首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel, simple and sensitive adsorptive stripping voltammetry method was developed for simultaneous determination of Cd and Zn using N‐Nitrozo‐N‐phenylhydroxylamine (Cupferron) as a selective complexing agent. Cadmium and zinc metals gave peaks that were distinctly separated by 450–1200 mV, allowing their determination over a wide range of concentrations. The influence of pH and the nature of supporting electrolytes, concentration of ligand, preconcentration time and applied potential were investigated. The detection limits were 0.058 ng/mL for Zn and 0.092 ng/mL for Cd, and the RSD at a concentration level of 50 ppb, were 1.8–2.1 % for both zinc and cadmium, respectively. The method was applied to the determination of cadmium and zinc in blood, drug, food and water samples with the satisfactory results.  相似文献   

2.
A selective and sensitive method for the determination of cadmium and zinc is presented. The method is based on the adsorptive accumulation of the complexes of Cd(II) and Zn(II) ions with 4-amiono-5-methyl-2.4-dihydro-3H-1,2,4-triazol-3-tion (MMTT) onto hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed species using a voltammetric scan using differential pulse modulation. The ligand concentration, pH, potential and time of accumulation, scan rate, and pulse height were optimized. Under the optimized conditions, a linear calibration curve was obtained for the concentration of Cd(II) and Zn(II) in the range of 5–450 and 5–850 ng/mL, respectively, with a detection limit of 1.7 ng/mL Cd(II) and 1.3 ng/mL Zn(II). The ability of the method was evaluated by analysis of cadmium and zinc in water and alloy samples The text was submitted by the authors in English.  相似文献   

3.
A sensitive and fast method for the simultaneous determination of trace amounts of nickel and cadmium in real samples has been described using differential pulse adsorptive stripping voltammetry (DPASV) by adsorptive accumulation of the N,N′‐bis(salicylaldehydo)4‐carboxyphenylenediamine (BSCPDA)–complex on the hanging mercury drop electrode (HMDE). As supporting electrolyte 0.02 mol L?1 ammonia buffers containing ligand has been used. Optimal analytical conditions were found to be: BSCPDA concentration of 42 μM, pH 9.6 and adsorption potential at ?50 mV versus Ag/AgCl. With an accumulation time of 20 s, the peaks current are proportional to the concentration of nickel and cadmium over the 1–180, and 0.5–200 ng mL?1 with detection limits of 0.06 and 0.03 ng mL?1 respectively. The sensitivity of method for determination of nickel and cadmium were obtained 0.54 and 0.98 nA mL ng?1, respectively. The procedure was applied to simultaneous determination of nickel and cadmium in some real and synthetic artificial samples with satisfactory results.  相似文献   

4.
The amount of mobile forms of Zn, Pb, Cd and Cu in extracts obtained by treating soil samples with ammonium nitrate were determined by an appropriate combination of anodic and cathodic stripping voltammetry with hanging mercury drop electrode. Every analysis required three mercury drops: on the first one, zinc was determined; on the second, cadmium and lead; on the third, copper was determined. Zinc, lead and cadmium were determined by conventional differential-pulse anodic stripping voltammetry. For copper determination, adsorptive differential-pulse cathodic stripping voltammetry with amalgamation using chloride ions as a complexing agent was applied. The standard deviation of the results was from 1 to 10% depending on the metal content in the sample. Voltammetric results were in good agreement with the AAS analysis. No microwave digestion of soil extracts was necessary.  相似文献   

5.
《Electroanalysis》2005,17(21):1985-1990
A new method is presented for determination of cadmium based on cathodic adsorptive stripping of the complex of cadmium with captopril,1‐[(2S)‐3‐mercapto‐2‐methylpropionyl]‐L ‐praline (CPL) at a hanging mercury drop electrode(HMDE). The most suitable operating conditions and parameters, such as pH, deposition potential, deposition time, ligand concentration, and others were selected and the determination of cadmium from aqueous solutions using the standard additions method was possible. Under the optimum conditions and for an accumulation time of 60 s, the measured peak current is proportional to the concentration of cadmium over the range of 1–300 nM. The limit of detection at S/N ratio of 3 was 0.3 nM and a relative standard deviation of 2.5% at 0.1 μM was achieved. The interference of other cations and anions was studied. The method was designed in order to determination of Cd in four analytical grade salts, with satisfactory results.  相似文献   

