首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 842 毫秒
1.
Cao Y  Lee Koo YE  Kopelman R 《The Analyst》2004,129(8):745-750
150-250 nm Poly(decyl methacrylate)(PDMA) fluorescent ratiometric nanosensors for dissolved oxygen have been developed. Platinum octaethylporphine ketone (PtOEPK), the oxygen-sensitive dye, and octaethylporphyrin (OEP), the oxygen-insensitive dye, have been incorporated into PDMA nanoparticles to make the sensors ratiometric. Based on the corresponding Stern-Volmer plot, these nanosensors exhibit almost complete linearity over the whole range of dissolved molecular oxygen from 0 to 42.5 ppm (deoxygenated to pure oxygen-bubbled water). The overall quenching response is up to 97.5%, the best so far for all dissolved oxygen optical sensors. These PEBBLE nanosensors also show very good reversibility and stability to leaching and photobleaching, as well as very short response times and no perturbation by proteins. In human plasma they demonstrate a robust oxygen sensing capability, little affected by light scattering and autofluorescence. Potential applications include intracellular oxygen imaging and microresolved pressure profiles in biological and other heterogenous environments.  相似文献   

2.
A variety of luminescent oxygen nanosensors were prepared by addressable staining of poly(styrene-block-vinylpyrrolidone) nanobeads with metal–ligand complexes whose luminescence is quenched by oxygen. They display optimal sensitivity in responding to dissolved oxygen in concentrations from 0 to 100% air saturation. The nanobeads based on cyclometallated iridium(III) complexes with coumarins are especially promising due to excellent brightnesses. The nanosensors respond virtually in real time to altering oxygen concentration and are capable of recording even very rapid changes in oxygen partial pressure. Signals are obtained by determination of luminescence lifetime in the frequency domain and in the time domain, and by ratiometric measurement of luminescence intensity. The nanosensors have been applied to sensing and imaging of dissolved oxygen, to monitor the consumption of oxygen during enzymatic oxidation of glucose, and to monitoring dissolved oxygen in a growing culture of E. coli.  相似文献   

3.
比率式荧光传感通过在同一传感基质中掺杂两种或两种以上对分析物具有不同响应的发光体,根据不同的光发射信号比值构建起来的光化学传感体系,能更好满足实际检测的需要。近年来,比率式荧光纳米传感器的构建已引起了人们的广泛关注。该文介绍了比率式荧光纳米氧传感器的制备方法、传感特性和应用情况,并对其传感检测的发展和应用前景进行了分析和展望。  相似文献   

4.
Incorporation of a dual-FRET dye pair into mesoporous silica nanoparticles yields sensitive and sensing-range tunable nanosensors with good reversibility that can be used for ratiometric pH measurements under a single-wavelength excitation.  相似文献   

5.
Optical nanoparticle pH sensors designed for ratiometric measurements have previously been synthesized using post-functionalization approaches to introduce sensor molecules and to modify nanoparticle surface chemistry. This strategy often results in low control of the nanoparticle surface chemistry and is prone to batch-to-batch variations, which is undesirable for succeeding sensor calibrations and cellular measurements. Here we provide a new synthetic approach for preparing nanoparticle pH sensors based on self-organization principles, which in comparison to earlier strategies offers a much higher design flexibility and high control of particle size, morphology and surface chemistry.  相似文献   

6.
Conventional optical nanoparticle pH sensors that are designed for ratiometric measurements in cells have been based on utilizing one sensor fluorophore and one reference fluorophore in each nanoparticle, which results in a relatively narrow dynamic measurement range. This results in substantial challenges when conducting live cell measurements, which often leads to misleading results. In the present work we provide a simple solution to this problem.  相似文献   

