首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 109 毫秒
1.
施超欧  姚宝龙  胡咪  陈爱连 《色谱》2016,34(10):951-955
建立了离子转换色谱与紫外检测器联用检测啤酒中无机阴离子与有机酸的新方法。在传统的离子色谱基础上引入两根离子转换柱,无机阴离子与有机酸经过两步转换,定量转换成有相同紫外响应的碘酸盐,然后用紫外检测器代替电导检测器进行定量分析。在Dionex AS11-HC阴离子色谱柱上,采用KOH梯度淋洗方式实现了12种无机阴离子与有机酸的分离。结果表明,12种无机阴离子和有机酸检出限(S/N=3)与定量限(S/N=10)分别为6.168~29.01 μg/L与20.56~66.30 μg/L;线性关系良好(r在0.9994以上),回收率为89.0%~117.0%,RSD均小于1.0%,该方法与传统的电导检测器检测结果相当。该方法简单快捷,只需采用少数标准曲线,就可以实现啤酒中无机离子与有机酸的定量测定。  相似文献   

2.
离子色谱法测定乙二醇中微量有机酸和无机阴离子   总被引:2,自引:0,他引:2  
建立了以YSA-8阴离子交换柱的离子色谱法分析乙二醇中微量有机酸和无机阴离子的方法,比较了进样乙二醇浓度对F-及有机酸测定结果的影响,进样乙二醇质量分数低于8.5%时,能够得到较准确的数据.用本法对所测的有机酸和无机阴离子检出限均在8.9 μg/L以下,线性相关系数r在0.996~0.999范围内,标准样中各物质的离子峰面积的相对标准偏差(RSD)在4.2%以下(n=11),对乙二醇质量分数约为8.5%的样品中F-及有机酸的加标回收率在91.6%~100.0%之间,乙二醇含水料直接测定无机阴离子的加标回收率在91.8%~104.8%之间.  相似文献   

3.
离子交换色谱法同时测定啤酒中有机酸和无机阴离子   总被引:15,自引:2,他引:13  
建立了用亲水性阴离子交换分离柱,KOH为淋洗液等浓度泵作梯度淋洗,电导检测,同时分离和检测16种无机阴离子和低分子量有机酸的离子色谱法。方法对所测无机阴离子和有机酸检出限在9.3~32μg/L之间;线性范围均在2个数量级以上;回收率在90.2%~107.2%之间。方法用于啤酒样品的分析,结果满意,样品的RSD小于5.3%(n=7)。  相似文献   

4.
自Small等首次采用双柱阴离子色谱法测定无机阴离子以来,单柱阴离子色谱法已被用于测定无机阴离子、有机酸,并利用金属阳离子与EDTA形成的阴离子配合物分离测定阳离子。但用单柱阴离子色谱法同时测定无机阴离子、无机阳离子和有机酸尚未见报道。本文采用EDTA为淋洗液的单柱阴离子色谱法研究了无机阴离子、无机阳离子和有机酸的同时分析测定。  相似文献   

5.
有机酸与无机阴离子的梯度离子色谱法分析研究   总被引:17,自引:0,他引:17  
刘  刘克纳  沈冬青  宋强  牟世芬  冯应升 《色谱》1997,15(4):334-337
研究了用离子色谱法梯度洗脱抑制电导检测器分析有机酸与无机阴离子的色谱条件,建立了最佳梯度程序。用阴离子交换分离,选用去离子水、氢氧化钠和甲醇作淋洗液,分别对5种二元有机酸和3种无机阴离子做二元梯度淋洗,对10种多元有机酸和3种无机阴离子做三元梯度淋洗。方法用于果汁饮料与柠檬酸发酵液的测定,结果令人满意。  相似文献   

6.
建立离子色谱梯度淋洗抑制电导法测定电厂水中有机酸和无机阴离子的方法。选用Ion Pac AG11–HC(50 mm×4 mm)阴离子保护柱和Ion Pac AS11–HC(250 mm×4 mm)阴离子分析柱对样品进行分离,以氢氧化钾溶液梯度淋洗,自再生抑制电导检测器检测,同时测定电厂水中的有机酸和无机阴离子。F–,Cl–,NO2–,Br–,NO3–的线性范围为0.005~2 mg/L,CH3COO–,HCOO–,SO42–,PO43–的线性范围为0.01~5 mg/L,各组分线性相关系数为0.998 9~0.999 3,检出限为0.122~0.989 ng/m L,测定结果的相对标准偏差小于2.0%(n=7),样品加标平均回收率为97.9%~101.7%。该方法操作简便,实用性强,可以用于电厂水中有机酸和无机阴离子的检测。  相似文献   

