首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Zhang M  Dai W  Yan M  Ge S  Yu J  Song X  Xu W 《The Analyst》2012,137(9):2112-2118
An ultrasensitive electrochemiluminescence (ECL) immunosensor was developed using PtAg@carbon nanocrystals (CNCs) as excellent labels based on carbon nanotubes-chitosan/AuNPs (CNT-CHIT/AuNPs) composite modified screen-printed carbon electrodes (SPCEs) for prostate protein antigen (PSA) detection. The CNCs were obtained simply by electro-oxidation of graphite with abundant carboxyl groups at their surfaces. The PtAg bimetallic nanocomposites with hierarchically hollow structures were fabricated through simple replacement reaction using dealloyed nanoporous silver (NPS) as both a template and reducing agent. Structure characterization was obtained by means of transmission electron microscope (TEM) and scanning electron microscope (SEM) images. The PtAg@CNCs composites exhibit a 6 times higher ECL intensity than the pure CNCs labeled anti-PSA. The as-prepared CNT-CHIT/AuNPs composite can attach more antibody than pure CNTs. Due to the dual-amplification techniques, the concentrations of PSA were obtained in the range from 1 pg mL(-1) to 50 ng mL(-1) with a detection limit of 0.6 pg mL(-1). Finally, the as-proposed ECL immunosensor has the advantages of high sensitivity, specificity and stability and could become a promising technique for tumor marker detection.  相似文献   

2.
报道了一种基于金纳米粒子(AuNPs)双重信号放大的高灵敏电化学免疫传感器,并应用于肝癌标志物甲胎蛋白(AFP)的检测。通过在丝网印刷电极(SPE)表面电沉积AuNPs提高电极的重现性,利用AuNPs的吸附作用固定AFP抗体,用于捕获样品中的待测AFP抗原,并进一步与固定了辣根过氧化物酶(HRP)标记检测抗体的纳米金免疫探针发生特异性结合,所形成的夹心免疫复合物可以催化底物得到响应电流。用扫描电镜(SEM)和微分脉冲伏安法(DPV)等技术研究电极组装过程以及电极的化学性质,讨论了影响免疫传感器性能的因素。在最优实验条件下,传感器的峰电流信号与AFP浓度在2.5~30ng/mL范围内呈良好的线性关系,检出限为0.16ng/mL。该传感器具有灵敏度高、成本低、仪器体积小的优点,具有较好的应用前景。  相似文献   

3.
《Electroanalysis》2017,29(6):1618-1625
An electrochemical sensor was developed based on gold nanoparticles incorporated in mesoporous MFI zeolite for the determination of purine bases. Au nanoparticles (AuNPs) were incorporated into the mesoporous MFI zeolite (AuNPs/m‐MFI) by post‐grafting reaction. The composite materials were characterized by transmission electron microscopy (TEM), X‐ray photoelectron spectroscopy (XPS) and electrochemical methods. Au nanoparticles with a size of 5‐20 nm are uniformly dispersed in the pores of mesoporous MFI zeolite. And the morphology of MFI zeolite can be perfectly kept after pore expansion and Au nanoparticles incorporation. The electrocatalytic oxidation of purine bases (guanine and adenine in DNA) is investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The surface‐confined Au nanoparticles provide the good catalytic activity for oxidation of purine bases. The simultaneous detection of guanine and adenine can be achieved at AuNPs/m‐MFI composites modified glassy carbon electrode (GCE). The electrochemical sensor based on AuNPs/m‐MFI exhibits wide linear range of 0.5–500 μM and 0.8–500 μM with detection limit of 0.25 and 0.29 μM for guanine and adenine, respectively. Moreover, the electrochemical sensor is applied to evaluation of guanine and adenine in herring sperm DNA samples with satisfactory results.  相似文献   

