首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
电化学双电层电容器用新型炭材料及其应用前景   总被引:4,自引:0,他引:4  
张浩  曹高萍  杨裕生  徐斌  张文峰 《化学进展》2008,20(10):1495-1500
活性炭是目前使用最为广泛的一种电化学双电层电容器(EDLC)的电极材料,但其固有的缺点制约了EDLC性能的进一步提高。用新型高性能炭电极材料可使EDLC比能量和比功率性能进一步提高。这些新型炭材料包括基于石墨层状结构的纳米门炭,基于碳纳米管阵列结构的毛皮炭,通过高温置换反应制备的骨架炭以及电极可整体成型的纳米孔玻态炭。本文介绍了这些炭材料的电化学特性及其在电化学双电层电容器中的应用,指出用这4种新型炭材料制备EDLC的比能量或比功率性能远高于目前活性炭基EDLC,具有良好的应用前景。  相似文献   

2.
《Electroanalysis》2005,17(18):1627-1634
The behavior of chloride, bromide and iodide at edge plane pyrolytic graphite electrodes has been explored in aqueous acid solutions. The voltammetric response in each case has been compared with that of basal plane pyrolytic graphite, glassy carbon and boron‐doped diamond. The electrochemical oxidation of chloride is found to only occur on boron‐doped diamond while the electrochemical reversibility for the oxidation of bromide on edge plane pyrolytic graphite is similar to that seen at glassy carbon whilst being superior to basal plane pyrolytic graphite and boron‐doped diamond. In the case of iodide oxidation, edge plane and basal plane pyrolytic graphite and glassy carbon display similar electrode kinetics but are all superior to boron‐doped diamond. The analytical possibilities were examined using the edge plane pyrolytic graphite electrode for both iodide and bromine where is was found that, based on cyclic voltammetry, detection limits in the order of 10?6 M are possible.  相似文献   

3.
陈卫 《电化学》2015,21(6):503
可以预见,在相当一段时期内,能源和环境将是全球发展的两大主题. 其实,人类对能源的获取方式将对地球的生态环境和人类未来的生存状态和生活方式产生重要影响. 正因为如此,世界各国正在大力发展可再生能源和清洁能源. 电化学能源是将化学能高效转变为电能的一种能量转换方式,它历史悠久,但不断被改进和创新,尤其是近年来得到了较快的发展. 目前,电化学能源转换和存储器件主要包括一次电池(如锌锰电池等)、二次电池(如铅酸电池、镍氢电池、锂离子电池等)、燃料电池、金属-空气电池以及超级电容器等. 电化学能源和其它可再生能源相互补充、交叉利用将是未来清洁能源的主要发展方向.  相似文献   

4.
《Electroanalysis》2005,17(17):1529-1533
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon‐based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1×10?5 M and 0.065 A M?1 respectively.  相似文献   

5.
《Electroanalysis》2005,17(8):655-661
The first examples of using edge plane pyrolytic graphite electrodes for anodic and cathodic stripping voltammetry (ASV and CSV) are presented, notably the ASV of silver and the CSV of manganese. In the former example, detection limits for silver (based on 3σ) of 8.1 nM and 0.185 nM for 120 s and 300 s accumulation time, respectively, were achievable using the edge plane electrode, which were superior to those observed on glassy carbon, basal plane pyrolytic graphite and boron‐doped diamond electrodes. In the second example, a detection limit for manganese of 0.3 μM was possible which was comparable with that achievable with a boron‐doped diamond electrode but with an increased sensitivity. Comparison of the edge plane pyrolytic graphite electrode with boron‐doped diamond electrodes reveals that the edge plane electrode has comparable detection limits and sensitivities whilst exhibiting a lower signal‐to‐noise ratio and large potential window for use in trace analysis suggesting boron‐doped diamond can be conveniently replaced by edge plane pyrolytic graphite as an electrode material in many applications.  相似文献   

6.
《Electroanalysis》2006,18(5):449-455
The direct electrochemical oxidation of ammonia in propylene carbonate is reported for the first time. The voltammetric responses at glassy carbon, boron‐doped diamond, edge and basal plane pyrolytic graphite electrodes are explored and compared with the outcome indicating that the optimum electrode substrate for analytical purposes in this solvent is glassy carbon. Proof‐of‐concept is shown for the amperometric detection of ammonia using basal plane pyrolytic graphite electrodes abrasively modified with glassy carbon spheres. Given the significantly lower vapor pressure of propylene carbonate in comparison to water the implications for extending the life‐time of practical sensors are evident. Propylene carbonate shows a wide potential window with glassy carbon electrodes permitting this approach to be used for a potential diversity of gaseous analytes.  相似文献   

