首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The pursuit of ultraflexible sensors has arisen from the recent implementation of electrochemical sensors into wearable clothing where extensive mechanical stress upon the sensing platform is likely to occur. Such scenarios have witnessed screen‐printed electrodes being incorporated into the waistband of undergarments for the determination of key analytes while others have reported incorporation into a neoprene wetsuit. In these conformations, the substrates which the sensors are printed upon need to be ultraflexible and capable of withstanding extensive individual mechanical stress. Therefore the composition, thickness and its combination of screen‐printed ink require extensive consideration. A common short‐coming within the field of screen‐printed derived sensors is the lack of consideration towards the substrate material employed, and is rather in favour of the development of new electrode geometries and screen‐printing inks. In this paper we explore the screen‐printing of graphite based electroanalytical sensing platforms onto graphic paper commonly used in house‐hold printers, and for the first time both tracing paper and ultraflexible polyester‐based substrates are used. These sensors are electrochemically benchmarked with the redox probes hexaammine‐ruthenium(III) chloride and potassium ferrocyanide(II). The effect of mechanical contortion upon two types of electrode substrates is also performed where it was found that these ultraflexible based polyester‐based electrodes are superior to the previously reported ultraflexible paper electrodes since they can withstand extensive mechanical contortion, yet they still give rise to useful electrochemical performances. Most importantly the ultraflexible polyester electrodes do not suffer from capillary action as observed in the case of paper‐based sensors causing the solution to wick‐up the electrode towards the electrical connections resulting in electrical shorting, therefore compromising the electrochemical measurement; as such this new substrate can be used as a replacement for paper‐based substrates and yet still be resilient to extreme mechanical contortion. A new configuration is also explored using these electrode substrate supports where the working carbon electrode contains the electrocatalyst, cobalt(II) phthalocyanine (CoPC), and is benchmarked towards the electroanalytical sensing of the model analytes citric acid and hydrazine which demonstrate excellent sensing capabilities in comparison to previously reported screen‐printed electrodes.  相似文献   

2.
This study examines the influence of textile substrates upon the behavior of wearable screen‐printed electrodes and demonstrates the attractive sensing properties of these sensors towards the detection of nitroaromatic explosives. Compared to electrodes printed on common cotton or polyester substrates, GORE‐TEX‐based electrochemical sensors display reproducible background cyclic voltammograms, reflecting the excellent water‐repellant properties of the GORE‐TEX fabric. The wetting properties of different printed textile electrodes are elucidated using contact angle measurements. The influence of laundry washing and mechanical stress is explored. The GORE‐TEX‐based printed electrodes exhibit favorable detection of 2,4‐dinitrotoluene (DNT) and 2,4,6‐trinitrotoluene (TNT) explosives, including rapid detection of DNT vapor.  相似文献   

3.
In our previous paper (Analyst, 2014 , 139, 5339) we introduced the concept of the back‐to‐back electrochemical design where the commonly overlooked back of screen‐printed electrodes are utilised to provide electroanalytical enhancements in screen‐printed electroanalytical sensors. In this configuration the overall sensor comprises of a flexible polyester substrate which has a total of two working, counter and reference electrodes present on the sensor, with a set of electrodes on each side of the substrate. The sensors are designed to allow for a commonly shared electrical connection to the potentiostat and do not require any specialised connections. In this paper we demonstrate proof‐of‐concept extending the electroanalytical utility of the back‐to‐back screen‐printed electrode sensors to bulk modified single‐walled carbon‐nanotubes and electrocatalytic cobalt phthalocyanine microband electrodes. The electroanalytical applications of these novel electrode configuration are exemplified towards the sensing of dopamine, capsaicin and hydrazine. This paper demonstrates the versatility of the back‐to‐back configuration where different surface modifications can be readily employed giving rise to enhancements in sensor performance.  相似文献   

