首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
A rapid method for analyzing brominated flame retardants (BFRs) was developed using direct exposure probe/mass spectrometry (DEP/MS). The BFRs used in this study included 1,2-bis(pentabromophenyl)ethane (EBP), tetrabromobisphenol A (TBBPA), and hexabromocyclododecane (HBCD), which are included in the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS).Quantitative analysis was conducted using octabromodiphenyl ether (octa-BDE), nonabromodiphenyl ether (nona-BDE), and decabromodiphenyl ether (deca-BDE). The samples were extracted by ultrasonication, following which the diluted sample solutions were analyzed by DEP/MS. Finally, the characteristic ions in the mass spectra of BFRs were identified.The limit of detection (LOD) and limit of quantification (LOQ) for deca-BDE were 0.163 and 0.495 mg/kg, respectively. The calibration curve showed a linearity (R2 = 0.9984) within 0.5-16 μg/mL. The relative standard deviation ranged from 2.78% to 6.76%. The octa-BDE and nona-BDE samples showed similar results. Finally, the certified reference material (CRM, NMIJ CRM 8108-a, Japan) for the deca-BDE analysis was used, and the recovery was 96.4%.  相似文献   

2.
《中国化学快报》2022,33(8):3849-3852
Owing to frequent environmental monitoring of tetrabromobisphenol-A (TBBPA) analogs and their potential ecotoxicological effects on organisms, analysis of trace levels of TBBPA analogs with more non-polar and less water-soluble characteristics is of great significance for studying their environmental behaviors and toxic effects. Herein, a fast and sensitive technique is developed for directly detecting aqueous TBBPA analogs, including TBBPA mono(allyl ether) (TBBPA-MAE), TBBPA mono(2,3-dibromopropyl ether) (TBBPA-MDBPE), TBBPA mono(2-hydroxyethyl ether) (TBBPA-MHEE) and TBBPA mono(glycidyl ether) (TBBPA-MGE), by combining solid phase microextraction (SPME) based on porous covalent organic frameworks (Porous-COFs) with constant flow desorption ionization-mass spectrometry (CFDI-MS). As chromatographic separation is replaced by constant flow desorption, each sample can be analyzed within 7 min. The hierarchical porous structures (microporous, mesoporous and macroporous) of COFs lead to the enhanced mass transfer and the easier accessibility of active sites to TBBPA analogs, so that the extraction efficiency is 2.3–3.6 times higher than pure microporous COFs, and far superior to commercial coatings. The detection limit and quantification limit of this method are 0.1–1 and 0.4–3.2 ng/L, respectively. Ultra-trace levels of TBBPA analogs from 5.0 ng/L to 66 ng/L have been successfully detected in river and sea water samples, showing great potential for subsequent studies of their environmental behaviors and toxicological effects  相似文献   

3.
Xiao Z  Feng J  Shi Z  Li J  Zhao Y  Wu Y 《色谱》2011,29(12):1165-1172
建立了固相萃取同时提取、净化血清中四溴双酚A(TBBPA)、α, β, γ-六溴环十二烷(HBCD)和8种多溴联苯醚(PBDEs)同系物的样本前处理方法,并结合色谱-质谱分离分析技术检测人血清样本中该类化合物的含量。试样在加入各自的同位素内标物后以甲基叔丁基醚/正己烷(1:1, v/v)混合溶剂进行萃取,再经浓硫酸去除脂肪后,以LC-Si固相萃取柱分离HBCD/TBBPA和PBDEs。采用分步检测的方式,在50 mm长BEH C18反相色谱柱上以超高效液相色谱-串联质谱(UPLC-MS/MS)的多反应监测模式(MRM)检测HBCD和TBBPA,在15 m长的毛细管柱上以气相色谱-负化学源质谱(GC-NCI/MS)的选择离子监测模式(SIM)检测PBDEs。以胎牛血清为空白基质,当HBCD、TBBPA和BDE-209的加标水平为0.5 ng/g和5 ng/g、三溴至七溴联苯醚的加标水平为0.05 ng/g和0.5 ng/g时,它们的平均加标回收率为80.3%~108.8%,相对标准偏差为1.02%~11.42%(n=5);以信噪比(S/N)为3计算,方法的检出限(LOD)为1.81~42.16 pg/g。采用该方法对实际样品进行测定,结果表明,本方法快速、准确、灵敏度高,能够满足血清中HBCD、TBBPA和PBDEs残留的同时提取及测定的要求。  相似文献   

