首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 86 毫秒
1.
A pipette tip multiwalled-carbon nanotube solid-phase extraction (PT-MWCNTs-SPE) coupled with flame atomic absorption spectrometry (FAAS) was developed for extraction and determination of lead in hair samples. In this study, PT-MWCNTs-SPE cartridge, assembled by packing MWCNTs as a sorbent into a 100-μL pipette tip. Taguchi’s method (L9 orthogonal array (OA)) as a statistical design of experiments was employed to optimise the factors and experiments that affected on the recovery of Pb(II). Under the optimum conditions, four parameters such as pH (P), volume of ligand (AL), sorbent amount (SA) and eluent concentrations of HNO3 (EC) were chosen as important affecting parameters. The limit of detection (LOD) of this method was 0.86 µg L?1 with relative standard deviations (RSD) ≤3% for Pb(II). Afterwards, the accuracy of proposed method was evaluated by TMDA 53.3 fortified water and NCS ZC 81002b human hair certified reference materials. The procedure was applied to lead contents of water and hair samples.  相似文献   

2.
《Analytical letters》2012,45(6):1052-1062
A new simplified extraction of gold(III) using a room-temperature ionic liquid prior to determination by flame atomic absorption spectrometry has been developed. The extraction method uses 1-butyl-3-methylimidazolium hexafluorophosphate without a chelating agent. The parameters of the extraction system were investigated in detail. Under the optimized conditions, a linear range of 0.19 to 38.20 µg · mL?1, a limit of detection of 0.072 µg · mL?1, an enrichment factor of 10.0, and an extraction capacity of 6.6 mg · g?1 were obtained. The extraction mechanism and the selectivity of 1-butyl-3-methylimidazolium hexafluorophosphate for gold(III) were also investigated. The method was applied for the determination of gold(III) in water samples with satisfactory results.  相似文献   

3.
《Analytical letters》2012,45(13):2075-2088
For the first time, a simple method for magnetic stirring-assisted dispersive suspended microextraction has been developed for the determination of three fungicides (azoxystrobin, diethofencarb, and pyrimethanil) in water and wine samples. The method is based on the solidification of a floating organic droplet coupled with high performance liquid chromatography. In the proposed method, the low toxicity solvent 1-dodecanol was used as the extractant. Both the extraction and phase separation process were performed with magnetic stirring. No centrifugation step was involved. After separating the two phases, the extraction solvent droplet was easily collected through solidification at lower temperature. Important parameters such as the kind and volume of organic extraction solvent, extraction and restoration speed, extraction and restoration time, and salt concentration were optimized. Under the optimal conditions, the limits of detection for the analytes varied from 0.14 to 0.26 µg L?1. The enrichment factors ranged from 125–200. The linearity ranges were 1–2000 µg L?1, yielding correlation coefficients (r) higher than 0.9990. The relative standard deviation (n = 6) at two spiked level of 0.2 µg mL?1 and 4 µg L?1 varied between 2.2% and 7.8%. Finally, the developed technique was successfully applied to determine target fungicides in real water and wine samples, where the obtained recoveries ranged from 83.8–105.3%  相似文献   

4.
《Analytical letters》2012,45(1):207-220
Abstract

A method for determination of selected triazines in waters was developed. The method includes off‐line solid‐phase extraction of triazines on the polymeric sorbent, high‐pressure liquid chromatographic separation, and determination with tandem mass spectrometer. The linearity extended from 0.008 to 1.000 µg L?1 for each triazine while the limits of detection ranged from 0.001 to 0.004 µg L?1. Solid‐phase extraction recoveries from ground, surface, and waste waters ranged from 64% to 96%. Possible water interferences were investigated. Natural humic acids and salts did not influence the ionization process. The presence of humic acids did not affect binding ability of the solid‐phase sorbent, while the presence of salts increased the extraction efficiency by approximately 10%.  相似文献   