4.
In this work an electrochemical immunoassay, based on a direct competitive assay, was developed using magnetic beads as solid phase and carbon screen‐printed arrays as transducers for the detection of sulfonamides in food matrices such as honey. Magnetic beads coated with protein A were modified by immobilisation of specific antibodies and then the competition between the target analyte and the corresponding analyte‐labelled with an enzyme was carried out; after the immunosensing step, beads were captured by a magnet onto the working surfaces of a screen‐printed eight‐electrodes array for a multiple electrochemical detection. Screen‐printed eight‐electrodes arrays were chosen as transducers due to the possibility to repeat multiple analysis and to test different samples simultaneously. Alkaline Phosphatase (AP) was used as enzyme label and Differential Pulse Voltammetry (DPV) as fast electrochemical technique. Calibration curves demonstrate that the developed electrochemical immunoassay was able to detect this class of drugs in standard solutions at low concentrations (ng/mL levels). The short incubation times (25 min) and the fast electrochemical measurement (10 sec) make of these systems a possible alternative to classic ELISA tests.  相似文献   

5.
《Electroanalysis》2018,30(8):1616-1620
This paper describes a simple, convenient approach to the fabrication of microband electrodes and microband biosensors based on screen printing technology. These devices were printed in a three‐electrode configuration on one strip; a silver/silver chloride electrode and carbon counter electrode served as reference and counter electrodes respectively. The working electrodes were fabricated by screen‐printing a water‐based carbon ink containing cobalt phthalocyanine for hydrogen peroxide detection. These were converted into a glucose microband biosensor by the addition of glucose oxidase into the carbon ink. In this paper, we discuss the fabrication and application of glucose microband electrodes for the determination of glucose in cell media. The dimensions (100–400 microns) of the microband electrodes result in radial diffusion, which results in steady state responses in the absence of stirring. The microband biosensors were investigated in cell media containing different concentrations of glucose using chronoamperometry. The device shows linearity for glucose determination in the range 0.5 mM to 2.5 mM in cell media. The screen‐printed microband biosensor design holds promise as a generic platform for future applications in cell toxicity studies.  相似文献   

6.
《Electroanalysis》2005,17(21):1991-1994
The development and performance of an end‐column amperometric detection system integrated with disposable screen‐printed electrodes for capillary electrophoresis is presented. In this system, the electrode and capillary can be easily replaced and the capillary/electrode alignment procedure is straightforward. The use of easily replaceable screen‐printed electrodes offers a tremendous benefit for capillary electrophoresis applications requiring frequent replacement of the working electrode due to fouling. This simple and convenient system is very attractive for routine analyses by capillary electrophoresis with electrochemical detection. The separation and determination of uric acid in human urine is presented.  相似文献   

7.
In this study, we report the development of a sensitive label‐free impedimetric sensor based on molecularly imprinted polymer (MIP) as biomimetic receptor coupled with screen‐printed electrodes (SPEs) for the detection of vascular endothelial growth factor (VEGF). Firstly, electropolymerization of o‐phenylenediamine (o‐PD) in the presence of VEGF molecule by cyclic voltammetry was performed onto graphite screen‐printed electrodes. The solvent extraction of the target was then carried out. The MIP based sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Using optimized experimental conditions, the single‐use MIP‐based sensor showed a good analytical performance for VEGF detection from 20 to 200 pg mL?1 with limit of detection of 0.08 pg mL?1. Finally, the developed MIP‐based sensor in human serum samples was also tested.  相似文献   

8.
The synergistic use of Nafion polymeric membrane and in situ electrodeposited bismuth film is a worthwhile strategy to develop electrochemical sensors for the detection of Cd2+ and Pb2+. However, Nafion thin films morphological and conductivity properties have a strong dependence on the environmental conditions, such as relative humidity and temperature, while the bismuth in situ electroplating can affect the repeatability of measurements. With the aim to overcome these drawbacks, the effects of the storage environmental conditions were investigated to improve the morphological stability and electroanalytical performances of Nafion film‐based sensor for the detection of Cd2+ and Pb2+. Nafion‐coated graphite‐based screen‐printed electrodes were stored at different humidity and temperature conditions and characterised by using square wave anodic stripping voltammetry, cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. Significant differences were observed at the varying of humidity conditions, with an enhancement of sensor electrochemical performances at lower humidity. Furthermore, different approaches for bismuth in situ electrodeposition on Nafion‐coated screen‐printed electrodes were compared by using overlap or removal approach. This study disclosed considerable differences in the electrochemical performances and morphology of the resulting bismuth‐sensor, obtaining an enhancement of the working stability for the removal approach.  相似文献   

