首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
:Based on the pre-column derivatization of monosaccharides with 1-phenyl-3-methyl-5-pyrazolone,the fingerprints of polysaccharide hydrolysate monosaccharides in the extract of Mesona chinensis Benth was established using reversed-phase high performance liquid chromatography (HPLC) gradient elution/UV detection technology,which was used for the analysis of the components and content of polysaccharide hydrolyzed monosaccharides in the aqueous extract of Mesona chinensis Benth,and eight monosaccharide components including ribose,rhamnose,glucuronic acid,galacturonic acid,glucose,galactose,xylose and arabinose were identified. Similarity analysis,cluster analysis,principal component analysis of the HPLC fingerprints of monosaccharide components were carried out,and the changes in the contents of galactose, galacturonic acid and glucose monosaccharide components in various samples were clarified. Regional differences lead to differences in cluster analysis,and there are certain differences in the content and distribution of monosaccharide components produced by polysaccharide hydrolysis in Mesona chinensis Benth collected from different origins. The method can provide a potential technology for characterizing monosaccharide components of the polysaccharide in aqueous extract of Mesona chinensis Benth. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

2.
Wang  Xiaowen  Liu  Jia  Zheng  Qiuying  Li  Puchao  Tang  Hai  Zhou  Wei  Liu  Quanli 《分析试验室》2022,(9):1089-1095
A method was developed for the simultaneous determination of R-pinacol-1-amino-3-methylbutylborate hydrochloride and isopentylamine hydrochloride by pre-column derivatization high performance liquid chromatography HPLC with dichloromethane as solventtriethylamine as acid binding agent and benzoyl chloride as derivative reagent. R-pinacol-1-amino-3-methylbutylborate hydrochloride and isopentylamine hydrochloride reacted with derivatization reagent in an ice bath for 10 min. The derivatives were qualitatively determined by HPLC-mass spectrometryHPLC-MS. HPLC was performed on an AgelaVenusil MP C18 2column using methanol-water 7030V/Vas mobile phase. The flow rate was 1.0 mL/minthe detection wavelength was 236 nm and the column temperature was 35 . The UV absorption produced after derivatizationwhich could be detected by HPLC with good specificity. Isopentylamine hydrochloride derivative showed an excellent linearity in the range of 0.075-30 μµg/mLwith the limit of quantification and the limit of detectionLODof 0.075 and 0.030 μµg/mLrespectively. And the S/N of the LOQ and the LOD were 44.6 and 7.8respectively. The average recoveries were 97.7%-104.0% with the RSD of 2.9%. The method is suitable for the determination of isoamylamine hydrochloride and has significant reference value for the determination of other amine salt without UV absorption. © 2022, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

3.
Diethylstilbestrol (DES) is a synthetic estrogen that has ever been used worldwide. Polyclonal antibodies (PAbs) were used in immunoassay for detection of DES residues in environmental and agricultural samples in previous paper. In this paper, an indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed based on monoclonal antibody (MAb) for the determination of diethylstilbestrol. Mono-o-carboxypropyldiethylstilbestrol (DES-CP) and mono-o-carboxymethyldiethylstilbestrol (DES-CME) were synthesized to be haptens. DES-CP was coupled to bovine serum albumin (BSA) to be an immunogen in BALB/c female mouse for MAb production. The MAb was characterized for specificity and affinity to DES in icELISA. Under the optimum condition, the icELISA showed an ICs0 of 9.8 ng/mL, the limit of detection (IC20) of 2.3 ng/mL and a working range of 2-42 ng/mL. Hexestrol and dienestrol exhibited cross-reactivity values were 44% and 27%, respectively. Cross-reactivity of natural estrogen 17β-estradiol was less than 0.1%. The influences of some factors such as salt concentration, pH and organic solvent concentration on the assay were evaluated. The concentrations of DES in the fortified water samples determined by the assay were correlated well with the fortification levels. The results were conf'm'ned with analysis by HPLC.  相似文献   

4.
A column-switching anion-exchange chromatography method was described for the separation and determination of petroleum monosulfonates (PMS) and petroleum disulfonates (PDS) in crude oil that was simply diluted with the dichloromethane/methanol (60/40). The high performance liquid chromatography (HPLC) system consisted of a clean-up column and an analytical column, which were connected with two six-port switching valves. Detection of petroleum sulfonates was available and repeatable. This method has been successfully applied to determine PMS and PDS in crude oil samples from Shengli oil field.  相似文献   

