR), partial least squares (PLS) with additional predictors, and quadratic partial least squares (Q-PLS), and by use of artificial neural networks. Artificial neural networks gave the best results of all the calibration methods used. Calibration and prediction of the concentration of the two analytes by artificial neural nets were robust and the set-up could be reduced to only two sensors without deterioration of the prediction. Received: 29 September 2000 / Revised: 30 April 2001 / Accepted: 3 May 2001  相似文献   

2.
武晓莉  李艳君  吴铁军 《分析化学》2006,34(8):1091-1095
为提高水质参数总有机碳(TOC)的紫外吸收光谱分析的预测精度,提出一种基于Boosting理论的迭代式回归建模算法,并根据统计学习理论提出一种新的迭代停止判据,可有效防止过拟合,显著提高模型预测精度。为评估所提算法的性能,分别采用本算法和3种常用的光谱分析方法,即偏最小二乘、主成分回归和人工神经网络,对自行研制的紫外光谱水质分析仪实测的一组数据进行了建模和预测。计算结果表明:相对于其他3种方法,本算法具有生成的模型预测精度高的显著优势。  相似文献   

3.
In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high‐performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back‐propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high‐performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back‐propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7‐O‐rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint.  相似文献   

4.
A fast, simple and costless methodology without sample pre-treatment is proposed for the discrimination of beers. It is based on cyclic voltammetry (CV) using commercial carbon screen-printed electrodes (SPCE) and includes a correction of the signals measured with different SPCE units. Data are submitted to partial least squares discriminant analysis (PLS−DA) and support vector machine discriminant analysis (SVM−DA), which allow a reasonable classification of the beers. Also, CV data from beers can be used to predict their alcoholic degree by partial least squares (PLS) and artificial neural networks (ANN). In general, non-linear methods provide better results than linear ones.  相似文献   

5.
将滴定体系调节至pH 2.0,用碱标准溶液滴定至特定pH所消耗滴定荆为测量指标,构建了多组分有机酸滴定数据阵,分别以主成分回归法、偏最小二乘法以及人工神经元网络法进行多组分拟合.结果表明,偏最小二乘法的拟合结果最佳,对混合体系中乙酸、乳酸、草酸、琥珀酸、柠檬酸和乌头酸总量的相对预测均方根误差分别为5.80%、8.88%...  相似文献   

6.
A potentiometric sensor array of four nonspecific electrodes with solid‐state membranes is developed and tested for simultaneous analysis of copper(II), mercury(II), and silver(I) ions. The cross‐sensitivity responses of the sensors for these ions are evaluated. The array potentiometric signals are processed by partial least‐squares regression (PLS) and back propagation artificial neural networks (ANN) to determinate analyte concentrations. The ANN configuration is optimized and two different training algorithms of the ANN are also evaluated. Best results are obtained when the potentiometric sensors are activated and the data are processed using ANN and the gradient descent adaptive algorithm. The system is used to quantify these heavy metals in synthetic samples and in dental amalgams with successful results.  相似文献   

7.
Metal ions such as Co(II), Ni(II), Cu(II), Fe(III) and Cr(III), which are commonly present in electroplating baths at high concentrations, were analysed simultaneously by a spectrophotometric method modified by the inclusion of the ethylenediaminetetraacetate (EDTA) solution as a chromogenic reagent. The prediction of the metal ion concentrations was facilitated by the use of an orthogonal array design to build a calibration data set consisting of absorption spectra collected in the 370-760 nm range from solution mixtures containing the five metal ions earlier. With the aid of this data set, calibration models were built based on 10 different chemometrics methods such as classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), artificial neural networks (ANN) and others. These were tested with the use of a validation data set constructed from synthetic solutions of the five metal ions. The analytical performance of these chemometrics methods were characterized by relative prediction errors and recoveries (%). On the basis of these results, the computational methods were ranked according to their performances using the multi-criteria decision making procedures preference ranking organization method for enrichment evaluation (PROMETHEE) and geometrical analysis for interactive aid (GAIA). PLS and PCR models applied to the spectral data matrix that used the first derivative pre-treatment were the preferred methods. They together with ANN-radial basis function (RBF) and PLS were applied for analysis of results from some typical industrial samples analysed by the EDTA-spectrophotometric method described. DPLS, DPCR and the ANN-RBF chemometrics methods performed particularly well especially when compared with some target values provided by industry.  相似文献   

