首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Li Y  DeVoe DL  Lee CS 《Electrophoresis》2003,24(1-2):193-199
Isoelectric focusing (IEF) separations, in general, involve the use of the entire channel filled with a solution mixture containing protein/peptide analytes and carrier ampholytes for the creation of a pH gradient. Thus, the preparative capabilities of IEF are inherently greater than most microfluidics-based electrokinetic separation techniques. To further increase sample loading and therefore the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from solution reservoirs, is demonstrated in this study. The proteins/peptides continuously migrate into the plastic microchannel and encounter a pH gradient established by carrier ampholytes originally present in the channel for focusing and separation. Dynamic sample introduction and analyte focusing in plastic microfluidic devices can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Under the influence of 30 min electrokinetic injection at constant electric field strength of 500 V/cm, the sample loading is enhanced by approximately 10-100 fold in comparison with conventional IEF.  相似文献   

2.
We have developed novel protein gel electrophoresis techniques, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and isoelectric focusing (IEF) in short microchannels (approximately millimeters) that take less than a minute. A photopatterning technique was used to cast in situ crosslinked polyacrylamide gel in a microchannel to perform SDS-PAGE. A fluorescent protein marker sample (Mr range of 20,000-200,000) was separated in less than 30 s in less than 2 mm of channel length. Crosslinked polyacrylamide gel, patterned in channels using UV light, provides higher sieving power and sample stacking effect, therefore yielding faster and higher-resolution separation in a chip. IEF of proteins was also achieved in a microchannel, and several proteins were focussed within tens of seconds in mm-length channels. As resolution in IEF is independent of separation distance, focusing in ultra-short channels results in not only faster separation but also more concentrated bands potentially allowing detection of low-concentration species.  相似文献   

3.
Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8‐fold.  相似文献   

4.
Shim J  Dutta P  Ivory CF 《Electrophoresis》2008,29(5):1026-1035
The effects of mobility corrections on carrier ampholytes are studied at various ampholyte concentrations to understand protein behavior during IEF. IEF simulations are conducted in the presence of 25 biprotic carrier ampholytes within a pH range of 6-9 after applying the Onsager-Debye-Hückel correction to the carrier ampholytes. Two model proteins with ten charge states but without ionic strength corrections are allowed to focus under an electric field of 300 V/cm in a 1 cm long channel. The IEF simulation results show that higher ionic strengths (50 - 100 mM) cause significant changes in the transient movement as well as the final focused profiles of both ampholytes and proteins. The time required for a single, well-defined peak to form increases with ionic strength when Onsager corrections are applied to the carrier ampholytes. For a particular ampholyte concentration, the space-averaged conductivity does not change during the final focusing stage, but the magnitude of space averaged conductivity is different for different ampholyte concentration. The simulation results also reveal that at steady-state ionic strength profiles remain flat throughout the channel except at the locations of proteins where a significant change in ampholyte concentration is obtained.  相似文献   

5.
A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.  相似文献   

6.
Zuo X  Speicher DW 《Electrophoresis》2000,21(14):3035-3047
In this study, metabolically radiolabeled Escherichia coli cell extracts were used to systematically evaluate protein recoveries at each step of two-dimensional (2-D) electrophoresis and using different sample application methods. Sample application using sample cups resulted in better protein recovery compared with sample loading by rehydration when the Multiphor system was used. At least 50% or more of an E. coli extract was lost when high protein amounts (500 microg) were loaded by rehydration using this system, which employs separate holders for rehydration and isoelectric focusing (IEF). In contrast, when the IPGphor system was used, rehydration sample loading consistently yielded the highest overall protein recoveries. These improved protein recoveries were due to integration of rehydration and electrophoretic separation in a single unit. Even at high protein loads (500 microg), less than 15-20% of the proteins were lost when proteins were loaded by rehydration using sample buffer containing 2% carrier ampholytes in the ceramic immobilized pH gradient (IPG) strip holders used for both rehydration and IEF. Regardless of the loading conditions used, carrier ampholytes in the sample buffer increased protein recoveries. Use of thiourea did not significantly affect protein recoveries but did improve protein resolution in 2-D gels as expected. In summary, these results show the best protein recoveries are obtained for all protein loads when samples are applied to IPG strips during rehydration using a single device for both rehydration and IEF. In contrast, the poorest recoveries are obtained when rehydration and IEF are performed in separate devices, and losses increase dramatically with increasing protein loads using this approach.  相似文献   

