首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
In this paper, we report a double-receptor sandwich type fluorescence sensing method for the determination of fructose bisphosphates (FBPs) using fructose 1,6-bisphosphate (F-1,6-BP) as a model analyte based on uranyl–salophen complexes. The solid phase receptor is an immobilized uranyl–salophen (IUS) complex which is bound on the surface of glass slides by covalent bonds. The labeled receptor is another uranyl–salophen complex containing a fluorescence group, or uranyl–salophen–fluorescein (USF). In the procedure of determining F-1,6-BP in sample solution, F-1,6-BP is first adsorbed on the surface of the glass slide through the coordination reaction of F-1,6-BP with IUS. It then binds USF through another coordination reaction to form a sandwich-type structure of IUS-F-1,6-BP-USF. The amount of F-1,6-BP is detected by the determination of the fluorescence intensity of IUS-F-1,6-BP-USF bound on the glass slide. Under optimal conditions, the linear range for the detection of F-1,6-BP is 0.05–5.0 nmol mL−1 with a detection limit of 0.027 nmol mL−1. The proposed method has been successfully applied for the determination of F-1,6-BP in real samples with satisfactory results.  相似文献   

2.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

3.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

4.
A novel ultrasound-assisted surfactant-enhanced emulsification microextraction (UASEME) coupled with high performance liquid chromatography-diode array detection has been developed for the extraction and determination of six carbamate pesticides (metolcarb, carbofuran, carbaryl, pirimicarb, isoprocarb and diethofencarb) in water samples. In the UASEME technique, Tween 20 was used as emulsifier, and chlorobenzene and chloroform were used as dual extraction solvent without using any organic dispersive solvent that is normally required in the previously described common dispersive liquid–liquid microextraction method. Parameters that affect the extraction efficiency, such as the kind and volume of the extraction solvent, the type and concentration of the surfactant, ultrasound emulsification time and salt addition, were investigated and optimized for the method. Under the optimum conditions, the enrichment factors were in the range between 170 and 246. The limits of detection of the method were 0.1–0.3 ng mL−1 and the limits of quantification were between 0.3 and 0.9 ng mL−1, depending on the compounds. The linearity of the method was obtained in the range of 0.3–200 ng mL−1 for metolcarb, carbaryl, pirimicarb, and diethofencarb, 0.6–200 ng mL−1 for carbofuran, and 0.9–200 ng mL−1 for isoprocarb, with the correlation coefficients (r) ranging from 0.9982 to 0.9998. The relative standard deviations varied from 3.2 to 4.8% (n = 5). The recoveries of the method for the six carbamates from water samples at spiking levels of 1.0, 10.0, 50.0 and 100.0 ng mL−1 were ranged from 81.0 to 97.5%. The proposed UASEME technique has demonstrated to be simple, practical and environmentally friendly for the determination of carbamates residues in river, reservoir and well water samples.  相似文献   

5.
Orthogonal array design (OAD) was utilized for the first time to optimize the experimental conditions of ultrasound-assisted emulsification–microextraction (USAEME) for determining chlorinated phenoxyacetic acids (CPAs) in river water samples. The use of ultrasound facilitates the mass transfer of CPAs from an aqueous phase into a water-immiscible organic extraction solvent (dichloromethane, DCM) without adding dispersive solvent to form numerous microdroplets. The water-immiscible extractant was collected by centrifugation, dried under low pressure, reconstituted in methanol–water mixture (1:1), and injected into a HPLC system for the determination of CPAs. The linear range was 2–1000 ng mL−1 (2, 5, 10, 50, 200, 500 and 1000 ng mL−1) for each analyte and the relative standard deviations of CPAs among the seven different concentrations were in the range of 1.5–17.0% (n = 3). The detection limits (signal-to-noise ratio of 3) of CPAs ranged from 0.67 to 1.50 ng mL−1. The ranges of intra-day precision (n = 3) for CPAs at the levels of 5 and 200 ng mL−1 were 3.6–11.9% and 5.3–9.5%, respectively. The range of inter-day precision (n = 3) at 5 and 200 ng mL−1 were 1.4–7.7% and 8.5–12.2%, respectively. The applicability of USAEME for environmental analysis was demonstrated by determining CPAs in river water. The recoveries of CPAs from five-spiked river water samples at 10 and 200 ng mL−1 were 96.3–112.5% and 94.8–109.4%, respectively. The maximum contaminant level (MCL) of 2,4-D in drinking water and the tolerance of residues in food for p-CPA are 70 and 200 μg L−1, respectively, according to the US EPA regulations. These contaminant levels fall in the linear range investigated in this study. In addition, this USAEME method provided detection limits lower than their contaminant levels, which made USAEME an effective sample preparation method for determining organic environmental contaminants, such as CPAs, in river water samples with little consumption of organic solvent.  相似文献   