7.
单柱离子色谱法同时分析无机阴离子和有机酸   总被引:6,自引:2,他引:4  
于泓  刘清林  关良智 《色谱》1993,11(2):109-110
1979年Gjerde等提出单柱离子色谱法。用电导检测的单柱阴离子色谱主要用于无机阴离子分析,用于有机酸分析的文献相对较少。本文用邻苯二甲酸氢钾为淋洗液的单柱离子色谱系统,同时分析了六种无机阴离子和四种有机酸。  相似文献   

8.
杨瑞琴  蒋生祥 《分析化学》1998,26(9):1121-1124
采用氯甲基苯乙烯包夹硅胶基质制备出一种新型强阴离子色谱柱填料,该填料具有良好的色谱柱性能,可以较地的分离常见的6种无机阴离子,6种低碳链有机酸以及甲酸,乙酸和一些无机阴离子的混合物。  相似文献   

9.
采用固相萃取-电导抑制离子色谱法测定了萝芙木中常见有机酸和无机阴离子。以Ionpac AS11为分离柱,Ionpac AG11为保护柱,萝芙木样品过IC SPE-C18前处理柱去除杂质和有机物,在确定的色谱条件下,柱温30℃,淋洗液为7.5 mmol/L Na OH溶液,流速为0.7 m L/min,电导检测器-离子色谱法直接测定样品,方法的相关系数在0.9987~0.9999之间,样品回收率在83.0%~100.8%之间,RSD5%。方法适用于中草药中常见有机酸和无机阴离子含量的测定。  相似文献   

10.
曹家兴  杭义萍  陆建平  童张法 《色谱》2010,28(9):893-897
建立了固相萃取-离子色谱测定甘蔗糖蜜及糖蜜酒精废液中乙酸、乳酸、琥珀酸、苹果酸、酒石酸、草酸、富马酸、柠檬酸、乌头酸等非氮有机酸和盐酸根、硫酸根、磷酸根等3种无机阴离子的方法。样品稀释液经强阴离子(SAX)固相萃取小柱净化除去糖类和色素等干扰基质,再用稀KOH溶液洗脱,经0.45 μm水膜过滤后,用IonPac AS15阴离子分离柱、KOH溶液梯度淋洗-抑制电导检测分离分析。考察了固相萃取小柱对待测离子的保留和洗脱条件。实验结果表明,除乙酸和乳酸的分离不完全、苹果酸与琥珀酸的组分重叠外,其余组分可达到完全分离,被测组分的浓度与其峰高在一定的范围呈良好的线性关系,检出限均低于0.20 mg/L,相对标准偏差(RSD)小于6.7%。测定了2种甘蔗糖蜜和1种糖蜜酒精废液中有机酸及无机阴离子,结果满足检测的要求,样品中各组分的加标回收率为94%~109%。  相似文献   

11.
食品中有机酸的高效液相色谱分析法   总被引:35,自引:2,他引:33  
丁明玉  陈培榕  罗国安 《色谱》1997,15(3):212-215
对离子交换色谱法、离子排斥色谱法和反相高效液相色谱法分析食品中有机酸的特色和近几年的研究与应用状况作一综述。  相似文献   

12.
离子色谱法同时分析董酒中的有机酸与无机阴离子   总被引:9,自引:4,他引:5  
丁明玉  陈培榕  罗国安 《色谱》1998,16(1):59-61
研究了用离子色谱法同时分析董酒中可离解性有机酸和无机阴离子。首次采用邻苯二甲酸氢钾和邻苯二甲酸的混合水溶液作淋洗剂,改善了分离效果,提高了检测灵敏度。所建立的方法无需进行样品前处理,无干扰,有一定的实用价值。  相似文献   