4.
This work designed a simple, sensitive, and low-cost immunosensor for the detection of protein marker by using a carbon sphere/gold nanoparticle (CNS/AuNP) composite as an electrochemical label. The nanoscale carbon spheres, prepared with a hydrothermal method by using glucose as raw material, were used to load AuNPs for labeling antibody by electrostatic interaction, which provided a feasible pathway for electron transfer due to the remarkable conductivity. The disposable immunosensor was constructed by coating a polyethylene glycol (PEG) film on a screen-printed carbon-working electrode and then immobilizing capture antibody on the film. With a sandwich-type immunoassay format, the analyte and then the CNS/AuNP-labeled antibody were successively bound to the immunosensor. The bound AuNPs were finally electro-oxidized in 0.1 M HCl to produce AuCl(4)(-) for differential pulse voltammetric (DPV) detection. The high-loading capability of AuNPs on CNS for the sandwich-type immunorecognition led to obvious signal amplification. By using human immunoglobulin?G (IgG) as model target, the DPV signal of AuNPs after electro-oxidized at optimal potential of +1.40?V for 40?s showed a wide linear dependence on the logarithm of target concentration ranging from 10?pg mL(-1) to 10?ng mL(-1). The detection limit was around 9?pg mL(-1). The immunosensor showed excellent analytical performance with cost effectivity, good fabrication reproducibility, and acceptable precision and accuracy, providing significant potential application in clinical analysis.  相似文献   

5.
Electrochemical detection of nitrite was achieved via electrodeposition of gold nanoparticles (AuNPs) onto glassy carbon electrodes, followed by 3‐mercaptopropionic acid (MPA) self‐assembly, enabling attachment of an iron(III) monoamino‐phthalocyanine (FeMAPc) catalyst via amide bond formation. The use of scanning electron microscopy, energy dispersive X‐ray spectroscopy and ultraviolet‐visible spectroscopy realised surface characterisation while cyclic voltammetry and electrochemical impedance spectroscopy techniques were applied for electrochemical interrogation. The electrochemical behaviour of nitrite at the bare (GCE), AuNPs/GCE, FeMAPc/GCE and FeMAPc‐MPA/AuNPs/GCE was further scrutinised using differential pulse voltammetry in phosphate buffer solution (0.1 M PBS, pH 5.8). Overall the FeMAPc‐MPA/AuNPs/GCE resulted in sensitivity 14.5 nA/µM, which was double that of AuNPs/GCE, 2.4 times FeMAPc/GCE and 3.5 times the response at a bare GCE, with linear range 1.9 µM–2.04 mM (PBS, pH 5.8) and LOD 0.21 µM. An interference study revealed that the proposed sensor (FeMAPc‐MPA/AuNPs/GCE) exhibited a selective response in the presence of interfering anions and the analytical capability of the sensor was demonstrated via nitrite ion determination in real water samples.  相似文献   

6.
In this study, a nanocomposite of 3, 4, 9, 10‐perylenetetracarboxylic acid and L‐cysteine (PTCA‐Cys) with satisfactory water‐solubility and film‐forming ability was prepared and worked as substrate for modifying the glassy carbon electrode. Then, gold nanoparticles (AuNPs) were immobilized to achieve a PTCA‐Cys‐AuNPs modified electrode which provided more reaction positions on the sensor. Scanning electron microscopy, transmission electron microscopy, cyclic voltammetry and different pulse voltammetry were employed to characterize the assembly process of the sensor. The constructed sensor displayed desirable sensitivity, selectivity and stability towards the simultaneous detection of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Under the optimal experimental conditions, the oxidation peaks of AA, DA and UA appeared at 64, 240 and 376 mV, respectively. The corresponding linear response ranges were 3.2–435, 0.04–100 and 0.80–297 μM, and the detection limits were 1.1, 0.010 and 0.27 μM (S/N=3), respectively.  相似文献   