6.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

7.
A simple and fast method of low-density extraction solvent-based solvent terminated dispersive liquid–liquid microextraction (ST-DLLME) was developed for the highly sensitive determination of carbamate pesticides in the water samples by gas chromatography-tandem mass spectrometry (GC-MSMS). After dispersing, the obtained emulsion cleared into two phases quickly when an aliquot of acetonitrile was introduced as a chemical demulsifier into the aqueous bulk. Therefore, the developed procedure does not need centrifugation to achieve phase separation. It was convenient for the usage of low-density extraction solvents in DLLME. Under the optimized conditions, the limits of detection for all target carbamate pesticides were in range of 0.001–0.50 ng mL−1 and the precisions were in the range of 2.3–6.8% (RSDs, 2 ng mL−1, n = 5). The proposed method has been successfully applied to the analysis of real water samples and good spiked recoveries over the range of 94.5–104% were obtained.  相似文献   

8.
Xi C  Liu Z  Kong L  Hu X  Liu S 《Analytica chimica acta》2008,613(1):83-90
In pH 4.2-4.8 HAc-NaAc buffer solution, folic acid (FA) could react with uranium (VI) to form a 2:1 anionic chelate which further reacted with some basic triphenylmethane dyes (BTPMD) such as Ethyl Violet (EV), Methyl Violet (MV) and Crystal Violet (CV) to form 1:2 ion-association complexes. As a result, not only the absorption spectra were changed, but also the intensities of resonance Rayleigh scattering (RRS) were enhanced greatly and the new RRS spectra were observed. The maximum RRS wavelengths were located at 328 nm for EV system, 325 nm for MV system and 328 nm for CV system. The fading degree (ΔA) and RRS intensities (ΔI) of three systems were different. Under given conditions, the ΔA and ΔI were all directly proportional to the concentration of FA. The linear ranges and the detection limits of RRS methods were 0.0039-5.0 μg mL−1 and 1.2 ng mL−1 for EV system, 0.0073-4.0 μg mL−1 and 2.2 ng mL−1 for MV system, 0.014-3.5 μg mL−1 and 4.7 ng mL−1 for CV system. The RRS methods exhibited higher sensitivity, so they are more suitable for the determination of trace FA. The optimum conditions, the influencing factors and the effects of coexisting substances on the reaction were investigated. The method can be applied to the determination of FA in serum and urine samples with satisfactory results. The structure of the ternary ion-association complex and the reaction mechanism were discussed in this work.  相似文献   

9.
Liu R  Xing Z  Lv Y  Zhang S  Zhang X 《Talanta》2010,83(1):48-54
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions (197Au+) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3σ) of 0.1 ng mL−1 was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL−1 and a RSD of 8.1% (2.0 ng mL−1). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay.  相似文献   