7.
Fluorescent nano-PEBBLE sensors designed for intracellular glucose imaging   总被引:3,自引:0,他引:3  
Xu H  Aylott JW  Kopelman R 《The Analyst》2002,127(11):1471-1477
Polyacrylamide-based, ratiometric, spherical, optical nanosensors, or polyacrylamide PEBBLEs (Probes Encapsulated By Biologically Localized Embedding), have been fabricated, aimed at real-time glucose imaging in intact biological systems, i.e. living cells. These nanosensors are prepared using a microemulsion polymerization process, and their average size is about 45 nm in diameter. The sensors incorporate glucose oxidase (GOx), an oxygen sensitive fluorescent indicator (Ru[dpp(SO3Na)2]3)Cl2, and an oxygen insensitive fluorescent dye, Oregon Green 488-dextran or Texas Red-dextran, as a reference for the purpose of ratiometric intensity measurements. The enzymatic oxidation of glucose to gluconic acid results in the local depletion of oxygen, which is measured by the oxygen sensitive ruthenium dye. The small size and inert matrix of these sensors allows them to be inserted into living cells with minimal physical and chemical perturbations to their biological functions. The PEBBLE matrix protects the enzyme and fluorescent dyes from interference by proteins in cells, enabling reliable in vivo chemical analysis. Conversely, the matrix also significantly reduces the toxicity of the indicator and reference dyes to the cells, so that a larger variety of dyes can be used in optimal fashion. Furthermore, the PEBBLE matrix enables the synergistic approach in which there is a steady state of local oxygen consumption, and this cannot be achieved by separately introducing free enzyme and dyes into a cell. The work presented here describes the production and characterization of glucose sensitive PEBBLEs, and their potential for intracellular glucose measurements. The sensor response is determined in terms of the linear range, ratiometric operation, response time, sensor stability, reversibility and immunity to interferences.  相似文献   

8.
It is significant for cell physiology to keep the homeostasis of p H, and it is highly demanded to develop ratiometric fluorescent sensors toward p H. In this work, under mild condition, through the electrostatic interaction between carbon nanodots(CDs) and organic molecules, two novel ratiometric fluorescence hybrid nanosensors were fabricated for sensing acidic p H. These nanohybrid systems possess dual emission peaks at 455 and 527 nm under a single excitation wavelength of 380 nm in acidic p H condition.With the increasing of p H, the fluorescence of the 1,8-naphthalimide derivative completely quenches,while the blue fluorescence of CDs keeps constant. Furthermore, the CDsàorganic molecular nanohybrids exhibit excellent anti-disturbance ability, reversible p H sensing ability, and a linear response range in wide p H range respectively. Besides the ability to target lysosome, with one of the nanosensor, stimulated p H change has been successfully tracked in a ratiometric manner via fluorescence imaging.  相似文献   

9.
Ray A  Koo Lee YE  Epstein T  Kim G  Kopelman R 《The Analyst》2011,136(18):3616-3622
Intracellular pH mapping is of great importance as it plays a critical role in many cellular events. Also, in tissue, pH mapping can be an indicator for the onset of cancer. Here we describe a biocompatible, targeted, ratiometric, fluorescent, pH sensing nano-PEBBLE (Photonic Explorer for Biomedical use with Biologically Localized Embedding) that is based on two-photon excitation. Two-photon excitation minimizes the photobleaching and cell autofluorescence drastically, leading to an increase in the signal-to-noise ratio. PEBBLE nanosensors provide a novel approach for introducing membrane impermeant dyes, like HPTS, into cells. We use both non-targeted and F3 peptide targeted PEBBLE nanosensors for intracellular pH measurement of 9L cells. The intracellular measurements suggest that the non-targeted nanosensors are mostly trapped in endosomes, whereas the F3 peptide targeting enables them to escape/avoid these acidic compartments. Combining the advantages of pH sensitive PEBBLE nanoparticles, including their specific targeting, with the advantages of two-photon microscopy provides an attractive and promising prospect for non-invasive real-time monitoring of pH inside cancer cells and tissues.  相似文献   

10.
The design flexibility that polymeric micelles offer in the fabrication of optical nanosensors for ratiometric pH measurements is investigated. pH nanosensors based on polymeric micelles are synthesized either by a mixed‐micellization approach or by a postmicelle modification strategy. In the mixed‐micellization approach, self‐assembly of functionalized unimers followed by shell cross‐linking by copper‐catalyzed azide‐alkyne cycloaddition (CuAAC) results in stabilized cRGD‐functionalized micelle pH nanosensors. In the postmicelle modification strategy, simultaneous cross‐linking and fluorophore conjugation at the micelle shell using CuAAC results in a stabilized micelle pH nanosensor. Compared to the postmicelle modification strategy, the mixed‐micellization approach increases the control of the overall composition of the nanosensors. Both approaches provide stable nanosensors with similar pKa profiles and thereby nanosensors with similar pH sensitivity.

