首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 732 毫秒
1.
A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 °C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g−1 for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g−1 level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.   相似文献   

2.
A new method has been developed for the multi-residue measurement of the main brominated flame retardants (alpha- and gamma-hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBP-A) and polybrominated diphenyl ethers including decabromodiphenyl ether) in human biological matrices (serum, adipose tissue and breast milk). The proposed sample preparation procedure focused on reduced solvent and consumable consumption and associated procedural contamination, as well as reduced sample size. This protocol was fully validated and was proved to be suitable for identification of brominated flame retardant residues at ultra-trace level, as attested by preliminary results on real samples.  相似文献   

3.
Summary Several plastics (polyester and hardened epoxideresins) with flame retardants as additives were tested for the formation of brominated dibenzofurans and dibenzodioxins under temperatures from 400 °C to 800 °C under aerobic conditions. 2,3,7,8-Tetrabromodibenzodioxin was not formed at a detection limit of 10 ppm (g·g–1). At 400 °C, polymers containing decabromodiphenylether and antimony trioxide as flame retardant yield up to 4,000 ppm tetrabromodibenzofurans (TBrDF), besides other brominated dibenzofurans.In contrast, formation of polybrominated dibenzofurans does not occur with polymers containing decabromodiphenylether without antimony trioxide. 2,3,7,8-Tetrabromodibenzufuran could not be found at a detection limit of 20 ppm. Under the given thermolytical conditions, polymers with brominated flame retardants such as tetrabromobisphenol-A, polytribromostyrene, hydroxyethylated tetrabromobenzimidazolone, poly(pentabromobenzyl)acrylate or N,N-ethylene-bis-tetrabromophthalimide snowed no tendency to form polybrominated dibenzodioxins or dibenzofurans, even in the presence of antimony trioxide.  相似文献   

4.
Brominated flame retardants in laboratory air   总被引:1,自引:0,他引:1  
During the development of a method for determination of brominated flame retardants in human plasma and serum using solid-phase extraction, several brominated flame retardants were found in the procedural blanks. The contaminants originated most probably from the laboratory air. The brominated flame retardants were found to be adsorbed on glass surfaces and to be acquired using solid-phase sampling. 2,4,6-Tribromophenol, 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) and 2,2',4,4',5-pentabromodiphenyl ether (BDE-99) were the most abundant brominated flame retardants in our laboratory air, however, large differences in contamination with respect to sampling time and place were observed.  相似文献   

5.
Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GCxGC-muECD) was evaluated for the separation of 125 polybrominated diphenyl ethers (PBDEs). From among the six column combinations that were evaluated, DB-1x007-65HT was found to be the most suitable because of: (i) the highest number of BDE congeners separated; (ii) the least decomposition of higher brominated congeners; and (iii) the most suitable maximum operating temperature. The separation of the 125 BDE congeners from five hydroxy- and two methoxy-BDEs and nine other brominated flame retardants (polybrominated biphenyls, tetrabromobisphenol-A, methyl-tetrabromobisphenol-A and hexabromocyclododecane) was also studied. Fluorinated BDEs were found to be valuable internal standards for the determination of BDEs because of their very similar physico-chemical properties and excellent separation from the parent BDEs, mainly in the second dimension. GCxGC-time-of-flight MS and GCxGC-muECD were shown to be useful tools to identify decomposition products of nona- and deca-substituted BDEs, which are formed during the GC run. Three nona-BDEs were shown to be the major decomposition products of BDE 209.  相似文献   

6.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

7.
The article describes the analysis of brominated flame retardants, namely polybrominated diphenyl ethers in wastewater by gas chromatography/time-of-flight mass spectrometry. As a sample preparation method microextraction in packed syringe was used. The possibilities of this method for rapid analysis of water were investigated. It was shown, that this approach minimizes sample handling and reduces time/cost of measurement.  相似文献   

8.
Polybrominated organic compounds are ubiquitous throughout the environment. This generic term comprises several classes of brominated flame retardants (e.g., polybrominated diphenyl ethers, polybrominated biphenyls, hexabromocyclododecane, dibromopropyltribromophenyl ether, 1,2-bis(2,4,6-tribromophenoxy)ethane) as well as a range of marine halogenated natural products (HNPs). Here we present gas chromatography retention times and elution orders (on DB-5) of 122 polybrominated compounds that may be found in food and environmental samples. Organobromine compounds in fish samples determined with gas chromatography interfaced to electron-capture negative ion mass spectrometry (GC/ECNI-MS) are discussed. The environmental relevance and important mass spectrometric features of the compounds are described as well. Our database aims to support the closer inspection and identification of peaks in gas chromatograms and to initiate dedicated screening for less frequently studied organobromines in samples.  相似文献   