13.
An ion chromatographic (IC) method for the determination of six organic acids and three inorganic anions in Bayer liquors was proposed. Formic, acetic, propionic, oxalic, succinic, glutaric acid, F, Cl, and SO 4 2− were separated and determined within 33 min. For the first time, repeatability, reproducibility, and recoveries for the determination of these acids in Bayer liquors were estimated. The analytes were removed from a Bayer liquor by using an ion-exchange resin column. The chromatographic separation was achieved with only one IonPac AS11-HC column thermostated at 30°C. Organic acids and inorganic anions were detected with a suppressed conductance detector. The precision results showed that the relative standard deviations of the repeatability and reproducibility were <2.94 and <1.37%, respectively. The accuracy of the method was confirmed with an average recovery ranging between 86.3 and 105.6%. Under optimum conditions the detection limits ranged from 0.008 to 0.053 mg/L. The text was submitted by the authors in English.  相似文献   

14.
Ultra-short columns for low-pressure ion chromatography.   总被引:3,自引:0,他引:3  
Since the development of low-pressure ion chromatography (LPIC), many inorganic cations and anions as well as organic acids could be analyzed at a low-pressure of 1.96 x 10(5)-2.94 x 10(5) Pa. And the ultra-short columns took the place of the common long chromatographic columns. Furthermore, the ultra-short columns of LPIC not only reduced the system pressure appreciably, but also achieved high sensitivity and precision. In order to assess the characteristics of the super-short columns, much analysis, i.e., the analysis of alkali metals, alkaline earth metals, transition-metals, rare-earth elements, inorganic anions and organic acids as well as the common amino acids, were conducted. Moreover, excellent results were obtained from the LPIC columns.  相似文献   

15.
以自制的6.0μm单分散大孔交联聚氯甲基苯乙烯-二乙烯基苯(Poly(4-vinylbenzylchloride-co-divi-nylbenzene),PCMS/DVB)微球为基质和引发剂,CuCl和自行合成的三[(2-二甲基氨基)乙基]胺(Tris[2-(dimeth-ylamino)ethyl]amine,Me6TREN)组成混合催化体系,使4-乙烯基吡啶(4-Vinyl pyridine,4-VP)在甲苯中进行原子转移自由基聚合,制得4-乙烯基吡啶聚合物,单体4-乙烯基吡啶的接枝率为8.55%。将该聚合物与正溴丁烷反应制得新型亲水色谱固定相。在亲水作用色谱模式下,流速1 mL/min,乙腈-水为流动相可分离5种芳胺化合物和4种酚类化合物。在离子交换色谱模式下,6 mmol/L Na2CO3-5.5 mmol/L NaHCO3为淋洗液可分别分离5种无机阴离子和4种短链有机酸。结果表明,此固定相对极性化合物和无机阴离子具有良好的分离性能,是一种性能优异的亲水作用色谱固定相。  相似文献   

16.
离子色谱作为一种新型高效液相色谱技术, 最初主要应用于测定样品中的阴阳离子含量, 如今发展为应用于有机酸、生物胺、糖类等化合物的组成及含量测定. 离子色谱法具有操作简便、灵敏度高以及选择性好等优点, 因此, 目前离子色谱法已在能源、环境、地质、食品、药物等领域得到了广泛应用. 总结了近年来离子色谱在中药金属离子、无机阴离子、有机酸、糖类成分的研究进展, 为离子色谱法分析中药化学成分提供了参考.  相似文献   

17.
Cao H  Xiao JB 《Annali di chimica》2007,97(1-2):49-58
An Ion Chromatographic (IC) method for the determination of six organic acids and three inorganic anions in alkaline solutions was reported. Formic, acetic, propionic, oxalic, succinic, glutaric acid, F-, Cl-, and SO4(2-) were separated and determined in 33 min. The analytes were removed from Bayer liquor by using an ion-exchange resin column. The chromatographic separation was achieved with only one IonPac AS11-HC column thermostated at 30 degrees C. Organic acids and inorganic anions were detected with a suppressed conductance detector. The precision results' showed that the repeatability and reproducibility were < 2.94 and < 1.37%, respectively. The accuracy of the method was assessed by the recoveries ranging from 86.3 to 105.6%. Under optimum conditions the detection limits ranged from 0.008 to 0.053 mg/l.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号