5.
A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples  相似文献   

6.
An indirect competitive enzyme-linked immunosorbent assay (icELISA) based on polyclonal antibody for the estrogen diethylstilbestrol (DES) was developed. With this aim, two different haptens mono-O-3-carboxypropyldiethylstilbestrol (DES-CP) and mono-O-carboxymethyldiethylstilbestrol (DES-CM) with carboxylic group that preserve the molecular structure character of diethylstilbestrol were synthesized. The haptens were conjugated with the carder proteins bovine serum albumin (BSA) by mixed-anhydride method for immunogen and conjugated with ovalbumin (OVA) by active ester method for coating antigen. Polyclonal antibodies for diethylstilbestrol were raised by immunizing mice with immune antigen DES-CP-BSA. Under optimized system, the lowest limit of detection (LLD) of diethylstilbestrol was 0.01 ng/mL, and IC50= 1.02 ng/mL. Its analogs were tested and no obvious cross-reactivity was found to anti-diethylstilbestrol antibody. DES-fortified water samples were determined by simple dilution to diminish the matrix effect. The comparison between the amount of DES estimated by ELISA and the amount added indicates good agreement for all water samples tested, with mean recovery values ranging from 86% to 120.2%.  相似文献   

7.
Potassium dehydroandrographolide succinate (DAS-K) has antibacterial and antiviral effects. It has been used widely for the treatment of virus pneumonia, malaria and respiratory infections. In this work, a novel flow-injection chemiluminescence (CL) method for the determination of DAS-K was proposed. The method is based on the reaction between DAS-K and hexacyanoferrate(III) in alkaline solution to give weak CL signal, which is enhanced by rhodamine B. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. Under the optimum conditions, the concentration of DAS-K is proportional to the CL intensity in the range of 0.1-80 μmol·L^-1 with a detection limit of 0.05 μmol·L^-1. The interaction of the DAS-K with bovine serum albumin by on-line ultrafiltration and flow-injection chemiluminescence was studied. The concentrations of unbound DAS-K from ultra filter tube were determined by the flow-injection CL method. The binding parameters were estimated by the Scatchard plot and Klotz plot. The proposed system proved that FIA-CL coupled with on-line ultrafiltration sampling was a fast and simple technique for the study of drug-protein interaction.  相似文献   

8.
A flow-injection chemiluminescence (CL) method for the determination of melatonin based on the CL reaction of melatonin with hydrogen peroxide and sodium hypochlorite (NaOCl) in a basic alkaline solution was developed. The possible CL mechanism has been discussed, and a proposal for the reaction pathway was given that singlet oxygen was clarified to be produced in this reaction system and was responsible for the CL emission. Under the optimized conditions, the linear concentration range of application was 1.0×10^-7-2.5 × 10^-4 moloL-I with a de- tection limit of 5.0 ×10^-8 moloL-1 (S/N= 3). The relative standard deviation for eight repeated measurements of 1.0×10^-6 mol·L^-1 melatonin was 2.8%. The interferences of several important biological substances, some indole compound, cations and anions were studied. No interference was found for the anions, glucose, starch, most of cations and low concentration (less than 3.0 × 10^-6 mol·L^-1) of some biological substances and indole compound. The method was applied to the determination of melatonin in rat pineal gland and drug with satisfactory results. The sample throughput was 90 injections per hour.  相似文献   

9.
In this paper, a novel magnetic solid-phase extraction method using three-dimensional graphene-based magnetic nanocomposite as adsorbent for the preconcentration of several chlorophenols from water samples prior to high-performance liquid chromatography analysis was developed. Various experimental parameters were investigated. Under the optimum conditions, the enrichment factors of the method were in the range of 186–312, and the limit of detection(S/N = 3) was 0.10 ng/mL. The recoveries of the method were in the range between 85.1% and 101.2%. The developed method has been successfully applied to the determination of chlorophenols in environmental water samples.  相似文献   