10.
The aim of the present work is combination of the advantages of magnetic solid phase extraction (MSPE) and dispersive liquid phase microextraction (DLLME) followed by filtration-based phase separation. A new pretreatment method was developed for trace determination of megestrol acetate and levonorgestrel by liquid chromatography/ultraviolet detection in biological and wastewater samples. After magnetic solid phase extraction, the eluent of MSPE was used as the disperser solvent for DLLME. Emulsion resulted from DLLME procedure was passed through the in-line filter for phase separation. Finally the retained analytes in the filter was washed with mobile phase of liquid chromatography and transferred to the column for separation. This approach offers the preconcentration factors of 3680 and 3750 for megestrol acetate and levonorgestrel, respectively. This guarantees determination of the organic compounds at trace levels. The important parameters influencing the extraction efficiency were studied and optimized. Under the optimal extraction conditions, a linear range of 0.05–50 ng mL−1 (R2 > 0.998) and limit of detection of 0.03 ng mL−1 were obtained for megestrol acetate and levonorgestrel. Under optimal conditions, the method was successfully applied for determination of target analytes in urine and wastewater samples and satisfactory results were obtained (RSDs < 6.8%).  相似文献   

11.
Hemimicelles of tetradecanoate chemisorbed onto magnetic nanoparticles (MNPs) are here proposed as a sorbent for the single-step extraction and cleanup of bisphenol A (BPA) in soft drinks. The purpose of this work was to develop a simple, rapid and low-cost sample treatment suitable to assess the human exposure to BPA from this type of high consumption food. The nanoparticles were easily coated by mixing commercially available magnetite of 20–30 nm mean particle diameter with tetradecanoate at 85 °C for 30 min. The extraction/cleanup procedure involved stirring the samples (3 mL) with 200 mg of tetradecanoate-coated MNPs for 20 min, isolating the sorbent with a Nd–Fe–B magnet and eluting BPA with methanol. The extraction efficiency was not influenced by salt concentrations up to 1 M and pH values over the range 4–9. No cleanup of the extracts was needed, and the method proved matrix-independent. The extracts were analyzed by liquid chromatography, electrospray ionization tandem mass spectrometry. Quantitation was performed by internal standard calibration using BPA-13C12. The limit of quantitation obtained for the method, 0.03 ng mL−1, was below the usual range of concentrations reported for BPA in soft drinks (0.1–3.4 ng mL−1). The proposed method was successfully applied to the determination of BPA in different samples acquired from various supermarkets in southern Spain; the concentrations found ranged from 0.066 to 1.08 ng mL−1. Recoveries from samples spiked with 0.33 ng mL−1 of BPA ranged from 91% to 105% with relative standard deviations from 3% to 8%.  相似文献   

12.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

13.
A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection–anodic stripping voltammetry (SI–ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at −1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 μL s−1. An anodic stripping voltammogram was recorded from −0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at −0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1–30.0 ng mL−1 and 5.0–60.0 ng mL−1). The limit of detection (S/N = 3) obtained from the experiment was found to be 0.04 ng mL−1. The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL−1, respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level.  相似文献   

14.
A simple, rapid and sensitive method based on microextraction in packed syringe (MEPS), in combination with gas chromatography–mass spectrometry (GC–MS) was developed. Polyaniline (PANI) nanowires network was synthesized and used as sorbent of MEPS for the multiresidue determination of selected analytes from triazine, organochlrorine and organophosphorous pesticides in aqueous samples. The PANI nanowires network was prepared using soft template technique and its characterization was studied by scanning electron microscopy (SEM). The presence of micelles in this methodology showed to be an important parameter in shaping the growing polymer. Hexadecyltrimethylammonium bromide (HTAB) was used as structure directing agent in PANI preparation procedure and this was led to the formation of nanowires with diameters ranging from 35 nm to 45 nm. The synthesized PANI nanowires network showed higher extraction capability in comparison with the bulk PANI. Important parameters influencing the extraction and desorption processes including desorption solvent, elution volume, draw–eject cycles of sample, draw–eject mode, pH effect and amount of sorbent were optimized. Limits of detection were in the range of 0.07–0.3 ng mL−1 using time scheduled selected ion monitoring (SIM) mode. The linearity of method was in the range from 0.5–200 ng mL−1 to 0.2–1000 ng mL−1. The method precision (RSD %) with three replicates were in the range of 5.3–18.4% at the concentration level of 5 ng mL−1. The developed method was successfully applied to the Zayandeh-rood river water samples and the matrix factor obtained for the spiked real water samples were in the range of 0.79–0.94.  相似文献   