6.
D B Gomis  E A Garcia 《The Analyst》1990,115(1):89-91
A spectrofluorimetric method for the determination of ultratrace amounts of lead and cadmium is described based on the sequential extraction of the ternary ion-association complexes formed between the cation, a cryptand as the ligand and eosin as a counter ion. A linear working range from the detection limit (0.5 ng ml(-1) to 250 ng ml(-1) of lead and to 1 50 ng ml(-1) of cadmium was obtained. The relative standard deviation was 2-4%. The proposed method has been applied successfully to the determination of lead and cadmium in zinc metals and soft drinks.  相似文献   

7.
West KJ  Pflaum RT 《Talanta》1986,33(10):807-810
The chelating ligand, 2,2'-pyridil bis(2-quinolylhydrazone), has been used for the spectrophotometric determination of zinc and cadmium in synthetic samples. The molar absorptivities of these metal complexes in 80% ethanol-water solution at pH 8 were found to be 4.60 x 10(4) and 5.10 x 10(4) 1.mole(-1).cm(-1) for zinc and cadmium respectively. Beer's law was obeyed for metal-ion concentrations between 1.0 x 10(-6) and 2.5 x 10(-5)M. The limits of detection were found to be 52 and 79 ng ml for zinc and cadmium respectively. The complexes fluoresced in 80% ethanol-water at pH 8 for zinc and at pH 10 for cadmium. The linear range for fluorescence as a function of metal-ion concentration was found to be 5 x 10(-7)-5 x 10(-6)M for both zinc and cadmium. Transition-metal ions interfere severely with both the spectrophotometric and fluorimetric determinations, and must be removed beforehand. An ion-exchange procedure is suitable for this.  相似文献   

8.
A novel, sensitive and selective adsorptive stripping procedure for simultaneous determination of iron, copper and cadmium is presented. The method is based on the adsorptive accumulation of thymolphthalexone (TPN) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the simultaneous determination of iron, copper and cadmium were studied using the Derringer desirability function. The optimum analytical conditions were found to be TPN concentration of 2.0 μM, pH of 9.5, and accumulation potential at ?0.4 V vs. Ag/AgCl with an accumulation time of 60 s. The peak currents are proportional to the concentration of iron, copper and cadmium over the 1–80, 0.5–100 and 1–100 ng mL?1 ranges with detection limits of 0.5, 0.4 and 0.9 ng mL?1, respectively. The R.S.D. at a concentration level of 20 ng mL?1 of iron, copper and cadmium were 2.5%, 0.9% and 1.5% (n=6), respectively. The procedure was applied to the simultaneous determination of iron, copper and cadmium in the tap water and some synthetic samples with satisfactory results.  相似文献   

9.
Different polarographic and voltammetric methods for the determination of Co in the presence of a large excess of zinc are reviewed. Adsorptive stripping voltammetry with in-situ matrix exchange and catalytic adsorptive stripping voltammetric methods are recommended for monitoring Co traces in zinc plant electrolyte. The principles of the catalytic adsorptive stripping voltammetric methods for Co determination are presented. The correct selection of the investigated supporting electrolytes, enabling the monitoring of Co traces in a zinc plant electrolyte by means of catalytic adsorptive methods is also discussed. The catalytic adsorptive voltammetric procedures offer the possibility of the determination of Co or Co and Ni traces in metallic zinc and zinc salts.  相似文献   

10.
《Analytica chimica acta》2003,487(2):229-241
A new differential pulse adsorptive cathodic stripping voltammetric (DPAdCSV) method for the direct determination of cadmium at subnanomolar levels in saline waters based on metal complexation with 2-acetylpyridine salicyloylhydrazone (APSH) and subsequent adsorptive deposition onto a hanging mercury drop electrode (HMDE) is presented. A study strategy based on experimental designs has been followed. Operating conditions were improved with exploratory (Plackett-Burman) and surface response (central composite) experimental designs, involving several chemical and instrumental parameters (pH, ligand concentration, pulse amplitude, time interval for voltage step, voltage step, deposition potential and deposition time). Analytical parameters as repeatability, linearity and accuracy were also investigated and a detection limit (DL) of 0.06 nM was achieved which could be lowered by extending the adsorption time. The interference of other metals and major salts present in seawater was also studied. The method was validated with reference water samples: NIST-SRM 1643d and BCR-CRM 505, showing good concordance with the certified values.  相似文献   