9.
4‐(4,6‐Diaminopyrimidin‐2‐ylthio) phthalocyaninatocobalt(II) (CoPyPc) was iodine doped, and its electrocatalytic properties explored. Physical characterization techniques such as UV‐vis, X‐ray photoelectron, electron paramagnetic resonance and infra‐red spectroscopy were used. Cyclic voltammetry, electrochemical impedance spectroscopy and rotating disk electrode were used for electrochemical characterization of electrodes modified with the prepared phthalocyanine and its nanocomposites. The electrocatalytic effect of a new iodine‐doped cobalt phthalocyanine derivative supported on multiwalled carbon nanotubes was then investigated towards oxygen reduction reaction. The electrocatalytic activity of the iodine‐doped cobalt phthalocyanine was found to be superior in terms of current over the undoped phthalocyanine nanocomposite.  相似文献   

10.
Waste of electrical and electronic equipment is an interesting secondary resource of base and precious metals. Particularly the use of thiourea‐leaching in acidic medium was proposed for noble metals recovery. In this work, a novel and easy‐to‐use electrochemical sensor was developed, aimed to test thiourea from leaching solutions containing significant thiourea and copper amounts. The sensor was constructed using silver nanoparticles (AgNPs) deposited on screen‐printed electrodes. Its performance was studied in a synthetic leaching solution; changes in the overall surface charge of AgNPs resulting in changes in the charge‐transfer resistance for the copper ions were evaluated by electrochemical impedance spectroscopy.  相似文献   

11.
An electrochemical DNA hybridization biosensor was developed for the detection of DNA hybridization using MDB and proflavine as electrochemical labels. The biosensor was based on the interaction of 7-dimethyl-amino-1,2-benzophenoxazi-nium Meldola’s Blue (MDB) and proflavine with double stranded DNA (dsDNA) The electrochemical behaviour of MDB and proflavine as well as its interaction with double stranded (dsDNA) were investigated by cyclic (CV) and square wave voltammetry (SWV) and screen printed electrodes (ScPE). Furthermore, DNA-hybridization biosensors were developed for the detection of hybridization between oligonucleotides, which was detected by studying changes in the voltammetric peaks of MDB (reduction peak at −0.251 V) and proflavine (reduction peak at 0.075 V). MDB and proflavine were found to intercalate between the base pairs of dsDNA and oligonucleotides. Several factors affecting the dsDNA or oligonucleotides immobilization, hybridization and indicator preconcentration and interaction time, were investigated. As a result of the interaction of MDB with dsDNA and hybridized oligonucleotides, the voltammetric signals of MDB increased. Furthermore, guanine’s oxidation peak (at 0.901 V) was decreased as MDB’s concentration was increased. As a result of the interaction of proflavine with dsDNA and hybridized oligonucleotides, the voltammetric signals of proflavine decreased. These results were similar for carbon paste and screen printed electrodes. A comparison of the performance between CPE and ScPE was done. Our results showed that lower concentrations of MDB and proflavine were detected using screen printed electrodes. Moreover, reproducibility was better using screen printed electrodes and the detection was faster (regarding the experimental steps), but they are more cost effective.   相似文献   

