首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Graphene nanosheets modified glassy carbon electrode (GNs/GCE) was fabricated as voltammetric sensor for rutin with good sensitivity, selectivity and reproducibility. The sensor exhibits an adsorption‐controlled, reversible two‐proton and two electron transfer reaction for the oxidation of rutin with a peak‐to‐peak separation (ΔEp) of 26 mV as revealed by cyclic voltammetry. Moreover, the redox peak current increased about 14 times than that on bare glassy carbon electrode (GCE). The linear response of the sensor is from 1×10?7 to 1×10?5 M with a detection limit of 2.1 × 10?8 M (S/N = 3). The method was successfully applied to determine rutin in tablets with satisfied recovery.  相似文献   

2.
The voltammetric behaviour of two anthraquinone dyes such as Alizarin Red S (ARS) and Reactive blue 4 (RB4) was investigated at plain glassy carbon electrode (GCE), multiwalled carbon nano tube modified GCE (MWCNT/GCE) and zeolite modified GCE (ZE/GCE) using cyclic voltammetry. Effects of pH, scan rate and concentration were studied. The surface morphology of the modified electrode in the absence and presence of dye molecules was characterized by scanning electron microscopy (SEM). A systematic study on the variation of experimental parameters with differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived. MWCNT/GCE performed well among the three electrode systems and the limit of detection (LOD) was 0.036?µg?mL?1 for ARS and 0.05?µg?mL?1 for RB4 on this modified system. Suitability of the differential pulse stripping voltammetric method for the trace determination of textile dyes in effluents was also realized.  相似文献   

3.
A voltammetric method using a poly(1‐methylpyrrole) modified glassy carbon electrode was developed for the quantification of adrenaline. The modified electrode exhibited stable and sensitive current responses towards adrenaline. Compared with a bare GCE, the modified electrode exhibits a remarkable shift of the oxidation potentials of adrenaline in the cathodic direction and a drastic enhancement of the anodic current response. The separation between anodic and cathodic peak potentials (ΔEp) for adrenaline is 30 mV in 0.1 M phosphate buffer solution (PBS) at pH 4.0 at modified glassy carbon electrodes. The linear current response was obtained in the range of 7.5 × 10?7 to 2.0 × 10?4 M with a detection limit of 1.68 × 10?7 M for adrenaline by square wave voltammetry. The poly(1‐methypyrrole)/GCE was also effective to simultaneously determine adrenaline, ascorbic acid and uric acid in a mixture and resolved the overlapping anodic peaks of these three species into three well‐defined voltammetric peaks in cyclic voltammetry. The modified electrode has been successfully applied for the determination of adrenaline in pharmaceuticals. The proposed method showed excellent stability and reproducibility.  相似文献   

4.
《Electroanalysis》2006,18(12):1202-1207
A new type of current sensor, Langmuir–Blodgett (LB) film of calixarene on the surface of glassy carbon electrode (GCE) was prepared for determination of mercury by anodic stripping voltammetry (ASV). An anodic stripping peak was obtained at 0.15 V (vs. SCE) by scanning the potential from ?0.6 to +0.6 V. Compared with a bare GCE, the LB film coated electrode greatly improves the sensitivity of measuring mercury ion. The fabricated electrode in a 0.1 M H2SO4+0.01 M HCl solution shows a linear voltammetric response in the range of 0.07–40 μg L?1 and detection limit of 0.04 μg L?1 (ca. 2×10?10 M). The high sensitivity, selectivity, and stability of this LB film modified electrode demonstrates its practical application for a simple, rapid and economical determination of Hg2+ in a water sample.  相似文献   