5.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

6.
A rapid, simple, and efficient method using ultrasound-assisted emulsification microextraction combined with dispersive micro-solid phase extraction (USAE-D-µ-SPE) was developed for detection and quantification of three azole antifungals in milk samples by high-performance liquid chromatography diode array detector. In this study, mesoporous carbon, COU-2, was used as sorbent in USAE-D-µ-SPE for the extraction and preconcentration of analytes. Several important experimental parameters, including type of deproteinized solvents, desorption time, type of extraction solvents, volume of extraction solvent, extraction time, emulsification time, sample pH, salt addition, and mass of COU-2 sorbent, were optimized using spiked milk samples. Under the optimum extraction and detection conditions, three azole antifungals, namely ketoconazole, clotrimazole, and miconazole, were determined within 20 min, with good linearity of matrix-matched calibration in the range of 0.5–5000.0 µg L?1 with coefficient of determination, r 2 ≥ 0.9943. The method showed limits of detection and limits of quantification of all analytes in the range of 0.15–3.0 and 0.5–10.0 µg L?1, respectively. Good repeatability with RSDs <15% (n = 3) and satisfactory relative recoveries (83.3–111.1%) were obtained for spiked azole antifungal drugs in milk. The results reveal that the developed USAE-D-µ-SPE method was a simple, rapid, efficient, environmentally friendly, and practicable method for the determination of azole antifungals in milk samples.  相似文献   

7.
In the present study, multiwalled carbon nanotubes (MWCNTs) as solid phase extraction sorbent were developed for preconcentration of arsenic(V) species prior to graphite furnace atomic absorption spectrometry (GFAAS) determination. Arsenic(V) was selectively sorbed on the packed column with MWCNTs within a pH 9.5 in the presence of 2-(5-bromo-2-pyridylazo)-5-diethyl amino phenol (5-Br-PADAP). The adsorbed species was then desorbed with 1 mL of 2.0 M HNO3. Experimental parameters including pH, sample volume and flow rate, type, volume and concentration of eluent that influence the recovery of the arsenic(V) species were optimised. Under the optimised conditions, the calibration curve was linear in the range of 0.2–10.0 µg L?1 with detection limit of 0.016 µg L?1. The relative standard deviations (RSD) for seven replicate determinations at 1.0 µg L?1 level of arsenic was 6.69%. The proposed method was successfully applied to the determination of arsenic in water samples and certified reference material (NIST RSM 1643e).  相似文献   

8.
A multisyringe flow injection system with spectrophotometric detection is presented as a fast, robust and low-reagent consumption system for the determination of azinphos methyl (AzMe) in water samples. Determination is based on the Griess reaction. The analyte is hydrolyzed and the reaction product reacts with nitrite in acid medium to form the diazonium salt that reacts further with 1-naphtol reagent to produce an azo compound. The azo derivative is spectrophotometrically monitored at 485 nm. The influence of several chemical and flow variables has been investigated. Under the optimum analytical conditions, the linearity of the calibration curve for AzMe ranges from 1 to 32 μg mL?1. The detection limit is 0.17?µg mL?1, and recoveries between 95 to 109% have been obtained. The repeatability (RSD) is 0.8% for a 10?μg mL?1 solution, and the injection throughput is seven samples h?1. The system has been satisfactorily applied to the determination of AzMe in spiked river and dam water samples. The results were in agreement at the 95% confidence level with those obtained by HPLC.  相似文献   

