1.
Metformin is a well‐known oral antihyperglycemic drug used in treatment of type II diabetes. Analysis of metformin in biological fluids is a challenge owing to its high polarity and small molecular size, which lead to poor retention of metformin on reversed‐phase liquid chromatographic columns. A high‐throughput method was developed and validated for the determination of metformin in rat plasma in support of preclinical toxicology studies, using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC‐MS/MS) and Tecan automated sample preparation. Extracted samples were directly injected onto the unbounded silica column with an aqueous–organic mobile phase. This HILIC‐MS/MS method was validated for accuracy, precision, sensitivity, stability, matrix effect, recovery and calibration range. Acceptable intra‐run and inter‐run assay precision (coefficient of variation ≤ 3.9%) and accuracy (99.0–101.8%) were achieved over a linear range of 50–50,000 ng/mL. Metformin is stable in rat plasma for at least 6 h at room temperature, 147 days at ?70°C and through three freeze (?70°C) and thaw cycles. Metformin is also stable in rat whole blood for at least 2 h at room temperature and in an ice–water bath. The validated method was successfully used in support of several preclinical studies where metformin is dosed together with an investigational drug substance. The ruggedness of the validated method was demonstrated by the incurred sample reproducibility test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
Recently, a new ion source, Direct Analysis in Real Time (DART), has been introduced which allows direct biological sample introduction into a mass spectrometry (MS) system. The elimination of conventionally required sample preparation and separation by high-performance liquid chromatography (HPLC) prior to MS analysis represents a remarkable opportunity to reduce assay turn-around time, environmental impact and capital/manpower investment. This new technology initially was used in various qualitative applications to directly detect chemicals on solid surfaces, in liquids and gases. In this study, a DART source operating under ambient pressure with ground potential was installed onto a Sciex 4000 tandem mass spectrometer and employed in the sample analysis of plasma based on direct introduction into the DART-MS/MS system. Reasonable precision and accuracy (%CV and %Error, both <10%) were achieved of a significant number of compounds tested in biological fluids. In addition, the limit of detection for 80% of the tested compounds reached 5 ng/mL or lower which is sufficient for pharmaceutical drug discovery support. Finally, experimental conditions that significantly impacted assay performance were investigated with respect to optimization and limitation. Because of its simplicity, fast data acquisition (3-5 s) and low cost, DART has the potential to significantly impact quantitative pharmaceutical analysis in biological matrices.  相似文献   

3.
A major challenge in selecting an appropriate stationary phase for diastereomeric separation is that it is difficult to predict which of the commercially available stationary phases could achieve the required liquid chromatographic (LC) separation. This work describes the selection and evaluation of a porous graphitic carbon (PGC) column coupled with tandem mass spectrometry (MS/MS) for the simultaneous quantitation of an experimental drug candidate (I), its two diastereomeric metabolites (II and III), and its demethylated metabolite (IV) in rat plasma. In addition, we investigated the PGC column for the separation of another drug candidate (VI), its two diastereomeric metabolites (VII and VIII) and its ketone metabolite (IX). The PGC column showed excellent chromatographic resolution for the two diastereomers II and III, as well as for VII and VIII. In contrast, the required resolution for the diastereomers II and III could not be achieved using silica-bonded C(18), C(30), phenyl, perfluorinated, polar embedded and polar end-capped phases. The PGC column showed ruggedness with excellent reproducibility of retention times, peak symmetry and response over a period of more than 400 injections of a plasma acetonitrile-precipitation extract. Excellent accuracy and precision were achieved, with accuracy of 94-108% and intra- and inter-run precision within 9%. This work indicates that PGC is a valuable addition to the repertoire of LC columns used for quantitative LC/MS/MS bioanalysis, especially where the separation and quantitation of diastereomeric analytes is involved.  相似文献   