11.
Kubiak WW  Latonen RM  Ivaska A 《Talanta》2001,53(6):1211-1219
Two sequential injection systems have been developed for adsorptive stripping voltammetric measurement. One is for substances adsorbing at mercury, e.g. riboflavin. In this case, a simple arrangement with only sample aspiration is needed. Reproducibility was 3% and detection limit 0.07 μM. The measuring system was applied to determination of riboflavin in vitamin pills and to study the photodegradation process of riboflavin in aqueous solutions. In the second case, metal ions were determined. They have to be complexed before deposition on the mercury surface. Thus, both the sample and the ligand have to be aspirated in the system. In this case, the reproducibility was ≈6% and the detection limit <0.1 ppm for cadmium, lead and copper when complexation with oxine was used. Dimethylglyoxime was used in determination of nickel and cobalt and nioxime complexes were used in determination of nickel and copper. With these complexing agents, the reproducibility was the same as with oxine, but the metals could be determined at concentrations lower than 0.01 ppm. Application of two ligands in a SIA system with AdSV detection was also studied. Simultaneous determination of copper, lead, cadmium and cobalt was possible by using oxine and dimethylglyoxime. Copper and nickel were simultaneously determined by using dimethylglyoxime and nioxime.  相似文献   

12.
Nakagawa G  Tanaka M 《Talanta》1972,19(4):559-565
The use of ligand buffers composed of a chelating agent and an excess of polarographically inert metal is recommended for the selective polarographic determination of a metal in the presence of a second metal, which has a polarographic wave at a less negative potential than the metal to be determined. Theoretical considerations on the optimum ligand concentration and the optimum composition of the ligand buffer are followed by the determination of zinc in cadmium as an example.  相似文献   

13.
A sensitive adsorptive cathodic stripping voltammetry with H‐point standard addition method for simultaneous determination of uranium and cadmium has been developed. The trace amounts of these metal ions can be simultaneously determined using the Levodpa as complexing agent. Optimal conditions were: accumulation time 50 s, accumulation potential 0.0 mV, scan rate 40 mV s?1, supporting electrolyte 0.1 M ammonium buffer pH 9.6, and 1×10?5 M of Levodopa. The results revealed that the cadmium and uranium could be simultaneously determined by H‐point standard addition method with different concentration ratios of uranium to cadmium. The method was successfully applied in a several of real samples.  相似文献   

14.
微波等离子体炬(MPT)是一种具有类似ICP炬管结构的新型等离子体光源,该光源的基本性质已进行了详细的研究。本文采用自制的低功率MPT为激发光源,以氧为工作气体,用微型电热蒸发装置进样,测得铜、锌和镉的检出限分别为3.3、1.4和1.7ng/mL。考察了碱金属元素对铜、锌和镉发射信号的影响,该方法应用于钢样中铜的测定,结果较好。  相似文献   

15.
Microwave assisted pre-treatments for atomic spectrometric determination (inductive coupled plasma-optical emission spectrometry, ICP-OES or flame atomic absorption spectrometry, FAAS) of metallic elements, usually present in antidandruff shampoos, are proposed. They are based on the digestion of the sample with HNO3 into a closed reactor, which is irradiated at 800 W for a few minutes. Selenium was determined by ICP-OES. The limit of detection was 0.11 mg l−1; the relative standard deviation (R.S.D.) for the selenium content in the samples was in the 0.6–3.6% range. The results obtained were in agreement with the label contents and the recovery of the proposed method was in the 100–106% range. Zinc and cadmium were determined by FAAS. The limit of detection for zinc determination was 0.078 mg l−1; the R.S.D. for zinc contents was in the 0.8–8.6% range. A limit of detection of 0.09 mg l−1 was obtained for cadmium determination; the R.S.D. for cadmium contents was in the 0.7–2.7% range. The determinations were performed after two different sample mineralization pre-treatments — dry ashing (in an electric furnace) and wet mineralization (in a microwave oven). Both methodologies provided comparable results for zinc and cadmium determination in shampoos. The proposed microwave assisted digestion procedures allow a precise and accurate determination of selenium, zinc and cadmium in commercial antidandruff shampoos, and the sample pre-treatment is less time-consuming than the classic methods.  相似文献   