15.
A simple dispersive solid-phase micro-extraction method based on CoFe2O4 nano-particles (NPs) functionalized with 8-hydroxyquinoline (8-HQ) with the aid of sodium dodecyl sulfate (SDS) was developed for separation of Al(III) ions from aqueous solutions. Al(III) ions are separated at pH 7 via complex formation with 8-HQ using the functionalized CoFe2O4 nano-particles sol solution as a dispersed solid-phase extractor. The separated analyte is directly quantified by a spectrofluorometric method at 370 nm excitation and 506 nm emission wavelengths. A comparison of the fluorescence of Al(III)–8-HQ complex in bulk solution and that of Al(III) ion interacted with 8-HQ/SDS/CoFe2O4 NPs revealed a nearly 5-fold improvement in intensity. The experimental factors influencing the separation and in situ monitoring of the analyte were optimized. Under these conditions, the calibration graph was linear in the range of 0.1–300 ng mL−1 with a correlation coefficient of 0.9986. The limit of detection and limit of quantification were 0.03 ng mL−1 and 0.10 ng mL−1, respectively. The inter-day and intra-day relative standard deviations for six replicate determinations of 150 ng mL−1 Al(III) ion were 2.8% and 1.7%, respectively. The method was successfully applied to direct determine Al(III) ion in various human serum and water samples.  相似文献   

16.
Fu S  Liu Z  Liu S  Liu J  Yi A 《Analytica chimica acta》2007,599(2):271-278
In pH 2.8-3.8 BR buffer medium, the third generation cephalosporin antibiotics (TGCs) such as ceftazidime (CZD), ceftriaxone (CTRX), cefoperazone (CPZ), and cefotaxime (CFTM) react with palladium(II) (Pd(II)) to form 1:2 yellowish-brown cationic chelates, which further react with 4, 5-dibromofluorescein (DBF) to form 1:3 brown ion-association complexes. As a result, not only the spectra of absorption and fluorescence are changed, but also the resonance Rayleigh scattering (RRS) is enhanced greatly and the new RRS spectra are observed. The four TGCs products have similar spectral characteristics and their maximum RRS wavelengths are all located at 291 nm. The quantitative determination ranges and the detection limits of the four TGCs are 0.0065-1.0 μg mL−1 and 2.0 ng mL−1 for CZD, 0.0070-1.1 μg mL−1 and 2.2 ng mL−1 for CTRX, 0.0090-1.6 μg mL−1 and 2.7 ng mL−1 for CPZ, and 0.014-2.2 μg mL−1 and 4.2 ng mL−1 for CFTM, respectively. The optimum conditions of the reactions and the effects of foreign substances are investigated, and the composition of ion-association complexes is discussed also. Based on the ion-association reaction, a highly sensitive, simple and rapid method has been proposed to the determination of TGCs.  相似文献   

17.
An immunoaffinity (IA) sorbent with antibody fragments was prepared for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis–mass spectrometry (IA-SPE-CE–MS). The antibody fragmentation was evaluated by MALDI-TOF-MS. Fab′ fragments obtained from a polyclonal IgG antibody against Endomorphins 1 and 2 (End1 and End2) were covalently attached to succinimidyl silica particles to prepare the IA sorbent. An IA-SPE-CE–MS methodology was established analyzing standard solutions of End1 and End2 and acceptable repeatability, linearity ranges and LODs (0.5 and 5 ng mL−1, respectively) were obtained. The LOD of End1 was slightly better than that previously obtained using an IA sorbent with intact antibodies (1 ng mL−1). In human plasma samples, End1 and End2 could be detected at 1 and 50 ng mL−1, respectively, which meant an improvement of 100 and 2-fold with regard to the LODs using an IA sorbent with intact antibodies (100 ng mL−1).  相似文献   