12.
《Electroanalysis》2006,18(3):267-274
In this paper, we describe a simple and effective infrared (IR) spectroelectrochemical cell for detecting species generated from an electrochemical system featuring low‐IR‐reflectivity electrodes. The IR detection mode of attenuated total reflection (ATR) was employed to construct the spectroelectrochemical cell. Two kinds of electrodes, platinum (Pt) and screen‐printed carbon (SPC), were used to examine the performance of this new cell in detection of electroactive species generated by cyclic voltammetry. Because data generated from highly reflective electrodes are available in the literature, Pt electrode was used to characterize the performances of the developed spectroelectrochemical cell. Results indicated that species generated electrochemically can be observed readily and their responses were comparable to those described in the literature. The cell volume could be lower than 300 μL, which suggests that this approach may be very useful to obtain chemical information during electrochemistry for biological fluids with limited sample volumes. By examining the electrochemical behavior of several amino acids using both Pt and SPC electrodes, the redox behaviors can be readily observed indicating a new spectroelectrochemical cell was successfully developed for the purpose of using of SPC electrode.  相似文献   

13.
We report the direct electrochemistry of cytochrome c at screen printed graphite electrodes which exhibits quasi-reversible voltammetric responses without the need for any chemical or electrochemical pre-treatment, use of mediators or nanomaterials. Through voltammetric studies and X-ray photoelectron spectroscopy (XPS) it is shown that carbonyl and carboxylic surface oxygenated species likely residing at edge plane like- sites/defects of the graphite comprising the screen printed electrodes are responsible for the favourable interaction of the cytochrome c with that of the screen printed electrochemical sensing platform.  相似文献   

14.
A novel synthesized tetraamino cobalt(II) phthalocyanine monomer was used for the fabrication of a sensor by electrochemical polymerization. A disposable electrochemical sensor based on the use of a screen printed carbon electrode covered with an electropolymerized film of tetraamino cobalt(II) phthalocyanine for the determination of L-dopa in pharmaceutical tablets and biological samples was described. Cyclic voltammetry and electrochemical impedance spectroscopy were performed for the characterization of the bare and modified electrode. For the electrochemical detection of L-dopa differential pulse voltammetry was used. The proposed method exhibits a good response towards electrooxidation of L-dopa in the linear concentration range: from 0.1 to 1000.0 μmol L−1 in BRB pH=2.0, with a detection limit of 0.03 μmol L−1 and from 1 to 1000 μmol L−1 in PBS pH=7.4, with a detection limit of 0.33 μmol L−1. Due to the fact that the developed sensor was applied in two different types of real samples, two buffer media were used, BRB pH=2.0 for pharmaceutical and urine samples and PBS pH=7.4 for whole blood samples. The proposed pCoTAPc/SPCE was successfully applied for the determination of L-dopa in pharmaceutical tablets, urine and in whole blood samples with satisfactory results.  相似文献   

15.
《Electroanalysis》2017,29(11):2470-2482
We report on the π–π interactions between graphene quantum dots (GQDs) and the following cobalt phthalocyanine derivatives: cobalt monocarboxyphenoxy phthalocyanine (complex 1 ), cobalt tetracarboxyphenoxyphthalocyanine (complex 2 ), and cobalt tetraaminophenoxy phthalocyanine (complex 3 ). The conjugates (conj) with GQDs are represented as 1 @GQDs(conj), 2 @GQDs(conj) and 3 @GQDs(conj), respectively. The resulting phthalocyanine/GQDs conjugates were adsorbed on containing a glassy carbon electrode (GCE) using the drop and dry method. We explore the electrochemical properties of phthalocyanines functionalized with both electron withdrawing groups and electron donating groups when non‐covalently linked to the π‐electron rich graphene quantum dots. GCE/ 3, GCE/ 2 @GQDs(conj) and GCE/ 1 @GQDs(conj) had the lowest limits of detection (LOD). Sequentially modified electrodes showed less favourable detection limits compared to the conjugates.  相似文献   

16.
This work presents a disposable bismuth‐antimony film electrode fabricated on screen‐printed electrode (SPE) substrates for lead(II) determination. This bismuth‐antimony film screen‐printed electrode (Bi‐SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi‐SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen‐printed electrodes (BiSPE), antimony film screen‐printed electrodes (SbSPE) and bismuth‐antimony film glassy carbon electrodes (Bi‐SbGC). Under optimized conditions, the Bi‐SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 µg/L. The Bi‐SbSPE has been demonstrated successfully to detect lead in river water sample.  相似文献   