4.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

5.
Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.  相似文献   

6.
[6]-Gingerol is a structural analog of capsaicin, an agonist of the transient receptor potential channel vanilloid 1, which is known to have therapeutic properties for the treatment of pain and inflammation. A selective and sensitive quantitative method for the determination of [6]-gingerol by HPLC-ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray tandem mass spectrometry. The chromatographic separation was achieved using a Thermo 100 × 2.1 mm C(8) column combined with an isocratic mobile phase composed of acetonitrile, water and formic acid (80:20:0.1) at a flow rate of 250 μL/min. The mass spectrometer was operating in SRM mode and an analytical range set at 20-5000 ng/mL was used to construct a calibration curve in rat plasma. The interbatch precision (%CV) and accuracy (%NOM) observed were 2.9-10.8% and 98.1-102.1% in rat plasma. Similarly, precision and accuracy in rat liver microsomal suspension were also evaluated at nominal concentrations of 1, 25 and 100 μm; the precision (%CV) was <3.4% and the accuracy (%NOM) observed ranged from 89.7 to 109.4%. An in vitro metabolic stability study using rat liver microsomes was performed to determine intrinsic clearance of [6]-gingerol. The results show slow degradation with a T(1/2) of 163 min and relatively low intrinsic clearance suggesting that phase I metabolism may not be a major contributor of the drug clearance. Further analyses were performed to characterize in vitro and in vivo metabolites. Three main phase I metabolites and four phase II metabolites were identified by HPLC-MS/MS and HPLC-MSD TOF. However, the results suggest that glucuronidation of hydroxylated [6]-gingerol is the primary metabolite excreted in rat urine.  相似文献   

7.
For the first time, a systematic overview deals with the advantages and disadvantages of several stationary phases (polar and non‐polar) and gas chromatographic detectors (flame ionization detector, nitrogen–phosphorus detector and MS) for the determination of 27 amines (aliphatic and aromatic amines and N‐nitrosamines) in water samples. To increase sensitivity (250 mL of sample was eluted with 150 μL of solvent) and matrix elimination, an automatic SPE system was employed prior to GC determination. The best results in terms of resolution and retention times were achieved using a column coated with 5% phenyl‐dimethylpolysiloxane (DB‐5). Capacity factor (k) values for the 27 amines increased with the rise in the polarity of the stationary phase, ranging from 3.0–27.7 and 2.2–14.4 for polar (polyethylene glycol) and non‐polar (DB‐5) columns, respectively. The detection limits of the method were 0.9–9 μg/L for flame ionization detector, 8–95 ng/L for nitrogen–phosphorus detector and 0.2–6.3 ng/L for MS. The precision was similar for the three detectors (RSD, 3.7–6.0%). The GC‐MS method was applied with a high degree of accuracy and precision to determine amines in real samples including tap, river, pond, well, swimming pool and wastewaters.  相似文献   

8.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

9.
The only relevant source for human exposure to dinitropyrenes is diesel engine emissions. Due to this specificity, dinitropyrenes may be used as biomarkers for monitoring human exposure to diesel engine emissions. Only few analytical methods have been described for the quantitation of dinitropyrenes and their metabolites, aminonitropyrenes, and diaminopyrenes. Therefore, for dinitropyrenes, aminonitropyrenes, and diaminopyrenes were selected as model compounds for the development of a sensitive HPLC-MS/MS method (high performance liquid chromatography coupled to triple quadrupole mass spectrometry) was to quantify polyaromatic amines and nitroarenes in biological matrices was developed optimal methods by comparing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI) sources. Dinitropyrene was not effectively ionized and diaminopyrene yielded mainly [M(.)](+) ions by electrospray ionization. With APCI and APPI, precursor ions of diaminopyrene and aminonitropyrene were [M + H](+) and [M(.)](-) for dinitropyrene. Precursor ions with [M - 30(.)](-) for dinitropyrene and [M - 30 + H](+) for aminonitropyrene were observed. Reversed and normal phase HPLC-MS/MS with ESI, APCI and APPI were optimized separately with respect to unequivocal analyte identification and sensitivity. Normal phase HPLC coupled to APPI-MS/MS gave the highest precision and sensitivity for aminonitropyrene (6%/0.2 pg on column) and dinitropyrene (9%/0.5 pg on column). The limit of detection in spiked rat plasma was 5 pg/100 microL for aminonitropyrene (accuracy 82%) and 10 pg/100 microL for dinitropyrene (accuracy 105%). In plasma of rats treated with dinitropyrene by oral administration, no detectable levels of dinitropyrene but higher aminonitropyrene levels compared with intratracheal instillation were observed. These findings clearly demonstrate that dinitropyrene was absorbed after oral and intratracheal application and that a reduction of nitro groups occurs to a high extent in the reductive environment of the intestine. To our knowledge, this is the first time that aminonitropyrene was observed in plasma after intratracheal or oral administration directly demonstrating the reductive metabolism of dinitropyrene in vivo.  相似文献   