5.
A sensitive voltammetric technique has been developed for the determination of Fludarabine using amine‐functionalized multi walled carbon nanotubes modified glassy carbon electrode (NH2‐MWCNTs/GCE). Molecular dynamics simulations, an in silico technique, were employed to examine the properties including chemical differences of Fludarabine‐ functionalized MWCNT complexes. The redox behavior of Fludarabine was examined by cyclic, differential pulse and square wave voltammetry in a wide pH range. Cyclic voltammetric investigations emphasized that Fludarabine is irreversibly oxidized at the NH2‐MWCNTs/GCE. The electrochemical behavior of Fludarabine was also studied by cyclic voltammetry to evaluate both the kinetic (ks and Ea) and thermodynamic (ΔH, ΔG and ΔS) parameters on NH2‐MWCNTs/GCE at several temperatures. The mixed diffusion‐adsorption controlled electrochemical oxidation of Fludarabine revealed by studies at different scan rates. The experimental parameters, such as pulse amplitude, frequency, deposition potential optimized for square‐wave voltammetry. Under optimum conditions in phosphate buffer (pH 2.0), a linear calibration curve was obtained in the range of 2×10?7 M–4×10?6 M solution using adsorptive stripping square wave voltammetry. The limit of detection and limit of quantification were calculated 2.9×10?8 M and 9.68×10?8 M, respectively. The developed method was applied to the simple and rapid determination of Fludarabine from pharmaceutical formulations.  相似文献   

6.
《Electroanalysis》2017,29(5):1451-1458
A glassy carbon electrode (GCE) was modified by electrochemically reduced graphene oxide (ERGO) for subsequent dsDNA immobilization. The interaction of cisplatin with dsDNA was studied at this modified electrode. Quantitative investigations were performed by adsorptive transfer stripping voltammetry (AdTSV) using differential pulse voltammetry (DPV). The morphology and structure of graphene oxide (GO) and ERGO modified GCEs (GO/GCE and ERGO/GCE, respectively) were characterized by UV‐vis, FT‐IR, Raman spectroscopy and cyclic voltammetry. Compared with the bare GCE and the GO/GCE, the ERGO/GCE exhibited excellent electrocatalytic activity towards the oxidation of dsDNA due to guanine and adenine groups, testified by high oxidation peak currents and decreased oxidation potentials. The interaction of micromolar concentrations of cisplatin with surface confined dsDNA was readily detected as inferred from the decrease of the voltammetric oxidation peaks of guanine and adenine. This trend was significantly greater at the ERGO/GCE compared to the GO/GCE. The interaction of cisplatin with dsDNA was also studied in solution phase by AdTSV with detection at the ERGO/GCE.  相似文献   

7.
A simple, rapid fabricated and sensitive modified electrode for detection of As(III) in alkaline media was proposed. The modified electrode was prepared by co‐electrodeposition of manganese oxides (MnOx) and gold nanoparticles (AuNPs) on the glassy carbon electrode (GCE) with cyclic voltammetry. Linear sweep anodic stripping voltammetry (LS‐ASV) was employed for the determination of arsenic (III) without interference from Cu(II), Hg(II), and other coexisting metal ions. A lower detection limit of 0.057 µg L?1 (S/N=3) were obtained with a accumulation time of 200 s. The proposed method was successfully applied to determine arsenic (III) in real water samples with satisfactory recoveries.  相似文献   

8.
《Analytical letters》2012,45(10):1184-1196
The electrochemical detection of As(III) was investigated on the novel citrate stabilized gold nanoparticle modified glassy carbon electrode (AuNPs/GCE) in 1 M HCl by square wave anodic stripping voltammetry. AuNPs/GCE was prepared by simply casting citrate stabilized gold nanoparticles onto the well-polished glassy carbon electrode. Gold modification was evaluated by cyclic voltammetry, while transmission electron microscopy and UV-vis Spectroscopy revealed the size and distribution of gold nanoparticles. Anodic stripping voltammetry was performed with the modified electrode in As(III) solution. Electrochemical experiments proved that AuNPS/GCE exhibited good performance for As(III) analysis, the linear range were obtained between 0.05 and 1 ppb for trace level of As(III) as well as 1 to 15 ppb, with a limit of detection of 0.025 ppb. In terms of reproducibility, the precision of the aforementioned method in %RSD was calculated at 7.78% (n = 10), and the repeatability of the proposed method was calculated to be 1.59%. The application of the method to analyze As(III) in tap water was investigated.  相似文献   