7.
Wang Y  Lin Q  Mukherjee T 《Lab on a chip》2004,4(5):453-463
This paper presents a system-oriented model for analyzing the dispersion of electrophoretic transport of charged analyte molecules in a general-shaped microchannel, which is represented as a system of serially connected elemental channels of simple geometry. Parameterized analytical models that hold for analyte bands of virtually arbitrary initial shape are derived to describe analyte dispersion, including both the skew and broadening of the band, in elemental channels. These models are then integrated to describe dispersion in the general-shaped channel using appropriate parameters to represent interfaces of adjacent elements. This lumped-parameter system model offers orders-of-magnitude improvement in computational efficiency over full numerical simulations, and is verified by results from experiments and numerical simulations. The model is used to perform a systematic parametric study of serpentine channels consisting of a pair of complementary turn microchannels, and the results indicate that dispersion in a particular turn can contribute to either an increase or decrease of the overall band broadening. The efficiency and accuracy of the system model is further demonstrated by its application to general-shaped channels that occur in practice, including a serpentine channel with multiple complementary turns and a multi-turn spiral-shaped channel. The results indicate that our model is an accurate and efficient simulation tool useful for designing optimal electrophoretic separation microchips.  相似文献   

8.
A fully integrated polydimethylsiloxane (PDMS)/modified PDMS membrane/SU-8/quartz hybrid chip was developed for protein separation using isoelectric focusing (IEF) mechanism coupled with whole-channel imaging detection (WCID) method. This microfluidic chip integrates three components into one single chip: (i) modified PDMS membranes for separating electrolytes in the reservoirs from the sample in the microchannel and thus reducing pressure disturbance, (ii) SU-8 optical slit to block UV light (below 300?nm) outside the channel aiming to increase detection sensitivity, and (iii) injection and discharge capillaries for continuous operation. Integration of all these components on a single chip is challenging because it requires fabrication techniques for perfect bonding between different materials and is prone to leakage and blockage. This study has addressed all the challenges and presented a fully integrated chip, which is more robust with higher sensitivity than the previously developed IEF chips. This chip was tested by performing protein and pI marker separation. The separation results obtained in this chip were compared with that obtained in commercial cartridges. Side-by-side comparison validated the developed chip and fabrication techniques.  相似文献   

9.
Our dynamic capillary electrophoresis model which uses material specific input data for estimation of electroosmosis was applied to investigate fundamental aspects of isoelectric focusing (IEF) in capillaries or microchannels made from bare fused-silica (FS), FS coated with a sulfonated polymer, polymethylmethacrylate (PMMA) and poly(dimethylsiloxane) (PDMS). Input data were generated via determination of the electroosmotic flow (EOF) using buffers with varying pH and ionic strength. Two models are distinguished, one that neglects changes of ionic strength and one that includes the dependence between electroosmotic mobility and ionic strength. For each configuration, the models provide insight into the magnitude and dynamics of electroosmosis. The contribution of each electrophoretic zone to the net EOF is thereby visualized and the amount of EOF required for the detection of the zone structures at a particular location along the capillary, including at its end for MS detection, is predicted. For bare FS, PDMS and PMMA, simulations reveal that EOF is decreasing with time and that the entire IEF process is characterized by the asymptotic formation of a stationary steady-state zone configuration in which electrophoretic transport and electroosmotic zone displacement are opposite and of equal magnitude. The location of immobilization of the boundary between anolyte and most acidic carrier ampholyte is dependent on EOF, i.e. capillary material and anolyte. Overall time intervals for reaching this state in microchannels produced by PDMS and PMMA are predicted to be similar and about twice as long compared to uncoated FS. Additional mobilization for the detection of the entire pH gradient at the capillary end is required. Using concomitant electrophoretic mobilization with an acid as coanion in the catholyte is shown to provide sufficient additional cathodic transport for that purpose. FS capillaries dynamically double coated with polybrene and poly(vinylsulfonate) are predicted to provide sufficient electroosmotic pumping for detection of the entire IEF gradient at the cathodic column end.  相似文献   