9.
The preparation, properties and application of carbon fibers for SPME   总被引:1,自引:0,他引:1  
Gierak A  Seredych M  Bartnicki A 《Talanta》2006,69(5):1079-1087
The conditions of preparation of new types of carbon fibers for solid phase micro extraction (SPME) prepared by methylene chloride pyrolysis (at 600 °C) on the quartz fiber (100 μm) as well as by supporting synthetic active carbon (prepared especially for this purposes) supported in a special epoxide-acrylic polymer is described. The properties of such carbon fibers for SPME were defined by determination of the partition coefficient of the tested substances (i.e., benzene, toluene, xylenes, trichloromethane and tetrachloromethane) and by the microscopic investigations with the application of the optical and scanning electron microscope.

The obtained carbon SPME fibers were applied to the analysis of some volatile organic compounds from its aqueous matrix. During chromatographic GC test, at the investigated SPME carbon fibers, we obtained different but mostly high partition coefficients for the determined compounds (Kfs from 120 for trichloromethane up to 11,500 for tetrachloromethane).

Owing to the high partition coefficients of the studied substances obtained on carbon fibers, it was possible to do the analysis of organic substances occurring in trace amounts in different matrices. In this paper, we present the analysis of BTX contents in the petrol analyzed with the application carbonized with CH2Cl2 SPME fiber (C1NM) and a headspace over the petrol sample (concentration of each BTX g/dm3).  相似文献   


10.
This review provides a summary of various analytical methodologies applied to the determination of “novel” brominated flame retardants (NBFRs) in various environmental compartments, as reported in peer reviewed literature, either in print or online, until the end of 2010. NBFRs are defined here as those brominated flame retardants (BFRs) which are either new to the market or newly/recently observed in the environment. The preparation and extraction of sediment, water, sewage sludge, soil, air and marine biota samples, the extract clean-up/fractionation and subsequent instrumental analysis of NBFRs are described and critically examined. Generally, while the instrumental analysis step mainly relies on mass-spectrometric detection specifically developed for NBFRs, and hyphenated to liquid or gas chromatography, preceding steps tend to replicate methodologies applied to the determination of traditional BFRs such as polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). Shortcomings and gaps are discussed and recommendations for future development are given.  相似文献   

11.
Octanol-water partition coefficients (Kow) for 57 terpenoids were measured using a RP-HPLC method. Sample detection was achieved with standard UV and refractive index detectors and required no special column treatment. Measured log Kow values for the terpenoids ranged from 1.81 to 4.48 with a standard error of between 0.03 and 0.08 over the entire range. Partition coefficients determined by the RP-HPLC method were compared against shake flask, atom/fragment contribution, fragment and atomistic methods. The HPLC values were found to give the best correlation with shake flask results. Log Kow values calculated by the atom/fragment contribution method gave the best correlation with the HPLC values when compared to fragment and atomistic methods.  相似文献   

12.
王翊如  王小如  FrankSCLee 《色谱》1999,17(5):424-426
采用固相微萃取 气相色谱/质谱联用技术分析了水中11种多环芳烃,并获得其平衡时的分配系数。当固相微萃取纤维上涂渍的固定液被视为一种有机溶剂时,根据萃取系统间线性的自由能关系,建立了聚二甲基硅氧烷 水分配系数(Ksw)与正辛醇 水分配系数(Kow)间的关系式,并将其应用于估算其它多环芳烃的未知的醇 水分配系数。所建立的方法简单、快速,与Leo碎片法相比,可以更精确地估算取代基位置不同的同分异构体的Kow。  相似文献   