4.
A method has been developed and validated for the concurrent extraction, clean‐up, and analysis of polybrominated diphenyl ethers (PBDEs), α‐, β‐, and γ‐hexabromocyclododecane (HBCD), and tetrabromobisphenol A (TBBPA) in human milk and serum. Milk and serum samples were extracted using accelerated solvent extraction with acetone/hexane 1:1, v/v and liquid–liquid extraction with methyl‐tert‐butyl ether/hexane 1:1, v/v, respectively. The removal of co‐extracted biogenic materials was achieved by gel permeation chromatography followed by sulfuric acid treatment. The fractionation of the PBDEs and HBCD/TBBPA was performed using a Supelco LC‐Si SPE cartridge. The detection of the PBDEs was then performed by GC–MS and that of the HBCDs and the TBBPA was performed using UPLC–MS/MS. The pretreatment procedure was optimized, and the characteristic ions and fragmentation of the analytes were studied by MS or MS/MS. A recovery test was performed using a matrix spiking test at concentrations of 0.05–10 ng/g. The recoveries ranged from 78.6–108.8% with RSDs equal to or lower than 14.04%. The LODs were 1.8–60 pg/g. The usefulness of the developed method was tested by the analysis of real human samples, and several brominated flame retardants in different samples were detected and analyzed.  相似文献   

5.
Two kinds of mesoporous cellular foams (MCFs), including mesoporous silica materials (MCF-1) and phenyl modified mesoporous materials (Ph-MCF-1), were synthesized and for the first time used as fiber-coating materials for solid-phase microextraction (SPME). By using stainless steel wire as the supporting core, four types of fibers were prepared by sol–gel method and immobilized by epoxy-resin method. To evaluate the performance of the home-made fibers for SPME, seven brominated flame retardants (BFRs), including tetrabromobisphenol A (TBBPA), tetrabromobisphenol S (TBBPS) and related compounds were selected as analytes. The main parameters that affect the extraction and desorption efficiencies, such as extraction temperature, extraction time, desorption time, stirring rate and ionic strength of samples were investigated and optimized. The optimized SPME coupled with high performance liquid chromatography (HPLC) was successfully applied to the determination of the seven BFRs in water samples. The linearity range was from 5.0 to 1000 μg L−1 for each compound except TBBPS (from 1.0 to 1000 μg L−1), with the correlation coefficients (r2) ranging from 0.9993 to 0.9999. The limits of detection of the method were 0.4–0.9 μg L−1. The relative standard deviations varied from 1.2 to 5.1% (n = 5). The repeatability of fiber-to-fiber and batch-to-batch was 2.5–6.5% and 3.2–6.7%. The recoveries of the BFRs from aqueous samples were in the range between 86.5 and 103.6%. Compared with three commercial fibers (100 μm PDMS, 85 μm PA and 65 μm PDMS/DVB), the MCFs-coated fiber showed about 3.5-fold higher extraction efficiency.  相似文献   

6.
The aim of this work was to develop procedures for the simultaneous determination of selected brominated flame retardants (BFRs) in river water and in river bed sediment. The target analytes were polybrominated diphenyl ethers (PBDEs) and tetrabromobisphenol A (TBBPA). To determine dissolved BFRs, a novel mixed-mode solid-phase extraction procedure was developed by combining a hydrophobic sorbent (C18) with a silica-based anion exchange sorbent, so as to overcome the negative artefact induced by dissolved organic carbon. Extraction recoveries exceeded 73% for most analytes, except for BDE-183 and BDE-209 (57%). As regards suspended sediment and river bed sediment, extraction was carried out by means of ultrasonication (recoveries: 73–94%). These procedures, combined to gas chromatography coupled to negative chemical ionisation mass spectrometry (GC-NCI-MS), enabled the determination of BFRs at trace level: 3-160 pg L−1 in river water, 5–145 pg g−1 in bed sediment. These methods were applied to the determination of PBDEs and TBBPA in a suburban river (near Paris, France). PBDEs were systematically detected in the water column (ΣBDEs, 2,300–4,300 pg L−1); they partitioned between the dissolved and particulate phases and BDE-209 was the dominant congener, followed by BDE-99 and BDE-47. TBBPA was detected in the dissolved phase only (<35–68 pg L−1). All selected BFRs were ubiquitous in bed sediments and levels ranged from 3,100 to 15,100 pg g−1 and from 70 to 280 pg g−1 (dry weight), for ΣBDEs and TBBPA, respectively.  相似文献   