9.
A carbon‐coated iron nanoparticles (CIN, a new style fullerence related nanomaterial) modified glassy carbon electrode (CIN/GCE) has been developed for the determination of uric acid (UA). Electrochemical behaviors of UA on CIN/GCE were explored by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the voltammetric response of UA on CIN/GC was enhanced dramatically because of the strong accumulation effect of CIN and the large working area of the CIN/GC electrode. The parameters including the pH of supporting electrolyte, accumulation potential and time, that govern the analytical performance of UA have been studied and optimized. The DPV signal of UA on CIN/GCE increased linearly with its concentration in the range from 5.0×10?7 to 2.0×10?5 M, with a detection limit of 1.5×10?7 M (S/N=3). The CIN/GCE was used for the determination of UA in samples with satisfactory results. The proposed CIN/GCE electrochemical sensing platform holds great promise for simple, rapid, and accurate detection of UA.  相似文献   

10.

The two adsorptive stripping voltammetric approaches for detection and quantitative determination of diethyl (2E)-2-{(2E)-[1-(4-methylphenyl)imidazolidin-2-ylidene]hydrazinylidene}butanedioate (DIB)—a novel molecule of medical importance—using two sensitive sensors based on modified glassy carbon electrodes as reusable sensors, were developed for the first time. The proposed electrochemical methods are based on adsorptive/reductive behaviour of DIB at two modified carbonic electrodes: a bismuth film-modified glassy carbon electrode (BiF/GCE) and a lead film-modified glassy carbon electrode (PbF/GCE). The electron gain mechanism for the electrochemical reduction of DIB on both developed sensors was proposed for the first time. To achieve the highest sensitivity in adsorptive stripping determinations, various experimental variables (e.g. the composition and pH of the supporting electrolytes, deposition conditions of bismuth and lead films, concentrations of plating solutions, accumulation times and potentials of DIB, etc.) were extensively examined. The comparison of validation parameters obtained during the determination of DIB at two sensors was presented. The excellent linear correlation was found between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 15–600 μg L−1 at an accumulation time of 30 s (with LOD = 4.2 μg L−1 and LOQ = 14.0 μg L−1) using the BiF/GCE as a sensor. Furthermore, the excellent linear relationship was confirmed between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 9–900 μg L−1 at an accumulation time of 10 s (with better LOD = 1.5 μg L−1 and LOQ = 5.0 μg L−1), employing the PbF/GCE as a sensor. The two optimized adsorptive stripping voltammetric approaches—as facile, sensitive, reliable and inexpensive—were successfully used as first methods for the quantitative analysis of a novel anticancer agent (DIB) in its pure pharmaceutically acceptable form. However, the practical applicability of square-wave adsorptive stripping voltammetric determination of the electroactive DIB molecule at a PbF/GCE, as the modified electrode of higher sensitivity, was presented after its successful solid phase extraction from a real serum sample.

  相似文献   

11.
A new type of voltammetric sensor, Langmuir‐Blodgett (LB) film of 5,11,17,23‐tetra‐tert‐butyl‐25,27‐di(3‐thiadiazole‐propanoxy)‐26,28‐dihydroxycalix[4]arene modified glassy carbon electrode (LBTZCA–GCE), was prepared. The electrochemical properties of LBTZCA–GCE were researched in detail and its recognizing mechanism for silver ion in aqueous solution was discussed. Using this voltammetric sensor, a new stripping voltammetric method for determining of Ag+ was erected with good sensitivity, selectivity, reproducibility and recovery. The detection limit was 8×10?9 M at accumulation time of 180 s. By this method, real samples (lake water, tap water and synthesis sample) were analyzed and the results obtained were well satisfactory.  相似文献   