13.
As an inexpensive, simple, and low-solvent consuming extraction technique, the suitability of solid-phase microextraction (SPME) with polydimethylsiloxane (PDMS) sorbent was investigated as a quantitative method for sampling gaseous organophosphate triesters in air. These compounds have become ubiquitous in indoor air, because of their widespread use as additive flame retardants/plasticizers in various indoor materials. Results obtained by sampling these compounds at controlled air concentrations using SPME and active sampling on glass fibre filters were compared to evaluate the method. A constant linear airflow of 10 cm s–1 over the fibres was applied to increase the extraction rate. For extraction of triethyl phosphate with a 100-m PDMS fibre, equilibrium was achieved after 8 h. The limit of detection was determined to be less than 10 pg m–3. The PDMS–air partition coefficients, Kfs, for the individual organophosphate triesters were determined to be in the range 5–60×106 at room temperature (22–23°C). Air measurements were performed utilising the determined coefficients for quantification. In samples taken from a lecture room four different airborne organophosphate esters were identified, the most abundant of which was tris(chloropropyl) phosphate, at the comparatively high level of 1.1 g m–3. The results from SPME and active sampling had comparable repeatability (RSD less than 17%), and the determined concentrations were also similar. The results suggest that the investigated compounds were almost entirely associated with the gaseous phase at the time and place sampled.  相似文献   

14.
Applications of solid-phase microextraction (SPME) in the measurement of very hydrophobic organic compounds (VHOCs) are limited, partly due to the difficulty of calibrating SPME fibers for VHOCs. This study used a static SPME strategy with a large sample volume (1.6 L) and a five-point calibration procedure to determine the distribution coefficients for a large suite of polychlorinated biphenyls (PCBs) and chlorinated pesticides between a polydimethylsiloxane (PDMS) phase (100 microm thickness) coated on a glass fiber and seawater. An extraction time of 12 days was deemed adequate for equilibrium calibration from kinetic experiments. Two groups of randomly selected fibers divided into three batches (up to nine fibers in each batch) were processed separately with two gas chromatography-mass spectrometry (GC-MS) systems. Matrix effects arising from losses of the analytes to glass container walls and stirring bars were corrected. Relative standard deviations within the same batch were generally smaller than those for the entire group. Furthermore, KfVf (Kf and Vf are the distribution coefficient of an analyte between the polymer-coated fiber and aqueous phase and the fiber volume, respectively) values determined with two GC-MS systems were statistically different. These results indicate the calibrated KfVf values were less affected by the random selection of SPME fibers than by other experimental conditions, and therefore average KfVf values may be used for the same type of commercially available SPME fibers. The relative accuracy of our calibration method was similar to that of a previous study [P. Mayer. W.H.J. Vaes, J.L.M. Hermens, Anal. Chem. 72 (2000) 459] employing different coating thickness and calibration procedure. The present study also obtained a bell-shaped relationship between log Kf and log Kow (octanol-water partition coefficient) for PCB congeners with the maximum log Kf corresponding to log Kow approximately 6.5. This bell-shaped relationship was attributed mainly to steric effects arising from the interplay between the PDMS thickness and molecular sizes of the target analytes.  相似文献   

15.
An HPLC-UV/MS method has been developed to identify and quantify flame retardants in post-consumer plastics from waste of electric and electronic equipment (WEEE). Atmospheric pressure chemical ionisation spectra of 15 brominated and phosphate-based flame retardants were recorded and interpreted. The method was applied to detect flame retardant additives in polymer extracts obtained from pressurised liquid extraction of solid polymers. In addition, a screening method was developed for soluble styrene polymers to isolate a flame retardant fraction through the application of gel permeation chromatography (GPC). This fraction was transferred to an online-coupled HPLC column and detected by UV spectroscopy, which allowed a reliable qualitative and quantitative analysis of brominated flame retardants in the polymer solutions.  相似文献   

16.
This article reviews recent literature on the analysis of brominated flame retardants (BFRs) and brominated natural compounds (BNCs). The main literature sources are reviews from the last five years and research articles reporting new analytical developments published between 2003 and 2006. Sample pretreatment, extraction, clean-up and fractionation, injection techniques, chromatographic separation, detection methods, quality control and method validation are discussed. Only few new techniques, such as solid-phase microextraction (SPME) or pressurized liquid extraction (PLE), have been investigated for their ability of combining the extraction and clean-up steps. With respect to the separation of BFRs, the most important developments were the use of comprehensive two-dimensional gas chromatography for polybrominated diphenyl ethers (PBDEs) and the growing tendency for liquid-chromatographic techniques for hexabromocyclododecane (HBCD) stereoisomers and of tetrabromobisphenol-A (TBBP-A). At the detection stage, mass spectrometry (MS) has been developed as well-established and reliable technology in the identification and quantification of BFRs. A growing attention has been paid to quality assurance. Interlaboratory exercises directed towards BFRs have grown in popularity and have enabled laboratories to validate analytical methods and to guarantee the quality of their results. The analytical procedures used for the identification and characterization of several classes of BNCs, such as methoxylated polybrominated diphenyl ethers (MeO-PBDEs) (also metabolites of PBDEs), halogenated methyl or dimethyl bipyrroles (DBPs), are reviewed here for the first time. These compounds were generally identified during the routine analysis of BFRs and have received little attention until recently. For each topic, an overview is presented of its current status.  相似文献   