7.
The electrochemical behaviour of three purine derivatives was investigated by cyclic voltammetry on different electrode materials: glassy carbon in native form and electrochemically activated, carbon paste electrode unmodified or modified with 1, 4-benzoquinone. The preliminary study obtained on solid electrodes was extended to graphite based planar screen-printed electrodes, unmodified and modified with multi-wall carbon nanotubes, or cobalt phthalocyanine.  相似文献   

8.
The voltammetric responses of chlorine in aqueous acid solutions have been explored using different carbon-based electrodes. Edge-plane pyrolytic graphite has more electrochemical reversibility than glassy carbon, basal-plane pyrolytic graphite, or boron-doped diamond electrodes. A significant reduction in the overpotential is observed on the edge-plane pyrolytic-graphite electrode in contrast with the other carbon-based electrode substrates. These results suggest that edge-plane pyrolytic graphite can be optimally used as the working electrodes in Clark-cell devices for low-potential amperometric gas sensing of Cl2.  相似文献   

9.
The effect of various deposition techniques, electrode materials and posttreatment with tetrabutylammonium and tetrabutylphosphonium salts on the electrochemical behavior and stability of various Prussian blue (PB) modified electrodes, namely PB modified glassy carbon electrodes, silicate‐film supported PB modified glassy carbon electrodes, PB‐doped silicate glassy carbon electrodes, PB modified carbon ceramic electrodes using electrochemical deposition and PB modified carbon ceramic electrodes using chemical deposition is reported. Cyclic voltammetry and amperometric measurements of hydrogen peroxide were performed in a flow injection system while the carrier phosphate buffer (pH 7.0) with a flow rate of 0.8 mL min?1 was propelled into the electrochemical flow through cell housing the PB modified working electrode as well as an Ag|AgCl|0.1 M KCl reference and a Pt auxiliary electrode. The results showed that the deposition procedure, electrode material and posttreatment with additional chemicals can significantly alter the stability and electrochemical behavior of the PB film. Among the studied PB modified electrodes, those based on carbon ceramic electrodes modified with a film of electropolymerized PB showed the best electrochemical stability.  相似文献   

10.
Different graphitic carbon-based electrode materials were evaluated for direct electro-oxidation of clindamycin and electroanalytical parameters such as sensitivity, residual background current, and signal-tobackground current ratio were compared to select the best one for the clindamycin electroanalysis. Such electrode materials include glassy carbon, carbon paste, pyrolytic graphite (edge-plane and basal-plane), carbon nanotube, reduced graphene oxide, and carbon black. The edge-plane pyrolytic graphite electrode after a simple and fast electrochemical pretreatment showed superior performance compared with the other carbon electrodes. Raman and Fourier transform infrared spectroscopy were employed to analyze the surface microstructure and chemical bonding of the carbon materials and scanning electron microscopy was used to study their surface morphologic features. The applicability of the electrochemically activated edge-plane pyrolytic graphite electrode for the determination of clindamycin in pharmaceutical formulations and human urine samples was evaluated.  相似文献   

11.
Guo K  Qian K  Zhang S  Kong J  Yu C  Liu B 《Talanta》2011,85(2):1174-1179
Characterization and application of graphene sheets modified glassy carbon electrodes (graphene/GC) have been presented for the electrochemical bio-sensing. A probe molecule, potassium ferricyanide is employed to study the electrochemical response at the graphene/GC electrode, which shows better electron transfer than graphite modified (graphite/GC) and bare glassy carbon (GC) electrodes. Based on the highly enhanced electrochemical activity of NADH, alcohol dehydrogenase (ADH) is immobilized on the graphene modified electrode and displays a more desirable analytical performance in the detection of ethanol, compared with graphite/GC or GC based bio-electrodes. It also exhibits good performance of ethanol detection in the real samples. From the results of electrochemical investigation, graphene sheets with a favorable electrochemical activity could be an advanced carbon electrode materials for the design of electrochemical sensors and biosensors.  相似文献   