12.
《中国化学会会志》2017,64(11):1360-1366
Nitrogen‐doped graphene (NG) was used to modify a glassy carbon electrode (GCE), which was applied to the voltammetric detection of uric acid (UA). Because of the presence of NG on the GCE surface, the modified electrode showed excellent electrocatalytic ability for UA oxidation with increase of the peak current and decrease of the peak potential. Compared to that of the traditional GCE, the overpotential of the oxidation peak decreased by 50 mV. Electrochemical performance of UA was studied on NG/GCE in detail, which showed a quasi‐reversible, diffusional‐controlled process. Electrochemical parameters including the charge transfer coefficient (α ), the number of electron transfer (n ), and the diffusional coefficient (D ) were calculated. At the optimal conditions, the oxidation peak current was linear, with UA concentration from 0.1 to 10.0 μmol/L as revealed by differential pulse voltammetry, and the detection limit was estimated as 0.042 μmol/L (3σ). The UA content in the urine sample of a healthy volunteer was determined by the proposed method with a recovery of 98.7–102.3%.  相似文献   

13.
A carbon paste electrode was modified by electropolymerisation of benzoin using voltammetric technique. A novel polybenzoin modified carbon paste electrode (PB‐CPE) was developed for use as a detector in cyclic voltammetry and differential pulse adsorptive stripping voltammetry for the sensitive determination of 2thiouracil (2TU). The atomic force microscopy was applied to characterize the surface morphology of PB‐CPE. The modified electrode showed excellent electrocatalytic activity for the oxidation of 2TU. The oxidation process was irreversible over the pH range studied and exhibited a diffusion controlled behavior. All experimental parameters have been optimized. The peak current for the stripping of 2TU was found to be linear over the concentration range of 0.2–1.2 µM, with a detection limit of 2.21 nM. The practical application of the PB‐CPE in the determination of 2TU in human biological fluids and pharmaceutical samples were demonstrated that it has high sensitivity and good selectivity.  相似文献   

14.
This work presents a sensitive voltammetric method for determination of folic acid by adsorbing methylene blue onto electrodeposited reduced graphene oxide film modified glassy carbon electrode (MB/ERGO/GCE) in 100 mM KCl‐10 mM sodium phosphate buffer solution (pH 7.40). The surface morphology of the MB/ERGO/GCE modified electrode was characterized using scanning electron microscopy, displays that both MB and ERGO distributed homogeneously on the surface of GCE. The MB/ERGO/GCE modified electrode shows more favorable electron transfer kinetics for potassium ferricyanide and potassium ferrocyanide probe molecules, which are important electroactive compounds, compared with bare GCE, MB/GCE, and ERGO/GCE. The electrochemical behaviors of folic acid at MB/ERGO/GCE were investigated by cyclic voltammetry, suggesting that the modified electrode exhibited excellent electrocatalytic activity towards folic acid compared with other electrodes. Under physiological condition, the MB/ERGO/GCE modified electrode showed a linear voltammetric response from 4.0 μM to 167 μM for folic acid, and with the detection limit of 0.5 μM (S/N=3). The stability, reproducibility and anti‐interference ability of the modified electrode were examined. The developed method has been successfully applied to determination of FA in tablets with a satisfactory recovery from 96 % to 100 %. The work demonstrated that the electroactive MB adsorbing onto graphene modified electrode showed an enhanced electron transfer property and a high resolution capacity to FA.  相似文献   

15.
A highly sensitive electrochemical biosensor for the detection of trace amounts of 8‐azaguanine has been designed. Double stranded (ds)DNA molecules are immobilized onto a glassy carbon electrode surface with Langmuir–Blodgett technique. The adsorptive voltammetric behaviors of 8‐azaguanine at DNA‐modified electrode were explored by means of cyclic voltammetry and square wave voltammetry. Compared with bare glassy carbon electrode (GCE), the Langmuir–Blodgett film modified electrode can greatly improve the measuring sensitivity of 8‐azaguanine. Under the optimum experimental conditions, the Langmuir–Blodgett film modified electrode in pH 3.0 Britton–Robinson buffer solutions shows a linear voltammetric response in the range of 5.0×10?8 to 1.0×10?5 mol L?1 with detection limit 9.0×10?9 mol L?1. The method proposed was applied successfully for the determination of 8‐azaguanine in diluted human urine with wonderful satisfactory.  相似文献   