10.
In this work, solid-phase microextraction coupled with gas chromatography–mass spectrometry was developed to determine trace levels of nitrobenzene compounds in water and soil samples. Graphene was chosen as the extraction material and its composite was coated on a stainless steel wire through sol–gel technique for the solid phase microextraction. The key parameters influencing the extraction efficiency were optimized. Under the optimal conditions, the linearity for the compounds was observed in the range of 0.02–15.0 mg/L for water samples, and 0.2–60.0 mg/kg for soil samples, with the correlation coefficients(r) of 0.9966–0.9987. The limits of detection of the method were 0.0025–0.005 mg/L for water samples, and 0.02–0.04 mg/kg for soil samples. The recoveries for the spiked samples were in the range of 72.0%–113.2%, and the precision, expressed as the relative standard deviations, was less than 12.1%.  相似文献   

11.
Altered levels of thiols in biological fluids are considered to be an important indicator for several diseases. In this article, 1,3,5,7‐tetramethyl‐8‐bromomethyl‐difluoroboradiaza‐s‐indacene is proposed as a fluorescent derivatization reagent for the determination of thiols including glutathione, cysteine, N‐acetylcysteine, and homocysteine by HPLC. Under the optimized derivatization and separation conditions, a baseline separation of all the four derivatives has been achieved using isocratic elution on an RP C8 column within 26 min. With fluorescence detection at 505 and 525 nm for the excitation and emission, respectively, the LODs (S/N = 3) are from 0.2 nM (glutathione) to 0.8 nM (cysteine). The feasibility of this method in real samples has been evaluated by the determination of thiols in human plasma from the healthy persons and hypertensive patients with recoveries of 92–105.3%.  相似文献   

12.
Enantioseparation of α,α‐diphenyl‐2‐pyrrolidinemethanol (D2PM) and methylphenidate (MPH; Ritalin®) using (R)‐(?)‐4‐(N,N‐dimethylaminosulfonyl)‐7‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐2,1,3‐benzoxadiazole as the chiral derivatization reagent has been achieved for the first time, and a simple, reliable detection method using HPLC with fluorescence detection has been developed. D2PM and MPH have been derivatized with (R)‐(?)‐4‐(N,N‐dimethylaminosulfonyl)‐7‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐2,1,3‐benzoxadiazole at 55°C for 15 min. The derivatives of D2PM and MPH have been separated, completely and rapidly, using a reversed‐phase system within 16 min (resolution factor (Rs)=1.60 and 2.53, respectively). The detection limits of (R)‐ and (S)‐D2PM were found to be 6.8 and 13 ng/mL, respectively, and those of D ‐ and L ‐threo‐MPH were 61 and 66 ng/mL, respectively (S/N=3). The proposed method was successfully applied to the analysis of rat plasma, where the rats were separately dosed with D2PM and MPH (Ritalin).  相似文献   

13.
In this study, we successfully studied water‐soluble extract from Radix isatidis. Optimized conditions of MAE were listed, the sample can be extracted completely in 10 minutes under microwave power of 400W and solid/liquid ratio of 1:80. Active compounds in water‐soluble extract from R. isatidis were identified with HPLC‐DAD/ESI‐MS, these compounds followed by cytidine, uridine, guanosine, (R,S)‐goitrin and adenosine. RODWs–HPLC as a new sensitive chromatography were also first proposed and investigated, we favoringly used this method for simultaneous determination of these active constitutents in water‐soluble R. isatidis extract. Chromatographic separation was performed on a Diamonsil C18 column (5 μm, 150 mm × 4.6 mm) with a mobile phase gradient consisting of methanol and water at a flow‐rate of 1.0 mL/min, detection wavelengths 240, 250, 260 and 270 nm, the retention times of the tested five compounds were about 4.2, 5.8, 11.1, 14.2 and 20.8 min respectively, the limits of detection were 15, 12, 20, 5.8 and 24 ng/mL for cytidine, uridine, guanosine, (R,S)‐goitrin and adenosine respectively, their linear ranges were between 0.045 and 350 μg/mL with correlation coefficient (R) of 0.9998‐0.9999. The relative standard deviations (RSDs) of intra‐day and inter‐day assays were 0.30‐2.36% and 0.86‐2.54% respectively. Extraction recoveries were 94.25‐106.21%. This novel analytical method was shown to be simple, low‐cost, sensitive and reliable for multiple components in complex or undeveloped materials via MAE, ESI‐MS and RODWs‐HPLC.  相似文献   