12.
Salimi A  Mamkhezri H  Hallaj R 《Talanta》2006,70(4):823-832
A sol-gel carbon composite electrode (CCE) has been prepared by mixing a sol-gel precursor (e.g. methyltrimethoxysilane) and carbon powder without adding any electron transfer mediator or specific reagents. It was demonstrated that this sensor can be used for simultaneous determination ascorbic acid, neurotransmitters (dopamine and adrenaline) and uric acid. Direct electrochemical oxidation of ascorbic acid, uric acid and catecholamines at a carbon composite electrode was investigated. The experimental results were compared with other common carbon based electrodes, specifically, boron doped diamond, glassy carbon, graphite and carbon paste electrodes. It was found that the CCE shows a significantly higher of reversibility for dopamine. In addition, in comparison to the other electrodes used, for CCE the oxidation peaks of uric acid, ascorbic acid and catecholamines in cyclic and square wave voltammetry were well resolved at the low positive potential with good sensitivity. The advantages of this sensor were high sensitivity, inherent stability and simplicity and ability for simultaneous determination of uric acid, catecholamines and ascorbic acid without using any chromatography or separation systems. The analytical performance of this sensor has been evaluated for detection of biological molecules in urine and serum as real samples.  相似文献   

13.
The research on electrochemical double layer capacitors (EDLC), also known as supercapacitors or ultracapacitors, is quickly expanding because their power delivery performance fills the gap between dielectric capacitors and traditional batteries. However, many fundamental questions, such as the relations between the pore size of carbon electrodes, ion size of the electrolyte, and the capacitance have not yet been fully answered. We show that the pore size leading to the maximum double-layer capacitance of a TiC-derived carbon electrode in a solvent-free ethyl-methylimmidazolium-bis(trifluoro-methane-sulfonyl)imide (EMI-TFSI) ionic liquid is roughly equal to the ion size (approximately 0.7 nm). The capacitance values of TiC-CDC produced at 500 degrees C are more than 160 F/g and 85 F/cm(3) at 60 degrees C, while standard activated carbons with larger pores and a broader pore size distribution present capacitance values lower than 100 F/g and 50 F/cm(3) in ionic liquids. A significant drop in capacitance has been observed in pores that were larger or smaller than the ion size by just an angstrom, suggesting that the pore size must be tuned with sub-angstrom accuracy when selecting a carbon/ion couple. This work suggests a general approach to EDLC design leading to the maximum energy density, which has been now proved for both solvated organic salts and solvent-free liquid electrolytes.  相似文献   

14.
The research of anodic materials which could improve the performance and reduce the cost of graphite-based materials in lithium-ion batteries leads to a considerable effort for creating novel carbons. In this work, special attention has been paid to investigating the possibility of improving the electrochemical behavior of graphite anode by application of composite materials with carbon materials coming from agro-wastes. For that, different carbons coming from agro-wastes have been synthesized and characterized in order to study the effect of their properties on the electrochemical performance of C/C composites with graphite. It has been established that introduction of hard carbon obtained from olive stones into the active mass of anode based on graphite allows one to increase the reversible capacity up to 405 mAh g?1 for the total mass of graphite/carbon content of electrode, and also to improve stability of characteristics during cycling. We suggested that such a binary carbon mixture (graphite and hard carbon) would be a better choice for development of the anode for lithium-ion battery.  相似文献   

15.
Fouling of electrode surfaces by electrode reaction products or by biological spectator species is known to inactivate electrochemical sensors and thus limit their use in biological conditions. Here we present an investigation on the stability of boron doped diamond (BDD) electrodes with different levels of doping. Three different doping levels were used (0.1, 1 and 5% in the carbon phase). The highly doped (5%) BDD is of particular interest as it is here used for the first time for biological applications. Three different redox reactions were examined based on their electrode reaction characteristics: ruthenium(III) hexaammine (outer sphere), ferrocyanide (surface dependent), dopamine (adsorption mediated). The effect of albumin at blood concentration was studied. All results were compared with glassy carbon. There were no significant differences for the outer sphere electrochemistry, but all the BDDs showed improved resistance to fouling for the ferrocyanide oxidation. The electrocatalytic activity of BBD towards dopamine oxidation increased with increased boron content. However, this appears to be due to a larger number of defect sites which also increases the vulnerability to fouling by albumin and by electrode reaction products and the 5% BDD had similar properties to glassy carbon in this regard. These results suggest that it is possible to optimise the BDD performance for specific applications and that the large potential window for BDD may be due, at least in part, to its relatively poor electrocatalytic activity.  相似文献   