9.
《Analytical letters》2012,45(13):1799-1809
A simple, reliable, and effective analytical method was developed for the simultaneous determination of five organotin compounds (OTCs) including monobutyltin trichloride dibutyltin dichloride tributyltin chloride tetrabutyltin and triphenyltin chloride in white wines. The OTCs were derivatized with sodium tetraethylborate (NaBEt4), and their derivatives were extracted by liquid-liquid extraction (LLE) into n-hexane. The experimental variables, such as type and volume of extraction solvents, amount of derivatization reagent NaBEt4 and extraction time were optimized. The determination of ethylated derivatives of OTCs in the final extracts was carried out by gas chromatography-mass spectrometry (GC-MS). Under optimized conditions, good linearity was observed when analytical concentrations were in the range of 0.01–4.0 µg · mL?1, the linearity correlation coefficients were between 0.9982 and 0.9987, with the LODs in the range of 0.2–3.0 µg · L?1, and the LOQs varied from 0.6 to 10.0 µg · L?1. The obtained recoveries were in the range of 78.0–120.0%, with the relative standard deviations equal to or lower than 8.1%. This method was applied to the determination of OTCs in white wines with satisfactory results.  相似文献   

10.
《Analytical letters》2012,45(4):632-646
A new solid phase extraction method based on the application of polyaniline as the sorbent and calmagite as the anionic chelating agent is reported for selective preconcentration of trace copper, prior to its determination by microsample injection system-flame atomic absorption spectrometry. The parameters that influence the extraction and chelate formation were optimized. The copper was retained on a polyaniline minicolumn at pH 4.0 and eluted with 2.0 mL of 3.0 mol L?1 nitric acid. Under the optimum conditions, the limit of detection, the relative standard deviation, and the preconcentration factor were 1.98 µg L?1, less than 5.4%, and 50 to 200, respectively. The method was validated through the analysis of certified reference water samples and standard addition measurements. Quantitative recoveries between 93.4% and 103.5% were obtained. The method was successfully applied to the determination of copper in water.  相似文献   

11.
In this work, magnetic solid-phase extraction based on sodium dodecyl sulfate-coated Fe3O4 nanoparticles has been successfully applied for extraction and preconcentration of trace amounts of nystatin from water and vaccine samples prior to high-performance liquid chromatography–ultraviolet detection. Various experimental parameters affecting extraction and recovery of the analyte, such as the amount of sodium dodecyl sulfate, pH of the sample solution, salt concentration, extraction time, sample volume and desorption conditions, were systematically studied and optimized. Under optimized conditions, nystatin was quantitatively extracted. Proper linear range with good coefficient of determination, (R 2 > 0.99) and limit of detection and quantification (based on signal-to-noise ratios of 3 and 10) of 2.0 and 5.0 µg L?1, over the investigated concentration range (5–700 µg L?1), were obtained, respectively. The intra-day and inter-day relative standard deviations at 50 µg L?1 level of NYS were 1.4 and 4.5% based on six replicate determinations. The accuracy of the method was evaluated by recovery measurements on spiked samples. Suitable recoveries of 96–102 and 26–44% were achieved (at spiked levels of 50, 300 and 500 µg L?1) for water and vaccine samples, respectively.  相似文献   

12.
A selective extraction–spectrophotometric method has been developed for determination of selenium(IV) using O-methoxyphenyl thiourea (OMePT) as a chelating agent. The basis of the proposed method is the spectrophotometric determination of selenium(IV)–OMePT complex obtained after extraction of selenium(IV) from 3.5 M hydrochloric acid media using OMePT in chloroform solvent. The complex shows maximum absorbance at 350 nm against the reagent blank. The Beer’s law was obeyed over the concentration range 5–60 µg mL?1 of selenium(IV). The optimum concentration range was 20–50 µg mL?1 as evaluated from Ringbom’s plot. The molar absorptivity and Sandell’s sensitivity of the selenium(IV)–OMePT complex in chloroform were 3.312 × 102 L mol?1cm?1 and 0.2384 µg cm?2, respectively. The composition of selenium(IV)–OMePT complex was 1:2 established from slope ratio method, mole ratio method and Job’s continuous variation method. The complex was stable for more than 72 h. The interfering effect of various foreign ions was studied and suitable masking agents were used wherever necessary to enhance the selectivity of the developed method. The proposed method was successfully applied for the determination of selenium(IV) from real samples, viz. pharmaceutical formulations, shampoo, vegetable sample, synthetic mixtures and environmental samples. Repetition of the method was checked by finding the relative standard deviation (RSD) for 10 determinations which was 0.35%.  相似文献   

