首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The synthesis of NiO/NiCo2O4 nanoparticles by an eco-friendly, fast, simple and cost-effective approach employing Urtica extract is reported in this study. The NiO/NiCo2O4 nanocomposite were characterized using VSM, FTIR, XRD, and SEM techniques. Moreover, to construct a modified carbon paste electrode, NiO/NiCo2O4 were employed and this sensor was used for dopamine (DA) detection. Using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques, the electrochemical behavior of dopamine at the NiO/NiCo2O4/CPE was investigated. Analysis of dopamine, with a limit of detection (LOD) equal to 0.04 μM, in the concentration range of 0.1–100.0 μM, was facilitated by NiO/NiCo2O4/CPE. Moreover, the satisfactory selectivity for DA determination in the presence of uric acid (UA) and ascorbic acid (AA), was obtained. The suggested new sensor displayed a good reproducibility, sensitivity, and stability for determination of DA in drug and biological samples.  相似文献   

2.
Hierarchical nanocomposites consisting of NiCo2O4 nanorods and NiCo2O4 nanoparticles through a straightforward two-step hydrothermal process was employed as a working electrode to examine the electrochemical behavior of glucose. The NiCo2O4@NiCo2O4 heterostructures was confirmed by the scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray powder diffractometer (XRD), X-ray photoelectron spectroscopy (XPS) and electrochemistry analysis. Results indicated that glucose is electrochemically oxidized with improved sensitivity at the NiCo2O4@NiCo2O4 sensor, compared to NiCo2O4 sensors. Analytical parameters such as the optimal potential (0.45 V), linear range from 0.4 μM to 5.2 mM, limit of detection (1.1 μΜ) (S/N=3), stability and repeatability (2.7 %) demonstrate the suitability of the prepared sensor for glucose analysis. Moreover, the proposed sensor could be used for actual samples analysis in complex matrices.  相似文献   

3.
《Electroanalysis》2018,30(5):910-920
A label‐free DNA biosensor based on magnetite/multiwalled carbon nanotubes/chitosan (Fe3O4/MWCNTs‐COOH/CS) nanomaterial for detection of Bacillus cereus DNA sequences was fabricated. Negatively charged DNA was electrostatically adsorbed onto materials by protonation of positively charged chitosan under acidic conditions. The electrode surface and hybridization process were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimal conditions, the biosensor showed a good linear relationship between peak currents difference (ΔI) and logarithm of the target DNA concentration (Log C) ranging from 2.0×10−13 to 2.0×10−6 M with a detection limit of 2.0×10−15 M (signal/noise ratio of 3). The biosensor also revealed an excellent selectivity to three‐base, completely mismatched and completely matched DNA. This is a simple, fast and friendly method with a low detection limit for the detection of Bacillus cereus specific DNA compared with previously reported electrochemical DNA biosensor. Furthermore, the DNA biosensor may lead to the development of a technology for gold prospecting in the wild.  相似文献   

4.
《Electroanalysis》2018,30(8):1659-1668
PAMAM dendrimer/reduced graphene oxide nanocomposite modified pencil graphite electrode (PAMAM/RGO/PGE) was used to fabricate an electrochemical DNA biosensor for determination of Rituxan (RTX) at low concentrations, for the first time. The fabricated biosensor was characterized with FE‐SEM, EIS, and CV techniques. The ds‐DNA/PAMAM/RGO/PGE was used as a working electrode to study the interaction between the RTX and salmon sperm ds‐DNA by DPV technique. Because of the interaction between the drug and DNA leads to a decrease in the guanine oxidation peak current, it was used as an indicator for the determination of the RTX. Under the optimized experimental conditions, a wide linear relationship between RTX concentration and guanine signal was obtained within the range of 7.0 to 60.0 μmol L−1 and 60.0 to 300.0 μmol L−1 with a low detection limit (0.56 μmol L−1). To clarify the interaction mechanism between the RTX and the ds‐DNA, DPV and UV‐Vis measurements were used. The reproducibility, stability, and performance of the constructed biosensor was examined by quantitative measuring RTX in pharmaceutical and human serum samples with good precision (RSD; 2.0–6.0 %) and acceptable recoveries (100.04–101.95 %).  相似文献   