7.
《Electroanalysis》2018,30(3):402-414
A sensitive electrochemical immunosensor for Hepatitis B virus surface antigen (HBsAg) detection was fabricated based on hemin/G‐quadruplex interlaced onto Fe3O4‐AuNPs or hemin ‐amino‐reduced graphene oxide nanocomposite (H‐amino‐rGO‐Au). G‐quadruplex DNAzyme, which is composed of hemin and guanine‐rich nucleic acid, is an effective signal amplified tool for its outstanding peroxidase activity and Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites with quasi‐enzyme activity provide appropriate support for the immobilization of hemin/G‐quadruplex. The target protein was sandwiched between the primary antibody immobilized on the GO and secondary antibody immobilized on the Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites and glutaraldehyde was used as linking agent for the immobilization of primary antibody on the surface of GO. Both Fe3O4‐AuNPs and H‐amino‐rGO‐Au nanocomposite and also hemin/G‐quadruplex can cooperate the electrocatalytic reduction of H2O2 in the presence of methylene blue as mediator. The proposed immunosensor has a wide linear dynamic range of 0.1 pg/ml to 300 pg/ml with a detection limit of 60 fg/ml when Fe3O4‐AuNPs was used for immobilization of hemin/G‐quadruplex, while the dynamic range and DL were 0. 1–1000 pg/mL and 10 fg/mL, respectively in the presence of H‐amino‐rGO‐ Au nanocomposite as platform for immobilizing of hemin/G‐quadruplex. The proposed immunosensor was also used for analysis of HBsAg in spiked human serum samples with satisfactory results.  相似文献   

8.
Enzyme‐based electrochemical biosensors with sufficient sensing specificity are useful analytical tools for detection of biologically important substances in complicated systems. Here, we present the design of a nano‐hybrid biosensor for the specific and sensitive detection of methyl parathion (MP). The nano‐hybrid sensing film was prepared via the formation of Au nanoparticals (AuNPs) on silica nanoparticles (SiNPs), mixing with multiwall carbon nanotube (MWNTs) and subsequent immobilization of methyl parathion degrading enzyme (MPD). The fabrication procedure was characterized by scanning electron images, linear scan voltammetry and electrochemical impedance spectroscopy. The combined MPD exhibited high affinity to it substrate and thus a selective, sensitive, fast and cheap method for determination of MP, quantitatively was proposed. A significant synergistic effect of nano‐hybrid on the biosensor performance was observed in biosensing MP. The square wave voltammetric responses displayed well defined peaks, linearly proportional to the concentration of MP in the range from 0.001 to 5.0 μg/mL with a detection limit of 0.3 ng/mL. The proposed biosensor also showed good precision and reproducibility, acceptable stability and accuracy in garlic samples analysis. It provided a platform for the simple and fast construction of biosensors with good performance for the determination of enzyme‐specific electroactive species.  相似文献   

9.
In this study, a novel non‐enzymatic hydrogen peroxide (H2O2) sensor was fabricated based on gold nanoparticles/carbon nanotube/self‐doped polyaniline (AuNPs/CNTs/SPAN) hollow spheres modified glassy carbon electrode (GCE). SPAN was in‐site polymerized on the surface of SiO2 template, then AuNPs and CNTs were decorated by electrostatic absorption via poly(diallyldimethylammonium chloride). After the SiO2 cores were removed, hollow AuNPs/CNTs/SPAN spheres were obtained and characterized by transmission electron microscopy (TEM), field‐emission scanning electron microscopy (FESEM) and Fourier transform infrared spectroscopy (FTIR). The electrochemical catalytic performance of the hollow AuNPs/CNTs/SPAN/GCE for H2O2 detection was evaluated by cyclic voltammetry (CV) and chronoamperometry. Using chronoamperometric method at a constant potential of ?0.1 V (vs. SCE), the H2O2 sensor displays two linear ranges: one from 5 µM to 0.225 mM with a sensitivity of 499.82 µA mM?1 cm?2; another from 0.225 mM to 8.825 mM with a sensitivity of 152.29 µA mM?1 cm?2. The detection limit was estimated as 0.4 µM (signal‐to‐noise ratio of 3). The hollow AuNPs/CNTs/SPAN/GCE also demonstrated excellent stability and selectivity against interferences from other electroactive species. The sensor was further applied to determine H2O2 in disinfectant real samples.  相似文献   