10.
Xu Z  Okabe N  Arai A  Hirokawa T 《Electrophoresis》2010,31(21):3558-3565
This paper reports the protein analysis by using microchip IEF carried on an automated chip system. We herein focused on two important topics of microchip IEF, the pH gradient and cathodic drift. The computer simulation clarified that the EOF could delay the establishment of pH gradient and move the carrier ampholytes (CAs) to cathode, which probably caused a cathodic drift to happen. After focusing, the peak positions of components in a calibration kit with broad pI were plotted against their pI values to know the actual pH gradient in a microchannel varying time. It was found that the formed pH gradient was stable, not decayed after readily steady state, and migrated to cathode at a rate of 10.0 μm/s that determined by the experimental conditions such as chip material, internal surface coating and field strength. The theoretical pH gradient was parallel with the actual pH gradient, which was demonstrated in two types of microchip with different channel lengths. No compression of pH gradient was observed when 2% w/v hydroxypropyl methyl cellulose was added in sample and electrolytes. The effect of CAs concentration on current and cathodic drift was also explored. With the current automatic chip system, the calculated peak capacity was 23–48, and the minimal pI difference was 0.20–0.42 for the used single channel microchip with the effective length of 40.5 mm. The LOD for the analysis of CA‐I and CA‐II was around 0.32 μg/mL by using normal imaged UV detection, the detected amount is ca. 0.07 ng.  相似文献   

11.
In microchannel flow, gas-liquid interface behavior is important for developing a wide range of microfluidic applications, especially in passive microfluidic systems. This paper presents a discussion of interface motion driven by capillary action in a microchannel. We have extended the theory beyond the previous theory of capillary rise problem for a circular tube, to a rectangular microchannel. The same formula for the relation between nondimensional time and interface position is obtained as for a circular tube. We examined rectangular microchannels with several sizes (about 50 to 100 microm square) of glass capillaries and 85 x 68 microm and 75 x 45 microm polydimethylsiloxane (PDMS) microchannels fabricated by photolithography technique, respectively. We observed movement of the gas-liquid interface position and compared it to the dimensionless relation. We obtained the value of a dimensionless variable of driving force that is related to dynamic contact angles for glass-water, glass-ethanol, and PDMS-ethanol. Using this variable, interface motion can be predicted for any size of rectangular channels.  相似文献   

12.
Chemical mobilization following IEF enables single‐point detection of an ideally stationary equilibrium electrophoresis mode. Despite prior studies exploring optimization of chemical mobilization conditions and recent insight from numerical simulations, understanding of both chemical mobilization mechanisms and the implications of mobilization on IEF analytical performance remains limited. In this study, we utilize full‐field imaging of microchannel IEF to assess the performance of a range of canonical chemical mobilization schemes. We empirically demonstrate and characterize key areas where limited understanding of performance implications exists, including: the effects of mobilization solution pH and ion concentration, differences between ionic and zwitterionic mobilization, and diffusion as a source of zone broadening. We utilize Simul5 simulations to gain insight into the sources of the measured performance differences. Measurements of the location, linearity, and slope of the IEF pH gradient (via fluorescent pH markers imaged before and during mobilization) as well as mobilization‐associated broadening of focused analytes were performed to quantify performance and determine the dominant sources of variability. Our results suggest that nonuniform broadening of the pH gradient and changes in the pH gradient linearity stem from conductivity nonuniformities in the separation channel and not diffusion‐associated band broadening during mobilization.  相似文献   