14.
Precolumn derivatization of six short‐chain aliphatic amines by a near‐infrared dye, 1‐(ε‐succinimydyl‐hexanoate)‐1′‐methyl‐3,3,3′,3′‐tetramethyl‐indocarbocyanine‐5,5′‐ disulfonate potassium (MeCy5‐OSu), followed by MEKC–CE–LIF detection has been developed as a method for the determination of aliphatic amines in environmental water and food. Optimum derivatization was operated nicely in pH 9.0 borate buffer at 20°C for 30 min. Well separated peaks were observed with a pH 9.5 BGE containing 10 mmol L?1 phosphoric acid, 20 mmol L?1 SDS, and 7% methanol buffered with 1.0 mol L?1 NaOH. The separation procedure was rapidly achieved within 11 min and the matrix interferences could be effectively eliminated. A linear calibration graph was obtained for 5–200 nmol L?1 analytes with a correlation coefficient in the range 0.9933–0.9995 for amines. This method was successfully utilized to determine aliphatic amines in lake, sewage water, and red wine with recoveries ranging from 96.4 to 105% and the RSDs ranging from 0.9 to 2.9%. Near‐infrared, LIF‐detector‐compatible MeCy5‐OSu was proved suitable for the accurate, sensitive, and rapid separation and determination of aliphatic amines in water and food samples.  相似文献   

15.
Enantioselective biodistribution studies of 1‐[4‐(2‐methoxyethyl)phenoxy]‐3‐[2‐(2‐methoxyphenoxy)ethylamino]‐2‐propanol hydrochloride (TJ0711), a novel antihypertensive agent, require the accurate and precise quantification of each TJ0711 enantiomer in biological fluids and tissues. Here we report a simple and sensitive liquid chromatography with tandem mass spectrometry method for simultaneous determination of (R )‐TJ0711 and (S )‐TJ0711 in rat plasma and tissue samples using protein precipitation. The influence of column type, temperature, mobile phase composition, and flow rate on the retention and enantioselectivity was evaluated. The separation of the TJ0711 enantiomers was ultimately achieved on a SUMICHIRAL OA‐2500 column in 15 min using isocratic elution with ethanol/hexane (40:60) at a flow rate of 0.8 mL/min. Good linearities of spiked analyte concentration from 5 to 2000 ng/mL were achieved and the correlation coefficients (R ) were greater than 0.99. The intra‐ and inter‐day accuracy and precision for both analytes were <15% at all concentration levels, and the extraction recoveries were consistent among the five quality control concentrations. This assay was successfully applied to quantify plasma and tissue concentrations of TJ0711 enantiomers in a preclinical study.  相似文献   

16.
A new pre‐column derivative high‐performance liquid chromatography (HPLC) method for determination of d ‐glucose with 3‐O‐methyl‐d ‐glucose (3‐OMG) as the internal standard was developed and validated in order to study the gluconeogenesis in HepG2 cells. Samples were derivatized with 1‐phenyl‐3‐methy‐5‐pyrazolone at 70°C for 50 min. Glucose and 3‐OMG were extracted by liquid–liquid extraction and separated on a YMC‐Triart C18 column, with a gradient mobile phase composed of acetonitrile and 20 mm ammonium acetate solution containing 0.09% tri‐ethylamine at a flow rate of 1.0 mL/min. The eluate were detected using a UV detector at 250 nm. The assay was linear over the range 0.39–25 μm (R2 = 0.9997, n = 5) and the lower limit of quantitation was 0.39 μm (0.070 mg/mL). Intra‐ and inter‐day precision and accuracy were <15% and within ±3%, respectively. After validation, the HPLC method was applied to investigate the gluconeogenesis in Dulbecco's modified Eagle medium (DMEM) cultured HepG2 cells. Glucose concentration was determined to be about 1–2.5 μm in this gluconeogenesis assay. In conclusion, this method has been shown to determine small amounts of glucose in DMEM successfully, with lower limit of quantitation and better sensitivity when compared with common commercial glucose assay kits. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
An ultrasound assisted emulsification microextraction (USAEME) is successfully used for extraction and determination of trace amount of iron in water and tea samples, followed by flame atomic absorption spectroscopy (FAAS). In this approach, a new synthetic ligand dimetyl (E)‐2‐[(Z)‐1‐acetyl)‐2‐hydroxy‐1‐propenyl]‐2‐butenedioate (DAHPB) is used as chelating agent and chloroform is selected as an extraction solvent. The factors influencing the complex formation and extraction by USAEME method are optimized. These factors are extraction solvent type as well as extraction volume, time, temperature, pH, and the amount of chelating agent. Under optimum conditions, an enrichment factor of 202.9 is obtained from only 7.1 mL of aqueous phase. The calibration graph using the preconcentration system for iron is linear between 40.0 and 800.0 μg L?1 with a detection limit of 7.4 μg L?1. The relative standard deviation (R.S.D) for ten replicate measurements of 500.0 μg L?1 of iron is 2.5%.  相似文献   