7.
In the present study, a novel analytical approach for the simultaneous determination of 27 brominated flame retardants (BFRs), namely polybrominated diphenyl ethers (PBDEs), isomers of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA) and several novel BFRs (NBFRs), together with 18 perfluoroalkyl substances (PFASs) in indoor dust was developed and validated. To achieve integrated isolation of analytes from the sample and their fractionation, a miniaturized method based on matrix solid phase dispersion (MSPD) was employed. Principally, after mixing the dust (<0.1 g) with the Florisil®, the mixture was applied on the top of a sorbent (Florisil®) placed in glass column and then analytes were eluted using solvents with different polarities. For the identification/quantification of target compounds largely differing in polarity, complementary techniques represented by gas and liquid chromatography coupled to tandem mass spectrometry (GC–MS/MS and LC–MS/MS) were used. The results of validation experiments, which were performed on the SRM 2585 material (for PBDEs, HBCDs and TBBPA), were in accordance with the certified/reference values. For other analytes (NBFRs and PFASs), the analysis of an artificially contaminated blank dust sample was realized. The method recoveries for all target compounds ranged from 81 to 122% with relative standard deviations lower than 21%. The quantification limits were in the range of 1–25 ng g−1 for BFRs and 0.25–1 ng g−1 for PFASs. Finally, 18 samples (6 households × 3 sampling sites) were analyzed. The high variability between concentrations of PFASs and BFRs in the dust samples from various households as well as collecting sites in a respective house was observed. The total amounts of PFASs and BFRs were in the range of 1.58–236 ng g−1 (median 10.6 ng g−1) and 39.2–2320 ng g−1 (median 325 ng g−1), respectively. It was clearly shown that dust from the indoor environment might be a significant source of human exposure to various organohalogen pollutants.  相似文献   

8.
A combined stir bar coated with poly (dimethysiloxane)-beta-cyclodextrin (PDMS-beta-CD) on single side has been prepared for the first time by sol-gel method and was coupled with ultrasonic assisted extraction (UAE) for the determination of some brominated flame-retardant compounds (BFRs) in soil and dust samples by high performance liquid chromatography (HPLC). Four different kinds of coatings including PDMS-beta-CD, PDMS, carbowax (CW)-PDMS-poly (vinyl alcohol) (PVA) and PDMS-PVA were evaluated for stir bar sorptive extraction of BFRs by orthogonal experiment design. The experimental results reveal that the PDMS-beta-CD combined stir bar exhibited the best extraction efficiency for the target analytes. The reproducibility for the preparation of PDMS-beta-CD combined stir bar ranged from 1.3% to 15.7% in one batch, and 7.2% to 15.1% among batches. Extraction time, desorption solvent, concentration of methanol and NaCl in the matrix, pH, temperature and stirring speed were optimized. The combined stir bar can avoid direct friction of the coating with the bottom of the vessel, and could be used for more than 100 times. Linearity (>0.993), repeatability (<10.5%), reproducibility (<16.5%), recovery (56-118%) and detection limits (2.9-4.2 microg L(-1)) were proper to determine the seven BFRs. The developed method was applied to the determination of BFRs in soil and dust with satisfactory results.  相似文献   