8.
邢婉丽  何锡文  方艳红  卫红梅 《化学学报》1997,55(11):1130-1137
本文应用9个压电晶体组成传感器阵列, 每片晶体上分别涂有不同种类的冠醚衍生物, 用它来定量检测二元及三元有机蒸汽混合物, 在数据处理中比较了两种模式识别方法---偏最小二乘法(PLS)和人工神经网络法(ANN), 实验证明, ANN法在预测准确度上明显优于PLS法, 本文还讨论了解决神经网络训练过拟合现象的方法。  相似文献   

9.
Models such as ordinary least squares, independent component analysis, principle component analysis, partial least squares, and artificial neural networks can be found in the calibration literature. Linear or nonlinear methods can be used to explain the structure of the same phenomenon. Each type of model has its own advantages with respect to the other. These methods are usually grouped taxonomically, but different models can sometimes be applied to the same data set. Taxonomically, ordinary least square and artificial neural network use completely different analytical procedures but are occasionally applied to the same data set. The aim of the study of methodological superiority is to compare the residuals of models because the model with the minimum error is preferred in real analyses. Calibration models, in general, are based on deterministic and stochastic parts; in other words, the data are equal to the model + the error. Explaining a model solely using statistics such as the coefficient of determination or its related significance values is sometimes inadequate. The errors of a model, also called its residuals, must have minimum variance compared to its alternatives. Additionally, the residuals must be unpredictable, uncorrelated, and symmetric. Under these conditions, the model can be considered adequate. In this study, calibration methods were applied to the raw materials, hydrochlorothiazide and amiloride hydrochloride, of a drug, as well as a sample of the drug tablet. The applied chemical procedure was fast, simple, and reproducible. The various linear and nonlinear calibration methods mentioned above were applied, and the adequacy of the calibration methods was compared according to their residuals.  相似文献   

10.
A new chemometric method, which uses artificial neural networks (ANN), is presented for determination of the composition of urinary calculi. The selected constituents were whewellite, weddellite, and uric acid from which approximately 40% of the urinary calculi obtained from Macedonia patients are composed. The results for the synthetic mixtures were better then those obtained by partial least squares (PLS) regression or by the principal component regression (PCR), because neural networks have better prediction capacity. The generalization abilities of the optimized neural networks were checked using the standard addition method on carefully selected real natural samples.  相似文献   

11.
Hasani M  Emami F 《Talanta》2008,75(1):116-126
Mixtures of 2-, 3-, and 4-nitoroanilines, are simultaneously analyzed with spectrophotometry, based on their different kinetic properties. These nitroanilines react differentially with 1,2-naphtoquinone-4-sulphonate (NQS) at pH 7 in micellar medium to produce colored product. The differential kinetic spectra were monitored and recorded at 500 nm, and the data obtained from the experiments were processed by chemometric approaches, such as back-propagation neural networks (BPNNs), radial basis function neural networks (RBFNNs), and partial least squares (PLS). Experimental conditions were optimized and training the network was performed using principal components (PCs) of the original data. A set of synthetic mixtures of nitroanilines was evaluated and the results obtained by the application of these chemometric approaches were discussed and compared. The analytical performance of the models was characterized by relative standard errors. It was found that the artificial neural networks model affords relatively better results than PLS. The proposed method was applied to the determination of considered nitroanilines in water samples.  相似文献   

12.
Differential Pulse Voltammetry has been used for the simultaneous determination of cysteine, tyrosine and trptophan on the unmodified glassy carbon electrode. In the analysis of these analytes in the same samples, the main difficulty is the high degree of overlapping of voltammograms. The relationships between the currents and the concentrations are complex and highly nonlinear. The predictive ability of principal component regression (PCR), partial least squares regression (PLS), genetic algorithm‐partial least squares regression (GA‐PLS) and principal component‐artificial neural networks (PC‐ANNs) were examined for simultaneous determination of three amino acids. For a regression model, everything that could not help in constructing the model may be considered as noise without further specification. PC‐ANN and GA‐PLS use significant data and show superiority over other applied multivariate methods. The proposed method was also applied satisfactorily to determination of analytes in some synthetic samples.  相似文献   

13.
14.
<正>High performance liquid chromatographic(HPLC) fingerprints of Cassia seed,a traditional Chinese medicine(TCM),were developed by means of the chromatograms at two wavelengths of 238 and 282 nm.Then,the two data sets were combined into one matrix.The application of principal component analysis(PCA) for this data matrix showed that the samples were clustered into four groups in accordance with the plant sources and preparation procedures.Furthermore,partial least squares(PLS),back propagation artificial neural network(BP-ANN),and radial basis function artificial neural network(RBF-ANN) were effectively applied to predict the category of the four different samples in the test set.  相似文献   