16.
A biosensor for the determination of heavy metal cations based on glucose oxidase enzymatic inhibition has been developed. The biosensor was assembled on carbon film electrode supports with glucose oxidase immobilised by cross-linking with glutaraldehyde on top of a film of poly(neutral red) as redox mediator, prepared by electropolymerisation. The biosensor was used to determine the metallic cations, cadmium, copper, lead and zinc in the presence of chosen amounts of glucose. The detection limits were found to be 1 μg L?1 for cadmium, 6 μg L?1 for copper, 3 μg L?1 for lead and 9 μg L?1 for zinc. Inhibition constants were determined by using the Dixon plot, and the type of inhibition induced by the metallic cations was evaluated from Cornish-Bowden plots plus Dixon plots, it being found that the inhibition is reversible and competitive for cadmium, mixed for copper and lead and uncompetitive for zinc. Copper-inhibited glucose oxidase to a greater extent followed by cadmium, lead and zinc. Regeneration of the glucose oxidase response was studied by using Ethylene diamine tetracetic acid metal-chelating agent and the nonionic surfactant Triton X-100. The suitability of the biosensor for determination in foodstuffs or beverages which contain trace concentrations of metals was investigated by performing recovery tests in commercial milk samples.  相似文献   

17.
锌(Ⅱ)-茜素紫络合物的极谱行为及应用   总被引:2,自引:0,他引:2  
用线性扫描示波极谱法研究了锌 ( ) -茜素紫络合物的伏安行为 ,发现在含有 0 .1 mol/L KCl,p H=9.96的 Britton- Robinson缓冲溶液中锌 ( ) -茜素紫络合物产生一灵敏的极谱吸附波 ,其峰电位为 - 1 .2 7V( vs.SCE) ,峰电流与锌 ( )的浓度在 8× 1 0 - 8~ 2× 1 0 - 6 mol/L的范围内呈线性关系 ,检出限为 5× 1 0 - 8mol/L。研究了电极反应机理 ,并用建立的方法成功地测定了发样中的锌  相似文献   

18.
A method for the determination of cadmium, copper, lead, and zinc in biological tissues using small volumes of digest is described. An aluminium heating block is used to digest samples and elements are determined by spike-height flame atomic absorption spectrometry. Interferences have been assessed and the sample decomposition procedure evaluated.  相似文献   

19.
A pulse-polarographic method for the simultaneous determination of traces of nickel, zinc, cobalt and manganese in cadmium and its compounds is described. Interference from the reduction of the cadmium matrix was eliminated by a prior electrolytic deposition of cadmium on a mercury cathode at a controlled potential of –0.90 V vs. S.C.E. Iron in excess interfered with the determination of cobalt and was therefore extracted from the electrolysed solutions. The polarographic determination was performed in 0.1 M lithium acetate -0.025 M lithium thiocyanate as supporting electrolyte. A sample weight of 10 g and a final volume of 10 ml allowed the determination of about 0.08 p.p.m. nickel, 0.01 p.p.m. zinc, 0.02 p.p.m. cobalt and 0.003 p.p.m manganese. Less than 0.01 p.p.m. nickel could be determined with a 0.25 M pyridine 0.05 M potassium chloride supporting electrolyte. Several synthetic samples and commercially available cadmium products were analysed.  相似文献   

20.
The adsorptive bubble separation of zinc and cadmium cations from solution in the presence of ferric and aluminum hydroxides was carried out by means of Tween 80 (nonionic surfactant), and sodium laurate and stearate (anionic surfactants). The mechanism of metal removal is different depending on the nature of the surfactant used. The removal of zinc cations by adsorbing colloid flotation is higher than that of cadmium cations. It increases with increases in the amount of hydroxide precipitate and the concentration of Tween 80. The removal of zinc cations by ion flotation is lower than that of cadmium cations. It does not change with increases in the hydroxide amount. It increases, however, with increased sodium laurate or stearate concentration. Both separation methods turned out to be helpful for studying both the solution's structure and the interactions at the solution-solid interface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号