  相似文献   


11.
Riu J  Maroto A  Rius FX 《Talanta》2006,69(2):288-301
Nanoscience and nanotechnology deal with the study and application of structures of matter of at least one dimension of the order of less than 100 nm (1 nm = one millionth of a millimetre). However, properties related to low dimensions are more important than size. Nanotechnology is based on the fact that some very small structures usually have new properties and behaviour that are not displayed by the bulk matter with the same composition.This overview introduces and discusses the main concepts behind the development of nanosensors and the most relevant applications in the field of environmental analysis. We focus on the effects (many of which are related to the quantum nature) that distinguish nanosensors and give them their particular behaviour. We will review the main types of nanosensors developed to date and highlight the relationship between the property monitored and the type of nanomaterial used.We discuss several nanostructures that are currently used in the development of nanosensors: nanoparticles, nanotubes, nanorods, embedded nanostructures, porous silicon, and self-assembled materials. In each section, we first describe the type of nanomaterial used and explain the properties related to the nanostructure. We then briefly describe the experimental set up and discuss the main advantages and quality parameters of nanosensing devices. Finally, we describe the applications, many of which are in the environmental field.  相似文献   

12.
In this paper,the relationship of intracellular acidification and apoptosis in Hela cells induced by vin-cristine sulfate has been studied by use of the ratiometric pH nanosensors that have been developed by our group,employing fluorescein isothiocyanate(FITC) doped as the pH-sensitive dye and Tris(2,2'-bipyidyl) dichlororuthenium(II) hexahydrate(RuBpy) doped as reference dye. The pH change of the Hela cells induced by vincristine sulfate has been monitored in vivo,in situ and real time by use of the ratiometric pH nanosensors. The experimental results show that the pH of the apoptotic Hela cells induced by vincristine sulfate has been acidified from 7.11 to 6.51,and the percentage of intra-cellular acidification is correlated with the induced concentration and incubation time of the vincristine sulfate. The further study of the percentage of intracellular acidification and the percentage of apop-tosis of Hela cells at the same time reveals that apoptosis of Hela cells induced by vincristine sulfate is preceded by intracellular acidification. These results would provide theoretical foundation for the therapy of cancer through interfering the pH of cells by use of vincristine sulfate or other anti-cancer drugs.  相似文献   

13.
We describe an exciting opportunity for affinity biosensing using a ratiometric approach to the angular-dependent light scattering from bioactivated and subsequently aggregated noble metal colloids. This new model sensing platform utilizes the changes in particle scattering from very small colloids, which scatter light according to traditional Rayleigh theory, as compared to the changes in scattering observed by much larger colloidal aggregates, formed due to a bioaffinity reaction. These larger aggregates no longer scatter incident light in a Cos(2) theta dependence, as is the case for Rayleigh scattering, but instead scatter light in an increased forward direction as compared to the incident geometry. By subsequently taking the ratio of the scattered intensity at two angles, namely 90 degrees and 140 degrees , relative to the incident light, we can follow the association of biotinylated bovine serum albumin-coated 20 nm gold colloids, cross-linked by additions of streptavidin. This new model system can be potentially applied to many other nanoparticle assays and has many advantages over traditional fluorescence sensing and indeed light-scattering approaches. For example, a single nanoparticle can have the equivalent scattered intensity as 10(5) fluorescing fluorescein molecules substantially increasing detection; the angular distribution of scattered light from noble metal colloids is substantially easier to predict as compared to fluorescence; the scattered light is not quenched by biospecies; the ratiometric measurements described here are not dependent on colloid concentration as are other scattering techniques; and finally, the noble metal colloids are not prone to photodestruction, as is the case with organic fluorophores.  相似文献   

14.
A flexible, highly sensitive sensor of oxygen in non-aqueous solvents is described. It consists of CdSe/ZnS nanoparticles decorated with a considerable number of pyrene units, thus making the formation of the pyrene excimer possible. The emission of the pyrene excimer and that of the nanoparticle are suitably separated from each other and also from the excitation wavelength. This sensor can be applied as a ratiometric oxygen sensor by using the linear response of the pyrene excimer lifetime combined with the linear response of the nanoparticle excited state lifetime. This nanohybrid has been assayed in seven media with different dielectric constants and viscosities over the whole oxygen concentration range. In addition, the sensor versatility provides an easy way for monitoring oxygen diffusion through systems.  相似文献   

15.
Borisov SM  Klimant I 《The Analyst》2008,133(10):1302-1307
Optical nanosensors are advanced analytical tools that combine advantages of conventional sensor technology with flexibility in use of dissolved indicators. Introduced a decade ago, optical nanosensors attract increasingly more attention each year. In fact, the number of reports on the topic has doubled in the last 2-3 years. In this contribution, we aim to highlight recent developments of optical nanosensors and give an overview on strategies to design these nanosensors with different levels of complexity. Applications of this smart technology, advantages, challenges, and risks will be discussed.  相似文献   

