首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new rapid, convenient and sensitive electrochemical method based on a gold nanoparticles modified ITO (Au/ITO) electrode is described for the detection of dopamine and serotonin in the presence of a high concentration of ascorbic acid. The electrocatalytic response was evaluated by differential pulse voltammetry (DPV) and the modified electrode exhibited good electrocatalytic properties towards dopamine and serotonin oxidation with a peak potential of 70 mV and 240 mV lower than that at the bare ITO electrode, respectively. The selective sensing of dopamine is further improved by applying square wave voltammetry (SWV) which leads to the lowering of its detection limit. A similar effect on the detection limit of serotonin was observed on using SWV. Linear calibration curves are obtained in the range 1.0 × 10−9-5.0 × 10−4 M and 1.0 × 10−8-2.5 × 10−4 M with a detection limit of 0.5 nM and 3.0 nM for dopamine and serotonin, respectively. The Au/ITO electrode efficiently determines both the biomolecules simultaneously, even in the presence of a large excess of ascorbic acid. The adequacy of the developed method was evaluated by applying it to the determination of the content of dopamine in dopamine hydrochloride injections. The proposed procedure was also successfully applied to simultaneously detect dopamine and serotonin in human serum and urine.  相似文献   

2.
A sensitive, rapid and reliable electrochemical method based on voltammetry at single wall carbon nanotube (SWNT) modified edge plane pyrolytic graphite electrode (EPPGE) is proposed for the simultaneous determination of prednisolone and prednisone in human body fluids and pharmaceutical preparations. The electrochemical response of both the drugs was evaluated by osteryoung square wave voltammetry (OSWV) in phosphate buffer medium of pH 7.2. The modified electrode exhibited good electrocatalytic properties towards prednisone and prednisolone reduction with a peak potential of ∼−1230 and ∼−1332 mV respectively. The concentration versus peak current plots were linear for both the analytes in the range 0.01-100 μM and the detection limit (3σ/slope) observed for prednisone and prednisolone were 0.45 × 10−8, 0.90 × 10−8 M, respectively. The results of the quantitative estimation of prednisone and prednisolone in biological fluids were also compared with HPLC and the results were in good agreement.  相似文献   

3.
Goyal RN  Bishnoi S  Chasta H  Aziz MA  Oyama M 《Talanta》2011,85(5):2626-2631
The effect of surface modification of indium tin oxide (ITO) by multi wall carbon nanotube (MWNT) and gold nanoparticles attached multi wall carbon nanotube (AuNP-MWNT) has been studied to determine tryptophan, an important and essential amino acid for humans and herbivores. A detailed comparison has been made among the voltammetric response of bare ITO, MWNT/ITO and AuNP-MWNT/ITO in respects of several essential analytical parameters viz. sensitivity, detection limit, peak current and peak potential of tryptophan. The AuNP-MWNT/ITO exhibited a well defined anodic peak at pH 7.2 at a potential of ∼669 mV for the oxidation of tryptophan as compared to 760 mV at MWNT/ITO electrode. Under optimum conditions linear calibration curve was obtained over tryptophan concentration range 0.5-90.0 μM in phosphate buffer solution of pH 7.2 with detection limit and sensitivity of 0.025 μM and 0.12 μA μM−1, respectively. The oxidation of tryptophan occurred in a pH dependent, 2e and 2H+ process and the electrode reaction followed adsorption controlled pathway. The method has been found selective and successfully implemented for the determination of tryptophan in human urine and plasma samples using standard addition method. The electrode exhibited an efficient catalytic response with good reproducibility and stability.  相似文献   

4.
Goyal RN  Bishnoi S 《Talanta》2011,84(1):78-83
The simultaneous determination of catecholamines - epinephrine and norepinephrine by square wave voltammetry (SWV) at physiological pH 7.2 is reported using multi-walled carbon nanotubes modified edge plane pyrolytic graphite electrode (MWNT/EPPGE). A broad bump at ∼250 mV is appeared for the oxidation of epinephrine (EP) and norepinephrine (NE) at bare EPPGE whereas at MWNT/EPPGE two well-separated peaks at ∼150 and ∼215 mV are appeared for the oxidation of EP and NE, respectively. The oxidation peak current of both the neurotransmitters also increased significantly along with the negative shift of peak potentials using MWNT/EPPGE. The oxidation of both compounds occurred in a pH dependent, 2e and 2H+ process and the electrode reaction followed diffusion controlled pathway. Linear calibration curves were obtained for epinephrine and norepinephrine in the range 0.5-100 nM with limits of detection 0.15 × 10−9 and 0.90 × 10−10 M, respectively. The developed protocol is implemented for the simultaneous determination of epinephrine and norepinephrine in blood plasma and urine samples of smokers as well as in athletes.  相似文献   