10.
《Electroanalysis》2018,30(8):1757-1766
Electrochemical sensors provide a selective, sensitive and an easy approach to detect hazardous substances such as hydrazine. Herein, we investigate a facile route for the fabrication of a nanostructured composite based on Au nanoparticles (AuNPs) decorated graphene and present its sensing performance towards hydrazine. Our strategy involves electrophoretic deposition (EPD) of graphene oxide (GO) on Au substrate to obtain a uniform layer EPD‐GO, followed by electrochemical reduction of GO to yield high quality graphene ERGO and electrodeposition of monodispersed AuNPs on ERGO (AuNPs/ERGO/Au). The modified AuNPs/ERGO/Au electrode was characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT‐IR) techniques. The sensor exhibited an improved catalytic activity with a peak potential of +87 mV (vs. Ag/AgCl) for hydrazine oxidation. The high performance of this hybrid electrode is due to the presence of a synergistic effect between AuNPs and ERGO at their interface. Insights into the mechanism and kinetics of hydrazine oxidation are withdrawn from varying the voltage scan rate as the reaction is fully irreversible and diffusion‐controlled. The proposed hydrazine sensor showed suitability for nanomolar detection (detection limit of 74 nM), high selectivity in the presence of common ions and efficiency for application in water samples.  相似文献   

11.
将金纳米粒子(AuNPs)标记的大肠杆菌O157∶H7(E.coli O157∶H7)的多克隆抗体(PAb)作为二抗,采用氨基偶联法将PAb固定在传感器表面作为一抗,通过三明治方法用双通道表面等离子体子共振(SPR)传感器对E.coli O157∶H7进行检测,并与SPR直接法检测进行了比较.结果表明,直接法的检出限为103cfu/mL,线性范围为103~109cfu/mL;AuNPs增强三明治法的检出限为10 cfu/mL,线性范围为10~1010cfu/mL,灵敏度比直接法提高了100倍,且具有更宽的检测范围.本方法不仅检测时间短,而且具有良好的选择性和重现性.  相似文献   

12.
《Electroanalysis》2017,29(9):2098-2105
An ultrasensitive electrochemiluminescence (ECL) immunosensor for the detection of tetrodotoxin (TTX) is proposed, which are composed of the branched poly‐(ethylenimine) (BPEI) functionalized graphene (BGNs)/Fe3O4‐Au magnetic capture probes and luminol‐capped gold nanocomposites (luminol‐AuNPs) as the signal tag. Herein, a typical sandwich immunecomplex was constructed on the glassy carbon electrode. The BGNs/Fe3O4‐Au hybrids could efficiently conjugate primary antibody via the Au−S chemical bonds or Au−N chemical bonds and rapidly separate under external magnetic field. The introduction of BPEI to GO could enhance the luminol‐ECL intensity. Meanwhile, the multifunctional nanocomposites have been proved with good water‐solubility, excellent electron transfer, outstanding stability, etc. The luminescent luminol‐AuNPs, a high efficient electrochemiluminescence marker, can be assembled on the second antibody, which can produce the ECL signal to achieve the determination of TTX. This proposed ECL immunosensor with a linear range from 0.01–100 ng/mL can be applied in the detection of TTX in real samples with satisfactory results.  相似文献   