13.
Kates B  Ren CL 《Electrophoresis》2006,27(10):1967-1976
IEF is a high-resolution separation method taking place in a medium with continuous pH gradients, which can be set up by applying electrical field to the liquid in a diverging microchannel. The axial variation of the channel cross-sectional area will induce nonuniform Joule heating and set up temperature gradient, which will generate pH gradient when proper medium is used. In order to operationally control the thermally generated pH gradients, fundamental understanding of heat transfer phenomena in microfluidic chips with diverging microchannels must be improved. In this paper, two 3-D numerical models are presented to study heat transfer in diverging microchannels, with static and moving liquid, respectively. Through simulation, the temperature distribution for the entire chip has been revealed, including both liquid and solid regions. The model for the static liquid scenario has been compared with published results for validation. Parametric studies have showed that the channel geometry has significant effects on the peak temperature location, and the electrical conductivity of the medium and the wall boundary convection have effects on the generated temperature gradients and thus the generated pH gradients. The solution to the continuous flow model, where the medium convection is considered, shows that liquid convection has significant effects on temperature distribution and the peak temperature location.  相似文献   

14.
A capillary chromatography system has been developed using a ternary mixed‐solvents solution, i.e. water–hydrophilic/hydrophobic organic solvent mixture as a carrier solution. Here, we tried to carry out the chromatographic system on a microchip incorporating the open‐tubular microchannels. A model analyte solution of isoluminol isothiocyanate (ILITC) and ILITC‐labeled biomolecule was injected to the double T‐junction part on the microchip. The analyte solution was delivered in the separation microchannel (40 μm deep, 100 μm wide, and 22 cm long) with the ternary water–ACN–ethyl acetate mixture carrier solution (3:8:4 volume ratio, the organic solvent rich or 15:3:2 volume ratio, the water‐rich). The analyte, free‐ILITC and labeled BSA mixture, was separated through the microchannel, where the carrier solvents were radially distributed in the separation channel generating inner and outer phases. The outer phase acts as a pseudo‐stationary phase under laminar flow conditions in the system. The ILITC and the labeled BSA were eluted and detected with chemiluminescence reaction.  相似文献   

15.
Wang L  Flanagan LA  Monuki E  Jeon NL  Lee AP 《Lab on a chip》2007,7(9):1114-1120
A novel dielectrophoresis switching with vertical electrodes in the sidewall of microchannels for multiplexed switching of objects has been designed, fabricated and tested. With appropriate electrode design, lateral DEP force can be generated so that one can dynamically position particulates along the width of the channel. A set of interdigitated electrodes in the sidewall of the microchannels is used for the generation of non-uniform electrical fields to generate negative DEP forces that repel beads/cells from the sidewalls. A countering DEP force is generated from another set of electrodes patterned on the opposing sidewall. These lateral negative DEP forces can be adjusted by the voltage and frequency applied. By manipulating the coupled DEP forces, the particles flowing through the microchannel can be positioned at different equilibrium points along the width direction and continue to flow into different outlet channels. Experimental results for switching biological cells and polystyrene microbeads to multiple outlets (up to 5) have been achieved. This novel particle switching technique can be integrated with other particle detection components to enable microfluidic flow cytometry systems.  相似文献   

16.
The applicability of glass chips with powder-blasted microchannels for electrophoretic separations was examined, and the performance was compared to microchannels etched with hydrogen fluoride (HF), using bicarbonate buffer and rhodamine B and fluorescein as model compounds. The measured electroosmotic mobilities in all chips were comparable, with values of ca. 7 x 10(-4) cm(2) V(-1)s(-1). The effect of electrical field strength and detection length on the separation efficiency was monitored. It was found that the main source of dispersion is of the Taylor-Aris type, which was discussed in relation to channel roughness differences. Although in powder-blasted channels with a separation length of 8.20 cm, 7-9 times lower plate numbers were obtained than in a HF-etched channel with similar dimensions, successful separation of five fluorescein isothiocyanate (FITC)-labeled amino acids was obtained on a powder-blasted chip within 80 s. Efficiencies of up to 360 000 plates/m were demonstrated on this chip, when a higher buffer concentration was used at a field strength of 664 V/cm. It can be concluded that powder-blasted microchannel chips, although they have a lower separation efficiency compared to HF-etched chips, perform well enough for many applications. Powder blasting can therefore be considered a low-cost and efficient alternative to HF etching, in particular because of the possibility to fabricate access holes through the glass with the same process.  相似文献   