5.
A graphene, chitosan and Fe3O4 nanoparticles (nano-Fe3O4) modified glassy carbon electrode (graphene-chitosan/nano-Fe3O4/GCE) was fabricated. The modified electrode was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The electrochemical oxidation behavior of guanosine was investigated in pH 7.0 phosphate buffer solution by cyclic voltammetry and differential pulse voltammetry. The experimental results indicated that the modified electrode exhibited an electrocatalytic and adsorptive activities towards the oxidation of guanosine. The transfer electron number (n), transfer proton number (m) and electrochemically effective surface area (A) were calculated. Under the optimized conditions, the oxidation peak current was proportional to guanosine concentration in the range of 2.0 × 10−6 to 3.5 × 10−4 mol L−1 with the correlation coefficient of 0.9939 and the detection limit of 7.5 × 10−7 mol L−1 (S/N = 3). Moreover, the modified electrode showed good ability to discriminate the electrochemical oxidation response of guanosine, guanine and adenosine. The proposed method was further applied to determine guanosine in spiked urine samples and traditional Chinese medicines with satisfactory results.  相似文献   

6.
A fullerene-C60-modified glassy carbon electrode (GCE) is used for the simultaneous determination of adenosine and guanosine by differential pulse voltammetry. Compared to a bare glassy carbon electrode, the modified electrode exhibits an apparent shift of the oxidation potentials in the cathodic direction and a marked enhancement in the voltammetric peak current response for both the biomolecules. Linear calibration curves are obtained over the concentration range 0.5 μM-1.0 mM in 0.1 M phosphate buffer solution at pH 7.2 with a detection limit of 3.02 × 10−7 M and 1.45 × 10−7 M for individual determination of adenosine and guanosine, respectively. The interference studies showed that the fullerene-C60-modified glassy carbon electrode exhibited excellent selectivity in the presence of hypoxanthine, xanthine, uric acid and ascorbic acid. The proposed procedure was successfully applied to detect adenosine and guanosine in human blood plasma and urine, without any preliminary pre-treatment.  相似文献   

7.
The electrochemical behaviors of guanosine on the ionic liquid of N-butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CPE) was studied in this paper and further used for guanosine detection. Guanosine showed an adsorption irreversible oxidation process on the carbon ionic liquid electrode (CILE) with the oxidation peak potential located at 1.12 V (vs. SCE) in a pH 4.5 Britton-Robinson (B-R) buffer solution. Compared with that on the traditional carbon paste electrode, small shift of the oxidation peak potentials appeared but with a great increment of the oxidation peak current on the CILE, which was due to the presence of ionic liquid in the modified electrode adsorbed the guanosine on the surface and promoted the electrochemical response. The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n), and the electrode reaction standard rate constant (ks) were calculated as 0.74, 1.9 and 1.26 × 10−4 s−1, respectively. Under the optimal conditions the oxidation peak current showed a good linear relationship with the guanosine concentration in the range from 1.0 × 10−6 to 1.0 × 10−4 mol/L by cyclic voltammetry with the detection limit of 2.61 × 10−7 mol/L (3σ). The common coexisting substances showed no interferences to the guanosine oxidation. The CILE showed good ability to distinguish the electrochemical response of guanosine and guanine in the mixture solution. The urine samples were further detected by the proposed method with satisfactory results.  相似文献   

