首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 751 毫秒
1.
A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min?1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg?1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg?1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.  相似文献   

2.
The unique features of nanostructured polypyrrole, conductivity enhancement effect of silver nanoparticles and high polar adsorptivity of polyethylene glycol were merged into polypyrrole/silver/polyethylene glycol (PPy/Ag/PEG) nanocomposite. It was synthesized and simultaneously coated on the surface of a stainless-steel fiber using an amended electropolymerization procedure. Before coating, the fiber substrate was made porous and sticky by allocating platinum dots on the surface of the stainless-steel fiber using the electrophoretic method. The prepared fiber was applied for the extraction of carvacrol and thymol (the most important antioxidants in medicinal plants) through an electroenhanced direct-immersion solid-phase microextraction (EE-DI-SPME) sampling strategy, followed by GC-FID quantification. To achieve the best efficiency, the effectual experimental variables including pH of sample solution, applied voltage, extraction temperature and time, stirring rate, and ionic strength were investigated. Under the optimal experimental conditions, the calibration curves were linear over the range of 0.5–30 µg mL?1 for thymol and 0.01–30 µg mL?1 for carvacrol. The detection limits (3Sb) and relative standard deviation (RSD%, n?=?6) were obtained to be 0.15, 0.003 µg mL?1 and 10.2, 8.7% for thymol and carvacrol, respectively. The results demonstrated the priority of the proposed fiber compared with polypyrrole and polyacrylate fibers, in terms of extraction efficiency, durability and stability. The developed method was successfully employed for the analysis of thymol and carvacrol in medicinal plants.  相似文献   

3.
《Analytical letters》2012,45(8):1434-1447
The use of disposable pipette extraction was examined for the simple and rapid determination of seven high explosives (cyclotrimethyl-enetrinitramine, cyclotetramethyl-enetetranitramine, 2,4,6-trinitrophenyl-methylnitramine, 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, nitroglycerin, and pentaerythritol tetranitrate) in water. The current study involved the determination of slightly polar and nonpolar explosives in water with a reversed phase sorbent followed by high performance liquid chromatography. The method was based on a styrene divinylbenzene sorbent loosely placed inside a 5-mL pipette tip. Water samples were drawn into the tip and mixed with the sorbent. Air bubbles were also drawn through the tip following sample solution to enhance mixing. Because disposable pipette extraction uses small amounts of sorbent, minimal solvent is required to elute analytes and solvent evaporation is not necessary. The method provided rapid sample preparation, and required less than five minutes to extract 1.0 mL of water sample in the current study. Matrix-matched calibration was performed, and the limits of detection (LOD) were determined to be below 0.1 µg mL?1 for all targeted explosives in water with an enrichment factor of two. Coefficients of determination (r2) were greater than 0.9990 for all studied explosives, and the recoveries ranged from 69.76% to 87.51%, 83.77% to 91.25%, and 83.62% to 98.99% for samples spiked at 0.25 µg mL?1, 1.0 µg mL?1, and 5.0 µg mL?1, respectively. The relative standard deviations of recoveries at all spiked levels were below 8.97%. These results indicate that the disposable pipette extraction method provided good accuracy and precision for the determination of explosives in water.  相似文献   

4.
A new method for simultaneous determination of seven kinds of phenylurea herbicides (PUHs) in solid foodstuffs was established based on matrix solid phase dispersion (MSPD)–RP-LC. The procedure of MSPD is simple and not time-consuming. C18-bonded silica and anhydrous alumina were, respectively, used as dispersion sorbent and purificant, and dichloromethane as extraction reagent. Under the optimum conditions, seven kinds of herbicides were separated completely within 30 min, response was a linear function of concentration over the range 2.5–500 μg L?1 with good correlation coefficients (>0.99) and lower detection limits (0.25 and 0.5 μg L?1). Intra-day and inter-day precision of the peak areas for seven PUHs were less than 3.7 and 5.3%. The new method was used to detect seven PUHs in four kinds of solid foodstuffs with average recoveries range from 73.1 to 101%.  相似文献   

5.

A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min−1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg−1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg−1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.