16.
In this work, we have designed and synthesized the compound Ratio-HPSSC, based on a tetrakis(4-hydroxyphenyl)porphyrin-coumarin scaffold, as a new ratiometric fluorescent probe for thiols. The ratiometric probe Ratio-HPSSC is highly selective and sensitive to thiols. Importantly, the novel ratiometric probe exhibited a remarkable change in emission color from red to blue. This key feature allows Ratio-HPSSC to be employed for thiol detection by simple visual inspection. Furthermore, we have demonstrated that Ratio-HPSSC is suitable for ratiometric fluorescence imaging of thiols in living cells. We believe that the new ratiometric probe will find interesting applications in chemistry, biology, and medicine.  相似文献   

17.
采用一步聚合的方法,制备了以疏水的聚甲基丙烯酸甲酯(PMMA)为核、亲水性的聚电解质支化聚乙烯亚胺(PEI)为壳的纳米粒子分散液.将供体荧光团4-胺基-7-硝基-N-辛基苯并[1,2,5]噁二唑(NBD)以包埋的方式在聚合过程中直接引入PMMA核内部,而受体荧光团罗丹明衍生物SRHB通过吸附作用进入PEI-PMMA核壳界面,构成了含有两种不同荧光分子且可对Hg2+进行荧光比率检测的传感器.考察了含荧光分子的聚合物粒子光谱学性质,证明两种荧光分子均被引入了聚合物粒子体系.在汞离子的荧光检测试验中,加入Hg2+后,体系中的NBD荧光强度下降,而罗丹明的特征发射峰在579 nm处出现,并随着Hg2+浓度的增加,受体/供体的荧光强度比值呈现增长趋势.研究还发现,聚合物粒子基荧光探针对于Hg2+具有较好的选择性,且最佳使用范围是体系pH值在5~8之间,其检测Hg2+的最低浓度可达到1μmol/L.  相似文献   

18.
This communication describes ultrabright single-nanoparticle ratiometric temperature sensors based on semiconducting polymer dots (Pdots). We attached the temperature sensitive dye-Rhodamine B (RhB), whose emission intensity decreases with increasing temperature-within the matrix of Pdots. The as-prepared Pdot-RhB nanoparticle showed excellent temperature sensitivity and high brightness because it took advantage of the light harvesting and amplified energy transfer capability of Pdots. More importantly, the Pdot-RhB nanoparticle showed ratiometric temperature sensing under a single wavelength excitation and has a linear temperature sensing range that matches well with the physiologically relevant temperatures. We employed Pdot-RhB for measuring intracellular temperatures in a live-cell imaging mode. The exceptional brightness of Pdot-RhB allows this nanoscale temperature sensor to be used also as a fluorescent probe for cellular imaging.  相似文献   

19.
We demonstrate a nanoparticle based ratiometric fluorosensor suitable for non-invasive high-resolution imaging of complex samples. Coextraction generates a movement of a solvatochromic dye, with a consequent shift from plasmophore coupled emission towards longer wavelength scattering enhanced emission. The nanoparticle doped sensors confirmed superior sensitivity, reversibility, durability and overall image quality.  相似文献   

20.
A fluorescent PEBBLE nanosensor for intracellular free zinc   总被引:2,自引:0,他引:2  
The development and characterisation of a fluorescent optical PEBBLE (Probe Encapsulated By Biologically Localised Embedding) nanosensor for the detection of zinc is detailed. A ratiometric sensor has been fabricated that incorporates two fluorescent dyes; one is sensitive to zinc and the other acts as a reference. The sensing components are entrapped within a polymer matrix by a microemulsion polymerisation process that produces spherical sensors that are in the size region of 20 to 200 nm. Cellular measurements are made possible by the small sensor size and the biocompatibility of the matrix. The effects of reversibility, photobleaching and leaching have been examined, as well as the selectivity towards zinc over other cellular ions such as Na+, Ca2+, K+, and Mg2+. The dynamic range of these sensors was found to be 4 to 50 microM Zn2+ with a linear range from 15 to 40 microM. The response time for the PEBBLE is less than 4 s and the sensor is reversible. In addition, the nanosensors are photostable and leaching from the matrix, determined using a novel method, is minimal. These sensors are capable of real-time inter- and intra-cellular imaging and are insensitive to interference from proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号