9.
Non-aqueous capillary electrophoresis (NACE) with large-volume sample stacking injection using the electroosmotic flow pump (LVSEP) has been developed for the determination of tetrabromobisphenol A (TBBPA) and other phenolic compounds in environmental matrices. Methanol has been used as run buffer solvent to reduce the electroosmotic flow (EOF). Identification and quantification of the analytes was performed by photodiode array ultraviolet detection. LVSEP-NACE improved sensitivity of the peak height by 90-300-fold. The method developed was applied to the analysis of TBBPA in river water and wastewater samples, using solid-phase extraction (SPE) as sample pretreatment process. The average recoveries of the analytes were in the range of 96-106% and 73-103% for 1 L of river water and 0.5 L of wastewater samples, respectively. When the method was based on off line SPE-LVSEP-NACE, sensitivity was improved by 3300-4500-fold and 1600-2200-fold for river water and wastewater samples, respectively.  相似文献   

10.
A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 °C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC–MS without any clean-up process. The recoveries were in the range of 93.5–104.6%, and the relative standard deviations were lower than 8.7%.  相似文献   

11.
A poly(vinylphenylboronic acid–ethylene glycol dimethacrylate) monolithic material incorporated with graphene oxide was synthesized inside a poly(ether ether ketone) tube. This tube with boronate affinity monolith was coupled with a high‐performance liquid chromatography system through a six‐port valve to construct an online solid‐phase microextraction with high‐performance liquid chromatography system. The performance of this solid‐phase microextraction with high‐performance liquid chromatography system was demonstrated by standard glycoprotein in aqueous samples, namely, horseradish peroxidase. Some parameters that affect the extraction performance were investigated, including sampling rate, pH of sample solution, and sampling volume. Under the optimized conditions, the developed method showed high extraction efficiency toward horseradish peroxidase. The addition of graphene oxide greatly increased the extraction efficiency of boronate affinity monolith for horseradish peroxidase. The limit of detection of the proposed method was as low as 0.01 μg/mL by using ultraviolet detection. The recognition specificity was also evaluated by analyzing the mixture of bovine serum albumin (nonglycoprotein) and horseradish peroxidase. The results showed that this material could selectively extract horseradish peroxidase from the mixture, indicating its good specificity toward glycoproteins. The proposed method was further applied for analyzing rat plasma samples spiked with horseradish peroxidase. Good recovery and repeatability were obtained.  相似文献   

12.
This paper describes the development of a methodology for the simultaneous determination and quantification of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA), and related compounds (bisphenol A, monobromobisphenol A, dibromobisphenol A, and tribromobisphenol A) in sludge and sediment samples. The selected method is based on an extraction with dichloromethane: methanol followed by purification via SPE C18 cartridges. Instrumental determination was carried out by liquid chromatography–quadrupole linear ion trap mass spectrometry (LC-QqLIT-MS), with quantification based on isotopic dilution method. Analyte recoveries were in the range of 39–120% and 88–126% for spiked sewage and sediment, respectively. Repeatability of replicate extractions was better than 13% relative standard deviation. Linearity was checked in the range of 0.05 and 25 injected nanograms. Limits of detection (LODs) and limits of quantification (LOQs) were in the range of 0.6 and 2.7 ng/g and 1.4 and 66 ng/g for sediment and sludge samples, respectively. The developed method was applied to sewage sludge and sediment samples collected along the Ebro River and Cinca River, one of its tributaries (northeast of Spain). TBBPA levels in sewage sludge ranged from not quantified to 1,329 ng/g dw, whereas levels in sediment samples were lower, between not detected and 15 ng/g dw. As regards HBCD, concentrations were between not detected and 375 ng/g for sludge samples and 0.8 and 1850 ng/g for sediments.  相似文献   

13.
Cetyltrimethyl ammonium bromide‐modified attapulgite was prepared and utilized as a novel sorbent in a simple solid‐phase extraction method for the determination of vitamin A in blood serum. Several factors affecting extraction efficiency were systematically optimized, including the sampling solvent and its volume, as well as the elution solvent and its volume. Under the optimal solid‐phase extraction conditions, the adsorption capacity of vitamin A was as high as 28 mg/g according to the Langmuir isotherm model. Based on the developed solid‐phase extraction method, the level of vitamin A in 200 µL blood serum sample could be accurately determined by high‐performance liquid chromatography. The recoveries of vitamin A spiked in 10% v/v methanol aqueous solutions were in the range of 86.9–92.8%, with the relative standard deviations not more than 8.1%. The method was applied to the determination of vitamin A in serum samples from 20 pregnant women. Compared with the previously reported solid‐phase extraction methods for determination of vitamin A in serum, our developed cetyltrimethyl ammonium bromide‐modified attapulgite‐based solid‐phase extraction method used lower serum volume, omitted extra steps (i.e. evaporation and re‐dissolution), and eliminated internal standard. The results were promising for it to be used in routine monitoring during pregnancy.  相似文献   