  相似文献   

6.
A new, rapid, selective, cheap and simple RP-LC method has been developed and validated for the simultaneous determination of clobetasol propionate and calcipotriol mixtures in bulk drugs (raw materials) and in a novel-fixed dose emulgel formulation. Separation was carried out using a NovaPak C18 column with methanol:water (74:26 v/v) as mobile phase for isocratic elution at a flow rate of 1.0 mL min?1. The column temperature was set at 25 °C. Calibration curves were established ranging between 0.5 and 20 μg mL?1 and 0.5 and 10 μg mL?1 for clobetasol propionate and calcipotriol, respectively. Limit of detection and limit of quantification values of the method was found as 0.16 and 0.48 μg mL?1 for clobetasol propionate and 0.10 and 0.30 μg mL?1 for calcipotriol, respectively. The method was validated in accordance with ICH guidelines and obtained results proved that the proposed method was precise, accurate, selective and sensitive for the simultaneous analysis of clobetasol propionate and calcipotriol. The proposed method can be easily applied for the simultaneous determination of clobetasol propionate and calcipotriol in prepared emulgel formulations. The obtained validation results showed that the RP-LC method is suitable for routine quantification of clobetasol propionate and calcipotriol in emulgel formulations with high precision and accuracy.  相似文献   

7.
Dithiocarbamate modified polyurethane foam (DTC-PUF) was synthesized as a new solid-phase extraction sorbent for the preconcentration and determination of Fe(II), Mn(II) and Cu(II) in environmental samples using flame atomic absorption spectrometry. Maximum extraction of the elements was achieved at pH 5–7 and flow rate 3 mL min?1. Quantitative desorption was achieved by 10 mL from 1.0 mol L?1 HCl solution. The capacity of the sorbent was 149.2 ± 0.5, 237.5 ± 0.2, 200.2 ± 0.1 μg g?1 and the limit of detection was of 0.015, 0.015 and 0.012 μg mL?1for Fe(II), Mn(II) and Cu(II), respectively. A preconcentration factor of 100 was obtained for all elements. The developed method was successfully applied to the determination of the tested elements in water (tap and lake) and plant (spinach and parsley leaves) samples and showed good recovery values from 98 to 111% with corresponding RSD values ranged from 0.6 to 8.6%.  相似文献   

8.
A sensitive matrix solid-phase dispersion (MSPD)/gas chromatography-electron capture detector (GC-ECD) method was developed to determine cypermethrin residues in three tissues (muscle, liver, and gill) of crucian carp. Cypermethrin was simultaneously extracted by MSPD and determined by GC-ECD. The main parameters affecting extraction yield and selectivity, such as the type of solid adsorbent material, choice of elution solvents and their volume, were investigated to obtain interference-free extracts and quantitative cypermethrin recovery. Fortified recoveries in muscle, liver, and gill samples ranged from 84.9% to 106.1%, and relative standard deviations were <8% with fortification levels of 0.05–1 mg kg?1. Detection limits were 1.4–2.1 μg kg?1, and quantitation limits were 5.8–7.8 μg kg?1. The proposed method was successfully applied to determination of cypermethrin in fish tissue samples.  相似文献   

9.
A novel analytical technique termed ultrasonic-assisted drop-to-drop solvent microextraction (USA-DDSME) in a capillary tube was developed to determine trace benzene, toluene, xylene in one drop of a water sample, which was combined with gas chromatography–flame ionization detection (GC–FID). The advantages of this method are rapidity, convenience, ease of operation, simplicity of the device, and extremely little solvent and sample consumption. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, the volume of sample, extraction time and effect of salt concentration were optimized. The best optimum parameters for extraction were achieved with 3 μL of extraction solvent. Chloroform was divided into four equal divisions in 20 μL water sample (without salt addition) in a capillary tube and ultrasonicated for 10 min, centrifugated at 2,500 rpm for 5 min to let the extraction solvent settle at the bottom of the capillary tube, then 1 μL of the separated extraction solvent was injected into the GC–FID for analysis. Linearity of the method was determined by analyzing spiked water samples over a concentration range of 0.1–50 μg mL?1. Correspondingly, the LOD values were 0.01 μg mL?1. All calibration curves were found to have good linearity with correlation coefficients (r 2) > 0.995. The precision (RSD) of the system, measured by six repeated determinations of the analytes at 1 μg mL?1 were in the range of 1.6–3.5%.  相似文献   

10.
A GC-MS method with HP-5MS capillary column was developed for the simultaneous determination of underivatized flunitrazepam, clonazepam, alprazolam, diazepam and ketamine from drinks by extraction with chloroform: isopropanol 1:1 (v/v). All linearity ranges were between 50 and 1,000 μg mL?1 for all compounds both in beer and in peach juice. Limit of detection was between 1.3 and 34.2 μg mL?1, limit of quantification was between 3.9 and 103.8 μg mL?1, the range of recoveries was 73.0 and 112.6% for all drugs in both beverages. The reported method was sensitive, rapid, and suitable for the analysis of the spiked drinks as evidence of sexual assault and robbery phenomena.  相似文献   