8.
This paper describes the simultaneous determination of epinephrine (EP), uric acid (UA) and xanthine (XN) in the presence of ascorbic acid (AA) using electropolymerized ultrathin film of 5-amino-1,3,4-thiadiazole-2-thiol (p-ATT) modified glassy carbon (GC) electrode in 0.2 M phosphate buffer solution (pH 5). Although bare GC electrode resolves the voltammetric signals of AA and XN, it fails to resolve the voltammetric signals of EP and UA in a mixture. However, the p-ATT modified electrode not only separates the voltammetric signals of AA, EP, UA and XN with potential difference of 150, 120 and 400 mV between AA-EP, EP-UA and UA-XN, respectively but also shows higher oxidation current for these molecules. The p-ATT modified electrode exhibits excellent selectivity towards the oxidation of EP, UA and XN in the presence of 40-fold higher concentration of AA. Further, the p-ATT modified electrode was also used for the selective determination of EP in the presence of 40-fold higher concentrations of AA, UA and XN. Using amperometric method, we achieved the lowest detection of 40 nM EP and 60 nM each UA and XN. The amperometric current response was increased linearly with increasing EP concentration in the range of 4.0 × 10−8 to 4.0 × 10−5 M and the detection limit was found to be 27 × 10−11 M (S/N = 3). The practical application of the present modified electrode was demonstrated by determining the concentration of EP in epinephrine tartrate injection and XN in human urine samples.  相似文献   

9.
A novel Cu-zeolite A/graphene modified glassy carbon electrode for the simultaneous electrochemical determination of dopamine (DA) and ascorbic acid (AA) has been described. The Cu-zeolite A/graphene composites were prepared using Cu2+ functionalized zeolite A and graphene oxide as the precursor, and subsequently reduced by chemical agents. The composites were characterized by X-ray diffraction, Fourier transform infrared spectra and scanning electron microscopy. Based on the Cu-zeolite A/graphene-modified electrode, the potential difference between the oxidation peaks of DA and AA was over 200 mV, which was adequate for the simultaneous electrochemical determination of DA and AA. Also the proposed Cu-zeolite/graphene-modified electrode showed higher electrocatalytic performance than zeolite/graphene electrode or graphene-modified electrode. The electrocatalytic oxidation currents of DA and AA were linearly related to the corresponding concentration in the range of 1.0 × 10−7–1.9 × 10−5 M for DA and 2.0 × 10−5–2.0 × 10−4 M for AA. Detection limits (<!-- no-mfc -->S/N<!-- /no-mfc --> = 3) were estimated to be 4.1 × 10−8 M for DA and 1.1 × 10−5 M for AA, respectively.  相似文献   

10.
Electrochemical behavior of cerium hexacyanoferrate (CeHCF) incorporated on multi-walled carbon nanotubes (MWNTs) modified GC electrode is investigated by scanning electron microscopy (SEM) and electrochemical techniques. The CeHCF/MWNT/GC electrode showed potent electrocatalytic activity toward the electrochemical oxidation of tryptophan in phosphate buffer solution (pH 7.0) with a diminution of the overpotential of 240 mV. The anodic peak currents increased linearly with the concentration of tryptophan in the range of 2.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 2.0 × 10−8 M (at a S/N = 3). And the determination of tryptophan in pharmaceutical samples was satisfactory.  相似文献   

11.
A glassy carbon electrode (GCE) was modified with electropolymerized films of isonicotinic acid in pH 5.6 phosphate buffer solution (PBS) by cyclic voltammetry (CV). The modified electrode showed an excellent electrocatalytical effect on the oxidation of norepinephrine (NE). In PBS of pH 7.4, the oxidation current increased linearly with two concentration intervals of NE, one is 4.0×10−7 to 1.0×10−5 M, the other is 1.0×10−5 to 2.0×10−4 M. The detection limit (S/N=3) obtained by DPV was 6.0×10−9 M. Then the modified electrode was used to determine NE in an excess of ascorbic acid (AA) by difference pulse voltammetry. The peak potentials recorded in a PBS of pH 7.4 were −68 and +111 mV versus SCE for AA and NE, respectively. The high selectivity and sensitivity for NE was found to be due to the very distinct attracting interaction between NE cations and the negtively charged poly(isonicotinic acid) film in pH 7.4 PBS. The proposed method exhibited good recovery and reproducibility.  相似文献   