14.
A simple, environmentally friendly, and sensitive dispersive liquid–liquid microextraction based on solidification of floating organic droplet for the extraction of four acidic nonsteroidal anti‐inflammatory drugs (ketoprofen, naproxen, ibuprofen, and diclofenac) from wastewater samples subsequent by high‐performance liquid chromatography analysis was developed. The influence of extraction parameters such as pH, the effect of solution ionic strength, type of extraction solvent, disperser solvent, and extraction solvent volume were studied. High enrichment factors (283–302) were obtained through the developed method. The method provides good linearity (r > 0.999) in a concentration range of 1–100 μg/L, good intra‐ and inter‐day precision (relative standard deviation < 7%) and low limits of quantification. The relative recoveries of the selected compounds were situated over 80% both in synthetic and real water samples. The developed method has been successfully applied for the analysis of the selected compounds in wastewater samples.  相似文献   

15.
A high performance liquid chromatography-electrospray (negative) ionization-tandem mass spectrometry (HPLC-ESI(-)-MS-MS) based method has been developed for simultaneous determination of bisphenol A (BPA), tetrachlorobisphenol A (TCBPA), and tetrabromobisphenol A (TBBPA), as well as lower brominated BPA analogues in sediment and sludge samples. Samples were extracted with MTBE, target compounds were partitioned by aqueous solution of sodium hydroxide. The solution was subsequently acidified, and the enrichment and desalting were performed via solid phase extraction (SPE). After cleanup the target compounds were determined by HPLC-ESI(-)-MS-MS. The method limits of quantification (MLOQs) from sediment and sludge for BPA, monobromo-bisphenol A (mono-BBPA), dibromo-bisphenol A (di-BBPA), tribromo-bisphenol A (tri-BBPA), TBBPA and TCBPA were 0.15, 0.02, 0.02, 0.04, 0.05, and 0.03 ng/g (dry weight), respectively. Mean recovery of the analytes from spiked samples ranged from 70 to 105%, and the relative standard deviation ranged from 4.9 to 13.1%. The method was successfully applied to sediment and sludge samples analysis.  相似文献   

16.
Sensitive detection of tetrabromobisphenol A (TBBPA) and its derivatives, a group of emerging toxic contaminants, is highly necessitated in environmental investigation. Herein a novel analytical strategy based on reactive extractive electrospray ionization (EESI) tandem mass spectrometry for detection of tetrabromobisphenol A bis(2-hydroxyethyl ether) (TBBPA-BHEE), tetrabromobisphenol A bis(glycidyl ether) (TBBPA-BGE), tetrabromobisphenol A bis(allylether) (TBBPA-BAE), and tetrabromobisphenol S bis(allylether) (TBBPS-BAE) in industrial waste water samples was developed. Active silver cations (Ag+), generated by electrospraying a silver nitrate methanol solution (10 mg L−1), collides the neutral TBBPA derivatives molecules in the EESI source to form [M + Ag]+ complexes of the analytes under the ambient conditions. Upon collision-induced dissociation (CID), characteristic fragments of the [M + Ag]+ complexes were identified for confident and sensitive detection of the four TBBPA derivatives. Under the optimized experimental conditions, the instrumental limits of detection (LODs) of TBBPA-BHEE, TBBPA-BGE, TBBPA-BAE and TBBPS-BAE were 0.37, 0.050, 0.76, and 4.6 μg L−1, respectively. The linear ranges extended to 1000 μg L−1 (R2 ≥ 0.9919), and the relative standard deviations (RSDs), inter-day variation and intra-day variation were less than 7.8% (n = 9), 10.0% (n = 5), and 14.8% (n = 1 per day for 5 days) for all derivatives. TBBPA derivative manufacturing industrial waste water, river water and tap water samples were fast analyzed with the proposed method. The contents of TBBPA derivatives were various in the collected samples, with the highest 19.9 ± 0.3 μg L−1 of TBBPA-BAE in the waste water samples.  相似文献   