13.
A layered nanohybrid comprising of multi walled carbon nanotubes(MWCNT)‐gold nanoparticles (AuNPs) has been designed as a matrix for the development of Au dendritic nanostructures (AuDN) with enhanced catalytic activity. The developed sensor matrix was thoroughly characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), and energy dispersive X‐ray spectroscopy (EDX). The developed sensor probe MWCNT‐AuNPs/AuDN over glassy carbon electrode (GCE) was used for the label free detection of acetaminophen (AP), a commonly used drug associated with hepatotoxicity when overdosed, as a model molecule. The final sensor probe was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), linear sweep voltammetry (LSV), and differential pulse voltammetry (DPV). The sensor shows excellent analytical performances with a linear dynamic range (LDR) of 100 to 7500 nM, and a low limit of detection (LOD) of 2.12 (±0.03) nM, which is better than recently reported AP sensors. The practical application / clinical possibilities of the final sensor were evaluated by real sample analysis in human urine by spike and recovery method, where the AP recoveries were found in between 92 % to 96 %. The sensor probe shows negligible response towards co‐existing interfering molecules like glucose, urea, uric acid and various amino acids, which are commonly found in real samples (p<0.001, n=3). The shelf life of the sensor probe was evaluated and found to be stable for 8 weeks. The fabricated sensor probe using MWCNT‐AuNPs/AuDN is easy to fabricate, simple, robust, and able to detect AP in urine with high recoveries shows its possibilities to be used in clinical settings.  相似文献   

14.
The measurement of biomarkers in bodily fluids is extremely important for diagnosing disease, monitoring disease progression, and evaluating treatment efficacy. In this paper, we present a highly sensitive and compatible gold nanoparticle (AuNP)‐based, two‐step signal amplification system for biomarker detection. First, AuNPs were coated onto the surfaces of 96‐well plates to generate rough surfaces, which enable immobilization of many more capture antibodies than a smooth substrate. As a result, detection sensitivity was enhanced significantly. Second, the horseradish peroxidase (HRP)‐conjugated detection antibodies were labeled on large‐size AuNPs, which increase the localized amounts of HRP and thus further lower the detection limit. Based on the consecutive signal amplification system, a high‐sensitivity assay was achieved, with a LOD of 0.07 ng/mL for prostate‐specific antigen (PSA). This assay was allowed to detect the PSA levels in clinical samples without changing the current standard immunoassay setups, showing great potential in many settings where immunoassays are needed.  相似文献   

15.
Both unmodified gold nanoparticles (AuNPs) and p‐nitrobenzenesulfonic (p‐NBS) grafted silver nanoparticles (AgNPs) were prepared by chemical synthesis, respectively. They could be used for visual detection via the interaction with the twelve amide compounds including melamine. These color changes could be seen with the naked eye directly and monitored by ultraviolet visible (UV‐Vis) absorbance spectra. The recognition mechanism for both nanoparticles was comparatively investigated by the addition of glutathione (GSH) in the presence of melamine, respectively. The triple hydrogen bonding recognition and the attractive van der Waals interactions between melamine (0.5 mg/L) and AuNPs were responsible for the color change during its aggregation (red‐to‐purple or blue), whilst the electron donor‐acceptor interaction between melamine (0.2 mg/L) and p‐NBS modified on the surface of AgNPs resulted in the color changes (yellow‐to‐grey or dark green).  相似文献   

16.
基于AuNPs/PDDA-GO纳米复合物制备了一种新型电化学免疫传感器, 并将其用于SirT1的检测. 首先, 在电极表面修饰复合材料AuNPs/PDDA-GO, 然后将目标蛋白SirT1固定到修饰了AuNPs/PDDA-GO的电极表面, 再通过特异性免疫反应结合一抗(Ab1)和辣根过氧化酶标记的二抗分子(HRP-Ab2), 最后用示差脉冲伏安法检测电流信号, 实现了对SirT1蛋白水平的测定. 在优化的实验条件下, SirT1蛋白的浓度在0.1~100 ng/mL范围内与响应电流呈良好线性关系, 检出限为0.029 ng/mL.  相似文献   