13.
《Analytical letters》2012,45(5):766-782
A combined homogeneous assay and colorimetric determination method using gold nanoparticles was developed for rapid determination of lead(II) in contaminated natural waters. The presence of lead(II) in the colloidal gold suspension causes a change in the absorbance of the suspension. An increase in the absorption property at 595 nm is accompanied by a change in the size of the gold nanoparticles. High concentrations of lead cause aggregation of the gold colloids. Colloidal gold nanoparticles were synthesized using tannic acid as the reducing agent; this reagent allowed selective determination of lead in 10 µL of water, with a detection limit of 310 ng mL?1 with an analysis time of 5 min. The coefficient of variation for lead(II) within the working range of the assay (520 ng mL?1–13 µg mL?1) varied from 1.3% to 9.2%. The limit of detection using this method with a sample volume of 50 µL was 60 ng mL?1. The coefficient of variation for lead over the working range of the determined concentrations (80 ng mL?1–25 µg mL?1) varied from 0.2% to 9.3%, while the values for the inter-day assay (n = 8) were less than 10%. The method was employed for the analysis of river, lake, marsh, and spring water; the recovery of lead was determined to be 72.5%–130% for 10 µL of water and 93.6%–114.7% for 50 µL.  相似文献   

14.
The contamination of water represents a major problem in many parts of the world. Endocrine disrupting compounds belong to the water contaminants and affect, besides other things, hormonal equilibrium in the living organisms. Such compounds are of different chemical structures and there is a demand for their fast determination in water samples. In our work, we focused on the development of a simple and fast method for separation and determination of five model hormone antagonists, exemestane, toremifene, letrozole, anastrozole, and mifepristone, by micellar electrokinetic chromatography. Within the best conditions, 50 mM sodium borate pH 9.5, 50 mM SDS, 15% 1-propanol, 20 kV, the separation of all the compounds lasted 8 min. The method was successfully validated with LODs of 1.2–7.7 µg mL?1, LOQs of 4.0–25.6 µg mL?1 and intraday repeatability of peak areas of 0.8–1.1%. Moreover, it was applied to the analysis of spiked water samples from a local waste-water treatment plant using SPE as a pretreatment step.  相似文献   

15.
《Analytical letters》2012,45(16):2359-2366
Phenolic compounds are one of the major compounds in Laminaria japonica Aresch. Solid-phase extraction was used to separate the two phenolic compounds (4-hydroxybenzoic acid and 4-hydroxybenzaldehyde). A new monolithic sorbent was developed and used successfully as a special sorbent in a solid-phase extraction process. The effects on different SPE cartridges using silica, C18, and monolithic were compared. Quantitative analysis was carried out using a C18 analysis column (5 µm, 150 × 4.6 mm). Good linearity was obtained for the two targets, ranging from 0.5 to 100 µg mL?1 (r 2  > 0.999), with relative standard deviations <4.7%.  相似文献   

16.
《Analytical letters》2012,45(7):1333-1347
Abstract

A multianalyte flow‐through sensor is proposed for the simultaneous determination of aspartame (AS) and acesulfame‐K (AK) in tabletop sweeteners. The procedure is based on the transient retention of AK in the ion exchanger Sephadex DEAE A‐25 placed in the flow‐through cell of a monochannel flow injection analysis (FIA) set‐up using pH 2.70 ortophosphoric acid/sodium dihydrogen phosphate buffer 0.06 M as carrier. In these conditions AS is very weakly retained, which makes it possible to measure the intrinsic ultraviolet (UV) absorbance of first AS and then AK after desorption by the carrier itself. The applicable concentration range, the detection limit, and the relative standard deviation were the following: for AS, from 10 to 100 µg mL?1; 5.65 µg mL?1; 3.4% (at 50 µg mL?1); and for AK, between 40 and 100 µg mL?1; 11.9 µg mL?1 and 1.61% (at 50 µg mL?1). The method was applied and validated satisfactorily for the determination of AS and AK blends in tabletop sweeteners. The results were compared against an HPLC reference method.  相似文献   