17.
In this study, we present a simple and easy-to-use extraction method that is based on a hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE), as an extraction technique, followed by gas chromatography-mass spectrometry (GC-MS) to determine a group of brominated flame retardants (BFRs), polybrominated diphenyl ethers (PBDEs), at trace levels in aqueous samples. The hollow-fiber membrane (HF) filled with organic solvent was immersed into the aqueous sample, spiked with the analytes at ng l(-1) level, and stirred for 60 min. The proposed method could attain enrichment factors (E(e)) up to 5200 times, after optimising parameters, such as organic solvent, stirring speed and extraction time, that affect the extraction. The HF-MMLLE-GC-MS method was successfully applied to the extraction of PBDEs from tap, river and leachate water samples with spike recoveries ranging from 85% to 110%. The method validation with reagent and leachate water samples provided good linearity, detection limits of 1.1 ng l(-1) or lower, both in reagent and leachate water, as well as satisfactory precision in terms of repeatability and reproducibility with values of % relative standard deviation (%RSD) lower than 8.6 and 16.9, respectively.  相似文献   

18.
A method to determine alpha-, beta- and gamma-hexabromocyclododecane (HBCD) and tetrabromobisphenol A (TBBPA) in water and sediments was presented using solid phase extraction (SPE) and/or solvent extraction. Recoveries from sediments were approximately 100% for all the chemicals, while recoveries of alpha-, beta- and gamma-HBCDs from water were dependent on the extraction method. In the case of dichloromethane (CH2Cl2) extraction, recoveries of alpha-, beta- and gamma-HBCD from landfill leachates were 77%, 88% and 92%, respectively. Technical difficulties in HBCD measurement are discussed in terms of the physico-chemical properties of HBCD isomers. The method was applied to landfill samples and marine sediment.  相似文献   

19.
A rapid and reliable analytical method based on pressurised solvent extraction (PSE) and GC-NCI-MS was developed for the determination of 41 different PBDEs in soil. All PBDEs, including mono- to hepta-BDEs (sum of 39 congeners), one nona-BDE and deca-BDE, were efficiently extracted from soil samples using the extraction technology of PSE. The extract was then cleaned up on a florisil column. Satisfactory separation of 41 PBDE congeners was obtained on a 15-m DB-5MS capillary column, saving the use of another 30-m column specific for the separation of mono- to hepta-BDEs. PBDEs were identified and quantified by GC-MS in negative chemical ionisation (NCI) mode, and further confirmed in semi electron impact (SEI) mode when the ion source was also NCI. The method detection limits ranged from 0.01 to 0.03?ng?g?1?dw for mono- to hepta-BDEs, 1.43?ng?g?1?dw for the nona-BDE and 0.20?ng?g?1?dw for deca-BDE. The applicability of the method was tested in soil samples collected from an e-waste recycling site at Guiyu. Twenty-one PBDEs (mono- to deca-) were detected, and eighteen congeners were quantified. The concentration range of PBDEs was 0.78–436?ng?g?1?dw. BDE-47, BDE-99, BDE-153, BDE-183, BDE-206 and BDE-209 were the dominant congeners, and BDE-209 accounted for 62% of the total PBDEs. The congener profiles of PBDEs in soil samples were similar to those in three commercial PBDE products (Penta-, Octa- and Deca-BDE), and Deca-BDE product was the most important contributor.  相似文献   

20.
A new method, which involves liquid-phase microextraction (LPME) followed by high performance liquid chromatography (HPLC) with diode array detector (DAD), was developed to determine phoxim in water sample. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, agitation speed of the sample and extraction time were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 5 μg mL−1. The limit of detection (LOD) is 10 ng mL−1, and relative standard deviation (RSD) at the 100 ng mL−1 levels is 8.4%. Lake water and tap water samples were successfully analyzed using the proposed method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号