11.
An organo-nanoclay is used as a new, easily accessible, and stable solid sorbent for the preconcentration of trace amounts of rhodium ions from aqueous solution, this followed by its determination by flame atomic absorption spectrometry (FAAS). Rh(III) ion was first complexed with 2,3,5,6-tetra(2-pyridyl) pyrazine (TPPZ) at pH values between 3.0 and 4.7, and then the complex was then adsorbed onto the nanoclay. The rhodium ions were eluted from the sorbent with HCl. The rhodium in the effluent was determined by FAAS. The linear analytical range is between 0.14 ng mL?1 and 20.0 μg mL?1 in the initial solution, the relative standard deviation at 2.0 μg mL?1 of rhodium is 2.6% (n?=?8), the detection limit is 0.03 ng mL?1, and the preconcentration factor is 140. Experimental parameters including the pH, eluent type, interference by other ions and breakthrough volume were optimized. The method was applied to the determination of rhodium in water, road dust and synthetic samples.  相似文献   

12.
Guanidino compounds guanidine, methylguanidine, guanidinoacetic acid, guanidinobutyric acid, guanidinopropionic acid, and guanidinosuccinic acid after derivatization with hexafluoroacetylacetone and ethyl chloroformate at pH 9 in aqueous phase, eluted, and separated from gas chromatographic column HP-5 (30 m × 0.32 mm id) with film thickness of 0.25 μm at an initial column temperature 90 °C for 2 min, followed by heating rate of 10 °C min?1 up to 220 °C with nitrogen flow rate of 1 mL min?1. The detection was by flame ionization detector. The linear calibration ranges of each of guanidino compounds were obtained within 1–10 μg mL?1, and the limit of detection was within 0.014–0.19 μg mL?1. The derivatization and gas chromatography elution and separation were repeatable in terms of retention time and peak height/peak area with relative standard deviation (RSD) (n = 4) within 1.7–2.9 % and 1.4–2.8 %, respectively. The method was applied for the determination of guanidino compounds from deproteinized serum of uremic patients and healthy volunteers, and was found in the range below the limit of quantitation (BLOQ) to 1.25 μg mL?1 with RSD within 1.4–3.6 %, and BLOQ to 0.4 μg mL?1 with RSD 1.3–3.4 %, respectively. A number of pharmaceutical additives did not effect the determination with RSD within ±3.1 %.  相似文献   

13.
Bengi Uslu  Tugba Özden 《Chromatographia》2013,76(21-22):1487-1494
High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL?1 of ENL, 0.260–399 μg mL?1 of HCZ for HPLC system and 0.270–399 μg mL?1 of ENL and 0.065–249 μg mL?1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL?1 and 31.477 ng mL?1 for HCZ, 2.804 ng mL?1 for ENL and 2.943 ng mL?1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.  相似文献   

14.
A simple, sensitive, fast and efficient method based on dispersive liquid–liquid microextraction (DLLME) followed by ion mobility spectrometry (IMS) has been proposed for preconcentration and trace detection of carbamazepine (CBZ) in formulation samples. In this method, 1 mL of methanol (disperser solvent) containing 80 μL of chloroform (extraction solvent) was rapidly injected by a syringe into a sample. After 5 min centrifugation, the preconcentrated carbamazepine in the organic phase was determined by IMS. Development of DLLME procedure includes optimization of parameters influencing the extraction efficiencies such as kind and volume of extraction solvent, disperser solvent and salt addition, centrifugation time and pH of the sample solution. The proposed method presented good linearity in the range of 0.05–10 μg mL?1 and the detection limit was 0.025 μg mL?1. The repeatability of the method expressed as relative standard deviation was 6 % (n = 5). This method has been applied to the analysis of carbamazepine formulation samples with satisfactory relative recoveries ≤75 %.  相似文献   

15.
In this work, a novel method based on ultrasonic-assisted nebulization extraction coupled with solid phase extraction (UANE-SPE) and determined by high performance liquid chromatography was developed for the determination of triterpenoids in root of Euphorbia pekinensis Rupr. The experimental conditions for the UANE-SPE, such as type of extraction solvent, sample amount, type and amount of sorbent, extraction time and volume of the elution solvent, were examined and optimized. The method was successfully applied to determine euphol and tirucallol in the dried root of E. pekinensis Rupr. The recoveries of the analytes were in the range of 89.1–102.0 %. The limits of detection were 12 μg g?1 for tirucallol and 10 μg g?1 for euphol. The extraction yields obtained by the proposed method are higher than those obtained by the conventional extraction methods, such as reflux and ultrasonic-assisted extraction. Compared with the traditional methods, the proposed method can reduce the consumption of the labor, shorten the sample preparation time and increase the efficiencies in the extraction of active constituents from plant materials.  相似文献   