18.
Different second-order multivariate calibration algorithms, namely parallel factor analysis (PARAFAC), N-dimensional partial least-squares (N-PLS) and multivariate curve resolution-alternating least-squares (MCR-ALS) have been compared for the analysis of four fluoroquinolones in aqueous solutions, including some human urine samples (additional four fluoroquinolones were simultaneously determined by univariate calibration). Data were measured in a short time with a chromatographic system operating in the isocratic mode. The detection system consisted of a fast-scanning spectrofluorimeter, which allows one to obtain second-order data matrices containing the fluorescence intensity as a function of retention time and emission wavelength. The developed approach enabled us to determine eight analytes, some of them with overlapped profiles, without the necessity of applying an elution gradient, and thus significantly reducing both the experimental time and complexity. The study was employed for the discussion of the scopes of the applied second-order chemometric tools. The quality of the proposed technique coupled to each of the evaluated algorithms was assessed on the basis of the figures of merit for the determination of fluoroquinolones in the analyzed water and urine samples. Univariate calibration of four analytes led to limits of detection in the range 20–40 ng mL−1 and root mean square errors for the validation samples in the range 30–60 ng mL−1 (corresponding to relative prediction errors of 3–8%). The ranges for second-order multivariate calibration (using PARAFAC and N-PLS) of the remaining four analytes were: limit of detection, 2–8 ng mL−1, root mean square errors, 3–50 ng mL−1 and relative prediction errors, 1–5%.  相似文献   

19.
An isocratic high-performance liquid chromatographic method has been developed for the measurement of serotonin, 5-hydroxyindolacetic and homovanillic acids in dried blood spots and in platelet poor and rich plasma samples. Analyses were carried out on a C18 reversed-phase column using a mobile phase composed of 13% methanol and 87% aqueous citrate buffer, containing octanesulfonic and ethylendiaminotetracetic acids. Coulometric detection was used, setting the guard cell at +0.100 V, the first analytical cell at −0.200 V and the second analytical cell at +0.400 V. For the pre-treatment of biological samples a novel solid-phase extraction procedure, based on mixed-mode reversed-phase – strong anion exchange Oasis cartridges, was implemented. Extraction yields of the analytes from all these matrices were satisfactory, being always higher than 89.0%. The calibration curve was linear over the on-column concentration range of 0.1–22.5 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and of 0.25–22.5 ng mL−1 for homovanillic acid. The sensitivity was good with a limit of detection of 0.05 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and 0.12 ng mL−1 for homovanillic acid. Results were also satisfactory in terms of precision, selectivity and accuracy. The analytical method was successfully applied to human platelet poor and rich plasma samples and to dried blood spots from volunteers and psychiatric patients.  相似文献   

20.
The determination of sialic acids (SIAs) has recently gained interest because of their potential role as markers of inflammatory disorders or chronic diseases. Hydrolysis of conjugated derivatives, solid-phase extraction (SPE) and derivatization steps constitute sample preparation prior to insertion of the analytical sample into a μ-liquid chromatograph-laser induced fluorescence (μ-LC-LIF) detector in the present method for the determination of two representative SIAs of human metabolism. Ultrasound-accelerated hydrolysis released free SIAs, which were efficiently concentrated in a dynamic manner using a lab-on-valve (LOV) module that allows automation of SPE for preconcentration and cleanup. This step was on-line connected with DMB-labeling of SIAs (derivatization), which was shortened from 180 min required with the conventional heating method to 20 min with ultrasound assistance. Individual separation of the target analytes was achieved within 20 min by μ-LC, while LIF detection endowed the overall method with high sensitivity. The LODs and LOQs provided by the method ranged 0.1–0.8 ng mL−1 and 0.4–1.0 ng mL−1 (between 0.1–0.8 pg and 0.4–1.0 pg expressed as on-column amount), respectively. High efficiency for interferents removal by SPE enabled the application of the method to four different biofluids—serum, urine, saliva and breast milk—for the determination of the target metabolites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号