12.
A novel bimediator amperometric sensor is fabricated for the first time by surface modification of graphite electrode with thionine (TH) and nickel hexacyanoferrate (NiHCF). The electrochemical behavior of the TH/NiHCF bimediator modified electrode was characterized by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The TH/NiHCF bimediator modified electrode exhibited a pair of distinct redox peaks for NiHCF and TH with formal potentials of 0.33 V and −0.27 V vs. SCE at a scan rate of 50 mV s−1 in 0.1 M NaNO3 and 0.1 M NH4NO3 respectively. The electrocatalytic activity of the bimediator modified electrode towards oxidation of gallic acid with NiHCF and reduction of hydrogen peroxide with TH was evaluated and it was observed that the modified electrode showed an electrocatalytic activity towards the oxidation of gallic acid in the concentration range of 4.99 × 10−6–1.20 × 10−3 M with a detection limit of 1.66 × 10−6 M (S/N = 3) and reduction of H2O2 in the concentration range of 1.67 × 10−6–1.11 × 10−3 M with a detection limit of 5.57 × 10−7 M (S/N = 3). The bimediator modified electrode was found to exhibit good stability and reproducibility.  相似文献   

13.
A new method is developed for the catalytic oxidation of ascorbic acid at graphite zeolite-modified electrode, doped with copper(II) (Cu2+A/ZCME). Copper(II) exchanged in zeolite type A acts as catalyst to oxidize ascorbic acid. The modified electrode lowered the overpotential of the reaction by ∼400 mV. First, the electrochemical behavior of copper(II), incorporated in the zeolite type A modified electrode, was studied. The results illustrate that diffusion can control the copper(II)/copper(0) redox process at the Cu2+A/ZCME. Then, the behavior of electrocatalytic oxidation reaction for ascorbic acid was researched. The electrode was employed to study electrocatalytic oxidation of ascorbic acid, using cyclic voltammetry and chronoamperometry as diagnostic techniques. The diffusion coefficient of ascorbic acid was equal to 1.028 × 10−5 cm2 s−1. A linear calibration graph was obtained over the ascorbic acid with a concentration range of 0.003-6.00 mmol L−1. The detection limit (DL) of ascorbic acid was estimated as 2.76 × 10−7 mol L−1. The relative standard deviations of 10 replicate measurements (performed on a single electrode at several ascorbic acid concentrations between 3.0 and 200 μmol L−1) were measured between 1.0 and 2.4%.  相似文献   

14.
This paper describes a potentiometric method for determination of l-histidine (l-his) in aqueous media, using a carbon paste electrode modified with tetra-3,4-pyridinoporphirazinatocopper(II) (Cu (3,4tppa)). The electrode exhibits linear response to the logarithm of the concentration of l-histidine from 2.4 × 10−5 to 1.0 × 10−2 M, with a response slope of −49.5 ± 1 mV and response time of about 1.5 min. The detection limit according to IUPAC recommendation was 2.0 × 10−5 M. The proposed electrode shows a good selectivity for l-his over a wide variety of anions. This chemically modified carbon paste electrode was successfully used for the determination of l-his in a synthetic serum and RANDOX control serum solutions.  相似文献   

15.
This paper describes the fabrication of graphene on glassy carbon electrode (GCE) by electrochemical reduction of graphene oxide (GO) attached through 1,6-hexadiamine on GCE and the simultaneous determination of structurally similar four purine derivatives using the resultant electrochemically reduced GO (ERGO) modified electrode. The electrocatalytic activity of ERGO was investigated toward the oxidation of four important purine derivatives, uric acid (UA), xanthine (XN), hypoxanthine (HXN) and caffeine (CAF) at physiological pH. The modified electrode not only enhanced the oxidation currents of the four purine derivatives but also shifted their oxidation potentials toward less positive potentials in contrast to bare GCE. Further, it successfully separates the voltammetric signals of the four purine derivatives in a mixture and hence used for the simultaneous determination of them. Selective determination of one purine derivative in the presence of low concentrations other three purine derivatives was also realized at the present modified electrode. Using differential pulse voltammetry, detection limits of 8.8 × 10−8 M, 1.1 × 10−7 M, 3.2 × 10−7 M and 4.3 × 10−7 M were obtained for UA, XN, HXN and CAF, respectively. The practical application of the modified electrode was demonstrated by simultaneously determining the concentrations of UA, XN, HXN and CAF in human blood plasma and urine samples.  相似文献   