5.
A facile synthesis strategy of reduced graphene oxide (RGO)-octahedral Mn3O4 (oct-Mn3O4) nanocomposites using in situ one-pot hydrothermal reaction was reported. The RGO-oct-Mn3O4 nanocomposites were drop-casted onto the surface of glassy carbon electrode (GCE) to obtain RGO-oct-Mn3O4/GCE. DPV results revealed that the performance of RGO-oct-Mn3O4/GCE towards metronidazole displayed a linear ranging from 0.1 to 9.5 μM with a detection limit of 0.037 μM. For sulfamonomethoxine, it exhibited a linear ranging from 1 to 95 μM with a detection limit of 0.27 μM. Moreover, the proposed sensor had good anti-interference capability, high stability, satisfactory reproducibility, and was successfully applied in real samples.  相似文献   

6.
《Electroanalysis》2003,15(7):613-619
The interaction of arsenic trioxide (As2O3) with calf thymus double‐stranded DNA (dsDNA), calf thymus single‐stranded DNA (ssDNA) and also 17‐mer short oligonucleotide (Probe A) was studied electrochemically by using differential pulse voltammetry (DPV) with carbon paste electrode (CPE) at the surface and also in solution. Potentiometric stripping analysis (PSA) was employed to monitor the interaction of As2O3 with dsDNA in solution phase by using a renewable pencil graphite electrode (PGE). The changes in the experimental parameters such as the concentration of As2O3, and the accumulation time of As2O3 were studied by using DPV; in addition, the reproducibility data for the interaction between DNA and As2O3 was determined by using both electrochemical techniques. After the interaction of As2O3 with dsDNA, the DPV signal of guanine was found to be decreasing when the accumulation time and the concentration of As2O3 were increased. Similar DPV results were also found with ssDNA and oligonucleotide. PSA results observed at a low DNA concentration such as 1 ppm and a different working electrode such as PGE showed that there could be damage to guanine bases. The partition coefficients of As2O3 after interaction with dsDNA and ssDNA in solution by using CPE were calculated. Similarly, the partition coefficients (PC) of As2O3 after interaction with dsDNA in solution was also calculated by PSA at PGE. The features of this proposed method for the detection of DNA damage by As2O3 are discussed and compared with those methods previously reported for the other type of DNA targeted agents in the literature.  相似文献   

7.
A novel protocol for immobilization of horseradish peroxidase (HRP) onto diazonium functionalized screen‐printed gold electrode (SPGE) has been successfully developed. This protocol involved 1) electrochemical reduction of p‐nitrophenyl diazonium salts synthesized in situ in acidic aqueous solution to graft a layer of p‐nitrophenyl on SPGE, 2) electrochemical reduction of the nitro groups to convert to amines, 3) chemical reaction with nitrous acid to transform the amine to diazonium derivative and 4) chemical coupling of the enzyme with the diazonium group to form a covalent diazo bond. The fabricated biosensor showed the direct electrochemistry of HRP and displayed electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) without any mediator. The biosensor exhibited fast amperometric response to H2O2. The catalytic current increased with increasing H2O2 concentration from 5 μM to 30 μM and the detection limit of the biosensor was 2 μM. The biosensor exhibited acceptable sensitivity, good reproducibility and long‐term stability.  相似文献   