17.
Screening and early diagnosis are crucial to increase the success of cancer patients’ treatments and improve the survival rate. To contribute to this success, distinct electrochemical immunosensing platforms were developed for the analysis of the ExtraCellular Domain of the Human Epidermal growth factor Receptor 2 (HER2‐ECD) through sandwich assays on nanomaterial‐modified screen‐printed carbon electrodes (SPCEs). The most promising platforms showed to be SPCEs modified with (i) gold nanoparticles (AuNPs) and (ii) multiwalled carbon nanotubes combined with AuNPs. The antibody‐antigen interaction was detected using a secondary antibody labelled with alkaline phosphatase and 3‐indoxyl phosphate and silver ions as the enzymatic substrate. The electrochemical signal of the enzymatically generated metallic silver was recorded by linear sweep voltammetry. Under the optimized conditions, linear calibration plots were obtained between 7.5 and 50 ng/mL and the total assay time was 2 h 20 min, achieving LODs of 0.16 ng/mL (SPCE‐MWCNT/AuNP) and 8.5 ng/mL (SPCE‐AuNP), which are well below the established cut‐off value of 15 ng/mL for this cancer biomarker.  相似文献   

18.
Feng Q  Li H  Zhang Z  Lin JM 《The Analyst》2011,136(10):2156-2160
Gold nanoparticles (AuNPs) of different sizes were synthesized by the citrate reduction method. It was found that AuNPs could enhance the chemiluminescence (CL) of the luminal-NaOH system and 2,4-dichlorophenol (2,4-DCP) could inhibit AuNPs-luminal-NaOH CL signals in alkaline solution. CL spectra, UV-visible spectra, and transmission electron microscopy (TEM) were used to investigate the CL mechanism. On the basis of the inhibition, a flow-injection CL method has been established for determination of 2,4-DCP in water samples. Under the optimized conditions, the linear range for determination of the 2,4-DCP was 0.1 × 10(-6) to 20 × 10(-6) g mL(-1), LOD (limit of detection, S/N = 3) was 1.36 × 10(-8) g mL(-1), with RSD of 1.8% (n = 11). This method has been successfully used for analysis of 2,4-DCP in environmental water samples.  相似文献   

19.
《Electroanalysis》2018,30(1):194-203
Glassy carbon electrode (GCE) modified with L‐cysteine and gold nanoparticles‐reduced graphene oxide (AuNPs‐RGO) composite was fabricated as a novel electrochemical sensor for the determination of Cu2+. The AuNPs‐RGO composite was formed on GCE surface by electrodeposition. The L‐cysteine was decorated on AuNPs by self‐assembly. Physicochemical and electrochemical properties of L‐cysteine/AuNPs‐RGO/GCE were characterized by scanning electron microscopy, atomic force microscopy, energy dispersive spectroscopy, Raman spectroscopy, X‐ray diffraction, cyclic voltammetry and adsorptive stripping voltammetry. The results validated that the prepared electrode had many attractive features, such as large electroactive area, good electrical conductivity and high sensitivity. Experimental conditions, including electrodeposition cycle, self‐assembly time, electrolyte pH and preconcentration time were studied and optimized. Stripping signals obtained from L‐cysteine/AuNPs‐RGO/GCE exhibited good linear relationship with Cu2+ concentrations in the range from 2 to 60 μg L−1, with a detection limit of 0.037 μg L−1. Finally, the prepared electrode was applied for the determination of Cu2+ in soil samples, and the results were in agreement with those obtained by inductively coupled plasma mass spectrometry.  相似文献   

20.
A new sensitive fluorometric assay method for acetylcholinesterase (AChE) and its inhibitor was developed using a fluorescent dye, nile red (NR). Due to the fluorescence resonance energy transfer between the NR and the gold nanoparticle (AuNPs), the fluorescence was quenched. AChE can break down acetylthiocholine to produce a thiol‐bearing compound, thiocholine. In the presence of thiocholine, the nile red is replaced from the AuNPs surfaces and simultaneously transformed to a derivative of nile red. The fluorescence intensity of the derivative is much stronger than that of the native nile red with the same concentration and its maximum emission wavelength has a blue shift so that the sensor achieves a good signal‐to‐background ratio. In addition, when organophosphate pesticide (OPs) exists, the activity of AChE can be inhibited, the generation of thiocholine will be prevented and no fluorescence enhancement occurs. The results show that the method is sensitive to AChE and paraoxon with the detection limits of 0.2 mU/mL and 0.05 ng/mL, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号