17.
在通道壁面垂直施加一个调控电场可以改变双电层电荷密度和Zeta电位势,实现对电渗流的调控.采用电场Poisson方程、动量守恒的Navier-Stokes方程、电解质离子输运的Nernst-Planck方程和液体混合反应的组分浓度输运方程,本文对微通道壁面离散布置调控电极的情况进行了数值分析.数值算例包括单电极、双电极...  相似文献   

18.
Yan D  Yang C  Nguyen NT  Huang X 《Electrophoresis》2006,27(3):620-627
The zeta potentials of channel surfaces and tracer particles are of importance to the design of electrokinetic microfluidic devices, the characterization of channel materials, and the quantification of the microparticle image velocimetry (microPIV) measurement of EOFs. A method is proposed to simultaneously measure the zeta potentials of the channel surface and the tracer particles in aqueous solutions using the microPIV technique. Through the measurement of the steady velocity distributions of the tracer particles in both open- and closed-end rectangular microchannels under the same water chemistry condition, the electrophoretic velocity of the tracer particles and the EOF field of the microchannel are determined using the expressions derived in this study for the velocity distributions of charged tracer particles in the open- and closed-end rectangular microchannels. Thus, the zeta potentials of the tracer particles and the channel surfaces are simultaneously obtained using the least-square method to fit the microPIV measured velocity distribution of the tracer particles. Measurements were carried out with a microPIV system to determine the zeta potentials of the channel wall and the fluorescent tracer particles in deionized water and sodium chloride and boric acid solutions of various concentrations.  相似文献   

19.
Wang Y  Lin Q  Mukherjee T 《Lab on a chip》2004,4(6):625-631
This paper presents an analytical and parameterized model for analyzing the effects of Joule heating on analyte dispersion in electrophoretic separation microchannels. We first obtain non-uniform temperature distributions in the channel resulting from Joule heating, and then determine variations in electrophoretic velocity, based on the fact that the analyte's electrophoretic mobility depends on the buffer viscosity and hence temperature. The convection-diffusion equation is then formulated and solved in terms of spatial moments of the analyte concentration. The resulting model is validated by both numerical simulations and experimental data, and holds for all mass transfer regimes, including unsteady dispersion processes that commonly occur in microchip electrophoresis. This model, which is given in terms of analytical expressions and fully parameterized with channel dimensions and material properties, applies to dispersion of analyte bands of general initial shape in straight and constant-radius-turn channels. As such, the model can be used to represent analyte dispersion in microchannels of more general shape, such as serpentine- or spiral-shaped channels.  相似文献   

20.
《Electrophoresis》2018,39(8):1040-1047
Isoelectric focusing (IEF) is a powerful separation method, useful for resolving subtle changes in the isoelectric point of unlabeled proteins. While microfluidic IEF has reduced the separation times from hours in traditional benchtop IEF to minutes, the enclosed devices hinder post‐separation access to the sample for downstream analysis. The two‐layer open IEF device presented here comprises a photopatterned hydrogel lid layer containing the chemistries required for IEF and a thin polyacrylamide bottom layer in which the analytes are separated. The open IEF device produces comparable minimum resolvable difference in isoelectric point and gradient stability to enclosed microfluidic devices while providing post‐separation sample access by simple removal of the lid layer. Further, using simulations, we determine that the material properties and the length of the separation lanes are the primary factors that affect the electric field magnitude in the separation region. Finally, we demonstrate self‐indexed photomasks for alignment‐free fabrication of multi‐domain hydrogels. We leverage this approach to generate arrayed pH gradients with a total of 80 concurrent separation lanes, which to our knowledge is the first demonstration of multiple IEF separations in series addressed by a single pair of electrodes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号