8.
Non‐enzymatic glucose sensor is greatly expected to take over its enzymatic counterpart in the future. In this paper, we reported on a facile strategy to construct a non‐enzymatic glucose sensor by use of NiCo2O4 hollow nanocages (NiCo2O4 HNCs) as catalyst, which was derived from Co‐based zeolite imidazole frame (ZIF‐67). The NiCo2O4 HNCs modified glassy carbon electrode (NiCo2O4 HNCs/GCE), the key component of the glucose sensor, showed highly electrochemical catalytic activity towards the oxidation of glucose in alkaline media. As a result, the proposed non‐enzymatic glucose sensor afforded excellent analytical performances assessed with the aid of cyclic voltammetry and amperometry (i–t). A wide linear range spanning from 0.18 μΜ to 5.1 mM was achieved at the NiCo2O4 HNCs/GCE with a high sensitivity of 1306 μA mM?1 cm?2 and a fast response time of 1 s. The calculated limit of detection (LOD) of the sensor was as low as 27 nM (S/N=3). Furthermore, it was demonstrated that the non‐enzymatic glucose sensor showed considerable anti‐interference ability and excellent stability. The practical application of the sensor was also evaluated by determination of glucose levels in real serum samples.  相似文献   

9.
A novel electrochemical biosensor, DNA/hemin/nafion–graphene/GCE, was constructed for the analysis of the benzo(a)pyrene PAH, which can produce DNA damage induced by a benzo(a)pyrene (BaP) enzyme-catalytic product. This biosensor was assembled layer-by-layer, and was characterized with the use of cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and atomic force microscopy. Ultimately, it was demonstrated that the hemin/nafion–graphene/GCE was a viable platform for the immobilization of DNA. This DNA biosensor was treated separately in benzo(a)pyrene, hydrogen peroxide (H2O2) and in their mixture, respectively, and differential pulse voltammetry (DPV) analysis showed that an oxidation peak was apparent after the electrode was immersed in H2O2. Such experiments indicated that in the presence of H2O2, hemin could mimic cytochrome P450 to metabolize benzo(a)pyrene, and a voltammogram of its metabolite was recorded. The DNA damage induced by this metabolite was also detected by electrochemical impedance and ultraviolet spectroscopy. Finally, a novel, indirect DPV analytical method for BaP in aqueous solution was developed based on the linear metabolite versus BaP concentration plot; this method provided a new, indirect, quantitative estimate of DNA damage.  相似文献   

10.
At present, a highly sensitive hydrogen peroxide (H2O2) sensor is fabricated by ferrocene based naphthaquinone derivatives as 2,3‐Diferrocenyl‐1,4‐naphthoquinone and 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone. These ferrocene based naphthaquinone derivatives are characterized by H‐NMR and C‐NMR. The electrochemical properties of these ferrocene based naphthaquinone are investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) on modified glassy carbon electrode (GCE). The modified electrode with ferrocene based naphthaquinone derivatives exhibits an improved voltammetric response to the H2O2 redox reaction. 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone show excellent non‐enzymatic sensing ability towards H2O2 response with a detection limitation of 2.7 μmol/L a wide detection range from 10 μM to 400 μM in H2O2 detection. The sensor also exhibits short response time (1 s) and good sensitivity of 71.4 μA mM?1 cm?2 and stability. Furthermore, the DPV method exhibited very high sensitivity (18999 μA mM?1 cm?2) and low detection limit (0.66 μM) compared to the CA method. Ferrocene based naphthaquinone derivative based sensors have a lower cost and high stability. Thus, this novel non‐enzyme sensor has potential application in H2O2 detection.  相似文献   

11.
Horseradish peroxidase, previously modified with 1‐adamantane moieties, was supramolecularly immobilized on gold electrodes coated with perthiolated β‐cyclodextrin. The functionalized electrode was employed for the construction of an amperometric biosensor device for hydrogen peroxide using 1 mM hydroquinone as electrochemical mediator. The biosensor exhibited a fast amperometric response (6 s) and a good linear response toward H2O2 concentration between 12 μM and 450 μM. The biosensor showed a sensitivity of 1.02 mA/M cm2, and a very low detection limit of 5 μM. The electrode retained 97% of its initial electrocatalytic activity after 30 days of storage at 4 0C in 50 mM sodium phosphate buffer, pH 7.0.  相似文献   