16.
Goyal RN  Singh SP 《Talanta》2006,69(4):932-937
C60-modified glassy carbon electrode has been found to exhibit excellent electrocatalytic activity towards atenolol oxidation for its voltammetric determination at physiological pH. Lowering of overpotential associated with atenolol oxidation indicates electrocatalytic nature of electrode. Determination of atenolol was carried out at pH 7.2 at modified electrode and a well-defined oxidation peak has been observed ∼1040 mV versus Ag/AgCl electrode for atenolol oxidation. Calibration plot having good co-linearity with a correlation coefficient 0.997 was obtained in the concentration range of 0.25-1.5 mM atenolol and the sensitivity of the method has been found to be 8.58 μA mM−1. The detection limit is found to be 0.16 mM. The method developed is applicable for atenolol determination in pharmaceutical preparations and urine samples. The modified electrode showed a good surface coverage (∼85%) with C60.  相似文献   

17.
Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode was prepared by electrochemical polymerization technique. The properties of modified electrode was studied. It was found that the electrochemical properties of modified electrode was very much dependent on the experimental conditions, such as monomer oxidation potential and pH. The modified electrode surface was characterized by scanning electron microscopy (SEM). The PEDOT-PANS film modified electrode shows electrocatalytic activity toward oxidation of dopamine (DA) in acetate buffer solution (pH 5.0) and results in a marked enhancement of the current response. The linear sweep voltammetric (LSV) peak heights are linear with DA concentration from 2 × 10−6 to 1 × 10−5 M. The detection limit is 5 × 10−7 M. More over, the interferences of ascorbic acid (AA) and uric acid (UA) were effectively diminished. This work provides a simple and easy approach for selective determination of dopamine in the presence of ascorbic acid and uric acid.  相似文献   

18.
The electrochemical behavior of nandrolone decanoate (ND) at gold nanoparticles modified indium tin oxide (ITO) electrode was investigated. Oxidation of ND has been carried out in phosphate containing supporting electrolyte in the pH range 2.1-9.2 and a well-defined oxidation peak was noticed. The peak potential (Ep) of the oxidation peak decreases linearly with increasing pH. Linear calibration curve is obtained over the nandrolone decanoate concentration range of 50 nM to 1.5 μM at pH 7.2 with a detection limit of 1.36 × 10−7 M. The proposed method is effectively applied to detect the concentration of ND in human blood serum and urine samples after 24 and 72 h of intramuscular injection. The method is rapid and does not require any pre-treatment.  相似文献   

19.
A new functionalized nanoporous silica gel with dipyridyl group (DPNSG) was synthesized. Then, the potentiometric response of the copper(II) ion was investigated at a carbon paste electrode chemically modified with this newly designed functionalized nanoporous silica gel. The electrodes with DPNSG proportions of 15.0% (w/w) demonstrated very stable potentials. Calibration plots with Nernstian slopes for Cu2+ were observed, 28.4 (±1.0) mV decade−1, over a wide linear concentration range (1.0 × 10−7 to 1.0 × 10−2 M). The electrode exhibited a detection limit of 8.0 × 10−8 M. Moreover, the selectivity coefficients measured by the match potential method in acetate buffer, pH 5.5, were investigated. The electrode presented a response time of ∼50 s, high performance, high sensitivity in a wide range of cation activities and good long-term stability (more than 9 months). The method was satisfactory and was used to determine the copper ion concentration in waste waters, contaminated by this metal.  相似文献   

20.
A chemically modified carbon paste electrode with 3,4-tetra pyridinoporphirazinatocobalt(II) (Co(3,4 tppa) was applied to the determination of free cyanide ion. The electrode has a linear range between 1.5 × 10−5 M and 1.0 × 10−2 M with a Nernstian slope of 60 ± 1.5 mV/decade and its detection limit is 9 × 10−6 M. The response time of electrode is 5 min. The proposed electrode was applied successfully for the determination of cyanide in commercially available spring water. Some anions, such as SCN, I, Cl, Br and oxalate that are usually serious interfering species for most of cyanide selective electrodes, did not have any interfering effect for this proposed electrode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号