16.
预镀铋膜阳极溶出伏安法测定废水中微量铅和镉   总被引:3,自引:0,他引:3  
本文采用预镀铋膜法修饰玻碳电极,并用该电极对废水中微量铅和镉同时进行了阳极溶出伏安法测定,研究了预镀铋膜测定铅和镉的条件。实验结果表明:铅和镉在铋膜电极上可得到灵敏的电位溶出峰,峰高和溶出电位与汞膜电极法相近,使用预镀铋膜电极可避免使用汞电极带来的环境污染。  相似文献   

17.
The Cu (II) imprinted polymer glassy carbon electrode (GCE/Cu-IP) was prepared by electropolymerization of pyrrole at GCE in the presence of methyl red as a dopant and then imprinting by Cu2+ ions. This electrode was applied for potentiometric and voltammetric detection of Cu2+ ion. The potentiometric response of the electrode was linear within the Cu2+ concentration range of 3.9 × 10?6 to 5.0 × 10?2 M with a near-Nernstian slope of 29.0 mV decade?1 and a detection limit of 5.0 × 10?7 M. The electrode was also used for preconcentration anodic stripping voltammetry and results exhibited that peak currents for the incorporated copper species were dependent on the metal ion concentration in the range of 1.0 × 10?8 to 1.0 × 10?3 M and detection limit was 6.5 × 10?9 M. Also the selectivity of the prepared electrode was investigated. The imprinted polymer electrode was used for the successful assay of copper in two standard reference material samples.  相似文献   

18.
A glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNTs) and a hydrophobic ionic liquid (IL), was used for the simultaneous voltammetric determination of theophylline (TP) and guaifenesin (GF). The results showed that the oxidations of TP and GF were facilitated at modified electrode and peak‐to‐peak separation at MWCNT? IL/GCE (252 mV) was larger than that observed at unmodified GCE (165 mV). Voltammetric signals for TP and GF exhibited linear ranges of 0.5 to 98.0 µM (R2>0.99) and 1.5 to 480.0 µM (R2>0.99), respectively. The method was used to estimate TP and GF contents in some real samples.  相似文献   

19.
A selective and simple biosensor was prepared by immobilizing chitosan/nickelnanoparticles/multi-walled carbon nanotubes biocomposite on the glassy carbon electrode surface for voltammetric quantification of neotame. The properties and morphology of the modified electrode surfaces were characterized by scanning electron microscope (SEM), energy dispersive X-ray analysis (EDX). Electro oxidation of neotame on this modified surface was examined through cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. The biocomposite modified surface (Chi/NiNPs/MWCNTs/GCE) proposed in this study showed good electrocatalytic activity for neotame with an improved voltammetric peak current at 1.004 V, unlike the bare glassy carbon electrode (GCE) surface and several other modified surfaces. Under optimum conditions, Chi/NiNPs/MWCNTs/GCE gave linear SWV responses at the range of 2 μM ∼50 μM for neotame with 0.84 μM determination limit. This voltammetric sensor was successfully employed for the quantification of neotame on food samples and showed long-term stability, advanced voltammetric behavior, and good repeatability. Selective, accurate, and precise determination of neotame highlight the importance of this electrode in monitoring the control of food additives and ensures attract a great deal of attention.  相似文献   

20.
Electrochemically polymerized luminol film on a glassy carbon electrode (GCE) surface has been used as a sensor for selective detection of uric acid (UA) in the presence of ascorbic acid (AA) and dopamine (DA). Cyclic voltammetry was used to evaluate the electrochemical properties of the poly(luminol) film modified electrode. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) have been used for surface characterizations. The bare GCE failed to distinguish the oxidation peaks of AA, DA and UA in phosphate buffer solution (pH 7.0), while the poly(luminol) modified electrode could separate them efficiently. In differential pulse voltammetric (DPV) measurements, the modified GCE could separate AA and DA signals from UA, allowing the selective determination of UA. Using DPV, the linear range (3.0×10?5 to 1.0×10?3 M) and the detection limit (2.0×10?6 M) were estimated for measurement of UA in physiological condition. The applicability of the prepared electrode was demonstrated by measuring UA in human urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号