12.
In this paper, nano‐gold modified carbon paste electrode (NGMCPE) was employed to develop an electrochemical DNA hybridization biosensor. The proposed sensor was made up by immobilization of 15‐mer single stranded oligonucleotide probe for detection of target DNA. Hybridization detection relies on the alternation in guanine oxidation signal following hybridization of the probe with complementary genomic DNA. The guanine oxidation was monitored using differential pulse voltammetry (DPV). Different factors such as activation potential, activation time and probe immobilization conditions were optimized. The selectivity of the sensor was investigated by non‐complementary oligonucleotides. Diagnostic performance of the biosensor was described and the detection limit was found 1.9 × 10?13 M at the NGMCPE surface. All of the investigations were performed in both CPE and NGMCPE and finally their results were compared.  相似文献   

13.
A new convenient strategy to fabricate a third‐generation hydrogen peroxide biosensor was described. The screen‐printed carbon electrode (SPCE) was first modified with a layer of 4‐nitrophenyl assembled from the 4‐nitroaniline diazonium salt synthesized in situ in acidic aqueous solution. Next, the nitro groups were converted to amines followed by crosslinking to the horseradish peroxidase (HRP) by glutaraldehyde. The redox chemistry of the active center of the HRP was observed and the HRP‐modified electrode displayed electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) without any mediators. H2O2 was determined in a linear range from 5.0 μM to 50.0 μM, with a detection limit of 1.0 μM. Furthermore, the biosensor exhibited fast amperometric response, good reproducibility and long‐term stability.  相似文献   

14.
《Electroanalysis》2003,15(3):219-224
A novel hydrogen peroxide biosensor has been constructed based on the characteristics of the carbon nanotube. The multiwall carbon nanotube (MWNT) was used as a coimmobilization matrix to incorporate horseradish peroxidase (HRP) and electron transfer mediator methylene blue (MB) onto a glassy carbon electrode surface. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of methylene blue as an electron carrier between the immobilized peroxidase and the surface of glassy carbon electrode. The amperometric response of this resulting biosensor to H2O2 shows a linear relation in the range from 4 μM to 2 mM. The detection limit was 1 μM when the signal to noise ratio is 3. The presence of dopamine and ascorbic acid hardly affects the sensitive determination of H2O2. This biosensor also possesses very good stability and reproducibility.  相似文献   

15.
《Electroanalysis》2017,29(6):1518-1523
A sensitive and selective amperometric H2O2 biosensor was obtained by utilizing the electrodeposition of Pt flowers on iron oxide‐reduced graphene oxide (Fe3O4/rGO) nanocomposite modified glassy carbon electrode (GCE). The morphology of Fe3O4/rGO and Pt/Fe3O4/rGO was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), respectively. The step‐wise modification and the electrochemical characteristics of the resulting biosensor were characterized by cyclic voltammetry (CV) and chronoamperometry methods. Thanks to the fast electron transfer at the Pt/Fe3O4/rGO electrode interface, the developed biosensor exhibits a fast and linear amperometric response upon H2O2. The linear range of Pt/Fe3O4/rGO is 0.1∼2.4 mM (R2=0.998), with a sensitivity of 6.875 μA/mM and a detection limit of 1.58 μM (S/N=3). In addition, the prepared biosensor also provides good anti‐interferent ability and long‐term stability due to the favorable biocompatibility of the electrode interface. The proposed sensor will become a reliable and effective tool for monitoring and sensing the H2O2 in complicate environment.  相似文献   