16.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

17.
《Electroanalysis》2005,17(4):305-311
Boron‐doped diamond thin‐film electrodes display negligible fouling effects in the presence of high levels of surface‐active materials, including proteins. Dramatic improvements in the stability of the analyte response (compared to common glassy carbon and carbon paste electrodes) are illustrated using bovine serum albumin (BSA), gelatin, and Triton X‐100 in connection with repetitive square‐wave voltammetric (SWV) measurements. The voltammetric response of ascorbic acid at the diamond electrode exhibits negligible shifts in peak potentials and minimal depressions of current signals over a wide range of surfactant concentrations (0–750 ppm). For example, the diamond electrode exhibited 70, 50 and 60 mV potential shifts for 10 repetitive voltammetric scans in the presence of 100 ppm BSA, gelatin and Triton X‐100, respectively, compared to 120, 190, and 280 mV shifts observed at the glassy carbon electrode. Furthermore, only 4.3 and 6.2% of the initial current decays were observed in the presence of 100 ppm Triton X‐100 and gelatin, respectively (compared to 45.2 and 34.4% diminutions at the glassy carbon electrode). Such improved performance was also confirmed from the SWV measurements of uric acid, dihydroxyphenylacetic acid, and catechol. The greatly improved resistance to surfactant interference reflects the fact that the as‐grown diamond thin film, composed of oxide‐free and hydrogen‐terminated surface, has a relatively lower surface energy and minimal electrostatic attributes, either specific or general, so that little adsorption of surface‐active agents occurs. The topographic AFM images of the diamond electrode surface confirm a negligible BSA fouling effect after repetitive SWV measurements. Such enhanced antifouling features make diamond electrodes very attractive for numerous real‐life electroanalytical applications.  相似文献   

18.
Carbon electrodes are a key factor for electric double layer capacitors (EDLCs). Carbon gels have high porosity with a controllable pore structure by changing synthesis conditions and modifying preparation processing to improve the electrochemical performance of EDLCs. This review summarizes the preparation of carbon gels and their derivatives, the criteria to synthesize high surface area in each process, the development by some carbon forms, and EDLC applications. Porous carbons are also prepared as model materials by concentrating on how pore structure increases electrochemical capacitance, such as electronic and ion resistance, the tortuosity of pore channel, suitable micropore and mesopore sizes, and mesopore size distribution. This review emphasizes the significance of pore structures as the key factor to allow for the design of suitable pore structures that are suitable as the carbon electrode for EDLCs.  相似文献   

19.
The voltammetric response of nitrogen dioxide in aqueous sulfuric acid using an edge plane pyrolytic graphite electrode has been explored and contrasted with that from basal plane pyrolytic graphite, glassy carbon or boron-doped diamond electrodes. Edge plane graphite electrode is found to produce an excellent voltammetric signal in comparison with other carbon-based electrodes exhibiting a well-defined analytically useful voltammetric redox couple in 2.5 M sulfuric acid which is absent on the alternative electrodes.  相似文献   

20.
The electrochemical generation of nitrosophenyl groups covalently attached to graphite powder (nitrosophenylcarbon) from carbon powder chemically modified with nitrophenyl groups and their subsequent reaction with thiols (glutathione, cysteine and homocysteine) has been investigated as a method by which the later can be quantified. The modified carbon powder was immobilized onto a basal plane pyrolytic graphite electrode and characterized by cyclic voltammetry by scanning between 1.0 V and ?1.0 V vs. SCE in phosphate buffer (pH 7). Square wave voltammetry (SWV) was used for the determination of thiols and the SWV parameters were optimized. The nitrosophenylcarbon is electrogenerated from nitrophenylcarbon and can chemically oxidize thiols to disulfides. Subsequent reduction of nitrosophenylcarbon to phenylhydroxylaminecarbon during the square wave voltammetric process leads to a decrease in the reductive current. This can be correlated to the concentration of thiol present within the medium. The cyclic voltammetric responses of basal plane pyrolytic graphite electrode, edge plane pyrolytic graphite electrode, glassy carbon electrode and boron‐doped diamond electrode in the direct oxidation of thiols were also investigated and all were found to have a significantly higher overpotential compared to the described method using nitrosophenylcarbon.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号