15.
A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526nm, and the accompanying increase of the product, potassium manganate, at 608nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5mgL(-1) at 526 and 608nm for pefloxacin, and 0.15-1.8mgL(-1) at 526 and 608nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526nm, were the preferred methods-%RPE(T) approximately 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06mgL(-1), respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.  相似文献   

16.
吉海彦  严衍禄 《分析化学》1993,21(8):869-872
本文研究了用逐步回归分析法、主成分回归法、偏最小二乘法与人工神经网络法测定活体叶片中叶绿素a、b的含量。活体叶片的光谱由PC微机采集,测定叶绿素a与b的相关系数分别达到0.927~0.958与0.873~0.908;相对标准偏差约5%~9%(叶绿素a 9.4μg/2ml,n=20)。本方法可用于农业研究。  相似文献   

17.
This paper reports the development of calibration models for quality control in the production of ethylene/propylene/1-butene terpolymers by the use of multivariate tools and FT-IR spectroscopy.1-Butene concentration prediction is achieved in terpolymers by coupling FT-IR spectroscopy to multivariate regression tools. A dataset of 26 terpolymers (14 coming from a constrained experimental design for mixtures, plus 12 terpolymers used for external validation) was analysed by FT-IR spectroscopy. An internal method of “Polimeri Europa” plant, based on 13C NMR spectroscopy is used to determine the percentage of 1-butene in the samples. Then, different multivariate tools are used for 1-butene concentration prediction based on the FT-IR spectra recorded. Different multivariate calibration methods were explored: principal component regression (PCR), partial least squares (PLS), stepwise OLS regression (SWR) and artificial neural networks (ANNs). The model obtained by back-propagation neural networks turned out to be the best one. The performances of the BP-ANN model were further improved by variable selection procedures based on the calculation of the first derivative of the network.The proposed approach allows the monitoring in real time of the polymer synthesis and the estimation of the characteristics of the product attainable from the concentration of 1-butene.  相似文献   

18.

In this paper, the authors tested methodology that overcame the most common limitation of quantitative structure-retention relationship (QSRR) models: their limited applicability at the specific conditions for which models were developed. The modeling was performed on ion chromatographic analysis of “wood sugars”. Adaptive neuro-fuzzy interference system, an advanced artificial intelligence regression tool, was applied in combination with genetic algorithm scanning to obtain good and reliable QSRR models. The obtained QSRR models were applied for predicting data that were required for further development of general isocratic and gradient retention models. All three developed models (QSRR, isocratic, and gradient) indicated good prediction ability with root mean square error of prediction ≤0.1557. The performances of the methodology were compared with those presented in previous research—namely genetic algorithm in combinations with—stepwise multiple linear regression, partial least squares, uninformative variable elimination–partial least squares, and artificial neural network regression.

  相似文献   

19.
An electronic tongue (ET) based on pulse voltammetry has been used to predict the presence of nerve agent mimics in aqueous environments. The electronic tongue array consists of eight working electrodes (Au, Pt, Ir, Rh, Cu, Co, Ni and Ag) encapsulated on a stainless steel cylinder. Studies including principal component analysis (PCA), artificial neural networks (fuzzy ARTMAP) and partial least square techniques (PLS) have been applied for data management and prediction models. For instance the electronic tongue is able to discriminate the presence of the nerve agent simulants diethyl chlorophosphate (DCP) and diethyl cyanophosphate (DCNP) from the presence of other organophosphorous derivatives in water. Finally, PLS data analysis using a system of 3 compounds and 3 concentration levels shows a good accuracy in concentration prediction for DCP and DCNP in aqueous environments.  相似文献   

20.
A method intended to serve as a multivariate quality control tool in the production of pharmaceutical proteins is presented. The method is based on multivariate analysis of peptide maps generated with liquid chromatography-mass spectrometry (LC-MS). Lactate dehydrogenase (LDH) from different species and tissues were used as model compounds in the study. The proteins were digested with Endoproteinase Lys-C before the LC-MS analysis. After data pretreatment of the peptide maps, successful classification of the LDHs were obtained by discriminant analysis with partial least squares regression and artificial neural networks. Further, principal component analysis was applied to visualize the relationships between the samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号