10.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

11.
A very highly sensitive and highly selective liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed to evaluate and quantify a new drug candidate in different biological matrices. Following a simple plasma protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C18 column interfaced with a new generation of triple-quadrupole mass spectrometer. The recently introduced triple-quadrupole mass spectrometer, the TSQ Quantum Ultra, with enhanced mass-resolution capability, demonstrated improved sensitivity (0.05 ng/mL), coupled with suitable accuracy and precision, over a broad linear dynamic range (0.05-1000 ng/mL). A comparison of the assay performance data (dynamic range, calibration curve equation, precision and accuracy) of the enhanced resolution method against a unit resolution method under optimized conditions showed the performance improvement of the enhanced mass resolution method for bioanalytical high-throughput applications. The enhanced mass resolution method herein described was successfully applied to the evaluation of the pharmacokinetic profile of a new drug candidate in rat, rabbit and dog plasma samples.  相似文献   

12.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
An automated chiral chromatography/tandem mass spectrometry bioanalytical method for the determination of albuterol in dog plasma was developed. The method employed on-line sample extraction using turbulent flow chromatography coupled to a Chirobiotic T column for chiral separation using a polar organic mobile phase consisting of methanol, 0.02% formic acid, and 0.1% ammonium formate. The analytes were detected by a tandem mass spectrometer operated in positive ion mode. The (S)- and (R)-isomers were resolved chromatographically with retention times of 5.1 and 5.6 min, respectively. The analytical run time was 8 min. The enantiomers did not interconvert either in mobile phase or in dog plasma at room temperature over the course of at least 2 h. The assay has a linear dynamic range from 2.5-2500 nM for both enantiomers. The lower limit of quantitation (LLOQ) was 2.5 nM for both enantiomers using 50 microL of plasma. The accuracy and precision of intraday validation were determined at five concentration levels of six replicates. The accuracy of the method for the (R)-isomer ranged from 94-103% of nominal concentrations, and the precision (%CV) ranged from 3.6-12%. The accuracy of the method for the (S)-isomer ranged from 94.5-108% of nominal concentrations, and the precision ranged from 3.2-9.3%. Interday accuracy and precision were evaluated for three days at five concentrations for one replicate. The accuracy of the method for the (R)-isomer ranged from 98-110% of nominal concentrations, and the precision ranged from 1.5-10.6%. The accuracy of the method for the (S)-isomer ranged from 96-104% of nominal concentrations, and the precision ranged from 1.5-8.7%. The combination of turbulent flow on-line sample extraction with polar organic mode chiral chromatography provided a specific, rugged, and high-throughput method for the chiral analysis of albuterol in biological fluids.  相似文献   

14.
A method using zirconia-based column high-performance liquid chromatography (HPLC) interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer (MS/MS) was developed for the quantitative determination of new chemical entities in rat plasma in support of pharmacokinetics studies. The ionization suppression resulting from endogenous components of the biological matrices on the quantitative zirconia-based column HPLC/APPI-MS/MS method was investigated using the post-column infusion technique. The analytical results for 'rapid rat pharmacokinetics' for 12 drug discovery compounds, obtained by both silica-based phase (S-phase) and zirconia-based phase (Z-phase) chromatographic separation, are in good agreement in terms of accuracy. The application of a Z-phase column for high-temperature fast HPLC/MS/MS methods was explored to reduce the analysis time from 3 min to 30 s for column temperatures of 25-110 degrees C, respectively. The chromatographic retention times and peak responses of all analytes were found to be reproducible under high-temperature conditions following 100 continuous injections, with %CV less than 0.4 and 5, respectively.  相似文献   