16.
Mercury exists in two forms in environment, inorganic salts and organic compounds. Determination of mercury is very important, due to its health effects. In the present research, diphenylation of mercury using phenylboronic acid as a derivatization reagent was used for the determination of Hg(II) in real water samples. A simple, rapid and cheap method named dispersive liquid–liquid microextraction was used for the extraction of analyte under the following conditions: extraction solvent 16 μL of carbon tetrachloride, disperser solvent 1 mL of ethanol and sample volume 5 mL. Under the optimal conditions, the enrichment factor for diphenylmercury was 931 and the limit of detection calculated on the basis of five replicates was 0.004 μg mL?1. The repeatability of the method expresses as relative standard deviation was 5.1 (n = 6). The linear range was between 0.01 and 10 μg mL?1. The performance of the proposed technique was evaluated for the determination of mercury in different environmental water samples.  相似文献   

17.
Solid-phase extraction followed by dispersive liquid–liquid microextraction (SPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating benzaldehyde, a toxic oxidation product of the widely used preservative and co-solvent benzyl alcohol, in injectable formulation solutions. SPE of benzaldehyde from samples was carried out using C18 sorbent. After the elution of benzaldehyde from the sorbent by using acetonitrile, DLLME technique was performed on the obtained solution. Benzaldehyde was preconcentrated by using DLLME technique. Thus, 1.5 mL acetonitrile extract (disperser solvent) and 55.0 µL 1,2-dichloroethane (extraction solvent) were added to 5 mL ultra pure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limit (LOD) of benzaldehyde calculated as three times the signal-to-noise ratio (S/N) was 0.08 µg L?1. The relative standard deviation (RSD) for four replicates was 5.8 %. The calibration graph was linear within the concentration range of 0.5–500 µg L?1 for benzaldehyde. The proposed method has been successfully applied to the analysis of the benzaldehyde in injectable formulation solutions (diclofenac, vitamin B-complex and voltaren) and the relative recoveries were between 88 and 92 % and show that matrix has a negligible effect on the performance of the proposed method.  相似文献   

18.
A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL?1 for ibuprofen, 0.001–1.0 μg mL?1 for naproxen, and 0.01–10.0 μg mL?1 for fenbufen. The limits of detection were 0.5 ng mL?1 for ibuprofen, 0.05 ng mL?1 for naproxen and 0.5 ng mL?1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.  相似文献   

19.
A novel, rapid and specific ultra performance liquid chromatography-photo diode array detection method was developed for the simultaneous determination of 2,3,5,4′-tetrahydroxystilbene-2-O-β-d-glucoside (TSG), emodin-8-O-β-d-glucoside (EMG), emodin (EM) and physcion (PS). The chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm i.d., 1.7 μm). The mobile phase was a mixture of 0.3% acetic acid–water and 0.3% acetic acid–acetonitrile employing gradient elution at the flow rate of 0.4 mL min?1. The four compounds behaved linearly in the concentration range between 60.80–3040.00 μg mL?1 (TSG), 0.50–25.00 μg mL?1 (EMG), 2.16–108.00 μg mL?1 (EM) and 1.56–78.00 μg mL?1 (PS), respectively with correlation coefficients >0.999. The precision of the method were below 5% RSD. Recoveries of the four compounds ranged from 95.71 to 102.97%, with RSD values less than 2%.  相似文献   

20.
A sensitive, selective and accurate ultra performance liquid chromatographic method has been developed and validated for the simultaneous determination of bisoprolol fumarate and hydrochlorothiazide in their combined dosage forms and as well as in spiked human urine samples. The separation was achieved on an Acquity UPLC BEH C18 1.7 μm (2.1 × 50 mm) column, at 40 °C with mobile phase consisting of acetonitrile:phosphate buffer (20 mM) at pH 3.0 with a gradient elution at 225 nm. Bisoprolol fumarate and hydrochlorothiazide were well separated in <1.5 min with good resolution and without any tailing and interference of excipients. The method was fully validated according to ICH guidelines in terms of accuracy, precision, linearity and specificity. A linear response was observed over the concentration range 0.5–150 μg mL?1 for hydrochlorothiazide and 0.5–250 μg mL?1 for bisoprolol fumarate. Limit of detection and limit of quantitation for hydrochlorothiazide were calculated as 0.01 and 0.03 μg mL?1, respectively, and for bisoprolol fumarate were 0.07 and 0.21 μg mL?1, respectively. Moreover, bisoprolol fumarate and hydrochlorothiazide were subjected to degradation conditions such as hydrolytic, oxidative and thermal stress conditions to evaluate the ability of the proposed method for the separation of bisoprolol fumarate and hydrochlorothiazide from their degradation compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号