18.
The hydrolysis reactions of N-(O,O'diisopropyl)phosphoryl-L-α-alanine (DIPP-L-α-Ala), N-(O,O'diisopropyl)- phosphoryl-D-α-alanine (DIPP-D-α-Ala), N-(O,O'-diisopropyl)phosphoryl-β-alanine (DIPP-β-Ala) and N-(O,O'-diisopropyl)phosphoryl-γ-amino butyric acid (DIPP-γ-Aba), were studied by HPLC and their hydrolysis reaction kinetic equations were obtained. Under acid conditions, the reaction rate of DIPP-L-α-Ala was close to that of DIPP-D-α-Ala and the same rule was true between DIPP-β-Ala and DIPP-γ-Aba. Meantime, the reaction rate of DIPP-L/D-α-Ala was as 10 times as that of DIPP-β-Ala or DIPP-γ-Aba. Under basic conditions, the hydrolysis reactions of DIPP-β-Ala and DIPP-γ-Aba almost did not take place and the reaction rate of DIPP-L/D-α-Ala was about 1/10 of that under acid conditions. Moreover, theoretical calculation further illuminated the differences of the hydrolysis rate from the view of energy. The results would provide some helpful clues to why nature chose a-amino acids but not other kinds of analogs as protein backbones.  相似文献   

19.
4-Methoxyphenyl glycoside of β-D-Galp-(1→6)-[α-L-Araf-(1→3)-]β-D-Galp-(1→6)-β-D-Galp-(1→6)-{β-D-Galp-(1→6)-[α-L-Araf-(1→3)-]β-D-Galp-(1→6)-β-D-Galp-(1→6)-}2β-D-Galp-(1→6)-[α-L-Araf-(1→)3)-]β-D-Galp-(1→)6)-β-D-Galp was synthesized with 2,3,4,6-tetra-O-benzoyl-α-D-galactopyranosyl trichloroacetimidate (1), 6-O-acetyl-2,3,4-tri-O-benzoyl-α-D-galactopyranosyl trichloroacetimidate (11), 4-methoxyphenyl 3-O-allyl-2,4-tri-O-benzoyl-β-D-galactopyranoside (2),isopropyl 3-O-allyl-2,4-tri-O-benzoyl--thio-β-D-galactopyranoside (12),4-methoxyphenyl 2,3,4-tri-O-benzoyl-β-D-galactopyranoside (5), and 2,3,5-tri-O-benzoyl-α-L-arabinofuranosyl trichloroacetimidate (8) as the key synthons.  相似文献   

20.
In this study, a sensitive HPLC‐UV assay was developed and validated for the determination of LASSBio‐1736 in rat plasma with sodium diclofenac as internal standard (IS). Liquid–liquid extraction using acetonitrile was employed to extract LASSBio‐1736 and IS from 100 μL of plasma previously basified with NaOH 0.1 M. Chromatographic separation was carried on Waters Spherisorb®S5 ODS2 C18 column (150 × 4.6 mm, 5 μm) using an isocratic mobile phase composed by water with triethylamine 0.3% (pH 4), methanol and acetonitrile grade (45:15:40, v/v/v) at a flow rate of 1 mL/min. Both LASSBio‐1736 and IS were eluted at 4.2 and 5 min, respectively, with a total run time of 8 min only. The lower limit of quantification was 0.2 μg/mL and linearity between 0.2 and 4 μg/mL was obtained, with an R2 > 0.99. The accuracy of the method was >90.5%. The relative standard deviations intra and interday were <6.19 and <7.83%, respectively. The method showed the sensitivity, linearity, precision, accuracy and selectivity required to quantify LASSBio‐1736 in preclinical pharmacokinetic studies according to the criteria established by the US Food and Drug Administration and European Medicines Agency. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号