17.
The feasibility of solid-phase microextraction (SPME) for the determination of several organophosphorus flame retardants and plastizicers in water samples by gas chromatography-nitrogen phosphorous detection (GC-NPD) is evaluated. These compounds have a wide range of polarities and volatilities and require a thorough optimisation of the different SPME parameters. Considering also possible contamination and carryover sources, the best compromise microextraction conditions were found to be direct extraction of 22 ml samples, containing 300 mg/ml of NaCl, with a PDMS-DVB coated fibre at room temperature. Although equilibrium was not achieved, an extraction time of 40 min allowed obtaining a good sensitivity (quantification limits between 0.010 and 0.025 ng/ml), comparable to that achieved by solid-phase extraction (SPE) of 1l samples, producing both similar values of precision and accuracy. Furthermore, the SPME method has shown to be free of matrix effects, avoiding the need of employing the standard addition procedure for quantification, and was suitable for the determination of eight of the nine considered compounds. Only tris-(2-ethylhexyl)-phosphate was neither determinable by SPME nor by SPE. Finally, the application of the developed methodology to the analysis of wastewater samples, showed that important concentrations of these compounds (up to 10 ng/ml) have been detected in treated sewage water, being discharged into the aquatic environment.  相似文献   

18.
报道了氯代苯、醇、酯类化合物气相色谱保留指数与其正辛醇-水分配系数的相关性,研究了固定相极性对相关性影响,得出弱极性柱上测得的化合物保留指数能更准确地预测其分配系数,从而为极性化合物氯代苯、醇、酯分配系数的测定和预测提供了一种简便易行的新方法。  相似文献   

19.
Pressurised hot water extraction (PHWE) was coupled on-line with liquid chromatography-gas chromatography (LC-GC) to determine brominated flame retardants in sediment samples. After extraction with pressurised hot water the analytes were adsorbed in a solid-phase trap. The trap was dried with nitrogen and the analytes were eluted to the LC column, where the extract was cleaned, concentrated and fractionated before transfer to the GC system. The fraction containing the brominated flame retardants was transferred to the GC system via an on-column interface. The PHWE-LC-GC method was linear from 0.0125 to 2.5 microg with limits of detection in the range 0.70-1.41 ng/g and limits of quantification 6.16-12.33 ng/g.  相似文献   

20.
Gas chromatography in combination with electron capture negative ion mass spectrometry (GC/ECNI‐MS) is a sensitive method for the determination of polybrominated compounds in environmental and food samples via detection of the bromide ion isotopes m/z 79 and 81. The standard reagent gas for inducing chemical ionization in GC/ECNI‐MS is methane. However, the use of methane has some drawbacks as it promotes carbonization of the filament and ion source. In this study, we explored the suitability of nitrogen as reagent gas for the determination of brominated flame retardants (polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls (PBBs), allyl‐2,4,6‐tribromophenyl ether (ATE) and 2,3‐dibromopropyl‐2,4,6‐tribromophenyl ether (DPTE)) and halogenated natural products (for instance, methoxylated tetrabrominated diphenylethers and polybrominated hexahydroxanthene derivatives). An ion source temperature of 250°C and a nitrogen pressure of 7 Torr in the ion source gave the highest response for m/z 79 and 81 of virtually all investigated polybrominated compounds. Using these conditions, nitrogen‐mediated GC/ECNI‐MS usually gave higher sensitivity than the method with methane previously used in our lab. In addition, the ion source was not contaminated to the same degree and the lifetime of the filament was significantly increased. Moreover, the response factors of the different polybrominated compounds with the exception of 2,4,6‐tribromophenol were more uniform than with methane. Nitrogen is available at very high purity at relatively low price. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号