15.
1 Introduction Gaschromatography/massspectrometry (GC/MS)andliquidchromatography/massspectrometry (LC/MS) ,representativesofthehyphenatedtechniques ,aresomeofthemostreliableanalyticalmethods ,whicharethesynergisticcombinationoftwopowerfulanalyticaltechniques;…  相似文献   

16.
LC-electrospray ionization (ESI) MS conditions were optimized for the individual chiral separation of 19 compounds of pharmaceutical interest using the macrocyclic glycopeptide-based chiral stationary phases in both polar organic and reversed-phase modes (RPM). The influence of mobile phase composition and MS additive type on sensitivity was investigated for all classes of compounds tested. Compounds with amine or amide groups were efficiently separated, ionized, and detected with the addition of 0.1% (w/w) ammonium trifluoroacetate to the solvent system in either the reversed-phase or polar organic mode (POM). Macrocyclic glycopeptide coupled column technology was initially used to screen all chiral compounds analyzed. Baseline resolution of enantiomers was then achieved with relatively short retention times and high efficiencies on Chirobiotic T, Chirobiotic V or Chirobiotic R narrow bore chiral stationary phases. The polar organic mode offered better limits of detection (as low as 100 pg/ml) and sensitivity over reversed-phase methods. An optimum flow-rate range of 200-400 microl/min was necessary for sensitive chiral LC-ESI-MS analysis.  相似文献   

17.
The demand for high sensitivity bioanalytical methods has dramatically increased in the drug discovery stage; in addition, there has been a growing trend of reducing the sample volume that is required for these assays. A sensitive high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedure has been developed and tested to meet these needs. The assay requires only a low plasma sample volume (10 microL) and employs a protein precipitation procedure using a 1:6 plasma/acetonitrile ratio. The supernatant is injected directly into the LC/MS/MS system using the selected reaction monitoring (SRM) procedure for detection. A generic HPLC gradient based on a methanol/water mobile phase with a flow rate set to 0.8 mL/min was used. The test method showed very good linearity between 0.1-1000 ng/mL (R2 = 0.9737), precision (%RSD = 6-9), accuracy (%RE = -2) and reproducibility (%RSD = 11). A drug discovery IV/PO study was assayed using both the new low volume method and our standard volume (50 microL) method. The correlation of the two sets of data from the two methods was excellent (R2 = 0.9287). This new assay procedure has been successfully used in our laboratory for over 100 different rat or mouse discovery PK studies.  相似文献   

18.
We applied a new technique for quantitative linear range shift using in‐source collision‐induced dissociation (CID) to complex biological fluids to demonstrate its utility. The technique was used in a simultaneous quantitative determination method of 5‐fluorouracil (5‐FU), an anticancer drug for various solid tumors, and its metabolites in human plasma by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC/ESI‐MS/MS). To control adverse effects after administration of 5‐FU, it is important to monitor the plasma concentration of 5‐FU and its metabolites; however, no simultaneous determination method has yet been reported because of vastly different physical and chemical properties of compounds. We developed a new analytical method for simultaneously determining 5‐FU and its metabolites in human plasma by LC/ESI‐MS/MS coupled with the technique for quantitative linear range shift using in‐source CID. Hydrophilic interaction liquid chromatography using a stationary phase with zwitterionic functional groups, phosphorylcholine, was suitable for separation of 5‐FU from its nucleoside and interfering endogenous materials. The addition of glycerin into acetonitrile‐rich eluent after LC separation improved the ESI‐MS response of high polar analytes. Based on the validation results, linear range shifts by in‐source CID is the reliable technique even with complex biological samples such as plasma. Copyright © 2016 John Wiley & Sons Ltd.  相似文献   

19.
A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate (APDS), followed by reversed‐phase high‐performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI‐MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra‐ and inter‐day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra‐day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter‐day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra‐day and inter‐day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
 Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, some compounds do not show enough sensitivity in LC/MS and soft ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), sometimes do not give satisfactory structural information This report presents an overview  相似文献   