17.
《Electroanalysis》2017,29(7):1731-1740
This work reports on the development of sensors for the detection of hydrazine using glassy carbon electrodes (GCE) modified with phthalocyanines through click chemistry. Tetrakis(5‐hexyn‐oxy) cobalt(II) phthalocyanine (complex 2 ) and tetrakis(5‐hexyn‐oxy) nickel(II) phthalocyanine (complex 3 ) were employed as electrode modifiers for hydrazine detection. The GCE was first grafted via the in situ diazotization of a diazonium salt, rendering the GCE surface layered with azide groups. From this point, the 1, 3‐dipolar cycloaddition reaction, catalysed by a copper catalyst was utilised to “click” the phthalocyanines to the surface of the grafted GCE. The modified electrodes were characterized by scanning electrochemical microscopy, X‐ray photoelectron spectroscopy and cyclic voltammetry. The electrografted CoP 2 ‐clicked‐GCE and NiP 3 ‐clicked‐GCE exhibited electrocatalytic activity towards the detection of hydrazine. The limit of detection (LoD) for the CoPc‐GCE was 6.09 μM, while the NiPc‐GCE had a LoD of 8.69 μM. The sensitivity was 51.32 μA mM−1 for the CoPc‐GCE and 111.2 μA mM−1 for the NiPc‐GCE.  相似文献   

18.
This paper introduces an interesting analyte derivatization approach for improved electrochemical detection of amoxicillin (one of the most frequently used β‐lactam antibiotics). It is based on the well‐known chemical conversion of catechols to o‐quinones by MnO2 that can be subsequently easily determined by electrochemical reduction at inexpensive screen‐printed carbon electrodes. The MnO2 reactor is essential to the proposed amperometric sensor not only to increase the electroactivity but also to achieve the detection selectivity. Under the optimized conditions of applied potential=0.0 V vs. Ag/AgCl and flow rate=500 μL/min, the measurement range was over 3 orders of magnitude with a detection limit (S/N=3) of 17 nM.  相似文献   

19.
We report the fabrication of disposable and flexible screen printed microelectrodes which are characterised with microscopy and cyclic voltammetry. These new type of screen printed electrochemical platforms consist of micro-sized graphite typically with radii of 60 to 100 microns are defined by an inert dielectric. The advantage of this type of electrochemical sensing platform is that each microelectrode is disposable and cost effective and thus does not require extensive cleaning or electrode pre-treatment between measurements. Prior to measurements the screen printed microelectrode needs only to be calibrated with a suitable redox probe, as is typically the case with microelectrodes. We show proof of concept that the screen printed microelectrodes are advantageous for electro-analytical measurements with the example of determination of lead via cathodic stripping voltammetry. The use of graphite screen printed microelectrodes allows comparable detection limits to that obtained in the literature at insonated boron doped diamond electrodes, without the need for power ultrasound – which otherwise limits the widespread applicability and ease of measurement.  相似文献   

20.
《Electroanalysis》2017,29(2):616-621
Simple and fast methods for the monitoring of phenol‐like compounds are relevant in diverse fields ranging from waste management to neurosciences. Laccases are copper‐containing enzymes, which, depending on their origin, are able to oxidize different phenol compounds at different pH conditions. Through adequate laccase immobilization, disposable screen printed electrodes can be used as interphase to build amperometric phenol sensors. In this work three different laccases were studied for the determination of phenol‐like compounds, two of them are isoenzymes from Trametes trogii and the third one from Rhus vernicifera . Their immobilization on screen printed electrodes is presented for the construction of amperometric sensors. The electrode substrate is composed by graphite screen printed electrodes modified with carbon nanotubes and silica microspheres where, depending on the application, one of the three laccases is adsorbed. As each laccase shows an optimum working pH, they were conveniently selected to determine dopamine at physiological pH and catechol at acid pH. Determinations in the micromolar range were possible in both cases. Chronoamperometry shows to be an effective technique for their determinations, simpler than other electrochemical methods already presented in the literature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号