17.
The possibility of using ionic liquid based chitosan sorbent for the separation and preconcentration of fluoroquinolone antibiotics (marbofloxacin, enoxacin, ofloxacin, ciprofloxacin, and enrofloxacin) has been studied. For this reason, different ionic liquids were prepared and coated on the chitosan sorbent. The conditions of the preconcentration of fluoroquinolones on a microcolumn have been optimized and the extraction efficiencies of the prepared sorbents have been compared. The compounds were eluted with 5 mL of 20% NH3 (v/v, MeOH) solution and determined by HPLC with diode array and fluorescence detector. The limits of detection were found as 4.23 µ g L?1 for marbofloxacin, and 1.09 µg L?1 for enoxacin; 3.23 × 10?3 µg L?1 for ofloxacin; 8.39 × 10?3 µg L?1 for ciprofloxacin; and 19.50 × 10?3 µg L?1 for enrofloxacin. The developed method was applied for the analysis of fluoroquinolone in milk, egg, fish, bovine, and chicken samples and the recoveries were obtained in the range 70–100%.  相似文献   

18.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

19.
A novel magnetic dispersive solid phase extraction method using magnetic multi-walled carbon nanotubes modified with 5-mercapto-3-phenyl-1,3,4-thiadiazole-2-thione potassium salt (bismuthiol II) (MMWCNTs@Bis) as the sorbent was developed for the separation and preconcentration of inorganic selenium (IV) prior to its determination by electrothermal atomic absorption spectrometry. The prepared MMWCNTs@Bis sorbent was characterised by Fourier transform infrared spectroscopy, scanning electron microscopy, vibrating sample magnetometer and X-ray diffraction. Total selenium was determined after reduction of Se(VI) to Se(IV) by addition of hydrochloric acid and heating the mixture in a boiling water bath. Se(VI) concentration was determined from the difference between the amounts of total selenium and Se(IV). Under the optimised experimental conditions, an enhancement factor of 196 and a detection limit (based on 3Sb/m) of 0.003 µg L?1 was obtained for aqueous samples. The relative standard deviation at 0.1 µg L?1 concentration level of Se(IV) (n = 6) was found to be 5.2 and 7.7% for intra- and inter-day analysis, respectively. The method was successfully applied to the determination of inorganic selenium species in water and total selenium in food samples.  相似文献   

20.
《Analytical letters》2012,45(3):579-587
Abstract

This paper reports on the synthesis of a new chromogenic reagent, 2‐carboxyl‐1‐naphthalthiorhodanine (CNTR). A high sensitive, selective, and rapid method for the determination of gold based on the rapid reaction of gold with CNTR and the solid phase extraction of the colored chelate with a reversed phase polymer‐based C18 cartridge was developed. In the presence of 0.05–0.5 mol L?1 of phosphoric acid solution and emulsifier‐OP medium, CNTR reacts with gold to form a red chelate of a molar ratio 1∶3 (gold to CNTR). This chelate was enriched by the solid phase extraction with a polymer‐based C18 cartridge and the retained chelate was eluted from the cartridge with dimethyl formamide (DMF). The enrichment factor of 100 was achieved. In the DMF medium, the molar absorptivity of the chelate is 1.35×105 L · mol?1 · cm?1 at 540 nm. Beer's law is obeyed in the range of 0.01~2 µg mL?1 in the measured solution. The relative standard deviation for 11 replicates sample of 0.5 µg L?1 level is 2.05%. The detection limit, based on three times the standard deviation is 0.02 µg L?1 in the original sample. This method was applied to the determination of gold in water and ore with good results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号