16.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

17.
A novel method for preparation of hydrogen peroxide biosensor was presented based on immobilization of hemoglobin (Hb) on carbon‐coated iron nanoparticles (CIN). CIN was firstly dispersed in a chitosan solution and cast onto a glassy carbon electrode to form a CIN/chitosan composite film modified electrode. Hb was then immobilized onto the composite film with the cross‐linking of glutaraldehyde. The immobilized Hb displayed a pair of stable and quasireversible redox peaks and excellent electrocatalytic reduction of hydrogen peroxide (H2O2), which leading to an unmediated biosensor for H2O2. The electrocatalytic response exhibited a linear dependence on H2O2 concentration in a wide range from 3.1 μM to 4.0 mM with a detection limit of 1.2 μM (S/N=3). The designed biosensor exhibited acceptable stability, long‐term life and good reproducibility.  相似文献   

18.
A novel method to fabricate a third‐generation hydrogen peroxide biosensor was reported. The electrode was first derivatized by electrochemical reduction of in situ generated 4‐carboxyphenyl diazonium salt (4‐CPDS) in acidic aqueous solution yielded stable 4‐carboxyphenyl (4‐CP) layer. The horseradish peroxidase (HRP) enzyme was then covalently immobilized by amidation between NH2 terminus of enzyme and COOH terminus of 4‐CP film making use of the carbodiimide chemistry. Electrodeposition conditions used to control electrode functionalization density and film electron transfer kinetics were assessed by chronoamperometry and electrochemical impedance spectroscopy. The immobilized HRP displayed excellent electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) without any mediators. The effect of various operational parameters was explored for optimum analytical performance. The reported biosensor exhibited fast amperometric response (within 5 s) to H2O2. The detection limit of the biosensor was 5 μM, and linear range was from 20 μM to 20 mM. Furthermore, the biosensor exhibited high sensitivity, good reproducibility, and long‐term stability.  相似文献   

19.
In this study, we present a novel approach to prepare of a colorimetric chemical sensor for H2O2 and a glucose biosensor basing on the use of peroxidase-like activity of silver nanoparticles decorated on reduced graphene oxide sheets (AgNPs@rGO) nanocomposite. Herein, AgNPs@rGO nanocomposite was synthesized by a one-step hydrothermal reducing method and its physico-chemical properties were characterized by X-ray diffraction (XRD), Transmission Electron Microscopy (TEM), Ultraviolet–visible spectroscopy (UV–Vis), Fourier-Transform Infrared spectroscopy (FT-IR) and Energy Dispersive X-ray spectroscopy (EDX). Obtained evaluation results shown that the synthesized AgNPs/rGO nanocomposite has performed an efficient peroxidase-like activity for the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMBred) by H2O2, leading to the oxidized form (TMBox) which presents a typical blue color (maximum of absorbance at λmax = 655 nm). A colorimetric assay for H2O2 detection was designed and fabricated with a limit of detection of 20 μM. Moreover, we have used of AgNPs/rGO nanocomposite combining with glucose oxidase (GOx) to develop of a colorimetric glucose biosensor with a low limit of detection of 40 μM and a linear dynamic range from 125 μM to 1 mM. This glucose test was applied to the detection of glucose in human serum samples.  相似文献   

20.
We studied sensor application of a graphene oxide and hematite (α‐Fe2O3/GO) composite electrode well‐characterized by the SEM and XRD. Through differential pulse voltammetry (DPV), oxidation of dexamethasone sodium phosphate (DSP) was studied at the surface of a glassy carbon electrode (GCE) modified with graphene oxide nanosheets (GO) and the α‐Fe2O3/GO composite. The values of the transfer coefficient (α) and the diffusion coefficient (D) of DSP were 0.5961 and 4.71×10?5 cm2 s?1 respectively. In the linear range of 0.1–50 μM, the detection limit (DL) was 0.076 μM. In the second step, a GCE was modified with α‐Fe2O3/GO composite and the DSP measurement step was repeated to analyzed and compare the effects of hematite nanoparticles present on graphene oxide surfaces. According to the results, α and D were 0.52 and 2.406×10?4 cm2 s?1 respectively and the DL was 0.046 μM in the linear range of 0.1–10.0 μM. The sensor is simple, inexpensive and uses blood serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号